Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Instrumentation ; (6): 26-31, 2021.
Article in Chinese | WPRIM | ID: wpr-880417

ABSTRACT

In order to obtain the three-dimensional pulse information and blood pressure waveform needed in the study, a radial artery simulation platform with programmable controlled injection pump as the core was constructed by using the circulation theory of human cardiovascular system and pulse wave formation mechanism. Gaussian function model was selected to synthesize multi-type pulse wave to program and drive the platform. The three-dimensional pulse information and blood pressure waveform of the simulated radial artery were collected by binocular visual pulse detection system and pressure transmitter respectively, and the platform stability and repeatability were tested by Pearson correlation. The experimental results show that the radial artery simulation platform is stable, reliable and repeatable, and can generate multiple types of three-dimensional pulse information and blood pressure waveform at the simulated radial artery. The platform is simple in structure, low in cost, and produces many types of pulsating flow. It provides an experimental research platform for revealing the relationship between the three-dimensional pulse information of radial artery and the change of pressure inside the vessel, as well as the prediction of blood pressure waveform from the three-dimensional pulse information.


Subject(s)
Humans , Blood Pressure , Computer Simulation , Heart Rate , Radial Artery , Vital Signs
2.
International Journal of Biomedical Engineering ; (6): 212-214,219, 2010.
Article in Chinese | WPRIM | ID: wpr-595697

ABSTRACT

Objective To develop a new,three dimensional dynamic system for pulse detection.Methods According to bionics,a multi-information sensing mode with a soft surface is designed on the basis of traditional Chinese medical diagnosis in pulse.This mode imitates the touching sense of human finger and with the application of modern computer information processing technique,the pulse information is extracted in the way that is as close as possible to the traditional Chinese medicine pulse diagnosis.Results With the application of new sensor,pulse signal is detected and the effectiveness of the inovative three-dimension data transimition mode is validated since the pulse signal is three-dimensionally re-displayed on the computer screen.Conclusion The method introduced in this paper is proved feasible for detecting pulse information.Expected results are obtained and the method provides a new way and new feature reference for research and teaching in objectifying the diagnosis of traditional Chinese medical sciences.

SELECTION OF CITATIONS
SEARCH DETAIL