Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 184
Filter
1.
Acta Medica Philippina ; : 57-63, 2024.
Article in English | WPRIM | ID: wpr-1006404

ABSTRACT

Introduction@#Tibial plateau fractures are due to high energy trauma brought about by axial compression forces and associated varus or valgus component. @*Objective@#Patients diagnosed with tibial plateau fractures from January to December 2018 treated with internal vs. external fixation will be described according to their Schatzker classification. The study further aims to compare the functional outcomes between the two groups in terms of surgery done. @*Methods@#A chart review determined the distribution of demographics. The Modified Rasmussen Score (MRS) was used to determine the clinical and radiographic parameters after taking a new knee radiograph and assessment from the rehabilitation department. The MRS determined the functional outcomes of the said patients. Ethical considerations and proper informed consent were upheld after being reviewed by the hospital’s research committee. @*Results@#Out of 48 patients, 35 underwent internal fixation via open reduction using plates and/or screws, while 13 underwent external fixation using hybrid external fixator. The demographic profile showed mostly males between ages 20 to 49 years old. Most cases were due to vehicular accidents affecting the left lower extremity. In terms of Schatzker classification, the most common was type VI. The computed mean MRS of the internal fixation group was 30.43 while the external fixation group was 30.00, generally showing no significant difference. @*Conclusion@#Surgical intervention of tibial plateau fractures aims for anatomic reduction using internal or external fixation. There was no significant difference on the functional outcome of the two groups despite classifying the respondents according to Schatzker type, hence we can conclude that external fixation be chosen as the treatment of choice for tibial plateau fractures when properly indicated.

2.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 113-118, 2024.
Article in Chinese | WPRIM | ID: wpr-1009117

ABSTRACT

OBJECTIVE@#To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.@*METHODS@#The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.@*RESULTS@#Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.@*CONCLUSION@#Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.


Subject(s)
Humans , Biomechanical Phenomena , Bone Plates , Fracture Fixation, Internal , Fracture Fixation, Intramedullary , Tibial Fractures/surgery , Tibial Plateau Fractures
3.
Rev. venez. cir. ortop. traumatol ; 55(1): 20-28, jun. 2023. graf, tab, ilus
Article in Spanish | LILACS, LIVECS | ID: biblio-1512025

ABSTRACT

Las fracturas de meseta tibial compleja se asocian a traumatismo de alta energía, principalmente en accidentes de motocicleta, siendo un desafío para el cirujano ortopedista. En la década de 1970, Schatzker propuso una clasificación radiológica para las fracturas de la meseta tibial, que destacaba la morfología de los seis tipos principales. Las imágenes de tomografía computarizada y tridimensional, han cambiado la comprensión y el tratamiento de las fracturas de la meseta tibial. Recientemente, esa clasificación original se complementó con una más amplia; puesto que, se introdujo el fragmento en cuña dividida y la continuidad de la columna posterior como determinantes de la estabilidad articular y el papel fundamental que desempeña en el tratamiento de las fracturas de la meseta tibial, con ellos también la importancia de abordajes quirúrgicos que permitan la visualización posterior para una adecuada reducción. El estudio documenta las técnicas de fijación interna y abordajes posteriores realizadas en el IAHULA, valorando los resultados clínicos en cuanto a dolor y satisfacción del paciente, como consolidación, pseudoartrosis o falla en la técnica de osteosíntesis realizada. El resultado a partir de las escalas de evaluación de la AO y KOOS, arrojaron que, con un efecto excelentes se agrupa un 28,6% y bueno a un 42,9%, indicando la importancia de la fijación de la columna posterior, para prevenir artrosis postraumática temprana e inestabilidad articular(AU)


A complex fracture of the posterior tibial plateau are related to high energy traumatisms, mainly during motorcycle accidents, becoming a challenge to the ortopedic surgen. During the seventies, Stchatzker proposed a radiologic classification for the tibial plateau fractures that pointed the morphology of six main types. The computarized and tridimensional tomographic images have changed the comprehension and treatment of these fractures. Recently, the original classification was complemented with a more broaded approach due to the introduction of the fragment in divided crib and the continuity of the posterior column as factors determining the articular stability and the fundamental roll played in the treatment of fractures of the tibial plateau, as well as the important roll of surgical approaches that allow the posterior visualization for a correct reduction. This research documents the technics of internal fixation and posterior approach developed in the IAHULA, evaluating the clinic results about patients' pain level and comfort, as well as the radiologic findings of consolidation, pseudoarthrosis, or fail in the technic of osteosynthesis developed. The results from a point of view of the evaluation scales of the AO and KOOS, show 28.6% with excellent outcomes, and 42.9% with good outcomes, indicating the importance of the fixation of the posterior column to prevent early start of posttraumatic arthrosis and articular instability(AU)


Subject(s)
Humans , Male , Female , Adolescent , Adult , Data Collection , Fracture Fixation, Internal , Land Transport Accidents , Tibial Plateau Fractures
4.
Kinesiologia ; 42(2): 127-131, 20230615.
Article in Spanish, English | LILACS-Express | LILACS | ID: biblio-1552472

ABSTRACT

Objetivo. Analizar el rendimiento biomecánico de las placas de tibia proximal utilizadas en fracturas de platillos tibiales evaluado a través de modelos de elementos finitos. Métodos. Se realizará una búsqueda exhaustiva en PubMed/Medline, Embase, Lilacs, Web of Science y Google Scholar. No se utilizará ninguna restricción de idioma o estado de publicación. Dos revisores examinarán de forma independiente los posibles artículos elegibles, de acuerdo con los criterios de selección predefinidos. Se incluirán los estudios que evalúen el rendimiento de los platillos tibiales proximales utilizados en las fracturas del platillo tibial evaluadas mediante el análisis de elementos finitos. La extracción de datos sobre las características del estudio, los métodos, los resultados y la evaluación del riesgo de sesgo se realizará mediante un formulario estandarizado. Considerando el diseño de estudio no se requiere evaluación por comité de ética. Los resultados de esta revisión se difundirán a través de la publicación en revistas revisadas por pares, redes sociales y congresos de la especialidad. Se espera que los resultados de esta revisión permitan optimizar los resultados del manejo quirúrgico de las fracturas de platillos tibiales. Número de registro PROSPERO: CRD42023396015.


