Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Arq. bras. oftalmol ; 86(4): 314-321, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447380

ABSTRACT

ABSTRACT Purpose: To compare strip meniscometry and Schirmer tear test 1 results and tear film breakup time between dogs with normal eyes and dogs diagnosed with keratoconjunctivitis sicca. Methods: One-hundred fifty-six eyes of 78 dogs, 88 normal eyes, and 68 eyes diagnosed with keratoconjunctivitis sicca were included in the study. The tests were performed in the following sequence: Schirmer tear test 1 was used to allocate the dogs to the normal or keratoconjunctivitis sicca group, followed by the strip meniscometry test and tear film breakup time measurement. Results: The results (mean ± standard deviation) of the tests in the normal group were as follows: Schirmer tear test 1, 22.75 ± 3.88 mm/min; strip meniscometry test, 10.01 ± 2.35 mm/5 sec; and tear film breakup time, 25.82 ± 5.47 sec. In the keratoconjunctivitis sicca group, the results were as follows: Schirmer tear test 1, 6.10 ± 4.44 mm/min; strip meniscometry test, 3.03 ± 2.62 mm/5 sec; and tear film breakup time, 10.78 ± 4.23 sec. The Spearman correlation coefficient in the keratoconjunctivitis sicca group was very high, with a significant difference between the strip meniscometry test and Schirmer tear test 1 (r=0.848, p<0.001), and moderate and significant between the strip meniscometry test and tear film breakup time (r=0.773, p<0.001). The cutoff for the strip meniscometry test for keratoconjunctivitis sicca was 7.0 mm/5 sec. Keratoconjunctivitis sicca was suspected when the values were <10 mm/5 sec. Conclusions: This study provided strip meniscometry test values from dogs with normal eyes and eyes with keratoconjunctivitis sicca, with high sensitivity and specificity compared with those of the Schirmer tear test 1. In the future, the strip meniscometry test may be another important quantitative test and could complement the gold standard Schirmer tear test for the diagnosis of keratoconjunctivitis sicca in dogs, an excellent animal model for the study of the disease.


RESUMO Objetivo: Comparar o teste de meniscometria em tira com o teste lacrimal de Schirmer 1 e o tempo de ruptura do filme lacrimal, em cães com olhos normais e cães com diagnóstico de ceratoconjuntivite seca. Métodos: Cento e cinquenta e seis olhos de 78 cães, 88 olhos normais e 68 olhos com diagnóstico de ceratoconjuntivite seca. Os testes foram realizados na seguinte sequência: o teste lacrimal de Schirmer 1 foi utilizado para alocar os cães no grupo normal ou no grupo ceratoconjuntivite seca, seguido pelo teste de meniscometria em tira e tempo de ruptura do filme lacrimal. Resultados: As médias e desvios-padrão para os olhos normais foram: teste lacrimal de Schirmer 1 = 22,75 ± 3,88 mm / min; teste de meniscometria em tira = 10,01 ± 2,35 mm / 5 seg; tempo de ruptura do filme lacrimal = 25,82 ± 5,47 seg; e para os olhos do grupo ceratoconjuntivite seca foram: teste lacrimal de Schirmer 1 = 6,10 ± 4,44 mm / min; teste de meniscometria em tira = 3,03 ± 2,62 mm / 5 seg; tempo de ruptura do filme lacrimal = 10,78 ± 4,23 seg. O teste de correlação de Spearman no grupo ceratoconjuntivite seca foi muito alto, com diferença significativa entre teste de meniscometria em tira e teste lacrimal de Schirmer 1 (r=0,848, p<0,001), moderada e significativa entre teste de meniscometria em tira e tempo de ruptura do filme lacrimal (r=0,773, p<0,001). O cut-off para teste de meniscometria em tira para ceratoconjuntivite seca foi identificado em 7,0 mm / 5 seg, valores abaixo de 10 mm / 5 seg podem ser considerados suspeitos para KCS. Conclusões: Este estudo forneceu valores de teste de meniscometria em tira em olhos normais e com ceratoconjuntivite seca em cães, revelando alta sensibilidade e especificidade em comparação com o teste lacrimal de Schirmer 1. No futuro, o teste de meniscometria em tira pode ser outro teste quantitativo importante e pode complementar o teste lacrimal de Schirmer padrão ouro para o diagnóstico de ceratoconjuntivite seca em cães, um excelente modelo animal para o estudo de ceratoconjuntivite seca.

