Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 752
Filter
1.
Rev. bras. cir. cardiovasc ; 39(2): e20220436, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1535538

ABSTRACT

ABSTRACT Introduction: The aim of this study was to assess the impact of aortic angulation (AA) on periprocedural and in-hospital complications as well as mortality of patients undergoing Evolut™ R valve implantation. Methods: A retrospective study was conducted on 264 patients who underwent transfemoral-approach transcatheter aortic valve replacement with self-expandable valve at our hospital between August 2015 and August 2022. These patients underwent multislice computer tomography scans to evaluate AA. Transcatheter aortic valve replacement endpoints, device success, and clinical events were assessed according to the definitions provided by the Valve Academic Research Consortium-3. Cumulative events included paravalvular leak, permanent pacemaker implantation, new-onset stroke, and in-hospital mortality. Patients were divided into two groups, AA ≤ 48° and AA > 48°, based on the mean AA measurement (48.3±8.8) on multislice computer tomography. Results: Multivariable logistic regression analysis was performed to identify predictors of cumulative events, utilizing variables with a P-value < 0.2 obtained from univariable logistic regression analysis, including AA, age, hypertension, chronic renal failure, and heart failure. AA (odds ratio [OR]: 1.73, 95% confidence interval [CI]: 0.89-3.38, P=0.104), age (OR: 1.04, 95% CI: 0.99-1.10, P=0.099), hypertension (OR: 1.66, 95% CI: 0.82-3.33, P=0.155), chronic renal failure (OR: 1.82, 95% CI: 0.92-3.61, P=0.084), and heart failure (OR: 0.57, 95% CI: 0.27-1.21, P=0.145) were not found to be significantly associated with cumulative events in the multivariable logistic regression analysis. Conclusion: This study demonstrated that increased AA does not have a significant impact on intraprocedural and periprocedural complications of patients with new generation self-expandable valves implanted.

2.
Rev. bras. cir. cardiovasc ; 39(2): e20220470, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1535548

ABSTRACT

ABSTRACT Introduction: Goal-directed fluid therapy (GDFT) has been shown to reduce postoperative complications. The feasibility of GDFT in transcatheter aortic valve replacement (TAVR) patients under general anesthesia has not yet been demonstrated. We examined whether GDFT could be applied in patients undergoing TAVR in general anesthesia and its impact on outcomes. Methods: Forty consecutive TAVR patients in the prospective intervention group with GDFT were compared to 40 retrospective TAVR patients without GDFT. Inclusion criteria were age ≥ 18 years, elective TAVR in general anesthesia, no participation in another interventional study. Exclusion criteria were lack of ability to consent study participation, pregnant or nursing patients, emergency procedures, preinterventional decubitus, tissue and/or extremity ischemia, peripheral arterial occlusive disease grade IV, atrial fibrillation or other severe heart rhythm disorder, necessity of usage of intra-aortic balloon pump. Stroke volume and stroke volume variation were determined with uncalibrated pulse contour analysis and optimized according to a predefined algorithm using 250 ml of hydroxyethyl starch. Results: Stroke volume could be increased by applying GDFT. The intervention group received more colloids and fewer crystalloids than control group. Total volume replacement did not differ. The incidence of overall complications as well as intensive care unit and hospital length of stay were comparable between both groups. GDFT was associated with a reduced incidence of delirium. Duration of anesthesia was shorter in the intervention group. Duration of the interventional procedure did not differ. Conclusion: GDFT in the intervention group was associated with a reduced incidence of postinterventional delirium.

3.
Rev. bras. cir. cardiovasc ; 39(3): e20230267, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1559392

ABSTRACT

ABSTRACT Objective: Sleep quality in those with cardiovascular disease is significantly lower than in the general population. This study aimed to explore the effect of transcatheter or surgical closure of atrial septal defect (ASD) on sleep quality. Methods: One hundred nineteen adult patients with ASD who underwent transcatheter or surgical closure were included in the study. Sleep quality was investigated prospectively just before defect closure and six months after defect closure. Pittsburgh Sleep Quality Index (PSQI) was used to evaluate sleep quality of these patients. Results: PSQI scores were similar in both groups before the procedure in patients who underwent both transcatheter and surgical closure. The PSQI scores six months after transcatheter closure was significantly improved compared to the PSQI score before transcatheter ASD closure (3.5 ± 2.0 vs. 6.9 ± 3.4, respectively; P<0.001). The PSQI scores six months after surgical ASD closure was significantly improved compared to the PSQI score before surgical closure (4.8 ± 2.1 vs. 7.1 ± 2.0, respectively; P<0.001). Total PSQI scores were also statistically different at six months after transcatheter and surgical closure (3.5 ± 2.0 vs. 4.8 ± 2.1, P=0.014). However, six months after both transcatheter and surgical closure, PSQI scores were significantly decreased in both groups which was more pronounced in patients who underwent transcatheter closure. Conclusion: Transcatheter or surgical closure of the defect may be beneficial in improving the sleep quality of adult patients with ASD. Delayed improvement of sleep quality after surgical closure may be an important advantage for transcatheter closure.

