Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Biomédica (Bogotá) ; 43(3): 315-322, sept. 2023. graf
Article in English | LILACS | ID: biblio-1533942

ABSTRACT

Introduction. Over time, efforts have been invested in the design of new instruments that overcome the disadvantages of the gold standard instrument in surgery, the scalpel. As a result, electronic equipment has emerged such as the electric scalpel and laser devices. The available evidence on these instruments suggests that the tissue response is related to each instrument's physical and biological cutting principles. Objective. To compare the histological changes in gingiva samples associated with surgical cutting performed with a 940 nm diode laser, a 2780 nm erbium, chromium: yttriumscandium-gallium-garnet (Er,Cr:YSGG) laser, and an electric scalpel, by presenting a series of cases. Case presentation. We present three cases of healthy patients undergoing cosmetic surgery. The clinical examination revealed exposure of a keratinized gingiva band greater than 4 mm, normal color and texture in gingival tissue, with a firm consistency and no bleeding on periodontal probing. Gingivectomy was indicated with the following protocols: Diode laser of 940 nm at 1 W, in continuous mode; Er,Cr:YSGG laser of 2780 nm at 2.5 W, 75 Hz, H mode, air 20, water 40, gold tip MT4); and electric scalpel in cutting mode at power level four. Gingival tissue samples were taken and stored in 10% formaldehyde for histological analysis. Conclusion. All the evaluated cutting instruments generated histological changes produced by the thermal effect, the main ones being collagen coagulation and carbonization. The depth of thermal damage caused by the 2780 nm Er,Cr:YSGG laser was much lesser than that induced by the electric scalpel and the 940 nm diode laser.


Introducción. Históricamente se ha invertido esfuerzo en el diseño de nuevos instrumentos que superen las desventajas del estándar de referencia en cirugía, el bisturí. Como consecuencia de esto, han surgido equipos electrónicos como el electrobisturí y los diferentes dispositivos de tecnología láser. La información disponible sobre estos instrumentos sugiere que la respuesta del tejido intervenido está influenciada por los principios físicos y biológicos de corte del instrumento. Objetivo. Comparar los cambios histológicos en muestras de encía asociados al corte quirúrgico realizado con láser de diodo de 940 nm, láser de erbio, cromo: itrio-escandio-galio-granate (Er,Cr:YSGG) (2780nm) y electrobisturí mediante una presentación de serie de casos. Presentación de los casos. Se presentan tres casos de pacientes sanos sometidos a cirugía estética. El examen clínico reveló la exposición de una banda gingival queratinizada mayor de 4 mm, tejido gingival de color y textura normales, de consistencia firme y sin sangrado al sondaje periodontal. Se indicó gingivectomía con los siguientes protocolos: láser de diodo de 940 nm a 1 W, en modo continuo; láser de Er,Cr:YSGG de 2780 nm a 2,5 W, 75 Hz, modo H, aire 20, agua 40, punta de oro MT4; y bisturí eléctrico en modo de corte, a nivel de potencia cuatro. Se tomaron muestras de tejido gingival y se almacenaron en formaldehído al 10 % para su análisis histológico. Conclusión. Los tres instrumentos de corte generaron cambios histológicos producidos por el efecto térmico; los principales fueron coagulación del colágeno y carbonización. La profundización del daño térmico causada por el láser de Er,Cr:YSGG de 2780 nm fue mucho menor que la generada por el electrobisturí y por el láser de diodo de 940 nm.


Subject(s)
Gingivectomy , Artifacts , Lasers, Semiconductor , Lasers, Solid-State , Histology
2.
J. oral res. (Impresa) ; 12(1): 86-99, abr. 4, 2023. ilus
Article in English | LILACS | ID: biblio-1512278