2.
International Eye Science ; (12): 517-521, 2023.
Article in Chinese | WPRIM | ID: wpr-964260

ABSTRACT

AIM:To explore the correlation and consistency of three tear assessment methods in the diagnosis of dry eye, which include the Schirmer Ⅰ test(SⅠt), tear meniscus height(TMH)measurement and a new generation of tear detection technology-Strip meniscometry tube(SMTube).METHODS: A diagnostic test study. A total of 183 dry eye outpatients(183 right eyes)in the Dry Eye Center of Henan Eye Hospital were enrolled from May to June 2021. The SⅠt, TMH and SMTube were performed on all patients, and the correlation and consistency of the measurement results were analyzed.RESULTS:The ocular surface disease index(OSDI)of all included patients was 43.75(31.25, 58.33), noninvasive breakup time(NIBUT)was 7.26(4.97, 9.37)s, and the results of SⅠt, TMH and SMTube were 6(2, 12)mm/5min, 0.18(0.14, 0.22)mm and 5(3,8)mm/5s, respectively; The results of correlation analysis: TMH was positively correlated with SMTube(rs=0.751, P<0.001), however, SⅠt had no correlation with TMH(rs=0.139, P=0.060)and SMTube(rs=0.019, P=0.799). The results of consistency analysis: TMH showed good consistency with SMTube(Kappa=0.794, P=0.044), however, SⅠt showed poor consistency with TMH(Kappa=0.271, P=0.074)and SMTube(Kappa=0.193, P=0.070)respectively.CONCLUSION:SMTube is a new, simple and convenient tool for evaluating tear volume. It has a good correlation and consistency with TMH measurement results. Therefore, it can replace TMH measurement, but cannot replace SⅠt in clinical application.

3.
Ciênc. rural (Online) ; 49(11): e20181002, 2019. tab, graf
Article in English | LILACS | ID: biblio-1045262

ABSTRACT

ABSTRACT: This study aimed to describe strip meniscometry test values for Amazona aestiva (turquoise-fronted amazon), Ara ararauna (blue-and-yellow macaw) and Caiman latirostris (broad-snouted caiman). Twenty-one Amazona aestiva and 11 Ara ararauna, healthy, adults of unknown sex, and 37 healthy adult Caiman latirostris (27 males and 10 females), were used in this investigation. All animals were manually restrained and I-Tear® Test strip was inserted for 5 s at the edge of the lower tear meniscus, without touching the eyelid or ocular surface, immediately followed by measurement (millimeter per 5 seconds). No differences were reported between left and right eyes for Amazona aestiva (P = 0.824), Ara ararauna (P = 0.262) and Caiman latirostris (P = 0.679). Median and confidence interval were 2.0 (2.25-3.56) mm/5s for Amazona aestiva, 3.0 (2.93-4.15) mm/5s for Ara ararauna and 3.0 (2.55-4.90) mm/5 s for Caiman latirostris. These values for strip meniscometry tear test can be used as parameters for each species and may be helpful for diagnosis and treatment of tear-production disorders in birds and reptiles.


RESUMO: O objetivo deste estudo foi descrever os valores do teste de meniscometria lacrimal para Amazona aestiva (papagaio-verdadeiro), Ara ararauna (arara-canindé) e Caiman latirostris (jacaré-de-papo-amarelo). Vinte e um Amazona aestiva, 11 Ara ararauna adultos, de sexo desconhecido, e 37 Caiman latirostris adultos (27 machos e 10 fêmeas), foram utilizados nesta investigação. Todos os animais foram contidos manualmente e uma tira do I-Tear® test foi inserida por 5 segundos na borda do menisco inferior, sem tocar a pálpebra ou a superfície ocular, e imediatamente mensurada (milímetro por 5 segundos). Não foram encontradas diferenças entre os olhos esquerdos e direitos para Amazona aestiva (P = 0,824), Ara ararauna (P = 0,262) e Caiman latirostris (P = 0,679). Mediana e intervalo de confiança foram de 2,0 (2,25-3,56) mm/5 s para Amazona aestiva, 3,0 (2,93-4,15) mm/5 s para Ara ararauna e 3,0 (2,55-4,90) mm/5 s para Caiman latirostris. Estes valores para o teste de meniscometria podem ser utilizados como parâmetros para estas espécies e podem ser úteis para diagnosticar e tratar distúrbios de produção lacrimal em aves e répteis.

4.
Journal of the Korean Ophthalmological Society ; : 1521-1526, 2016.
Article in Korean | WPRIM | ID: wpr-77274

ABSTRACT

PURPOSE: To evaluate the efficacy of strip meniscometry test for dye eye syndrome (DES) by measuring the correlation between strip meniscometry and conventional test measurements. METHODS: All subjects were examined using the Schirmer test, tear breakup time (TBUT) and strip meniscometry using SMTube (Echo Electricity Co., Ltd., Fukushima, Japan). Tear meniscus height (TMH), tear meniscus depth (TMD) and tear meniscus area (TMA) were measured using Fourier-domain optical coherence tomography. The DES group (n = 46 eyes) was compared with the normal group (n = 30 eyes) and correlation was assessed using Spearman's correlation coefficient. RESULTS: Strip meniscometry measurement was significantly correlated with Schirmer score (r = 0.6080, p < 0.01), TBUT (r = 0.5980, p < 0.01), TMH (r = 0.6210, p < 0.01), TMD (r = 0.6080, p < 0.01) and TMA (r = 0.6370, p < 0.01). Strip meniscometry was significantly lower in the DES group (4.58 ± 1.94 mm) than the normal group (7.07 ± 2.61 mm, p < 0.05). CONCLUSIONS: Strip meniscometry was significantly correlated with other conventional test measurements for dry eye syndrome. Strip meniscometry is less time consuming and a less invasive method than the Schirmer test. Strip meniscometry could be an efficient tool to evaluate patients with dry eye syndrome in a clinical setting.


Subject(s)
Humans , Diagnosis , Dry Eye Syndromes , Electricity , Methods , Tears , Tomography, Optical Coherence
SELECTION OF CITATIONS
SEARCH DETAIL