4.
Organ Transplantation ; (6): 138-144, 2024.
Article in Chinese | WPRIM | ID: wpr-1005244

ABSTRACT

With the maturity of kidney transplantation, introduction of new immunosuppressive drugs and improvement of immunosuppressive regimen, the short-term survival rate of kidney transplant recipients has been significantly improved, whereas the long-term survival rate has not been significantly elevated. Kidney transplant recipients may have the risk of renal graft loss. Clinical management after renal graft loss is complicated, including the adjustment of immunosuppressive drugs, management of renal graft and selection of subsequent renal replacement therapy. These management procedures directly affect clinical prognosis of patients with renal graft loss. Nevertheless, relevant guidelines or consensuses are still lacking. Clinical management of patients after renal graft loss highly depend upon clinicians’ experience. In this article, the adjustment of immunosuppressive drugs, management of renal graft and selection of subsequent renal replacement therapy were reviewed, aiming to provide reference for prolonging the survival and improving the quality of life of these patients.

5.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 269-275, 2024.
Article in Chinese | WPRIM | ID: wpr-1013507

ABSTRACT

@#Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.

6.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 181-185, 2024.
Article in Chinese | WPRIM | ID: wpr-1013487

ABSTRACT

@#Transcatheter edge-to-edge repair (TEER) for mitral regurgitation (MR) is known as M-TEER. Its strengths include: precise targets and fewer implants; simple and clear principles for catheterization; originating from dependable medical concepts and broad applicability. Furthermore, TEER offers advantages in real-time hemodynamic and effectiveness measurement throughout the procedure over surgical edge-to-edge repair (SEER). When it comes to patients with degenerative mitral regurgitation , M-TEER should aim to deliver more optimum procedural outcomes. In functional mitral regurgitation, a modest transvalvular gradients or moderate residual shunt can be tolerated with M-TEER, which reduces the risk of problems and has no bearing on the patient's prognosis.

7.
Rev. bras. cir. cardiovasc ; 39(1): e20220461, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1521679

ABSTRACT

ABSTRACT Introduction: There is no consensus on the impact of coronary artery disease in patients undergoing transcatheter aortic valve implantation. Therefore, the objective of this study was, in a single-center setting, to evaluate the five-year outcome of transcatheter aortic valve implantation patients with or without coronary artery disease. Methods: All transcatheter aortic valve implantation patients between 2009 and 2019 were included and grouped according to the presence or absence of coronary artery disease. The primary endpoint, five-year all-cause mortality, was evaluated using Cox regression adjusted for age, sex, procedure years, and comorbidities. Comorbidities interacting with coronary artery disease were evaluated with interaction tests. In-hospital complications was the secondary endpoint. Results: In total, 176 patients had aortic stenosis and concomitant coronary artery disease, while 170 patients had aortic stenosis only. Mean follow-up was 2.2±1.6 years. There was no difference in the adjusted five-year all-cause mortality between transcatheter aortic valve implantation patients with and without coronary artery disease (hazard ratio 1.00, 95% confidence interval 0.59-1.70, P=0.99). In coronary artery disease patients, impaired renal function, peripheral arterial disease, or ejection fraction < 50% showed a significant interaction effect with higher five-year all-cause mortality. No significant differences in complications between the groups were found. Conclusion: Five-year mortality did not differ between transcatheter aortic valve implantation patients with or without coronary artery disease. However, in patients with coronary artery disease and impaired renal function, peripheral arterial disease, or ejection fraction < 50%, we found significantly higher five-year all-cause mortality.

