Chinese Journal of Radiation Oncology ; (6): 504-507, 2016.
Article in Chinese | WPRIM | ID: wpr-494876

ABSTRACT

Objective To investigate the effects of spine region of interest (ROI),tracking range,and real-time image contrast ratio on the positioning errors of cyberknife.Methods The LTT dynamic phantom was used to develop a spine tracking plan and perform treatment,and the target positioning system was used to preset the phantom and obtain real-time preset image and positioning error.Based on the realtime preset image,spine ROI,tracking range,and real-time image contrast ratio were changed to observe the changes in positioning error and related parameters.Pearson correlation analysis was performed.Results The change in tracking range did not change the positioning error in spine tracking,and tracking range was not correlated with positioning error (R =0,P =1).The changes in ROI and image contrast ratio did not affect the translation error,but affected the rotation error,especially the rotation error in left-right direction (r =0.533 and 0.693,P=0.002 and 0.026).The image contrast ratio had the most obvious effect,with an amplitude of variation up to 2.2°.Conclusions The change in tracking range does not affect the positioning errors in spinal tracking,but the changes in ROI and image contrast ratio can cause varying degrees of changes in positioning errors,which should be taken seriously in cyberknife treatment.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 133-135, 2014.
Article in Chinese | WPRIM | ID: wpr-444859

ABSTRACT

Objective To explore the relationship of X-ray exposure parameters and false-node rate during image-guidance treatment with CyberKnife spine tracking.Methods Using spine tracking planning on a chest phantom,several combinations of X-ray exposure parameters were used to locate.The false-node ratio and the surface absorbed dose were investigated and the radiation dose was optimized.Results The false-node ratio and surface absorbed radiation dose decreased when the X-ray exposure parameters increased until they saturated.In the range of ≤5.0% false-node rate,the surface absorbed radiation dose was 0.11,0.26 mGy,and 0.31-0.46 mGy,when the false-node rate was 2.77%,1.07%and 1.0%,respectively.Conclusions In image-guided treatment of CyberKnife,the radiation dose would be optimized,and the patient's radiation dose would be reduced greatly,which is important to protect the patients.

3.
Chinese Journal of Radiation Oncology ; (6): 36-38, 2013.
Article in Chinese | WPRIM | ID: wpr-432168

ABSTRACT

Objective To investigate the impacts of fiducial tracking and X-sight tracking on the short-term therapeutic effect of cybernikife in the treatment of lung cancer.Methods Retrospective analysis was performed on 64 lung cancer patients (72 lesions),including 40 primary tumor patients (41 lesions) and 24 metastatic tumor patients (31 lesions),who were treated with cyberknife.Fiducial tracking was used for 45 lesions,while X-sight tracking was used for 27 lesions.The planning target volume was covered by 70%-94% (median 80%) isodose contour.The irradiation dose was 60 Gy/3 fractions.The relationship between short-term therapeutic effect and tracking method was determined.Results Overall,the lesions undergoing fiducial tracking showed significantly higher response rate than those undergoing X-sight tracking (93% vs.74%,x2 =6.84,P=0.033),and so was in lower lung lesions (15% vs.7%,x2 =7.18,P=0.028).But the two tracking methods achieved similar effects in upper lung lesions (28% vs.12%,x2 =2.36,P =0.310).In the lesions with treatment volumes smaller than 15 cm3,the fiducial tracking achieved significantly higher response rate than the X-sight tracking (25 % vs.12%,x2 =6.53,P =0.038),but the two tracking methods achieved similar effects in the lesions with treatment volumes not smaller than 15 cm3 (17% vs 8%,x2 =1.57,P =0.460).Overall,the lesions undergoing X-sight tracking had significantly highertreatment failure rate than fiducial tracking (1 9 % vs.2 %,x2 =6.33,P =0.021).Conclusions Different tracking methods may lead to different therapeutic effects of cyberknife in the treatment of lung cancer,which are related to lesion location and treatment volume.