Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Article in Chinese | WPRIM | ID: wpr-505691

ABSTRACT

Objective To explore the relationship between sudomotor function and peripheral artery disease (PAD),and to evaluate the effectiveness of sudomotor function testing to screen diabetic patients at high risk of PAD comparing to ankle-brachial index (ABI) and toe-brachial index (TBI).Methods A total of 263 diabetes mellitus (DM) outpatients in the 306th Hospital of PLA from August 2014 to April 2015 were enrolled in the study.ABI and TBI were measured by the Doppler method.Sudomotor function was evaluated by measuring the electrochemical skin conductance (ESC) of the hands and feet using the Sudoscan instrument.Cardiovascular autonomic neuropathy (CAN) was assessed and recorded as cardiac autonomic neuropathy risk-score (CAN-RS) by Sudoscan.Results ESC values of the feet and hands were positively correlated with ABI and TBI.The diabetes patients with abnornal ABI and TBI had significantly lower hand ESC [(45.63±12.87) μS vs.(68.10±17.40) μS,(59.17±19.58) μS vs.(68.57±17.11) μS;P< 0.05] and feet ESC [(44.54±25.48) μS vs.(70.92±19.46) μS,(59.21±24.52) μS vs.(71.71±19.02) μS;P< 0.05],and higher CAN-RS[(49.17± 15.41)% vs.(36.33±16.25)%,(44.90±16.09)% vs.(35.39±16.05)%;P< 0.05],than diabetes patients with normal ABI and TBI.Using ABI as the gold standard,the areas under the receiver operating characteristics (ROC) curve of the diagnostic performance of hands ESC,feet ESC and CAN-RS to identify PAD were 0.87,0.84 and 0.74,respectively (P<0.001).Conclusion Sudomotor function testing can be helpful and beneficial to identify PAD in patients with diabetes.

2.
Article in Chinese | WPRIM | ID: wpr-424266

ABSTRACT

Objective To assess the efficacy of Ezscan in evaluating the risk of cardiac autonomic neuropathy (CAN) in diabetes. Methods This study included 144 patients with diabetes. Their serum lipid profile and HbA1c were determined. The heart rate variability was assessed by Holter, and the cardiac autonomic neuropathy by classic experiments. Meanwhile, Ezscan was carried out. Results There was a positive correlation between low frequency (LF) measurements by Holter and Ezscan score( r=0. 39, P<0. 01 ), so did LF/HF and Ezscan score( r=0. 28, P<0. 01 ). Correlations between Ezscan score and other Holter parameters were weaker. There was no correlation between HbA1c and LF measurements. In patients with positive classic experiments, the sensitivity and specificity of Ezscan were 58. 3% and 57.8% respectively. Conclusions Ezscan test is a valuable screening procedure for detecting diabetic complications. It is more facilitative and takes shorter time than does the classical autonomic function assessment.

SELECTION OF CITATIONS
SEARCH DETAIL