Objetive. To analyze the biomechanical performance of proximal tibial plates used in tibial plate fractures evaluated through finite element modeling. Methods. A comprehensive search will be conducted in PubMed/Medline, Embase, Lilacs, Web of Science, and Google Scholar. No language or publication status restrictions will be used. Two reviewers will independently review potential eligible articles according to predefined selection criteria. Studies evaluating the performance of proximal tibial splints used in tibial splint fractures assessed by finite element analysis will be included. Data extraction on study characteristics, methods, results, and risk of bias assessment will be performed using a standardized form. Considering the study design, evaluation by an ethics committee is not required. The results of this review will be disseminated through publication in peer-reviewed journals, social networks and specialty congresses. It is expected that the results of this review will allow optimizing the results of the surgical management of tibial plate fractures. PROSPERO registration number: CRD42023396015.

5.
Chinese Journal of Medical Instrumentation ; (6): 502-506, 2023.
Article in Chinese | WPRIM | ID: wpr-1010228

ABSTRACT

OBJECTIVE@#The purpose of this study is to explore the biomechanical characteristics of the tibia after unicompartmental knee arthroplasty with different distributions of two-pin holes, and to optimize the two-pin holes scheme to reduce the risk of tibial fractures after unicompartmental knee arthroplasty.@*METHODS@#Lower limbs model is segmented and reconstructed from computed tomography images. Four combinations of two pin holes created for tibial cutting guide placement are simulated with finite element analysis.@*RESULTS@#In the third mode, the positioning hole at the proximal medial edge of the tibial plateau has the highest stress value, and the position of the positioning hole near the medial edge of the proximal tibial plateau appears stress concentration.@*CONCLUSIONS@#The present study revealed that placing tibial cutting guide holding pins centrally would lower the risks of periprosthetic fracture of the medial tibial plateau.


Subject(s)
Arthroplasty, Replacement, Knee , Tibia/surgery , Lower Extremity , Finite Element Analysis , Tomography, X-Ray Computed
6.
China Journal of Orthopaedics and Traumatology ; (12): 570-573, 2023.
Article in Chinese | WPRIM | ID: wpr-981734

ABSTRACT

OBJECTIVE@#To develop a reduction device for the arthroscopy-assisted treatment of tibial plateau fracture and explore its clinical efficacy.@*METHODS@#From May 2018 to September 2019, 21 patients with tibial plateau fracture were treated, including 17 males and 4 females. Their ages ranged from 18 to 55 years old with an average of (38.6±8.7) years old. There were 5 cases of Schatzker typeⅡand 16 cases of Schatzker type Ⅲ. The self-designed reductor combined with arthroscope was used for auxiliary reduction and fixation(minimally invasive percutaneous plate osteosynthesis). The efficacy was analyzed by observing the operation time, blood loss, fracture healing time and knee function(HSS and IKDC scoring criteria).@*RESULTS@#All the 21 patients were followed up for 8 to 24 with an average of(14.0±3.1) months. The operative time ranged from 70 to 95 min with an average of(81.7±7.6)min, incision length ranged from 4 to 7 cm with an average of(5.3±0.9) cm, intraoperative blood loss ranged from 20 to 50 ml with an average of(35.3±5.2) ml, postoperative weight-bearing time ranged from 30 to 50 d with an average of(35.1±9.2) d, fracture healing time ranged from 65 to 90 d with an average of(75.0±4.4) d, and complications were 0 cases, respectively. The fracture was well healed and no screw plate fracture was observed. The knee function scores of HSS and IKDC 18 months after operation were significantly higher than those before operation(P<0.05).@*CONCLUSION@#The custom-made reduction tool for the arthroscopic management of tibial plateau fracture is reasonable in design and simple in operation. The specific reduction tool could effectively reduce the fracture, and shorten the fixation time with minimally invasive procedure.


Subject(s)
Male , Female , Humans , Adolescent , Young Adult , Adult , Middle Aged , Tibial Plateau Fractures , Tibial Fractures/surgery , Fracture Fixation, Internal/methods , Treatment Outcome , Bone Plates , Retrospective Studies
7.
China Journal of Orthopaedics and Traumatology ; (12): 308-312, 2023.
Article in Chinese | WPRIM | ID: wpr-981688

ABSTRACT

OBJECTIVE@#To explore treatment strategy for complex Schatzker Ⅳ tibial plateau fracture.@*METHODS@#Forty-one patients with complex Schatzker type Ⅳ tibial plateau fractures were treated from January 2016 to January 2021, including 28 males and 13 females, aged from 19 to 65 years old with an average of (35.3±19.8) years old. Individualized treatment plan was developed according to preoperative imaging characteristics, medial surgical approach was mainly combined with other auxiliary incisions. Posteromedial inverted L approach was used in 18 patients, posteromedial approach and anterolateral extended approach in 19 patients, and posteromedial approach with anterolateral and lateral condylar osteotomy in 4 patients. Articular surface and facture healing were observed, range of knee joint motion was measured at 12 months after opertaion, and function of knee joint was evaluated by Lysholm scoring system.@*RESULTS@#Forty-one patients were followed up for 12 to 26 months with an average of (13.3±6.8) months. Twenty-nine patients and 10 patients were obtained complete fracture healing at 6 and 12 months after operation respectively, and fracture healing time was 4 to 13 months with an average of (5.0±3.7) months. Two patients occurred posterior medial internal fixation failure and varus deformity of knee joint, and the fracture healed and varus deformity was corrected after the second operation. Range of knee joint motion was (118±29) °, and Lysholm score was(83.0±16.0) points.@*CONCLUSION@#Individualized treatment should be reasonably selected for complex Schatzker Ⅳ tibial plateau fractures, the characteristics of lateral plateau fractures are an important reference for selecting surgical approaches, the effective fixation of posteromedial bone blocks should be pay full attention, and the overall treatment results are satisfied.


Subject(s)
Male , Female , Humans , Young Adult , Adult , Middle Aged , Aged , Adolescent , Tibial Plateau Fractures , Bone Plates , Tibial Fractures/surgery , Treatment Outcome , Knee Joint/surgery , Fracture Fixation, Internal/methods , Retrospective Studies
8.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 410-416, 2023.
Article in Chinese | WPRIM | ID: wpr-981607

ABSTRACT

OBJECTIVE@#To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.@*METHODS@#A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.@*RESULTS@#All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).@*CONCLUSION@#For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.


