1.
Chinese Journal of General Surgery ; (12): 44-49, 2023.
Article in Chinese | WPRIM | ID: wpr-994545

ABSTRACT

Objective:To investigate the feasibility of multi-slice spiral CT (MSCT) imaging feature of gastric stromal tumor (GST) in evaluating Ki-67 index expression .Methods:The clinical and CT imaging data of 501 patients with GST confirmed by surgery and pathology were retrospectively studied in Zhongshan Hospital affiliated to Fudan University and the Affiliated TCM Hospital of Southwest Medical University from Nov 2014 to Nov 2021. By immunohistochemical results, tumors were divided into Ki-67 low expression group (Ki-67≤6%, 335 lesions) and high expression group (Ki-67>6%, 168 lesions). Multivariate logistic regression analysis was conducted.Results:Between the two groups,there were statistical differences in the longest and shortest diameter of tumor, CT value on venous phase, CT attenuation value ( Z=4.80, 4.91, 3.21, 3.29, all P<0.01) and tumor location,morphology, necrosis, ulcer, feeding artery, vascular enhancement, positive fat sign around disease, gastrointestinal bleeding ( χ2=10.77, 13.49, 8.59, 22.87, 7.59, 7.23, 7.76, 8.58, all P<0.05). Tumor ulceration positive ( OR=1.88, 95%CI: 1.17-3.03) was independent risk factor of Ki-67 high expression ( P=0.009). Gastric antrum was used as the reference for tumor location, cardia ( OR=5.41, 95% CI:1.25-23.46) was independent risk factor of Ki-67 high expression ( P=0.024). Conclusion:MSCT has a definite predictive value for the expression in Ki-67 index of GST cases.

2.
Chinese Journal of Urology ; (12): 484-489, 2022.
Article in Chinese | WPRIM | ID: wpr-957414

ABSTRACT

Objective:To explore clinical value of prostate target biopsy guided by multiparametric magnetic resonance imaging (mpMRI) and 68Ga-labeled prostate specific membrane antigen ligand imaging positron emission tomography/X-ray computed tomography ( 68Ga-PSMA PET/CT) image fusion. Methods:The data of 50 patients admitted to Fudan University Shanghai Cancer Center from January 2021 to February 2022 who underwent mpMRI and 68Ga-PSMA PET/CT to guide prostate biopsy were retrospectively analyzed. The median age was 70 (63-79) years, the median serum tPSA value was 8.1 (6.8-83.0) ng/ml, and the prostate volume was 45.5 (30-80) ml. 36 cases were positive by mpMRI, including PI-RADS score 3 in 5 cases, 4 score in 19 cases, 5 score in 12 cases. 32 cases were positive by 68Ga-PSMA PET/CT examination, of which 30 cases were double positive and the fusion of both imaging techniques was positive, referred to as PET/CT-MRI. The patient's mpMRI and 68Ga-PSMA PET/CT images were imported into the MIM fusion software, and the outline of the prostate and the target area were outlined respectively. When PET/CT and MRI double positive cases were biopsied, the two images were alternately fused, calibrated and locked with the real-time prostate ultrasound interface(PET/CT-MRI). Single-positive cases were guided by positive images to complete targeted biopsy, and 12-needle systematic biopsies were completed after targeted biopsy and double-negative cases. The advantages of targeted biopsy and systematic biopsy was evaluated, and the diagnostic performance (sensitivity, specificity, positive predictive value, and negative predictive value) was analyzed. Results:Among the 50 biopsy patients in this group, 31 (62%) had prostate cancer, of which 22 (44%) were CsPCa. There was no significant difference in the detection rate of prostate cancer between targeted biopsy and systematic biopsy [78.9% (30/38) and 62.0% (31/50), P=0.088], and there was no significant difference in the detection rate of CsPCa [57.9% (22/38) and 40.0% (20/50), P=0.096]. The positive rate of the biopsy needles number was significantly different [86.3% (69/80) and 19.0% (114/ 600), P<0.001]. The detection rates of prostate cancer in mpMRI positive, PET/CT positive and PET/CT-MRI positive cases were 83.3% (30/36), 90.6% (29/32) and 96.6% (29/30) respectively, the detection rates of CsPCa were 61.1% (22/36), 68.8% (22/32) and 73.3% (22/30) respectively.The sensitivity, specificity, positive predictive value and negative predictive value of mpMRI in the diagnosis of prostate cancer were 96.8%(30/31), 68.4%(13/19), 83.3%(30/36)and 92.9%(13/14), respectively.Those values in 68Ga-PSMA PET/CT were 93.5%(29/31), 84.2%(16/19), 90.6%(29/32)and 88.9%(16/18), respectively.Those values in PET/CT-MRI were 93.8%(29/31), 94.7%(18/19), 96.7%(29/30)and 90.0%(18/20), respectively. The above four indicators of mpMRI diagnosis of CsPCa were 100.0%(22/22), 50.0%(14/28), 61.1%(22/36)and 100.0%(14/14), respectively.Those indicators in 68Ga-PSMA PET/CT were 100.0%(22/22), 64.3%(18/28), 68.8%(22/32)and 100.0%(18/18), respectively.Those indicators in PET/CT-MRI was 100.0%(22/22), 71.4%(20/28), 73.2%(22/30)and 100.0%(20/20), respectively. The detection efficiency of PET/CT-MRI was better than that of mpMRI (Kappa value was 0.737, P=0.031). Conclusions:PET/CT-MRI image fusion-guided targeted prostate biopsy can effectively improve the detection efficiency of prostate cancer and clinically significant prostate cancer, and increase the positive rate.

