Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 27-31, 2020.
Article in Chinese | WPRIM | ID: wpr-856415

ABSTRACT

Objective: To investigate the application and effectiveness of self-made spring plate in surgical treatment of acetabular posterior wall fracturejavascript:void(0)s. Methods: Between June 2013 and June 2017, 38 patients with acetabular posterior wall fractures were treated. There were 27 males and 11 females with an average age of 53 years (range, 28-68 years). The injury caused by traffic accident in 18 cases, falling from height in 15 cases, and tumble in 5 cases. There were 4 cases of simple posterior wall fracture, 18 cases of posterior wall fracture with posterior dislocation of hip joint, 10 cases of posterior wall fracture with posterior column fracture, and 6 cases of posterior wall fracture with transverse fracture. The time from injury to admission was 1-4 days (mean, 2.5 days). The time from injury to operation was 4-8 days (mean, 5 days). After fracture reduction via the Kocher-Langenbeck approach (35 cases) or the combined ilioinguinal approach (3 cases), the spring plate was used to press the posterior wall fracture, and then the reconstruction plate was pressed against the spring plate and fixed to the posterior column. Results: All the incisions healed by first intention. All patients were followed up 12-36 months (mean, 28 months). Five cases of post-traumatic sciatic nerve injury and 2 cases of sciatic nerve injury caused by traction during operation were fully recovered at 3 months after operation. The imaging examination showed that all the fractures healed. The fracture healing time was 10-16 weeks (mean, 12 weeks). There was no ruptures or failures of internal fixation during the follow-up period. There were 2 cases of femoral head necrosis, 1 case of traumatic arthritis, and 1 case of osteomyositis at last follow-up. The hip joint function was rated as excellent in 27 cases, good in 5 cases, fair in 2 cases, and poor in 4 cases according to the Harris scores at 12 months after operation. Conclusion: For the acetabular posterior wall fracture, it has the advantages of easy to use and reliable fixation that the posterior wall fracture is fixed with spring plate firstly, and the spring plate is pressed to fix the posterior column with the reconstruction plate finally.

2.
Journal of the Korean Fracture Society ; : 19-25, 2016.
Article in Korean | WPRIM | ID: wpr-98201

ABSTRACT

PURPOSE: We applied internal fixation using a spring plate against an acetabular posterior wall fracture including small fragments and then evaluated the clinical and radiological results and want to understand the usefulness of the spring plate. MATERIALS AND METHODS: Fifteen patients in whom fixation was difficult using leg screws or a metal plate because of a small bone fragment, in patients with posterior wall acetabular fractures who presented in our hospital since August of 2011 to March of 2014 were enrolled. The mean age was 42.6 years (range 24-54 years) with relatively young patients, and they were followed-up for at least one year. We analyzed the rate of reduction after surgery using the classification of Matta in radiographs, and the classification of Borrelli in 3-dimensional computed tomography (CT) and clinical results were evaluated using the clinical grading system. RESULTS: There were five cases of anatomical reduction, 9 cases of imperfect reduction, and 1 case of unsatisfactory reduction according to the classification of Matta. Except for one case during the follow-up period, the union of bone was successful without failure of fixation and the clinical results were 6 cases of excellence, 8 cases of good, and 1 case of failure. Articular displacement was also evaluated in postoperative CT scan according to Borrelli's criteria. The mean of gap and step off was 2.04 mm, 1.3 mm. CONCLUSION: Use of leg screw fixation and so on in posterior wall fractures including a small fragment of the acetabular rim is not easy. However the method using spring plate fixation enables relatively accurate reduction and fixation for a small fragment and the clinical outcome showed satisfactory results.


Subject(s)
Humans , Acetabulum , Classification , Follow-Up Studies , Leg , Pelvis , Tomography, X-Ray Computed
3.
Journal of the Korean Fracture Society ; : 64-68, 2010.
Article in Korean | WPRIM | ID: wpr-123324

ABSTRACT

PURPOSE: Unstable distal clavicle fractures should be treated surgically but may be difficult in firm fixation because of small distal fragment. Although a variety of fixation methods have been currently used, none of the methods seem to be firm fixation and little pain. We present a new technique using a spring plate which was modified from one third tubular plate and report the early results. MATERIALS AND METHODS: Modified spring plate was made from one third tubular plate and the distal hole of the plate was cutting and sharpened by rasp. The sharp edge was bent just like an animal claw (C shape). Between May 2007 and June 2009, a total of six patients with distal clavicle fracture were treated using modified spring plate. A sling was applied in the immediate post operative period for six weeks and exercises were started immediately. RESULTS: Union was achieved in all cases with excellent results without complication (mean Constant score, 96). All patients had returned to ordinary daily activities but mild limitation of abduction (150 degrees ) by seven weeks after surgery. After six months, the plate was removed. CONCLUSION: The modified spring plate has provided stable fixation for unstable distal clavicle fixation without disturbance to the acromioclavicular joint, subacromial space, or rotator cuff.


Subject(s)
Animals , Humans , Acromioclavicular Joint , Clavicle , Exercise , Hoof and Claw , Rotator Cuff
4.
Journal of the Korean Fracture Society ; : 159-165, 2009.
Article in Korean | WPRIM | ID: wpr-125806

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the surgical outcomes of isolated greater tuberosity fractures of the proximal humerus fixed with the spring plates. MATERIALS AND METHODS: Fourteen patients who could be followed up at least 1 year after the surgical treatment of isolated greater tuberosity fracture were evaluated. Their mean age was 51 years (range, 25~73 years). The deltopectoral approach and fixation with the spring plate were performed in all cases. The spring plate was used in all cases. In some circumstances, sutures incorporating the rotator cuff, interfragmentary screw or tension band wire were added. We evaluated the clinical outcomes using UCLA scoring system and KSS (Korean Shoulder Score). RESULTS: The mean UCLA score was 29.8 and the mean KSS was 89.4. The average time of bony union was 10.2 weeks (range, 7~14 weeks) after the surgery, including 1 case that was performed the secondary operation due to metal failure. The shoulder stiffness were observed in 4 cases and one case of infection was treated well without operation. CONCLUSION: In the treatment of isolated greater tuberosity fractures of the proximal humerus, the spring plates fixation can be a good surgical option providing reliable functional results.


Subject(s)
Humans , Humerus , Rotator Cuff , Shoulder , Sutures
SELECTION OF CITATIONS
SEARCH DETAIL