1.
Chinese Journal of Radiological Health ; (6): 392-400, 2022.
Article in Chinese | WPRIM | ID: wpr-965806

ABSTRACT

Objective To establish a sourceless efficiency calibration method by coupling Monte Carlo simulation with analytical calculation. Methods Monte Carlo simulation was used to calculate the point-to-point detection efficiency of specific detectors to establish a detection efficiency grid. The detection efficiency of point source, disc, cylindrical, beaker, spherical, U-tube and Marlin cup samples was analyzed using numerical integration method after detection efficiency grid interpolation. Results The above coupling method was used for sourceless efficiency calibration. Within the energy range of 0.2–3 MeV, the relative deviation of calibration between coupling method and Monte Carlo simulation was mostly less than 10%, the maximum relative deviation was 18.06%, and the computation time was reduced by at least 86%. The above coupling method was used for sourceless efficiency calibration of an HPGe detector manufactured by ORTEC for point source detection, which was in good agreement with the experimental calibration, and the relative deviations were less than 10%. Conclusion This method can be generalized and used in the sourceless efficiency calibration of HPGe, LaBr3, and NaI detectors.

2.
Chinese Journal of Radiological Health ; (6): 6-12, 2022.
Article in Chinese | WPRIM | ID: wpr-973569

ABSTRACT

Objective To optimize the Marinelli beaker with the simulation of Laboratory Sourceless Object Calibration Software (LabSOCS), to investigate the detection efficiency of HPGe detector in measuring noble gas, and to provide a reference for the measurement and optimization of noble gas effluent from nuclear power plants. Methods LabSOCS was used to establish a Marinelli beaker model to investigate the relationship of gamma ray detection efficiency of noble gas with gas components, gas density, size and volume of the Marinelli beaker, and the shape of source container. Results The gas components had little effect on the detection efficiency of the noble gas in the Marinelli beaker. The gas density had a relatively great effect on the detection efficiency of low-energy gamma ray. The Marinelli beaker of appropriate height and radius enabled the HPGe detector to get better measurement results. For the BE5030 HPGe detector, the highest detection efficiency of the Marinelli beakers of different volumes were observed at the location where the radius/height ratio was 0.7, and the optimal values of height and radius were given for the Marinelli beakers of different volumes. Conclusion Choosing Marinelli beaker of the appropriate size can improve the detection efficiency of noble gas in the effluent from nuclear power plants.

SELECTION OF CITATIONS
SEARCH DETAIL