Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Rev. odontol. UNESP (Online) ; 47(6): 395-399, nov.-dez. 2018. tab
Article in English | LILACS, BBO | ID: biblio-985733

ABSTRACT

Introduction: There is a growing demand for aesthetic restorations and the polymerized composite resins are the most used material in these procedures. In order to achieve greater resistance to solubilization proper polymerization is required. Objective: Evaluate the influence of three photoactivation techniques, on sorption and solubility of three composite resins. Materials and methods: 90 test samples measuring 8 mm diameter and 1 mm thick were made and divided into 9 groups (n=10) of resins -Filtek Z350 XT, Tetric N-Ceram and IPS Empress Direct, each of them was polymerized with LED Bluephase, using the techniques: Conventional, Soft-Start (SS) and Pulse Delay (PD). Afterwards they were placed in desiccator with silica gel at 98.6 F and weighed daily until obtaining a constant mass (m1). Then they were immersed in deionized water for seven days and weighed again (m2). The test sample reconditioning was performed using the m1 procedure, until a constant mass (m3 ) was obtained. The sorption and solubility values were calculated and subjected to ANOVA test (two-way), followed by Tukey post hoc, p<0.05. Result: There were no statistically significant differences in sorption and solubility among the studied resins when photoactivation techniques were compared. For solubility analysis, statistically significant differences were observed among the materials. The results for composite resin Filtek Z350 XT presented higher statistical hybridization values than those of the other evaluated resins. Conclusion: The different forms of photoactivation had no influence on the sorption and solubility of the tested composite resins.


Introdução: Há uma crescente demanda por restaurações estéticas, sendo as resinas compostas polimerizadas o material mais utilizados nesses procedimentos. Visando uma maior resistência à solubilização, uma polimerização adequada é necessária. Objetivo: Avaliar a influência de três técnicas de fotoativação na sorção e na solubilidade de três resinas compostas. Material e método: Foram confeccionados 90 corpos-de-prova, com 8 mm de diâmetro e 1 mm de espessura, divididos em 9 grupos (n = 10) de resinas - Filtek Z350 XT, Tetric N-Ceram e IPS Empress Direct, cada uma elas polimerizada com LED Bluephase, utilizando as técnicas: Convencional, Soft-Start (SS) e Pulse Delay (PD). Posteriormente foram colocadas em dessecador com sílica gel a 98,6 F e pesadas diariamente até obtenção de massa constante (m1). Depois foram imersos em água desionizada durante sete dias e pesados ​​novamente (m2). O recondicionamento da amostra de teste foi realizado utilizando o procedimento m1, até que uma massa constante (m3) fosse obtida. Os valores de sorção e solubilidade foram calculados e submetidos ao teste ANOVA (two-way), seguido por Tukey post hoc, p <0,05. Resultado: Não houve diferenças estatisticamente significantes para sorção e solubilidade nas resinas estudadas quanto as técnicas de fotoativação. Para análise de solubilidade, foram observadas diferenças estatisticamente significantes entre os materiais. Os resultados para resina compostaFiltek Z350 XT apresentaram valores de hibridação estatísticos superiores aos das outras resinas compostas avaliadas. Conclusão: As diferentes formas de fotoativação não influenciaram a sorção e solubilidade das resinas compostas testadas.


Subject(s)
Solubility , Analysis of Variance , Composite Resins , Esthetics, Dental , Polymerization
2.
Braz. dent. sci ; 15(4): 29-35, 2012. tab
Article in English | LILACS, BBO | ID: lil-694456

ABSTRACT

Water contributes to the setting reaction of self-adhesive luting cements, however, it can also accelerate their degradation. Objectives: The aim of this study was to compare a self-adhesive resin luting cement to other resin-based and glass-ionomer luting materials with regards to water sorption (WS) and solubility (WSB). The tested null hypothesis was that there is no difference in respect to these properties among the materials. Material and methods: Eight specimens from each group (15 mm x 0.5 mm) were prepared from self-adhesive luting cements Biscem (BC) and RelyX Unicem (R), dual-cure cements Bifix (BF), Allcem (A) and Enforce (E), chemical-cure cements C&B (CB) and Cement Post (CP) and a glass-ionomer luting cement Meron C (M) as the control group. The dual-cure products were light-cured beneath an IPS Empress Esthetic ceramic disk (20 mm x 1.5 mm) and for the chemical reaction materials, a 15 min-interval was respected for removal from the mould. The WS and WSB were respectively calculated as (m2-m3/V) and (m1-m3/V). Mass values of m1, m2 and m3 were determined by cycles of desiccation, water-immersion and a new desiccation. For each property, the data was analyzed by one-criteria ANOVA and Tukey tests (p < 0.05). Results: The glass-ionomer cement presented the highest WS, followed by the self-adhesive luting cements. Other resin cements were less susceptible to WS. No materials differed from each other when the WSB was considered, except for the M, which presented the lowest WSB. Conclusions: Self-adhesive luting cements were more prone to WS since water is essential to their setting reaction. However, their WSB was similar to the other resin-based cements.


