1.
China Medical Equipment ; (12): 11-14,15, 2017.
Article in Chinese | WPRIM | ID: wpr-606387

ABSTRACT

Objective:To establish the X-ray standard was used to calibrate Hp(3) dosimeter in order to satisfy the requirement of eye-lens dose equivalents for the radiological occupational staff.Methods:The conventional values (Hp(3)) on the reference point of the narrow beams of X-ray fields were obtained by means of the product of air kerma (Kair) and the conversion coefficients (hp(3,ɑ)) recommended by ICRP116 recommendation. And these researches can be used by standard ionization chamber dosimeter. Finally, provided the conventional true value Hp(3) at calibrate point.Results:The standards and calibration program of calibrations eye-lens dose equivalent dosimeter were established under the X-ray radiation field. The detection error between slab phantom recommended by ISO and head phantom recommended by the 116th publication of ICRP was lower when the TLD was used to detect result.Conclusions:The standards for calibration Hp(3) dosimeters can satisfy the requirement of calibration for radiological occupational staff. It also provides theoretical foundation for detection data that assessed Hp(3) dosimeters and then improves trace ability and reliability of detection data of Hp(3) in national radiation supervision and inspection network.

2.
China Medical Equipment ; (12): 8-10,11, 2014.
Article in Chinese | WPRIM | ID: wpr-598796

ABSTRACT

Objective:According to the requirement of ISO and National Standard, new X-ray environmental standard for the calibration of environmental dosimeter was established in Beijing SSDL. Methods:Half value layer and air kerma dose-rate was determined in the X-ray environmental qualities by a standard dosimeter. Results: The technical requirement of ISO and National Standard are met within 2% for the X-ray environmental standard qualities in Beijing SSDL. Conclusion:The X-ray standard radiation field can be used for the calibration of environmental dosimeters and experiment of research.

3.
Chinese Journal of Laboratory Medicine ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-584056

ABSTRACT

Objective To study suitability of a series of lyophilized serum with definitive HBV DNA value in fluorescence quantitative COBAS Amplicor HBM kit and a sample with 106 copies/ml HBV DNA was prepared, and sent to various manufactures which would be asked to detect the samples using their own kits. Then a calibration curves from CT values of the series to the corresponding concentrations was compared with that obtained from the external standard-calibration curve with the manufactures series. Results The standard-calibration curve with the series of lyophilized serum showed an excellent correlation (