Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 427-430, 2014.
Article in Chinese | WPRIM | ID: wpr-451753

ABSTRACT

Objective To test the accuracy of a three-dimensional dose verification system CompassR,which reconstructing dose distribution based on measurements and independent dose calculation,and to evaluate the feasibility of its application in clinical intensity-modulated radiotherapy (IMRT) quality assure.Methods A set of square-wave chart patterns of 2 cm,1 cm and 0.5 cm gaps was designed and 11 completed IMRT lung plans were selected for the test.EDR2 film and the ionization chamber were used for test and verifying of plane dose distribution and some special points dose of CompassR.The IMRT phantom plans were verified by CompassR with three-dimension based on anatomical information.Parameters including the volume γ pass rate and the average dose deviation were tested using dose volume histograms.Results In square-wave chart patterns test,the dose distribution reconstructed and calculated by CompassR coincided with the measurement using film.The γ pass rates (3%/3 mm,2%/2 mm) exceeded 90%.When the width of field is 0.5 cm,the γ pass rate was a little lower on account of the penumbra zone.Compared to the dose distribution profile which was measured by film,the maximum deviations of the dose distribution profile which was reconstructed and calculated by CompassR were 3.21% and 2.70%.The absolute dose deviation of specific point in the IMRT plans was less than 3%,the maximum deviation occurred in the lung.Compared to film,the averageγpass rates on the isocenter plain in IMRT plan were (94.65 + 1.93)% (3%/3 mm) which was reconstructed by CompassR.In three-dimensional dose verification,the volume γ pass rates of targets and risk organs were not less than 90%,and the deviation of average dose was less than 1%.Conclusions Accuracy of the tested system satisfies the demand of IMRT dose verification.CompassR could provide information of volumetric dosimetry and anatomical location of dose error,which is benefit for evaluating the clinical value of verification result.

2.
Chinese Journal of Radiation Oncology ; (6): 271-275, 2012.
Article in Chinese | WPRIM | ID: wpr-425894

ABSTRACT

ObjectiveTo test a three-dimensional dose verification system,which reconstructing dose to anatomy based on modeling and online measurements ( RDBMOM ),and to evaluate the accuracy and feasibility of its application in clinical intensity-modulated radiotherapy (IMRT) quality assurance.Methods Phantom plans of regular and irregular fields were selected for the testing.All test plans were implemented and the dose distributions were measured using the thimble ion-chamber and two-dimensional ion-chamber array,the accuracy of RDBMOM were then evaluated by comparing the corresponding results.Two practical treated nasopharyngeal carcinoma IMRT plans were verified with RDBMOM and the clinic significancy were valued.ResultsCompared with measurements of the thimble ion-chamber,deviations of RDBMOM were within 1% in all tested cases except small field of 3 cm ×3 cm.The largest deviation of reconstructed dose in IMRT cases was 2.12%.The dose profile reconstructed by RDBMOM coincided with the measurement using two-dimensional ion-chamber array.The γ rates (3%/3 mm) were 94.56% - 100%.The RDBMOM verification of IMRT cases shown that the γ rate > 99% in total and > 98% in planning target volume,deviation in D95 <0.4%,but the largest deviations in mean dose of the parotids and lens were 2.97% and 59.58% respectively.ConclusionsAccuracy of the tested system satisfies the demand of IMRT dose verification.RDBMOM is able to provide information of volumetric dosimctry and anatomical location of dose error,which is benefit for evaluating the clinical value of verification results.

SELECTION OF CITATIONS
SEARCH DETAIL