ABSTRACT

Objective: The objective of this study was to investigate the morphology, proliferation, and differentiation of gingival mesenchymal stem cells (GMSCs) irradiated with a 970 nm Diode Laser (LLLT). It is essential to validate the efficacy of treatment, optimize irradiation conditions and guarantee the safety and quality of stem cells for future use in dental applications. Materials and Methods: GMSCs were cultured in standard conditions and irradiated with a Diode laser (970 nm, 0.5W) with an energy density of 9J/cm2. Cell proliferation was assessed with the WST-1 proliferation kit. GMSCs were differentiated into chondrogenic and osteogenic lineages. Cell morphology was performed with Hematoxylin/eosin staining, and quantitative nuclear analysis was done. Cell viability was monitored with trypan blue testing. Results: GMSCs subjected to irradiation demonstrated a significant increase in proliferation at 72 hours compared to the non-irradiated controls (p=0.027). This indicates that the 970 nm diode laser has a stimulatory effect on the proliferation of GMSCs. LLLT-stimulated GMSCs exhibited the ability to differentiate into chondrogenic and osteogenic lineages. A substantial decrease in cell viability was observed 24 hours after irradiation (p=0.024). However, after 48 hours, the cell viability recovered without any significant differences. This indicates that there might be a temporary negative impact on cell viability immediately following irradiation, but the cells were able to recover and regain their viability over time. Conclusions: This study support that irradiation with a 970 nm diode laser could stimulate the proliferation of GMSCs, maintain their ability to differentiate into chondrogenic and osteogenic lineages, and has minimal impact on the mor- phological characteristics of the cells. These results support the potential use of NIR Lasers in combination with GMSCs as a promising strategy for dental treatments.


Objetivo: El objetivo de este estudio fue investigar la morfología, proliferación y diferenciación de las células madre mesenquimatosas (GMSC) irradiadas con un láser de diodo de 970 nm (LLLT). Es fundamental validar la eficacia del tratamiento, optimizar las condiciones de irradiación y garantizar la seguridad y calidad de las células madre para su uso futuro en aplicaciones dentales.Materiales y Métodos: Las GMSC se cultivaron en condiciones estándar y se irradiaron con un láser de diodo (970 nm, 0,5 W) con una densidad de energía de 9 J/cm2. La proliferación celular se evaluó con el kit de proliferación WST-1. Las GMSC se diferenciaron en linajes condrogénicos y osteogénicos. La morfología celular se realizó con tinción de hematoxilina/eosina y se realizó un análisis nuclear cuantitativo. La viabilidad celular se controló con prueba de azul de tripano. Resultados: Las GMSC sometidas a irradiación demostraron un aumento significativo en la proliferación a las 72 horas en comparación con los controles no irradiados (p=0,027). Esto indica que el láser de diodo de 970 nm tiene un efecto estimulante sobre la proliferación de GMSC. Las GMSC estimuladas con LLLT exhibieron la capacidad de diferenciarse en linajes condrogénicos y osteogénicos. Se observó una disminución sustancial de la viabilidad celular 24 horas después de la irradiación (p=0,024). Sin embargo, después de 48 horas, la viabilidad celular se recuperó sin diferencias significativas. Esto indica que podría haber un impacto negativo temporal en la viabilidad de las células inmediatamente después de la irradiación, pero las células pudieron recuperarse y recuperar su viabilidad con el tiempo. Conclusión: En conclusión, este estudio respalda que la irradiación con un láser de diodo de 970 nm podría estimular la proliferación de GMSC, mantener su capacidad para diferenciarse en linajes condrogénicos y osteogénicos y tiene un impacto mínimo en las características morfológicas de las células. Estos resultados respaldan el uso potencial de láseres NIR en combinación con GMSC como una estrategia prometedora para tratamientos dentales.


Subject(s)
Humans , Low-Level Light Therapy , Cell Proliferation/radiation effects , Lasers, Semiconductor , Mesenchymal Stem Cells/radiation effects , In Vitro Techniques , Gingiva/radiation effects
3.
Gac. méd. espirit ; 24(1): [18], abr. 2022.
Article in Spanish | LILACS | ID: biblio-1404892