Subject(s)
Male , Female , Humans , Adult , Retrospective Studies , Blood Loss, Surgical , Tibial Plateau Fractures , Treatment Outcome , Bone Plates , Tibial Fractures/surgery , Knee Joint , Fracture Fixation, Internal , Osteotomy , Weight-Bearing
9.
Rev. med. Urug ; 39(1): e401, 2023.
Article in Spanish | LILACS, BNUY | ID: biblio-1431903

ABSTRACT

Objetivo: comparar si existe diferencia en resultados clínicos, radiológicos y funcionales con el uso de diferentes tipos de injertos óseos o sustitutos sintéticos, así como tiempo quirúrgico y consolidación para el tratamiento de fracturas de platillo tibial con hundimiento articular en pacientes mayores de 18 años. Material y método: se realizó una búsqueda sistematizada en bases de datos de literatura médica, PubMed, Lilacs, Scielo, Cochrane y portal Timbó. Se utilizaron términos "tibial plateau fracture", "bone grafting", "bone substitutes". Se incluyeron estudios comparativos en seres humanos, pacientes mayores de 18 años, fracturas de platillo tibial que asociaron hundimiento articular, en los cuales se realizó aporte de injerto óseo o material sintético. Artículos en español, inglés, portugués. Publicaciones enero 1980 y diciembre 2021. Se obtuvieron 10 artículos. Resultados: los tipos de injertos y sustitutos óseos encontrados fueron 10. Las muestras en sumatoria total 524 pacientes. La edad promedio fue 49 años. El promedio de seguimiento fue de 12 meses. Se dividieron los estudios en tres grupos: comparación entre injerto autólogo (IOA) e injerto alogénico, IOA con sustitutos sintéticos, y los que comparan sustitutos sintéticos entre sí. El aloinjerto y los sustitutos sintéticos demostraron no ser inferiores en resultados clínicos, funcionales e imagenológicos, mejorando los tiempos intraoperatorios y disminuyendo complicaciones en el sitio donante con respecto al IOA. Conclusiones: el IOA continúa siendo el gold standard a pesar de sus posibles complicaciones vinculadas al sitio donante. El aloinjerto y los sustitutos sintéticos representan una opción válida para tratar estas lesiones.


Objective: to find out whether there are clinical, radiological and functional differences when using different types of bone grafts or synthetic substitutes, as well as surgical times and consolidation to treat depressed tibial-plateau fractures in patients older than 18 years old. Method: a systematized search was conducted in medical literature, PubMed, Lilacs, Scielo, Cochrane and Timbó portal databases using the following terms: "tibial plateau fracture", "bone grafting", "bone substitutes". The study included comparative studies in human patients older than 18 years old with depressed tibial-plateau fractures who were treated with bone grafts or synthetic materials. Publications in Spanish, English and Portuguese, between January, 1980 and December, 2021 were included in the search, what resulted in 10 articles found. Results: there were 10 kinds of bone grafts and bone substitutes found. Samples added up to 524 patients. Average age was 49 years old. Average follow up was 12 months. Studies were divided into 3 groups: comparison between autologous bone grafts and allogenic bone grafts, comparison between autologous grafts and synthetic substitutes and studies comparing synthetic substitutes with one another. Allogenic grafts and synthetic grafts proved at least equivalent in terms of clinical, functional and imaging studies results, improving intraoperative times and reducing complications in donor site when compared to autologous grafts. Conclusions: autologous grafts continue to be the gold standard despite possible complications associated to the donor site, and allogenic grafts and synthetic substitutes constitute a valid option to treat these lesions.


Objetivo: comparar os resultados clínicos, radiológicos e funcionais com o uso de diferentes tipos de enxertos ósseos ou substitutos sintéticos, bem como tempo cirúrgico e consolidação para o tratamento de fraturas do platô tibial com colapso articular em pacientes com mais de 18 anos. Material e método: foi realizada busca sistemática nas bases de dados da literatura médica, PubMed, Lilacs, SciELO, Cochrane e portal Timbó. Utilizaram-se os termos "tibial plateau fracture", "bone grafting", "bone substitutes". Foram incluídos estudos comparativos incluindo seres humanos maiores de 18 anos e fraturas do platô tibial associadas a colapso articular, nas quais foi realizado enxerto ósseo ou sintético, publicados entre janeiro de 1980 e dezembro de 2021 em espanhol, inglês e português. Foram obtidos 10 artigos. Resultados: foram identificados 10 tipos de enxertos e substitutos ósseos. 524 pacientes com idade média de 49 anos foram estudados. O seguimento médio foi de 12 meses. Os estudos foram divididos em 3 grupos: comparação entre enxerto autólogo (IOA) e enxerto alogênico, IOA com substitutos sintéticos e substitutos sintéticos entre si. O aloenxerto e os substitutos sintéticos mostraram-se não inferiores nos resultados clínicos, funcionais e de imagem, melhorando os tempos intraoperatórios e reduzindo as complicações da área doadora em relação à IOA. Conclusões: o IOA continua a ser o padrão ouro apesar de suas possíveis complicações relacionadas ao local doador; tanto o aloenxerto como os substitutos sintéticos representam uma opção válida para tratar essas lesões.