3.
Chinese Journal of Medical Imaging Technology ; (12): 411-414, 2020.
Article in Chinese | WPRIM | ID: wpr-861086

ABSTRACT

Objective: To observe the clinical application value of chest low-dose CT (LDCT) in auxiliary diagnosis of corona virus disease 2019 (COVID-19). Methods: Totally 50 COVID-19 patients with positive 2019 novel coronavirus nucleic acid test of pharynx swabs were selected. All patients underwent routine dose chest CT examination on the first time (routine dose group), and followed chest LDCT for the review examination after treatment (LD group). The image quality of was evaluated by 2 imaging doctors. Kappa test was used to analyze the consistency of the image quality Results: of 2 groups evaluated by the two physicians. The X-ray radiation dose of the two CT scanning schemes were compared. Results: The consistency of image quality scores of 2 groups evaluated by 2 physicians was relatively high (Kappa=0.65, P<0.05). There was no significant difference of image quality between LD group and routine dose group (Z=-0.93, P=0.35). The effective radiation dose (ED)in LD group ([2.43±0.66]mSv) reduced by 39.55% (t=0.85, P<0.01) compared with that of the routine dose group ([4.02±1.03]mSv). Conclusion: Chest LDCT scan can be used for clinical screening and auxiliary diagnosis of COVID-19, which can ensure the image quality, meet clinical diagnosis requirements and reduce the dose of X-ray radiation.