8.
Rev. argent. cardiol ; 91(4): 257-262, nov. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535503

ABSTRACT

RESUMEN La difusión del reemplazo valvular aórtico percutáneo (TAVI) en la estenosis aórtica (EAo) generó la creación de un Heart Team (HT), para elegir el mejor tratamiento. Existen pocos reportes sobre su utilidad. Objetivos: analizar los resultados del tratamiento de los pacientes con EAo evaluados por un HT durante 10 años Material y métodos: Inclusión consecutiva de todos los pacientes con EAo candidatos a TAVI entre enero del 2012 y julio del 2021 para seleccionar el mejor tratamiento, incluyendo además Cirugía de reemplazo valvular aórtico (CRVA) y Tratamiento médico conservador (TMC). Resultados: De 841 pacientes, se asignaron a TAVI 455 (53%), CRVA 213 (24%) y TMC 183 (23%). El porcentaje asignado a TAVI aumentó con el tiempo de 48 a 62% (p < 0,05). Los pacientes que fueron a TAVI, con respecto a los enviados a CRVA, eran mayores (86 ± 7 vs 83 ± 7 años), con mayor EUROSCORE II (6,2, IC95% 5,7-6,6 vs 5,6, IC95% 4,4-6,5) y más frágiles (1,62 ± 1 vs 0,91 ± 1), en todos los casos p <0,01. La sobrevida actuarial (IC 95%) a 1 y a 2 años fue, para TAVI 88% (84-91%) y 82% (77-86%), para CRVA 83% (76-88%) y 78% (70-84%) y para TMC 70% (60-87%) y 59% (48-68%) respectivamente (p <0,001). Conclusiones: Durante los primeros 10 años de establecido un Heart Team para la toma de decisiones en EAo, se asignaron a TAVI aproximadamente la mitad y el resto se asignó por mitades a cirugía u observación. La sobrevida de los pacientes intervenidos fue similar a 2 años y mayor que la de los no intervenidos.


ABSTRACT As transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) became widespread, the need for a Heart Team (HT) arose to choose the best treatment. There are few reports regarding its usefulness. Objectives: To analyze treatment outcomes in patients with AS evaluated by a HT for 10 years. Methods: Consecutive enrollment of all patients with AS who were candidates for TAVI between January 2012 and July 2021 to choose the best treatment, including surgical aortic valve replacement (SAVR) and conservative medical management (CMM). Results: Out of 841 patients, 455 were assigned to TAVI (53%), 213 to SAVR (24%), and 183 to CMM (23%). The percentage assigned to TAVI has increased from 48% to 62% over time (p <0.05). Patients who underwent TAVI versus those who underwent SAVR were older (86 ± 7 vs. 83 ± 7 years), had a higher EUROSCORE II (6.2, 95% CI 5.7-6.6 vs. 5.6; 95% CI 4.4-6.5) and were frailer (1.62 ± 1 vs. 0.91 ± 1), in all cases p <0.01. Actuarial survival (95% CI) at 1 and 2 years was 88% (84-91%) and 82% (77-86%) for TAVI, 83% (76-88%) and 78% (70-84%) for SAVR, and 70% (60-87%) and 59% (48-68%) for CMM, respectively (p <0.001). Conclusions: For the first 10 years after a Heart Team was established for AS decision-making, approximately half of the patients were assigned to TAVI, and the rest were equally assigned in halves to either surgery or observation. Survival for patients who received interventions was similar at 2 years and higher than in those who did not.

9.
Article | IMSEAR | ID: sea-219304

ABSTRACT

Transcatheter mitral valve replacement (TMVR) has emerged as a feasible alternative to surgical reoperation in failed bioprostheses and rings. Residual mitral regurgitation following TMVR can present as a valve?in?valve paravalvular leak (PVL) and is associated with increased morbidity and mortality. Current therapies for valve?in?valve PVL are limited. We present a case of a symptomatic patient with severe valve?in?valve PVL after TMVR for a previous surgical bioprosthesis leak, who then underwent a second TMVR as a valve?in?valve?in?valve implantation with a 29 mm Edwards? SAPIEN 3 valve via transseptal approach using three?dimensional (3D) echocardiography. This unique case highlights the complexity of this clinical entity and recognizes 3D transesophageal echocardiography as a valuable tool to guide valve?in?valve PVL closures.echocardiography

