Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. bras. oftalmol ; 77(3): 119-123, May-June 2018. tab
Article in Portuguese | LILACS | ID: biblio-959081

ABSTRACT

Resumo Objetivo: A catarata é a principal causa de cegueira reversível no mundo e seu tratamento é baseado em cirurgia, facectomia. A evolução do procedimento tem se baseado em vários pilares, mas é no desenvolvimento de novos tipos de lentes intraoculares que vem mostrando inovações consideráveis. As lentes atuais são capazes, além de tratar a catarata, de corrigir erros refracionais. O objetivo deste estudo foi avaliar a qualidade de vida e de visão pós-facectomia, comparando as lentes multifocais (Restor), tóricas, monofocais esféricas (SN60AT) e monofocais asféricas. Métodos: A pesquisa abrangeu 54 pacientes submetidos a facectomia com implantação de uma das lentes há, pelo menos, 3 meses. Os pacientes responderam questionário de qualidade de vida Cataract TyPE Specification sobre satisfação de visão, dependência de óculos para diversas atividades diárias e presença de fenômenos disfóticos. Para análise dos dados foram utilizados os testes de Kolmogorov-Smirnov, quanto a normalidade e ANOVA com teste de Tukey, quanta parametria. Em comparações não paramétricas, utilizou-se o teste de Mann-Whitney. Em todas as análises foi usado o mesmo nível de significância (p<0,05). Resultados: Numa escala de 0 a 10, a pesquisa mostrou que as lentes SN60AT, esféricas monofocais, foram as que obtiveram menor nível de satisfação entre as 4 lentes, obtendo média de 8,7 (DP= 1,30; IC ± 0,655), seguido das esféricas monofocais (média= 8,3 - DP= 1,83; IC ± 0,927), das esféricas multifocais (Restor) (média = 8,9 - DP = 1,42; IC ± 0,721) e as tóricas (média = 9,1 - DP = 1,67; IC ± 0,844) como a de maior nível de satisfação. Em relação à dependência dos óculos, a lente Restor foi a que mostrou melhor desempenho, com menor dependência dos óculos. Fenômenos disfóticos foram mais frequentes nos pacientes que tiveram implantada a lente SN60AT seguida de lente Restor. Conclusão: Conclui-se que as lentes SN60AT foram as lentes que causaram menor grau de satisfação, tendo os fenômenos disfóticos umas das principais queixas, associada a dependência dos óculos pós-cirurgia. Os pacientes que tiveram as lentes Restor implantadas, apesar dos sintomas disfóticos mais presentes do que as lentes monofocais tóricas e monofocais esféricas, tem o mesmo nível de satisfação, e ainda proporciona maior independência dos óculos.


Abstract Objective: Cataract is the leading cause of reversible blindness in the world and its treatment is based on surgery, facectomy. The evolution of the procedure has been based on several pillars, but it is in the development of new types of intraocular lenses that has been showing considerable innovations. Current lenses are capable, in addition to treating cataracts, of correcting refractive errors. The aim of this study was to evaluate the quality of life and post-facectomy vision, comparing multifocal lenses (Restor), toric, spherical monofocals (SN60AT) and aspheric monofocals. Methods: The study included 54 patients undergoing a facectomy with implantation of one of the lenses for at least 3 months. The patients answered questionnaire quality of life Cataract TyPE Specification on vision satisfaction, glasses dependence for various daily activities and presence of dysphothetic phenomena. For the analysis of the data, the Kolmogorov-Smirnov tests were used, regarding normality and ANOVA with Tukey's test, how much parametric. In non-parametric comparisons, the Mann-Whitney test was used. In all analyzes, the same level of significance was used (p <0.05). Results: On a scale of 0 to 10, the research showed that single-spherical spherical SN60AT lenses were the ones that obtained the lowest level of satisfaction among the four lenses, obtaining an average of 8.7 (SD = 1.30, CI ± 0.655), followed (mean = 8.9 - SD = 1.42, CI ± 0.721) and the toric (mean = 8.3 - SD = 1.83, CI ± 0.927), multifocal spherical (Restor) 9.1 - SD = 1.67, CI ± 0.844) as the highest level of satisfaction. Regarding the dependence of the glasses, the Restor lens showed the best performance, with less dependence on the glasses. Dysphasic phenomena were more frequent in patients who had implanted the SN60AT lens followed by Restor lens. Conclusion: It is concluded that the SN60AT lenses were the lenses that caused less satisfaction, and the dysphothetic phenomena were one of the main complaints, associated with the postoperative glasses dependence. Patients who had restored Restor lenses, despite the more present dysphoric symptoms than spherical monofocal and single-focal lenses, have the same level of satisfaction, and still provide greater independence of the glasses.


Subject(s)
Humans , Male , Female , Aged , Quality of Life , Cataract Extraction/psychology , Lens Implantation, Intraocular/psychology , Lenses, Intraocular , Postoperative Period , Vision, Ocular , Cataract Extraction/methods , Visual Acuity , Prospective Studies , Surveys and Questionnaires , Patient Satisfaction , Lens Implantation, Intraocular/methods , Eyeglasses/psychology
2.
Indian J Ophthalmol ; 2013 Nov ; 61 (11): 626-629
Article in English | IMSEAR | ID: sea-155442

ABSTRACT

Purpose: To assess the visual outcome and rotational stability of single‑piece open loop toric Intra Ocular Lens (IOL) in a clinical setting. Materials and Methods: In a prospective study, 122 eyes of 77 patients were followed up for a period of 12 months after cataract surgery with toric open loop IOL implantation. The pre‑operative markings for the position of incision and IOL placement were done under slit lamp by anterior stromal puncture. The visual acuity, refraction, and IOL position were assessed at day 1, 1 week, 1 month, 3 months, 6 months, and 12 months after surgery. Results: The mean age of the cohort was 56 yrs (S.D. 13.88; range 16 to 87 years). The mean pre‑operative cylinder of corneal astigmatism was 1.37 D. (SD 0.79, range 1.0 to 5.87 D). Mean post‑operative refractive cylinder was 0.36 D (SD 0.57, range 0 to 1.50 D) at 12 months. Ninety‑seven percent of the eyes were within 1 D of residual astigmatism. Ninety‑four percent of patients had uncorrected visual acuity of 20/30 or better. Four eyes required IOL repositioning due to rotation. At 12 months, 96.7% of the IOLs were within 10 degrees of the target axis. There was no rotation seen after 6 months. Conclusion: Toric IOLs are very effective and consistent in correcting astigmatism during the cataract surgery. IOL rotation happens mostly within a month of surgery, and if significant, requires early repositioning.

3.
Indian J Ophthalmol ; 2011 Jan; 59(1): 60-62
Article in English | IMSEAR | ID: sea-136143

ABSTRACT

We report a new procedure for intra-operative toric intra-ocular lens (IOL) axis assessment in order to achieve optimal implantation. IOL implantation procedure was directly recorded. An assessor estimated the angle formed by the marked 0–180 axis and the toric IOL axis after implantation with the use of the appropriate software. If IOL implantation was assessed to be inaccurate, the surgeon was advised to correct IOL positioning by rotating the IOL clockwise. The assessment procedure was repeated until accurate IOL positioning was achieved.


Subject(s)
Equipment Design , Humans , Intraoperative Care , Lens Implantation, Intraocular/methods , Lenses, Intraocular , Prosthesis Fitting/instrumentation , Prosthesis Fitting/methods , Rotation , Software
SELECTION OF CITATIONS
SEARCH DETAIL