4.
Chinese Journal of General Surgery ; (12): 402-405, 2011.
Article in Chinese | WPRIM | ID: wpr-417027

ABSTRACT

Objective To evaluate perfusion computed tomography in the assessment of portal vein pressure changes in an experimental dog model of liver cirrhosis and portal hypertension.Methods The canine model of cirrhosis and portal hypertension was induced by portal vein stenosis with combination of systemic thioacetamide(TAA) feeding in drinking water.All of the Beagles in control group and cirrhotic group underwent hepatic perfusion on a spiral CT scanner.The parameters of hepatic perfusion were calculated by the method of deconvolution.The portal vein pressure was measured by a laparotomy surgery.Results ① In control group, the portal vein pressure was ( 14.5 ± 2.2) cm H2O, while it was (23.1 ± 2.8) cm H2O in PHT group, there was significant difference in the portal vein pressure between the two groups (P<0.05).② The blood flow(BF) was (112 ±14) ml·100 g-1·min-1 in controls, while ( 96 ± 11) ml·100 g-1·min-1 in PHT group; the blood volume ( BV ) in control group and PHT group was (10 ±3) ml·100 g-1 and (11 ± 5) ml· 100 g-1, respectively; the mean transit time( MTT) was (7.1 ± 2.0) s and (10.4 ± 3.5) s, respectively; the hepatic arterial fraction (HAF) was ( 24 ± 5) % and ( 37 ± 6)% , respectively; the hepatic arterial perfusion (HAP) was(27 ±6) ml·100 g-1·min-1 and (35 ±5) ml·100 g-1·min-1, respectively; the portal venous perfusion (PVP) was (85 ± 13) ml·100 g-1·min-1 and (61 ±11) ml·100 g-1·min-1, respectively.There was significant difference in all parameters between the two groups except the parameter BV(P < 0.05).③ In PHT group, the PVP and BF were negatively correlated with the portal vein pressure, while positively correlated with MTT and HAF.Portal vein pressure was negatively correlated with PVP, the equation, Y = 36.624 -0.219X, was deduced with linear regression analysis, by which the portal vein pressure in PHT Beagles was ( 23.2 ± 2.4) cm H2O, which was correlated with the observed by laparotomy value (23.1 ± 2.8) cm H2O (r = 0.843, P < 0.05).Conclusion CT perfusion is a new non-invasive and effective method for assessment of portal vein pressure.

5.
Journal of Practical Radiology ; (12): 216-218, 2010.
Article in Chinese | WPRIM | ID: wpr-403282

ABSTRACT

Objective To study of the imaging diagnosis and differential diagnosis of cystitis glandularis. Methods The clinical data and imaging findings of 8 cases with cystitis glandularis proved by pathology were retrospectively analyzed with literaures re-view. Results The lesions on images appeared as nodular mass in 4 cases, diffuse in 2 cases and mixed type in 2 cases,1 case with cystic degeneration. The lesions in 2 cases obviously reduced in size after treatment. The CT value of the lesions post contrast-en-hanced scan averagely increased up to 15.8 HU compared with that of plain scan. The lesions were localized in 6 cases and diffuse in 2 cases. Conclusion cystitis galandularis has some imaging characteristics, but the final diagnosis is depended on pathology.

6.
Chinese Journal of Radiology ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-557485

ABSTRACT

Objective To assess the cli ni cal usefulness of dual-modality positron emission tomographic (PET)-computed t omographic (CT) imaging in pulmonary lesions. Methods Fo rty-nine patients with pulmonary lesions examined with ?~2 test. Results There were 50 primary lesions in 49 patients. Accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predict ive value (NPV) were 90.0%, 95.2%, 62.5%, 93.0%, and 71.4%, respectively wi th PET-CT, 74.0%, 76.2%, 62.5%, 91.4%, and 33.3%, respectively with CT. There was significant differences between them (P0.05). Conclusion PET-C T has an important clinical value in differentiating benign lesion from malignan cy and staging in lung cancer.

7.
Chinese Journal of Radiology ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-551718

ABSTRACT

Objective To study the CT findings and diagnostic role in morning glory syndrome (MGS). Methods CT study of 7 patients with MGS diagnosed by clinical information was reviewed retrospectively. Results CT findings included: (1) the crater like excavation of the disc in 3 patients; (2) the funnel shaped widening of the retrobulbar optic nerve, a pear shaped deformity of the globe in 2 patients; (3) two patients with cystic expansion of the optic nerve, which was of water density and was continuous with the vitreous humor. Conclusion The CT findings of MGS were particularly striking. CT is the imaging method of choice in the diagnosis of this disorder.

SELECTION OF CITATIONS