Subject(s)
Tibial Fractures/surgery , Bone Substitutes , Tibial Plateau Fractures/surgery
10.
Chinese Journal of Traumatology ; (6): 334-338, 2023.
Article in English | WPRIM | ID: wpr-1009486

ABSTRACT

PURPOSE@#Electric scooters (e-scooters) have become an increasingly popular mode of public transportation in recent years. As the incidence of related injuries rises, it is important to understand specific fracture patterns unique to e-scooters and electric bikes (e-bikes) to help guide management. The purpose of this study was to review the prevalence and describe specific fracture patterns of e-scooter and e-bike related injuries at the busiest level 1 trauma center in the borough of Manhattan.@*METHODS@#Chart review to determine mechanism of injury was performed on all patients for whom an orthopedic consult was requested from 1/1/2021 to 12/31/2021. All patients whose injuries were sustained due to an e-scooter or e-bike were further reviewed for demographics, injury characteristics including fracture pattern, and definitive injury management. Any patients who had an orthopedic consult placed for a reason other than an acute injury were excluded. Descriptive statistics are reported as frequency (percentage) for categorical variables and means for continuous variables.@*RESULTS@#Of the 1815 orthopedic consults requested, 1357 (74.8%) were for acute injury management. Of those with acute injuries, 119 (8.8%) sustained 136 e-scooter or e-bike related injuries. There were 92 (77.3%) males at an average age of (33.8 ± 15.7) years. Approximately one-fifth of all patients presented in June 2021 (26, 21.8%). There was a 9.2% rate of open fractures. The 136 injuries were evenly split between the upper and lower extremities, with 57 (47.9%) upper extremity, 57 (47.9%) lower extremity injuries, and 5 (4.2%) concomitant upper and lower extremity injuries. The most common fracture patterns were ankle fractures (16, 11.7%), followed by tibial shaft (14, 10.2%), tibial plateau (13, 9.5%), and radial head fractures (11, 8.0%). There was a 33.3% incidence of associated posterior malleolar fractures in the spiral tibial shaft fractures, 31.0% of posterior malleolar involvement and 18.8% of isolated vertical medial malleolar fractures in the ankle fractures, and 61.5% of posterior comminution in the tibial plateau fractures.@*CONCLUSION@#E-scooter and e-bike related injuries have a high incidence of tibial shaft fractures, ankle fractures, tibial plateau fractures, and radial head fractures. There should be a high index of suspicion for posterior and medial involvement in lower extremity fractures sustained due to e-scooter or e-bikes. Identifying specific fracture patterns seen in e-scooter and e-bike related mechanisms will help guide management of these injuries.


Subject(s)
Male , Humans , Adolescent , Young Adult , Adult , Middle Aged , Female , Ankle Fractures , Trauma Centers , Incidence , Radial Head and Neck Fractures , Tibial Plateau Fractures , Retrospective Studies , Tibial Fractures/complications , Radius Fractures
11.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1459-1464, 2023.
Article in Chinese | WPRIM | ID: wpr-1009083

ABSTRACT

OBJECTIVE@#To explore the reduction and support effect of the subchondral screw compression technique for residual or secondary collapse of the lateral tibial plateau during operation.@*METHODS@#Between January 2020 and June 2021, 11 patients with residual or secondary collapse of the lateral tibial plateau during operation were treated with the subchondral screw compression technique. There were 6 males and 5 females, aged 52.3 years old (range, 27-64 years). The fractures were caused by traffic accident in 10 cases and falling from height in 1 case and located at the left knee in 6 cases and the right knee in 5 cases. According to Schatzker classification, there were 5 cases of type Ⅱ fractures, 4 cases of type Ⅲ fractures, and 2 cases of type Ⅴfractures. According to the three columns classification, there were 5 cases of lateral column, 4 cases of lateral column and posterior column, and 2 cases of three columns. The time from injury to operation was 4.5 days (range, 3-7 days). During the follow-up, X-ray films were obtained and the Rasmussen standard was used to evaluate the quality of fracture reduction, meanwhile fracture healing was observed. The medial proximal tibial angle (mPTA), posterior tibial slope angle (pTSA), and articular surface collapse were measured at immediate and 12 months after operation. The knee joint range of motion was evaluated at last follow-up, and the knee joint function was evaluated using the Hospital for Special Surgery (HSS) score.@*RESULTS@#All operations were successfully completed, with a mean operation time of 71.4 minutes (range, 55-120 minutes), and a mean hospital stay of 8.0 days (range, 5-13 days). The incisions all healed by first intention, without complications such as infection, flap necrosis, or vascular and nerve injury. All patients were followed up 16.5 months on average (range, 12-24 months). X-ray films showed that the fracture reduction score was 14-18 (mean, 16.7) according to Rasmussen score criteria; and 5 cases were rated as excellent and 6 as good. All fractures healed clinically with a mean clinical healing time of 14.9 weeks (range, 12-16 weeks), and there was no complications such as plate or screw loosening. At 12 months after operation, the mPTA and pTSA were (87.5±1.7)° and (6.2±3.1)°, respectively; there was no significant difference when compared to the values at immediate after operation [(87.6±1.8)° and (6.5±3.1)°] ( P>0.05). The articular surface of the tibial plateaus was effectively supported, and it collapsed again by 0-1.0 mm at 12 months, with an average of 0.4 mm. At last follow-up, the knee joint range of motion was 115°-135° (mean, 126.8°) and the HSS score for knee joint function was 87-98 (mean, 93.9). Five patients underwent secondary operation to remove the internal fixator at 12-18 months after operation.@*CONCLUSION@#The subchondral screw compression technique is helpful for the reduction of residual or secondary collapse of the lateral tibial plateau during operation, and can provide good support for osteochondral blocks.


Subject(s)
Male , Female , Humans , Middle Aged , Tibial Fractures/complications , Fracture Fixation, Internal/methods , Treatment Outcome , Knee Joint/surgery , Bone Screws , Retrospective Studies
12.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1055-1061, 2023.
Article in Chinese | WPRIM | ID: wpr-1009023

