Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
The Journal of Korean Academy of Prosthodontics ; : 189-194, 2019.
Article in Korean | WPRIM | ID: wpr-742098

ABSTRACT

It is necessary to set the correct occlusal plane and to distribute the occlusal force uniformly considering the state of the opposing dentition during the prosthetic of the single edentulous patient with severe alveolar bone resorption. Implant supported overdenture is superior to complete denture in terms of maintenance and stability, and limited implants are used in fully edentulous patients with high alveolar bone resorption. Telescopic attachments using a newly introduced material based on poly-aryl-ether-ketone (PAEK) have the advantages of typical telescopic copping, excellent abrasion resistance, and are lighter and more economical than conventional implant overdentures. In this case, we restored maxillary arch with a implant retained overdenture using the telescopic attachment made of Pekkton and the mandible was restored with fixed implant prosthesis. Through these procedures esthetic aspects and functional outcomes were satisfactorily achieved.


Subject(s)
Humans , Bite Force , Bone Resorption , Dental Occlusion , Dentition , Denture, Complete , Denture, Overlay , Mandible , Maxilla , Prostheses and Implants
2.
The Journal of Korean Academy of Prosthodontics ; : 308-316, 2018.
Article in Korean | WPRIM | ID: wpr-717298

ABSTRACT

Telescopic denture has advantages such as transfer the occlusal force to the long axis of the abutment, easiness of oral hygiene management, increase of retention and stability, splint effect due to secondary fixation between abutments and have been reported a higher success rates than conventional removable partial denture (RPD). However, there are disadvantages such as complex laboratory procedures, long treatment periods and high costs, and high incidence of complications. This clinical report describes two cases, a 4-point supported telescopic denture using telescopic crown and a 2-point supported telescopic denture using conical crown with functionally satisfactory results. Frequent complications of telescopic denture, which are reported in various literature were reviewed. Clinical and laboratory procedures were performed in consideration of complications that reported.


Subject(s)
Bite Force , Crowns , Denture, Partial, Removable , Dentures , Incidence , Oral Hygiene , Rehabilitation , Splints
3.
The Journal of Korean Academy of Prosthodontics ; : 46-50, 2015.
Article in Korean | WPRIM | ID: wpr-171202

ABSTRACT

Restoration of a patient with thin and low residual ridges using a removable partial denture cannot provide proper anterioposterior stability and support, so it results in patient discomfort and severe occlusal force. Also, when a small number of residual teeth are far apart from one another, it is difficult to splint. When these teeth are not splinted, they become solitary abutments, which is not a wise treatment decision. In this case, telescopic system reduces severe lateral load on abutments resulting from a clasp denture and it provides stable and definite retention and solidity. In this case report, a patient exhibited full edentulism in maxilla, and a small number of residual teeth in mandible, which were restored with a complete denture and a telescopic denture respectively. In treatment planning, it was concluded that a patient was restored with a telescopic denture since it was highly probable that a clasp denture would create discomfort and difficulty due to a small number of residual teeth located far apart and residual ridges without proper support.


Subject(s)
Humans , Bite Force , Denture, Complete , Denture, Partial, Removable , Dentures , Mandible , Maxilla , Splints , Tooth
4.
Journal of Shanghai Jiaotong University(Medical Science) ; (12): 1288-1290, 2009.
Article in Chinese | WPRIM | ID: wpr-405532

ABSTRACT

Objective To establish three dimensional finite element model libraries of telescopic dentures and removable partial dentures by means of model libraries, and compare the characteristics of stress distribution among three prostheses. Methods Normal model libraries were imported and edited, and models of bilateral free-ended cases were established. Based on the model libraries of fixed partial dentures and removable partial dentures, the finite element models of telescopic dentures and removable partial dentures with medial or distal occlusal rest were established using softwares such as DELL Precision Graphics Workstation, UG 5.0, HyperMesh 7.0 and Abaqus 6.5, then finite element stress analysis was performed. Results The stress distribution on abutment root, parodontium, alveolar mucosa and alveolar bone was uniform. The maximum value of stress on the abutment root (6.205 Mpa) was much less than those of two removable partial dentures (18.41 Mpa and 34.49 Mpa). Conclusion For bilateral free-ended cases, the telescopic denture design is uniform in stress distribution with less stress on abutment root, which is healthy to the abutment root and surrounding tissues.

SELECTION OF CITATIONS
SEARCH DETAIL