ABSTRACT

RESUMEN Fundamento: Aunque la estomatitis aftosa recurrente no tiene una etiología bien definida porque es una enfermedad multicausal, se ha reconocido que las interacciones o el debilitamiento del sistema inmunitario, contribuyen principalmente a la magnitud del proceso patológico. Las propuestas de tratamiento en pacientes inmunocomprometidos son diversas y por lo general se centran en alteraciones inmunológicas específicas. Objetivo: Evaluar el efecto clínico de los tratamientos propuestos para la estomatitis aftosa recurrente en pacientes inmunocomprometidos. Metodología: La búsqueda se realizó en las bases de datos PubMed/Medline y Cochrane. Se incluyeron ensayos clínicos que tuviesen entre sus variables de respuesta principales: Cicatrización de la úlcera aftosa, tiempo de cicatrización, de recurrencia e intensidad del dolor y entre las variables secundarias: Los efectos adversos y los síntomas. La extracción de datos se realizó de manera independiente por los autores. Se aplicó la metodología por la colaboración Cochrane para evaluar el riesgo de sesgo en cada uno de los estudios. Resultados: Se incluyeron 11 ensayos clínicos (8 controlados) publicados entre 1995 y 2020 y que aportan resultados de la eficacia de varias intervenciones terapéuticas: talidomida (4), irsogladine (2), rebamipida (1), láser de diodo (1), cápsulas de Omega-3 (1), vitamina B 12 (1), Complejo B (1). Seis de estos estudios incluyeron pacientes con la forma menor de estomatitis aftosa recurrente. El periodo de seguimiento estuvo entre los 14 y 360 días. Conclusiones: La talidomida puede ser eficaz en el alivio de los síntomas, la cicatrización y remisión de las lesiones, el diodo de láser y vitamina B12 en la disminución de la intensidad del dolor.


ABSTRACT Background: Although recurrent aphthous stomatitis does not have a well-defined etiology due to it is a multicausal disease, it has been recognized that the interactions or the weakening of the immune system, contribute mainly to the magnitude of the process pathological. Treatment proposals in immune compromised patients are diverse and they usually focus on specific immunological alterations. Objective: To evaluate the clinical effect of the proposed treatments for recurrent aphthous stomatitis in immunocompromised patients. Methodology: The search was performed in the PubMed/Medline and Cochrane databases. Clinical trials were included that could have among their main response variables: Aphthous ulcer healing, healing time, recurrence and pain intensity and among the secondary variables: Adverse effects and symptoms. data extraction was done independently by the authors. The methodology was applied by Cochrane collaboration to assess the risk of bias in each of the studies. Results: 11 clinical trials (8 controlled) published between 1995 and 2020 and that provided the results of the efficacy of various therapeutic interventions: thalidomide (4), irsogladine (2), rebamipide (1), diode laser (1), Omega-3 capsules (1), vitamin B 12 (1), Complex B (1). Six of these studies included patients with the minor form of stomatitis recurrent aphthous. The follow-up period was between 14 and 360 days. Conclusions: Thalidomide may be effective in relieving symptoms, healing and remission of the lesions, the laser diode and vitamin B12 in the decrease of the intensity of the pain.


Subject(s)
Stomatitis, Aphthous/therapy , Thalidomide/therapeutic use , Vitamin B 12/therapeutic use , Lasers, Semiconductor/therapeutic use , Systematic Review
4.
Univ. sci ; 19(2): 107-113, mayo-ago. 2014. ilus, tab
Article in Spanish | LILACS-Express | LILACS | ID: lil-717120

ABSTRACT

Se presentan los modelos de hopping de rango variable (variable range hopping; VRH), vecinos cercanos (nearest neighbor hopping; NNH) y barreras de potencial presentes en las fronteras de grano; como mecanismos de transporte eléctrico predominantes en los materiales semiconductores para aplicaciones fotovoltaicas. Las medidas de conductividad a oscuras en función de temperatura fueron realizadas para región de bajas temperaturas entre 120 y 400 K con Si y compuestos Cu3BiS2 y Cu2ZnSnSe4. Siguiendo la teoría de percolación, se obtuvieron parámetros hopping y la densidad de estados cerca del nivel de Fermi, N(E F), para todas las muestras. A partir de los planteamientos dados por Mott para VRH, se presentó el modelo difusional, que permitió establecer la relación entre la conductividad y la densidad de estados de defecto o estados localizados en el gap del material. El análisis comparativo entre modelos, evidenció, que es posible obtener mejora hasta de un orden de magnitud en valores para cada uno de los parámetros hopping que caracterizan el material.


Here, we present variable range hopping (VRH) models, nearest neighbor hopping (NNH) and potential barriers present at the grain boundaries, as well as mechanisms of electrical transport predominant in semiconductor materials for photovoltaic applications. We performed dark conductivity measures according to temperature for low temperature regions between 120 and 400 K in Si and Cu3BiS2 and Cu2ZnSnSe4 compounds. Using the percolation theory, we obtained hopping parameters and the density of states near the Fermi, N(E F) level for all samples. Using the approach by Mott for VRH, we obtained the diffusion model, which established the relationship between conductivity and density of defect states or localized gap states of the material. The comparative analysis between models evidenced that it is possible to obtain improvement of an order of magnitude in the values of each of the hopping parameters that characterize the material.