ABSTRACT

OBJECTIVE@#To investigate the efficacy and safety of multiple-dose intravenous tranexamic acid (TXA) for reducing blood loss in complex tibial plateau fractures with open reduction internal fixation by a prospective randomized controlled trial.@*METHODS@#A study was conducted on patients with Schatzker type Ⅳ-Ⅵ tibial plateau fractures admitted between August 2020 and December 2022. Among them, 88 patients met the selection criteria and were included in the study. They were randomly allocated into 3 groups, the control group (28 cases), single-dose TXA group (31 cases), and multiple-dose TXA group (29 cases), using a random number table method. There was no significant difference ( P>0.05) in terms of age, gender, body mass index, the Schatzker type and side of fracture, laboratory examinations [hemoglobin (Hb), activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fib), international normalized ratio (INR), D-dimer, and interleukin 6 (IL-6)], and preoperative blood volume. The control group received intravenous infusion of 100 mL saline at 15 minutes before operation and 3, 6, and 24 hours after the first administration. The single-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at 15 minutes before operation, followed by an equal amount of saline at each time point after the first administration. The multiple-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at each time point. The relevant indicators were recorded and compared between groups to evaluate the effectiveness and safety of TXA, including hospital stays, operation time, occurrence of infection; the occurrence of lower extremity deep vein thrombosis, intermuscular vein thrombosis, and pulmonary embolism at 1 week after operation; the lowest postoperative Hb value and Hb reduction rate, the difference (change value) between pre- and post-operative APTT, PT, Fib, and INR; D-dimer and IL-6 at 24 and 72 hours after operation; total blood loss, intraoperative blood loss, hidden blood loss, drainage flow during 48 hours after operation, and postoperative blood transfusion.@*RESULTS@#① TXA efficacy evaluation: the lowest Hb value in the control group was significantly lower than that in the other two groups ( P<0.05), and there was no significant difference between the single- and multiple-dose TXA groups ( P>0.05). The Hb reduction rate, total blood loss, intraoperative blood loss, drainage flow during 48 hours after operation, and hidden blood loss showed a gradual decrease trend in the control group, single-dose TXA group, and multiple-dose TXA group. And differences were significant ( P<0.05) in the Hb reduction rate and drainage flow during 48 hours after operation between groups, and the total blood loss and hidden blood loss between control group and other two groups. ② TXA safety evaluation: no lower extremity deep vein thrombosis or pulmonary embolism occurred in the three groups after operation, but 3, 4, and 2 cases of intermuscular vein thrombosis occurred in the control group, single-dose TXA group, and multiple-dose TXA group, respectively, and the differences in the incidences between groups were not significant ( P>0.05). There was no significant difference in the operation time between groups ( P>0.05). But the length of hospital stay was significantly longer in the control group than in the other groups ( P<0.05); there was no significant difference between the single- and multiple-dose TXA groups ( P>0.05). ③ Effect of TXA on blood coagulation and inflammatory response: the incisions of the 3 groups healed by first intention, and no infections occurred. The differences in the changes of APTT, PT, Fib, and INR between groups were not significant ( P>0.05). The D-dimer and IL-6 in the three groups showed a trend of first increasing and then decreasing over time, and there was a significant difference between different time points in the three groups ( P<0.05). At 24 and 72 hours after operation, there was no significant difference in D-dimer between groups ( P>0.05), while there was a significant difference in IL-6 between groups ( P<0.05).@*CONCLUSION@#Multiple intravenous applications of TXA can reduce perioperative blood loss and shorten hospital stays in patients undergoing open reduction and internal fixation of complex tibial plateau fractures, provide additional fibrinolysis control and ameliorate postoperative inflammatory response.


Subject(s)
Humans , Tranexamic Acid/therapeutic use , Blood Loss, Surgical/prevention & control , Interleukin-6 , Prospective Studies , Tibial Plateau Fractures , Tibial Fractures/surgery , Thrombosis
13.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 978-981, 2023.
Article in Chinese | WPRIM | ID: wpr-1009011

ABSTRACT

OBJECTIVE@#To investigate the relationship between the vertical distance from semitendinosus insertion to tibial plateau (S-T) and the physical characteristics of patients, in order to provide reference for incision design to expose the semitendinosus insertion.@*METHODS@#The patients with ligament injury who underwent primary anterior cruciate ligament reconstruction between January 2022 and December 2022 were selected as the research subjects. The patients' baseline data were collected, including age, gender, height, and body mass. During reconstruction operation, the S-T was measured. Considering the S-T as the dependent variable and baseline data as the independent variable, multiple linear regression analysis was used to establish a regression equation to determine the possible influencing factors of semitendinosus insertion location.@*RESULTS@#According to the selection standard, a total of 214 patients were enrolled, including 156 males and 58 females, aged (27±9) years (14-49 years), with a height of (174.7±6.8) cm (range, 160-196 cm) and a body mass of (73.43±12.35) kg (range, 53-105 kg). The S-T was (56.36±3.61) mm (range, 47-67 mm). The multiple linear regression analysis results showed that the height was positively correlated with S-T (β=0.407, SE=0.055, t=7.543, P<0.001); the regression equation was S-T=-14.701+0.407×height, R2=0.690.@*CONCLUSION@#There was a linear relationship between the height and semitendinosus insertion. The location of semitendinosus insertion estimated by the formula (S-T=-14.701+0.407×height) is reasonable, which provides a theoretical basis for rapid, accurate, and safe location of semitendinosus insertion and design of surgical incision in clinic.


Subject(s)
Female , Male , Humans , Correlation of Data , Hamstring Muscles , Plastic Surgery Procedures , Anterior Cruciate Ligament Reconstruction , Physical Examination
14.
Multimed (Granma) ; 26(3): e2241, mayo.-jun. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1406106

ABSTRACT

RESUMEN Introducción: la artropatía enteropática representa una manifestación derivada de complicaciones inflamatorias intestinales. Presentación del caso: paciente de 53 años de edad, de piel blanca, femenina, que sufrió caída de sus pies, con trauma en rodilla izquierda que le ocasionó fractura de meseta tibial izquierda. Discusión: los estudios radiológicos fueron positivos y confirman el diagnóstico de la artropatía enteropática y fractura de platillos tibiales, se aplicaron pautas de tratamientos integradores funcionales. Conclusiones: con los tratamientos el paciente reportó efectos beneficiosos, se lograron los objetivos propuestos en la rehabilitación, así como la incorporación de la paciente a la sociedad con un mínimo de discapacidad e independencia.


ABSTRACT Introduction: enteropathic arthropathy represents a manifestation derived from intestinal inflammatory complications. Case presentation: 53-year-old white-skinned female patient who suffered a fall from her feet, with trauma to the left knee that caused a fracture of the left tibial plateau. Discussion: the radiological studies were positive and confirm the diagnosis of enteropathic arthropathy and tibial plateau fractures, functional integrative treatment guidelines were applied. Conclusions: with the treatments the patient reported beneficial effects, the objectives proposed in the rehabilitation were achieved, as well as the incorporation of the patient into society with a minimum of disability and independence.


