Rev. bras. oftalmol ; 68(1): 7-12, Jan.-Feb. 2009. graf, tab
Article in English | LILACS | ID: lil-508918

ABSTRACT

PURPOSE: The aim of the present study is to assess central corneal edema and visual recovery after cataract surgery performed according to two technologies: conventional ultrasonic and liquefaction (Aqualase®). METHODS:This is a prospective contralateral study in wich 20 patients with comparable preoperative conditions were submitted to cataract surgery were evaluated. Preoperative assessment involved complete ophthalmological examination and the study included patients with bilateral cataracts up to grade 2, according to the Lens Opacity Classification System II. The same cristaline fracture technique was used in all cases, and surgical procedures were performed by the same experienced surgeon, using two technologies: liquefaction or conventional phacoemulsification. Postoperative central corneal edema was measured by corneal optical pachymetry (Orbscan II®) on the 1st, 3rd, 7th and 10th postoperative days. RESULTS:None of the 20 patients submitted to surgery was lost during the postoperative follow-up or excluded from the analysis. On the first postoperative, the visual acuity average was 0.031 logMAR in the Aqualase® group and 0.043 logMAR in the conventional surgery group. No statistical difference was detected in the assessment of visual acuity throughout the postoperative period. Central corneal pachymetry varied from 543.93 + 34.69 preoperatively to 545.08 ± 25.67 on the last day of follow-up in the Aqualase® group, and from 543.13 + 30.62 to 536.08 + 34.89 in the conventional technique group, without statistical significance. CONCLUSION:This study suggests that both techniques are equally effective for surgery on lenses with grade I or II cataract, and that they provide similar results in terms of visual recovery and central corneal edema.


OBJETIVO: Avaliar o edema corneano central e a recuperação visual após cirurgia de catarata realizada através de duas tecnologias: ultrassônica convencional e liquefação (Aqualase®). MÉTODOS: Estudo retrospectivo com análise contralateral, onde 20 pacientes se submeteram à facectomia sob condições pré-operatórias comparáveis. A avaliação pré-operatória envolveu exame oftalmológico completo com graduação da catarata de acordo com o Lens Opacity Classification System II, e foram incluídos no estudo pacientes com catarata nuclear bilateral até grau II. A mesma técnica cirúrgica foi realizada em todos os casos pelo mesmo cirurgião, utilizando as duas tecnologias: liquefação e facoemulsificação convencional. As medidas do edema corneano pós-operatório foram realizadas com paquímetro óptico corneano (Orbscan II®) nos dias 1, 3, 7 e 10 de pós-operatório. RESULTADOS: Nenhum dos pacientes inicialmente inscritos no estudo foi excluído ou perdido durante o seguimento. No primeiro dia pós-operatório a acuidade visual média foi de 0.031 logMAR no grupo de Aqualase e 0.043 logMAR no grupo convencional. Nenhuma diferença estatisticamente significativa foi detectada na análise de acuidade visual durante o período pós-operatório. A paquimetria corneana central variou de 543.93 + 34.69 no pré-operatório para 545.08 ± 25.67 no último dia de acompanhamento no grupo de Aqualase e de 543.13 + 30.62 para 536.08 + 34.89 no grupo convencional, sem diferença estatisticamente significativa. CONCLUSÃO: O estudo sugere que as duas técnicas são igualmente eficaz para as cirurgias nucleares graus I e II, além de apresentarem resultados similares em relação ao edema corneano central e à recuperação visual.

2.
Rev. bras. oftalmol ; 66(5): 309-314, set.-out. 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-481157

ABSTRACT

OBJETIVOS: Comparar a medida da espessura corneana central (ECC) obtida pelo paquímetro óptico Haag-Streit e a paquimetria ultrassônica DGH 500 (PachetteTM). MÉTODOS: Foram avaliados, 200 olhos de 100 pacientes utilizando-se o paquímetro óptico (PO) e o ultrassônico (PU). As medidas foram realizadas na área central da córnea, respeitando a área dos 3 mm, em pacientes com córneas normais, em olhos hipermétropes, emétropes e míopes, excluindo doenças oculares, usuários de lentes de contato ou submetidos às cirurgias. RESULTADOS: A média geral da ECC medida pelo PO foi 603,8± 32,6µm, e 568,2±40,5 µm pelo PU. As comparações entre as medidas dos dois aparelhos foram realizadas ao nível de 5 por cento de significância e a diferença entre os dois aparelhos foi 35,7±26,4 µm (p=0,0000), indicando diferença significativa entre os métodos utilizados. Não houve diferença estatística entre olhos hipermétropes, emétropes e míopes usando o PU. CONCLUSÃO: A medida da ECC é superestimada pelo PO quando comparada com o PU.


PURPOSE: To compare measurements of central corneal thickness obtained using a Haag-Streit optic pachymeter and a DGH 500 (Pachette Ttm ) ultrasonic pachymeter in normal patients. METHODS: An evaluation was made of 200 eyes of 100 patients using Optic (PO) and Ultrasonic (PU) pachymeters. Measurements were made in the area of the central cornea (ECC) respecting the 3.0 mm territory, in patients with normal corneas of hypermetropic, emetropic and myopic eyes. Patients with ocular diseases, ocular surgeries, and contact lens wearers, were excluded. A statistical analysis was performed using a Paired Student's t test to compare measurements between instruments at the 5 percent level of significance. RESULTS: The mean thickness of the ECC measured by the PO was 603.8±32.6µm and by the PU, 568.2±40.5µm. The difference between the two instruments was 35.7±26.4µm. Applying the t test with p = <5 percent, the difference was significant. We had no statistical difference in ECC between hypermetropic, emetropic and myopic eyes using the PU. CONCLUSION: The measurement of ECC is an over-estimate using the PO as compared with the PU.