Apresentam-se os modelos de hopping de categoria variável (variable range hopping; VRH), vizinhos próximos (nearest neighbor hopping, NNH) e barreiras de potenciais presentes nas fronteiras de grãos; como mecanismo de transporte elétrico predominantes nos materiais semicondutores para aplicações fotovoltaicas. As medidas de condutividade no escuro em função da temperatura foram realizadas para região de baixas temperaturas entre 120 e 400 K com Si e compostos Cu3BiS2 e Cu2ZnSnSe4. Seguindo a teoria da percolação obtiveram-se parâmetros hopping e a densidade de estados próximos do nível Fermi[BO1] N(E F) para toda a amostra. A partir das abordagens seguidas por Mott para VRH, apresentou-se o modelo de difusão, que permitiu estabelecer a relação entre a condutividade e a densidade de estados de defeito ou estados localizados no gap do material. A análise comparativa dos modelos mostrou que é possível obter melhoria até de uma amplitude de magnitude em valores para cada um dos parâmetros hopping que caracterizam o material.

5.
Univ. sci ; 19(2): 147-152, mayo-ago. 2014. ilus, tab
Article in Spanish | LILACS-Express | LILACS | ID: lil-717125

ABSTRACT

Se presentan propiedades eléctricas y de transporte en películas nanocristalinas del compuesto cuaternario Cu2ZnSnSe4 (CZTSe) por método de co-evaporación física. Las muestras fueron crecidas sobre sustratos de vidrio soda-lime y variando en rango los parámetros de síntesis: masa de Cu y temperatura de sustrato. A partir de termopotencia a temperatura ambiente y de transmitancia espectral, se encontró que el material está caracterizado por conductividad tipo n y ancho de banda de energía prohibida de 1.7 eV, respectivamente. Las medias de conductividad eléctrica (región de bajas temperaturas; 90-200 K) mostraron que los procesos de conducción se realizan vía hopping de rango de variable entre estados extendidos. Los parámetros que caracterizaron éste mecanismo, energía de activación (Whopp) y rango hopping (Rhopp), fueron obtenidos mediante teoría de percolación y modelo difusional. Se obtuvo, que para las muestras CZTSe la densidad de estados de defecto cerca del nivel de Fermi del material, N(Ef), está alrededor de 3,403x10(18) cm-3 eV-1. Se presentó correlación entre parámetros de depósito y propiedades eléctricas. Se observó influencia de parámetros sobre formación de fases adicionales en el compuesto.


Here, we present electronic and transport properties of quaternary Cu2ZnSnSe4 (CZTSe) nanocrystalline films fabricated by physical co-evaporation. The samples were grown on soda-lime glass substrates and synthesis parameter ranges, Cu mass and substrate temperature were varied. Using thermopower at room temperature and spectral transmittance we found that the material is characterized by n-type conductivity and forbidden energy bandwidth of 1.7 eV, respectively. Electrical conductivity means (low temperature region; 90-200 K) showed that conductivity processes occur via variable range hopping between extended states. We obtained the parameters characterizing this mechanism, activation energy (Whopp), and range hopping (Rhopp), by employing the percolation theory and diffusion model. The density of defect states near the Fermi level of the material, N (Ef) of the CZTSe samples is about 3,403x10(18) cm-3 eV-1. We found a correlation between deposition parameters and electrical properties and observed a parameter influence on the formation of additional phases in the compound.