RESUMO Introdução: a artropatia enteropática representa uma manifestação derivada de complicações inflamatórias intestinais. Apresentação do caso: Paciente do sexo feminino, 53 anos, branca, que sofreu queda dos pés, com trauma no joelho esquerdo que ocasionou fratura do platô tibial esquerdo. Discussão: os estudos radiológicos foram positivos e confirmam o diagnóstico de artropatia enteropática e fraturas do planalto tibial, foram aplicadas diretrizes de tratamento integrativo funcional. Conclusões: com os tratamentos o paciente relatou efeitos benéficos, os objetivos propostos na reabilitação foram alcançados, bem como a incorporação do paciente à sociedade com um mínimo de incapacidade e independência.

15.
Rev. Assoc. Méd. Rio Gd. do Sul ; 66(1): 01022105, 20220101.
Article in Portuguese | LILACS | ID: biblio-1425002

ABSTRACT

O presente trabalho avaliou os aspectos epidemiológicos das fraturas do platô tibial tratados cirurgicamente no Serviço de Ortopedia e Traumatologia do Hospital Santo Antônio, em Blumenau/SC. O trabalho analisou, retrospectivamente, por revisão de prontuários, 62 casos de fratura do planalto tibial tratados entre 2016-2018, nos quesitos idade, gênero, lateralidade, mecanismo lesional, lesões associadas, classificação de Schatzker e complicações. A média de idade foi de 44,8 anos ±14,4; entre os homens foi de 48 anos ±17,3; entre as mulheres de 43,7 anos ±13,3 anos. A incidência foi de 14,2 casos/105 hab/ano; por gênero, em homens 21,1 casos/105 hab/ano em relação à de mulheres, de 7,6 casos/105 hab/ano. O lado mais acometido foi o esquerdo, 57% dos casos, 40% à direita e 3% com bilateralidade. Mecanismos lesionais relatados: acidente de motocicleta 63%; queda de nível 11%; atropelamento 6%; agressão 5%; bicicleta 3%; desportivo 3%; carro 3%; própria altura 3% e quadriciclo 2%. Lesões associadas estiveram presentes em 33,9% da amostra, mais comuns nos membros inferiores, 24%. Optou-se pela classificação de Schatzker, com tipo VI 53%, tipo II 20%, tipo I 12% , tipo III 7%, tipo IV 5%, tipo V 3%. As complicações registradas nos prontuários totalizaram 43,5% da amostra. Perda parcial de amplitude de movimento foi a mais relatada, com 17,7% da amostra. Infecção da ferida operatória apresentou-se em 11,7% da amostra.


This study evaluated the epidemiological aspects of tibial plateau fractures surgically treated in the Hospital Santo Antônio orthopedics and traumatology service in Blumenau, SC, Brazil. The medical records of 62 cases of tibial plateau fracture treated between 2016 and 2018 were retrospectively analyzed regarding age, sex, laterality, mechanism of lesion, associated injuries, Schatzker classification, and complications. The mean age was 44.8 years (SD, 14.4) for the overall sample, 48 years (SD, 17.3) for men, and 43.7 years (SD, 13.3) for women. The incidence was 14.2 cases per 100,000 residents per year for the overall sample, 21.1 cases per 100,000 residents per year for men, and 7.6 cases per 100,000 residents per for women. The left side was more affected (57%) than the right (40%), and 3% were bilateral. The reported mechanisms of injury were: motorcycle accident (63%), fall from a height (11%), being run over by a vehicle (6%), assault (5%), bicycle accident (3%), sports (3%), car accident (3%), fall from standing height (3%) and quadricycle accident (2%). There were associated injuries in 33.9% of the sample, most often in the lower limbs (24%). Fracture types were classified according to the Schatzker system: type VI 53%, type II 20%, type I 12%, type III 7%, type IV 5%, type V 3%. Complications were reported in 43.5% of the sample, with partial loss of range of motion being the most common (17.7%). Surgical wound infection occurred in 11.7% of the sample.


Subject(s)
Tibial Plateau Fractures
16.
Malaysian Orthopaedic Journal ; : 18-27, 2022.
Article in English | WPRIM | ID: wpr-934781

ABSTRACT

@#Introduction: Tibial bicondylar fractures are difficult fractures to treat and are usually associated with complications. Materials and methods: Thirty-five patients with Schatzker type V and VI fractures were managed from June 2016 to July 2018 with Ilizarov technique. The mean age of the patients was 46.5 ± 8.9 years, with 28 male and seven female patients. Sixteen patients had Schatzker type V fracture and the remaining had type VI. The functional outcome was assessed by using Modified functional evaluation system by Karlstrom - Olerud and the radiological outcome by Rasmussen's Radiological Score (RRS). Results: All patients achieved radiological union at a mean duration of 16 weeks for type 5 and 17 weeks for type 6 however, full weight-bearing was allowed at a mean of 18 weeks (14 - 22 weeks). Functional results were excellent in 24 cases, good in 10 and poor in one. Most patients achieved functional range of motion at the knee joint (average flexion 1280 ) except one, who had a flexion of less than 1100 . One patient with a delayed union united after bone marrow injection. Other complications included pin tract infections in 9 cases, axial malalignment of less than 100 in 4 cases and a prominent screw in one. Conclusion: Percutaneous restoration of articular anatomy and a ring external fixation with or without minimal internal fixation is an excellent method of treatment in this group of fractures caused by high energy trauma and with a usual association of severe comminution and a poor soft tissue envelope.