A água contribui para a reação de presa dos cimentos auto adesivos, entretanto pode acelerar a sua degradação. Objetivos: O objetivo deste estudo foi comparar cimentos auto adesivos a outros cimentos resinosos e material ionomérico em relação à sorção de água (WS) e solubilidade (WSB). A hipótese nula foi de que não há diferença em relação a essas propriedades entre os materiais. Material e métodos: Oito espécimes de cada grupo (15 mm x 0,5 mm) foram preparados dos cimentos auto adesivos Biscem (BC) e RelyX Unicem (R), cimentos duais Bifix (BF), Allcem (A) e Enforce (E), cimentos químicos C&B (CB) e Cement Post (CP) e um cimento ionomérico Meron C (M) como grupo controle. Os produtos duais foram fotoativados sob um disco cerâmico de IPS Empress Esthetic (20 mm x 1,5 mm) e para os materiais de reação química, um intervalo de 15 min foi respeitado para a remoção do molde. A WS e WSB foram respectivamente calculadas como (m2-m3/V) e (m1-m3/V). Valores de massa m1, m2 and m3 foram determinadas pelos ciclos de dessecação, imersão em água e nova dessecação. Para cada propriedade, os dados foram analisados pelos testes de ANOVA a um critério e Tukey (p < 0.05). Resultados: O cimento ionomérico apresentou a maior WS, seguido dos cimentos auto adesivos. Os demais cimentos resinosos foram menos suscetíveis a WS. Nenhum material diferiu do outro quanto a WSB foi considerada, exceto por M, que apresentou a menor WSB. Conclusões: Cimentos auto adesivos foram mais suscetíveis a WS, uma vez que a água é essencial para sua reação de presa. Entretanto, seu WSB foi similar aos demais cimentos resinosos.


Subject(s)
Glass Ionomer Cements , Resin Cements
3.
Braz. j. pharm. sci ; 47(1): 125-135, Jan.-Mar. 2011. graf, tab
Article in English | LILACS | ID: lil-586532

ABSTRACT

The aim of this study was to investigate the water sorption behavior of cellulose II:SiO2 composites and to determine the influence of silicification on this property. These composites were prepared by spray-drying at a cellulose II:SiO2 ratio of 98:2, 95:5, 90:10 and 80:20. The nonlinear models of Guggenheim-Anderson-de Boer (GAB), Generalized D'Arcy and Watt (GDW) and Hailwood & Horrobin (HH), were used for the characterization and analysis of the isotherms. The infrared and powder X-rays characterization showed no signs of chemical modification or change in the polymorphic form of cellulose II by SiO2. The parameters derived from these models indicated that only a 20 percent level of silicification was able to hinder the water sorption properties of cellulose. Silicon dioxide was the most hydrophobic material since it had a lower ability to form hydrogen bonds with water than cellulose II. This finding was reflected in a delayed compact disintegration time when high levels of silicification (20 percent) and compression pressures higher than 120 MPa were used.


O objetivo deste estudo é investigar o comportamento de sorção de água a partir de misturas de celulose II e SiO2 e determinar a influência da silicificação nesse processo. Estas misturas foram preparadas por nebulização (spray-drying) usando misturas de celulose II e SiO2 nas proporções de 98:2, 95:5, 90:10 e 80:20. Os modelos não-lineares de Guggenheim-Anderson-de Boer (GAB), "Generalized" D'Arcy e Watt (GDW) e Hailwood & Horrobin (HH) foram utilizados para caracterização e análise das isotermas. As misturas foram caracterizadas por infravermelho e raio-X e os resultados não mostraram indicativo de modificação química ou polimórfica da celulose II em combinação com SiO2. Os parâmetros derivados desses modelos indicaram que as propriedades de sorção de água da celulose foram prejudicadas apenas quando empregado um nível de silicificação de 20 por cento. O dióxido de silício foi o material mais hidrofóbico, provavelmente por possuir uma menor capacidade de formar pontes de hidrogênio com a água quando comparado com a celulose II. Este resultado foi refletido em redução no tempo de desintegração, especialmente quando altos níveis de silicificação (20 por cento) e força de compressão (acima de 120 Mpa) foram utilizados.


Subject(s)
Water/chemistry , Crystallization , Cellulose/analysis , Cellulose/adverse effects , Silicon Dioxide/adverse effects , Chemical Phenomena , Absorption , Adsorption , Cotton Fiber , Isotherm , Models, Chemical
SELECTION OF CITATIONS
SEARCH DETAIL