Apresentam-se propriedades elétricas e de transporte em películas nano-cristalinas do composto quaternário Cu2ZnSnSe4 (CZTSe) pelo método de co-evaporação física. As amostras foram crescidas sobre substratos de vidro soda-lime e variando a amplitude dos parâmetros de síntese: massa de Cu e temperatura do substrato. A partir de termo-potência a temperatura ambiente e de transmissão espectral, encontrou-se que o material está caracterizado pela condutividade tipo n e largura de banda de energia proibida de 1.7 eV, respetivamente. As medidas de condutividade elétrica (regiões de baixas temperaturas; 90-200 K) mostraram que os processos de condução se realizam via hopping de amplitude variável entre estados estendidos. Os parâmetros que caracterizaram este mecanismo, energia de ativação (Whopp) e amplitude hopping (Rhopp), foram obtidos mediante a teoria de percolação e o modelo de difusão. Obteve-se que, para as amostras CZTSe, a densidade de estados de defeito próximos do nível de Fermi do material, N(EF), está ao redor de, 3,403x10(18) cm-3 eV-1. Apresentou-se correlação entre parâmetros de depósito e propriedades elétricas. Observou-se influencia de parâmetros sobre a formação de fases no composto.

6.
Rev. Col. Bras. Cir ; 40(1): 23-31, jan.-fev. 2013. ilus, tab
Article in Spanish | LILACS | ID: lil-668845

ABSTRACT

OBJETIVO: Valorar la eficacia de la lipólisis-láser para corregir el volumen, flacidez y excedente cutáneo sin escisión. MÉTODOS: Prospectivamente, en 32 pacientes con ginecomastia, bajo anestesia tumescente y sedación se realizó lipólisis con láser de diodo 980nm, 15W en emisión continua, 8kJ a 12kJ de energía por mama. Externamente se utilizó aire frío para protección de la piel. Después se utilizó lipoaspiración convencional. No se emplearon drenajes pero si vendaje compresivo. Los pacientes evaluaron los resultados en una escala visual analógica. Dos médicos evaluaron los resultados por fotografías de antes y seis meses después, y midieron las areolas y contorno torácico. RESULTADOS: Veintitrés pacientes consideraron los resultados como Muy Bueno, siete Bueno y dos Regular. La retracción cutánea en la areola fue notable un mes después de la intervención y fue máxima a los seis meses. La valoración de los médicos fue 26 Muy Bueno, cinco Bueno y un Regular. No existieron quemaduras, isquemia, ni lesiones en areolas o pezón. CONCLUSIÓN: La liposucción asistida por láser es eficaz y de ejecución sencilla, poco traumática y permite una temprana reintegración a las actividades.


OBJECTIVES: To evaluate efficacy of laser lipolysis in the treatment of gynecomastia to correct breast volume, flaccidity and excess skin without its excision. METHODS: Prospectively, 32 patients with gynecomastia under tumescent anaesthesia and sedation underwent laser lipolysis with 980nm diode laser, 15W continuous emission and 8 to 12 kJ energy per breast. Externally cold air was used to protect the skin. No drainages were used but a compressive bandage. Patients evaluated results on a VAS scale. Two doctors evaluated results comparing before and 6 month after photographs and also measured the areola and chest diameter. RESULTS: Twenty three patients considered results as Very Good, 7 Good and 2 Fair Cutaneous retraction of the areola was noticeable one month after the surgery and was maximum 6 months after. Evaluation by doctors was 26 Very Good, 5 Good and 1 Fair. There were no burns, ischemia or lesions in areolas or nipples. CONCLUSION: Laser assisted liposuction is a simple and efficacious technique, barely traumatic and permits a rapid reincorporation to normal activitie.


Subject(s)
Adult , Humans , Male , Middle Aged , Young Adult , Gynecomastia/surgery , Laser Therapy , Lipectomy/methods , Prospective Studies , Skin , Treatment Outcome
7.
Univ. sci ; 15(1): 68-76, Jan.-Apr. 2010. ilus
Article in English | LILACS-Express | LILACS | ID: lil-637336

ABSTRACT

Polymer-based organic light-emitting diodes (OLEDs) with the structure ITO / PEDOT:PSS / MDMO-PPV / Metal were prepared by spin coating. It is known that electroluminescence of these devices is strongly dependent on the material used as cathode and on the deposition parameters of the polymer electroluminescent layer MDMO-PPV. Objective. In this work the effect of i) the frequency of the spin coater (1000-8000 rpm), ii) the concentration of the MDMO-PPV: Toluene solution, and iii) the material used as cathode (Aluminium or Silver) on the electrical response of the devices, was evaluated through current-voltage (I-V) measurements. Materials and methods. PEDOT:PPS and MDMO-PPV organic layers were deposited by spin coating on ITO substrates, and the OLED structure was completed with cathodes of aluminium and silver. The electric response of the devices was evaluated based on the I-V characteristics. Results. Diodes prepared with thinner organic films allow higher currents at lower voltages; this can be achieved either by increasing the frequency of the spin coater or by using concentrations of MDMO-PPV: Toluene lower than 2% weight. A fit of the experimental data showed that the diodes have two contributions to the current. The first one is attributed to parasitic currents between anode and cathode, and the other one is a parallel current through the organic layer, in which the carrier injection mechanism is mediated by thermionic emission. Conclusions. The results of the fitting and the energy level alignment through the whole structure show that PPV-based OLEDs are unipolar devices, with current mainly attributed to hole transport.