17.
Chinese Journal of Orthopaedic Trauma ; (12): 429-435, 2022.
Article in Chinese | WPRIM | ID: wpr-932350

ABSTRACT

Objective:To compare the clinical effects between cannulated screwing and plating in combination with interlocking intramedullary nailing for the treatment of ipsilateral discontinuous fractures of the tibial shaft and plateau.Methods:A retrospective analysis was performed of the clinical data of 34 patients who had been treated for ipsilateral discontinuous fractures of the tibial shaft and plateau at Department of Orthopedics and Trauma, Honghui Hospital Affiliated to Xi′an Jiaotong University from January 2015 to January 2020. There were 17 males and 17 females, aged from 26 to 60 years (average, of 43.6 years). The left side was affected in 18 cases and the right side in 16. The patients were divided into 2 groups according to their internal fixation methods: a cannulated screw group of 16 cases treated with cannulated screwing and intramedullary nailing and a plate group of 18 cases treated with plating and intramedullary nailing. The 2 groups were compared in terms of operation time, intraoperative blood loss, incision length, tibial plateau collapse, consumables cost, hospital stay, fracture healing time, weight-bearing time, range of knee motion, reduction of tibial plateau fracture by Rasmussen radiology, Lysholm knee function score at the last follow-up and complications.Results:There was no significant difference in the preoperative general data between the 2 groups, showing the 2 groups were comparable ( P>0.05). All the 34 patients were followed up for 12 to 28 months (average, 17.4 months). There was no significant difference either in operation time, hospital stay, tibial plateau healing time, tibial fracture healing time, weight-bearing time or range of knee motion between the 2 groups ( P>0.05). In the cannulated screw group, the intraoperative blood loss [(89.4 ± 14.5) mL] and consumables cost [(2.0 ± 0.2) ten thousand yuan] were significantly less than those in the plate group [(120.8 ± 22.1) mL and (2.6 ± 0.4) ten thousand yuan], the incision length [(4.1 ± 0.8) cm] was significantly shorter than that in the plate group [(7.1 ± 0.9) cm], and the Lysholm knee function score at the last follow-up [(89.8 ± 4.5) points] was significantly lower than that in the plate group [(93.0 ± 4.2 points] (all P<0.05). The difference was statistically significant between the 2 groups in the quality of tibial plateau reduction ( P<0.05). The postoperative tibial plateau collapse in the plate group [0.5 (0, 2) mm] was insignificantly less than that in the cannulated screw group [1.0 (0, 2) mm] ( P>0.05). In the cannulated screw group, one tibial shaft fracture did not achieve union after operation and deep vein thrombosis occurred in 2 cases after operation; in the plate group, 2 cases suffered from delayed wound healing, one from delayed fracture healing, one from deep venous thrombosis of lower extremity, and one from knee discomfort which was relieved after removal of internal fixation. Conclusions:In the treatment of ipsilateral discontinuous fractures of tibial shaft and plateau, both cannulated screwing and plating in combination with interlocking intramedullary nailing can achieve good clinical effects. Although plating in combination with intramedullary nailing lead to more severe trauma and higher costs, it is conducive to improving the reduction quality of the tibial plateau and postoperative functional recovery of the knee joint.

18.
Chinese Journal of Traumatology ; (6): 59-62, 2022.
Article in English | WPRIM | ID: wpr-928470

ABSTRACT

Schatzkter type-I tibial plateau fracture is a split fracture of the lateral tibial plateau in sagittal plane, consequent to valgus impaction caused by low velocity of trauma. However, a deep understanding of the different columns of the tibial plateau and patho-mechanisms of the injury led to the unmasking of atypical fractures around the tibial plateau. We have encountered 2 cases with unusual fracture pattern of the lateral tibial condyle caused by road traffic accidents. The fracture pattern and severity of injury deviate from the original description of Schatzker type 1; in view of dual plane split, there is rotation of the posterolateral column fragment along its sagittal plane plus grade-III medial collateral ligament injury. The patients were initially treated with knee spanning external fixator and after a latency of 5 days, definitive fracture specific fixation was done, combined with repair of grade-III medial collateral ligament injury. At the 6 months follow-up both the patients achieved satisfactory knee functions (knee society score case 1: 100 and case 2: 92) and returned to their jobs. The severity of fracture pattern and displacement as described should prompt for examination of associated ligament injury. Because of timely diagnosis, early and appropriate care promised an excellent function outcome even in such a severe nature of knee injury. To prompt the description of injury pattern we coined the name "dual split and dislocation" of lateral tibial plateau, as a complex injury variant of split fracture of lateral tibial plateau fracture.


Subject(s)
Humans , External Fixators , Fracture Fixation, Internal , Joint Dislocations , Knee Injuries , Tibial Fractures/surgery
19.
An. Facultad Med. (Univ. Repúb. Urug., En línea) ; 8(2): e301, dic. 2021. ilus, tab
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1358052

ABSTRACT

Objetivo: El objetivo del presente estudio es explorar y describir resultados y experiencias en el tratamiento de las fracturas de platillo tibial Schatzker1 I-IV con asistencia artroscópica para obtener reducción como parte de la técnica de fijación interna (ARIF). Metodología: Se realizó una búsqueda sistematizada en diferentes motores de búsqueda como Pubmed y Lilacs. Se buscó con la misma metodología por 2 revisores independientes utilizando términos MESH "Tibial Fracture", "Arthroscopic". Se incluyeron artículos publicados en los últimos 5 años (2014 a Setiembre 2020), que muestren resultados clínicos de los procedimientos, en inglés o español, en humanos y mayores de 18 años. Resultados: Siguiendo los criterios de inclusión se identificaron 114 títulos, y finalmente 9 artículos fueron incluidos en nuestra revisión sistematizada. De los 9 artículos revisados 5 corresponden a series de casos con un nivel de evidencia IV, 3 corresponden a estudios comparativos retrospectivos entre técnicas de reducción abierta y fijación interna (ORIF) y ARIF con nivel de evidencia III y un estudio corresponde a un nivel de evidencia I. Un total de 217 pacientes fueron intervenidos mediante ARIF en nuestra revisión, el tiempo promedio de seguimiento fue de 24.9 meses (12-90 m), en cuanto al tipo de fractura las más frecuentes fueron las fracturas de platillo tibial Schatzker II y III, la lesión asociada más frecuente fue la lesión meniscal seguida de la rotura del ligamento cruzado anterior. En cuanto al porcentaje total de resultados obtenidos independientemente de cada score utilizado, el 98% aproximadamente obtuvo resultados buenos o excelentes. El porcentaje de complicaciones operadas con asistencia artroscópica resultó ser aproximadamente del 6.5%, siendo la complicación más frecuente la trombosis venosa profunda con 6 casos. Conclusiones: De nuestra revisión podemos concluir que la asistencia artroscópica es útil en el tratamiento de las fracturas de platillo tibial Schatzker I-IV, siendo una técnica que provee resultados funcionales satisfactorios, sin incrementar el número de complicaciones y permite tratar lesiones asociadas en el mismo acto.


