1.
The Journal of Korean Academy of Prosthodontics ; : 51-62, 2006.
Article in Korean | WPRIM | ID: wpr-129494

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the pattern and the magnitude of stress distribution in the supporting tissues surrounding three different types of implants(ITI, 3i, and Bicon implant system). MATERIAL AND METHOD: Photoelastic models were made with PL-2 resin(Measurements Group, Raleigh, USA) and three implants of each kind were placed in the mandibular posterior edentulous area distal to the canine . For non-splinted restorations, individual crowns were fabricated on three titanium abutments. For splinted restorations, 3-unit fixed partial dentures were fabricated. Photoelastic stress analyses were carried out to measure the fringe order around the implant supporting structure under simulated loaded conditions(15 lb, 30 lb). CONCLUSION: The results were as follows; 1. Regardless of the implant design, stresses were increased in the apex region of loaded implant when non-splinted restorations were loaded. While relatively even stress distribution occurred with splinted restorations. Splinting was effective in the second implant. 2. Strain around Bicon implant were lower than those of other implants, which confirmed the splinting effect. The higher the load, the more the stress occurred in supporting tissue, which was most obvious in the Bicon system. 3. Stress distribution in the supporting tissue was favorable in the ITI system, while the other side of 3i system tended to concentrate the stress in some parts.


Subject(s)
Crowns , Denture, Partial, Fixed , Splints , Titanium
2.
The Journal of Korean Academy of Prosthodontics ; : 51-62, 2006.
Article in Korean | WPRIM | ID: wpr-129479

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the pattern and the magnitude of stress distribution in the supporting tissues surrounding three different types of implants(ITI, 3i, and Bicon implant system). MATERIAL AND METHOD: Photoelastic models were made with PL-2 resin(Measurements Group, Raleigh, USA) and three implants of each kind were placed in the mandibular posterior edentulous area distal to the canine . For non-splinted restorations, individual crowns were fabricated on three titanium abutments. For splinted restorations, 3-unit fixed partial dentures were fabricated. Photoelastic stress analyses were carried out to measure the fringe order around the implant supporting structure under simulated loaded conditions(15 lb, 30 lb). CONCLUSION: The results were as follows; 1. Regardless of the implant design, stresses were increased in the apex region of loaded implant when non-splinted restorations were loaded. While relatively even stress distribution occurred with splinted restorations. Splinting was effective in the second implant. 2. Strain around Bicon implant were lower than those of other implants, which confirmed the splinting effect. The higher the load, the more the stress occurred in supporting tissue, which was most obvious in the Bicon system. 3. Stress distribution in the supporting tissue was favorable in the ITI system, while the other side of 3i system tended to concentrate the stress in some parts.


Subject(s)
Crowns , Denture, Partial, Fixed , Splints , Titanium
3.
The Journal of Korean Academy of Prosthodontics ; : 412-424, 2004.
Article in Korean | WPRIM | ID: wpr-176166

ABSTRACT

STATEMENT OF PROBLEM: Several prosthetic options are available for the restoration of multiple adjacent implants. A passively fitting prosthesis has been considered a prerequisite for the success and maintenance of osseointegration. Passivity is a particular concern with multiple implants because of documented inaccuracies in the casting and soldering process. One way to avoid this problem is to restore the implants individually, however, the restorations of individual adjacent impants requires careful adjustment of interproximal contacts. PURPOSE: The purpose of this study was to compare the stress distribution pattern and amount surrounding Bicon implants with individual crowns and splinted restorations. MATERIAL AND METHOD: A photoelastic model of a human partially edentulous left mandible with 3 Bicon implants(4*1 mm) was fabricated. For non-splinted restorations, individual crowns were fabricated on 3 abutments (4.0*6.5 mm, 0 degree, 2.0 mm post, Bicon Inc., Boston, USA) After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal (8 micrometershim stock drags without tearing), medium(40 micrometer), and heavy(80 micrometer). Splinted 3-unit fixed partial dentures were fabricated and cemented to the model. Changes in stress distribution under simulated non-loaded and loaded conditions(7.5, 15, 30 lb) were analyzed with a circular polaricope. RESULTS: 1. Stresses were distributed around the entire body of fin in Bicon implants. 2. Splinted restorations were useful for distribution of stress around implants especially with higher loads. 3. By increasing the contact tightness between the individually restored three implants, the stress increased in the coronal portion of implants. CONCLUSIONS: Ideal adjustment of the contact tightness was important to reduce the stresses around individually restored Bicon implants.


Subject(s)
Humans , Crowns , Denture, Partial, Fixed , Mandible , Osseointegration , Prostheses and Implants , Splints
4.
The Journal of Korean Academy of Prosthodontics ; : 425-442, 2004.
Article in Korean | WPRIM | ID: wpr-176165

ABSTRACT

STATEMENT OF PROBLEM: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. PURPOSE: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. MATERIAL & METHODS: Three Endopore implants(4.1*9 mm) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal(8 micrometershim stock drags without tearing), medium(40 micrometer), and heavy(80 micrometer). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. RESULTS: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. CONCLUSIONS: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.


Subject(s)
Crowns , Denture, Partial, Fixed , Prostheses and Implants , Splints , Titanium