Se fabricaron diodos orgánicos emisores de luz (OLEDs) con la estructura ITO / PEDOT:PSS / MDMO-PPV / Metal mediante la técnica de spin coating. Es ampliamente conocido que la electroluminiscencia de estos diodos depende fuertemente del material usado como cátodo y también de los parámetros de crecimiento de la capa del polímero electroluminiscente MDMO-PPV. Objetivo. En este trabajo el efecto de i) la frecuencia del spin coater (1000-8000 rpm), ii) la concentración de la solución MDMO-PPV: Tolueno y iii) el material usado como cátodo (plata o aluminio) sobre la repuesta eléctrica de los dispositivos, fue evaluado a través de medidas de corriente-voltaje (I-V). Materiales y métodos. Películas delgadas de los materiales orgánicos PEDOT:PSS y MDMO-PPV fueron depositados por spin coating sobre sustratos de ITO, y la estructura del OLED fue terminada con cátodo de plata y aluminio. La respuesta eléctrica de los dispositivos fue evaluada a través de su característica I-V. Resultados. Los diodos fabricados con películas orgánicas más delgadas son los que suministran mayores corrientes a menores voltajes. Esto puede lograrse ya sea incrementando la frecuencia de rotación del spin coating o usando concentraciones de MDMO-PPV: Tolueno menores al 2% en peso. Un ajuste de los datos experimentales demostró que los diodos poseen contribuciones de una corriente parásita entre ánodo y cátodo, y otra corriente paralela en donde el mecanismo predominante de inyección de portadores a la capa orgánica es a través de emisión termoiónica. Conclusiones. El ajuste de los datos experimentales, junto con la posición de niveles de energía a través de la heteroestructura, demuestra que los OLEDs basados en derivados de PPV son dispositivos unipolares, en el que la corriente se atribuye principalmente a transporte de huecos.


Foram fabricados diodos orgânicos emissores de luz (OLEDs) com a estrutura de ITO / PEDOT: PSS / MDMO-PPV / metal, pela técnica de spin coating. É amplamente conhecido que a eletroluminescência destes diodos depende fortemente do material utilizado como cátodo, e também dos parâmetros de crescimento da camada de polímero eletroluminescente MDMO-PPV. Objetivo. Neste trabalho o efeito de i) a freqüência do spin coater (1000-8000 rpm), ii) a concentração da solução MDMO-PPV: Tolueno e iii) o material utilizado como cátodo (prata ou alumínio) sobre a resposta elétrica dos dispositivos, foi avaliado por medidas de corrente-voltagem (I-V). Materiais e métodos. Películas finas de materiais orgânicos PEDOT: PSS e MDMO-PPV foram depositadas por spin coating sobre substratos de ITO e a estrutura do OLED foi terminada com cátodo de prata e de alumínio. A resposta elétrica dos dispositivos foi avaliada pela sua característica I-V. Resultados. Os diodos feitos de películas orgânicas finas fornecem maiores correntes a menores voltagens. Isto pode ser conseguido, quer através do aumento da velocidade de rotação do spin coating ou usando concentrações de MDMO-PPV: Tolueno menores de 2% em peso. Um ajuste dos dados experimentais mostrou que os diodos têm uma contribuição de uma corrente parasita entre anodo e catodo, e outra corrente paralela, onde o principal mecanismo da injeção de portadores da camada orgânica é através da emissão termiônica. Conclusões. O ajuste dos dados experimentais, juntamente com a posição dos níveis de energia através da heteroestrutura, mostra que os OLEDs baseados em derivados de PPV são dispositivos unipolares, onde a corrente é atribuída principalmente ao transporte de ocos.