Objective: The objective of this study is to explore the experience and the results of Schatzker1 I-IV tibial plateau fractures internal fixation technique (ARIF) with arthroscopic assistance Methodology: A systematic review was carried out in different search engines such as Pubmed and Lilacs. The same methodology was applied by two independent reviewers using MESH terms "Tibial Fracture", "Arthroscopic". Articles published in the last 5 years (2014 to September 2020) were included, showing clinical results of the procedures, in English or Spanish, in humans and over 18 years of age. Results: Following the inclusion criteria, 114 titles were identified, and finally 9 articles were included in our systematic review. Of the 9 articles reviewed, 5 were case series (level of evidence IV), 3 retrospective comparative studies between open reduction and internal fixation techniques (ORIF) and ARIF with level of evidence III and one study was level of evidence I. A total of 217 patients underwent ARIF surgery in our review, the average follow-up time was 24.9 months (12-90 m), in terms of the type of fracture, the most frequent were Schatzker II tibial plateau fractures and III, the most frequent associated injury was meniscal injury followed by anterior cruciate ligament tear. Regarding the total percentage of results obtained independently of each score used, approximately 98% obtained good or excellent results. The percentage of complications with arthroscopic assistance turned out to be approximately 6.5%, the most frequent complication being deep vein thrombosis with 6 cases. Conclusions: From our review we can conclude that arthroscopic assistance is useful in the treatment of Schatzker I-IV tibial plateau fractures, since it provides satisfactory functional results, without increasing the number of complications and allows treating associated injuries simultaneously.


Objetivo: o objetivo deste estudo é explorar e descrever os resultados e experiências no tratamento das fraturas do planalto tibial de Schatzker1 I-IV com auxílio artroscópico para obter redução como parte da técnica de fixação interna (ARIF). Metodologia: : Foi realizada uma busca sistemática em diferentes motores de busca, como Pubmed e Lilacs. Foi pesquisado com a mesma metodologia por 2 revisores independentes usando os termos do MESH "Tibial Fracture", "Arthroscopic". Foram incluídos artigos publicados nos últimos 5 anos (2014 a setembro de 2020), mostrando resultados clínicos dos procedimentos, em inglês ou espanhol, em humanos e maiores de 18 anos. Resultados: Seguindo os critérios de inclusão, 114 títulos foram identificados e, finalmente, 9 artigos foram incluídos em nossa revisão sistemática. Dos 9 artigos revisados, 5 correspondem a séries de casos com nível de evidência IV, 3 correspondem a estudos comparativos retrospectivos entre técnicas de redução aberta e fixação interna (ORIF) e ARIF com nível de evidência III e um estudo corresponde a nível de evidência . evidências I. Um total de 217 pacientes foram submetidos a ARIF em nossa revisão, o tempo médio de acompanhamento foi de 24,9 meses (12-90 m), em termos do tipo de fratura, as mais frequentes foram as fraturas do planalto tibial de Schatzker II e III , a lesão associada mais frequente foi a lesão meniscal seguida de ruptura do ligamento cruzado anterior. Em relação ao percentual total de resultados obtidos independentemente de cada escore utilizado, aproximadamente 98% obtiveram resultados bons ou excelentes. O percentual de complicações operadas com assistência artroscópica revelou-se em torno de 6,5%, sendo a complicação mais frequente a trombose venosa profunda com 6 casos. Conclusões: Da nossa revisão podemos concluir que a assistência artroscópica é útil no tratamento das fraturas do planalto tibial de Schatzker I-IV, sendo uma técnica que fornece resultados funcionais satisfatórios, sem aumentar o número de complicações e permite tratar lesões associadas no mesmo ato.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Arthroscopy/methods , Tibial Fractures/surgery , Arthroscopy/adverse effects , Tibial Fractures/classification
20.
Acta ortop. mex ; 35(4): 322-326, jul.-ago. 2021. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1374194

ABSTRACT

Resumen: Introducción: Las fracturas de platillo tibial por mecanismos de alta energía son lesiones graves que ocurren sobre una articulación de carga. Son difíciles de abordar, ya que además de afectar la estructura ósea de la pierna suelen tener lesiones de partes blandas asociadas. Objetivo: Evaluar los resultados radiológicos y funcionales de las fracturas de platillo tibial de alta energía con un mínimo seguimiento de un año. Material y métodos: Estudio retrospectivo, observacional y multicéntrico. Análisis de los resultados radiológicos y funcionales en el tratamiento de fracturas de platillo tibial de alta energía tratadas mediante reducción abierta y fijación interna (RAFI) entre 2014 y 2019. Resultados: 54 fracturas tratadas mediante RAFI. Seguimiento un año, 98.1% de consolidación en 13 semanas de promedio, 83.4% sin alteraciones del eje en plano coronal, 74% sin ensanchamiento articular postoperatorio. Escalas funcionales: Lysholm 82.1 puntos promedio y Oxford Knee Score (OKS) 39.5 puntos promedio. Conclusión: El rango de movilidad articular se redujo luego de una fractura de platillos tibiales de alta energía, pero con buenos resultados funcionales. Cuanto menor deseje y menor ensanchamiento radiográfico postoperatorio, se obtienen mejores resultados.


Abstract: Introduction: The tibial plateau fractures due to high-energy mechanisms are serious injuries that occur on a load bearing joint. These are difficult to approach because, also affect the bone structure of the leg, they usually have associated soft tissue injuries. Objective: To evaluate the radiological and functional results of high-energy tibial plateau fractures with a minimum follow-up of one year. Material and methods: Retrospective, observational and multicenter study. Analysis of radiological and functional outcomes in the treatment of high-energy tibial plateau fractures, treated by open reduction and internal fixation (ORIF) between 2014 and 2019. Results: 54 fractures treated by ORIF. Follow-up one year. 98.1% consolidation in 13 weeks on average. 83.4% without alterations of the axis in the coronal plane. 74% without postoperative joint widening. Functional scores: Lysholm 82.1 average points and Oxford Knee Score (OKS) 39.5 average points. Conclusion: The joint range of motion was reduced after a high-energy tibial plateau fracture, but with good functional results. The less off axis and less post-operative radiographic widening, the better results are obtained.

SELECTION OF CITATIONS
SEARCH DETAIL