10.
ABC., imagem cardiovasc ; 36(1): e20230006, abr. 2023. ilus, tab
Article in Portuguese | LILACS | ID: biblio-1517806

ABSTRACT

A regurgitação tricúspide (RT) importante está associada à alta morbidade e mortalidade. Como o tratamento cirúrgico da RT isolada tem sido associado à alta mortalidade, as intervenções transcateter na valva tricúspide (VT) têm sido utilizadas para o seu tratamento, com risco relativamente mais baixo. Há um atraso na intervenção da RT e provavelmente está relacionado a uma compreensão limitada da anatomia da VT e do ventrículo direito, além da subestimação da gravidade da RT. Nesse cenário, faz-se necessário o conhecimento anatômico abrangente da VT, a fisiopatologia envolvida no mecanismo de regurgitação, assim como a sua graduação mais precisa. A VT tem peculiaridades anatômica, histológica e espacial que fazem a sua avalição ser mais complexa, quando comparado à valva mitral, sendo necessário o conhecimento e treinamento nas diversas técnicas ecocardiográficas que serão utilizadas frequentemente em combinação para uma avaliação precisa. Esta revisão descreverá a anatomia da VT, o papel do ecocardiograma no diagnóstico, graduação e fisiopatologia envolvida na RT, as principais opções atuais de tratamento transcateter da RT e a avaliação do resultado após intervenção transcateter por meio de múltiplas modalidades ecocardiográficas.(AU)


Severe tricuspid regurgitation (TR) is associated with high morbidity and mortality. Given that surgical treatment of TR alone has been associated with high mortality, transcatheter interventions in the tricuspid valve (TV) have been used for its treatment, with relatively lower risk. There is a delay in intervention for TR, and this is probably related to a limited understanding of the anatomy of the TV and the right ventricle, in addition to an underestimation of the severity of TR. In this scenario, it is necessary to have comprehensive anatomical knowledge of the TV, the pathophysiology involved in the mechanism of regurgitation, and more accurate grading. The TV has anatomical, histological, and spatial peculiarities that make its assessment more complex when compared to the mitral valve, requiring knowledge and training in the various echocardiographic techniques that will often be used in combination for accurate assessment. This review will describe the anatomy of the TV, the role of echocardiography in the diagnosis, grading, and pathophysiology involved in TR; the main transcatheter treatment options currently available for TR; and the assessment of outcomes after transcatheter intervention by means of multiple echocardiographic modalities.(AU)


Subject(s)
Humans , Male , Female , Tricuspid Valve/anatomy & histology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/physiopathology , Pericardial Effusion/complications , Tricuspid Valve Insufficiency/mortality , Echocardiography/methods , Echocardiography, Transesophageal/methods , Echocardiography, Doppler, Color/methods , Echocardiography, Three-Dimensional/methods , Endocarditis/complications , Transcatheter Aortic Valve Replacement/methods
11.
Rev. chil. cardiol ; 42(1): 23-30, abr. 2023. tab, graf
Article in Spanish | LILACS | ID: biblio-1441373

ABSTRACT

Introducción: En nuestro medio, el implante percutáneo de prótesis aórtica (TAVI) se encuentra limitado a pacientes más añosos o de mayor riesgo quirúrgico, en quienes frecuentemente se retarda la intervención hasta que presenten signos avanzados de enfermedad. Objetivo: Evaluar el grado de compromiso miocárdico en pacientes sometidos a TAVI y determinar si la magnitud de este compromiso predice los resultados alejados del procedimiento. Métodos: Registro de pacientes sometidos a TAVI en 2 instituciones de Chile. Según la clasificación propuesta por Genereux el año 2017, se clasificaron desde el punto de vista ecocardiográfico como: 1) compromiso de ventrículo izquierdo; 2) compromiso de aurícula izquierda; 3) hipertensión pulmonar / insuficiencia tricuspídea significativa y 4) disfunción de ventrículo derecho. Resultados: Se incluyeron 209 pacientes. Se logró un procedimiento exitoso en 98,6%, registrándose una mortalidad intrahospitalaria de 2,9%. El compromiso cardíaco se extendió más allá de las cavidades izquierdas en 24,7% de los casos (estadíos 3 y 4). A una mediana de seguimiento de 650 días se registró una mortalidad de 26,8%. El compromiso de cavidades derechas (estadíos 3 y 4) se asoció a una mayor mortalidad (39,6% vs 22,1%, log rank p=0,015). En análisis multivariado, este compromiso fue el único factor que de forma independiente predijo mortalidad (HR 1,87, IC 1,01-3,44, p=0,044). Conclusiones: El compromiso de cavidades derechas se asocia a una mayor mortalidad alejada en pacientes sometidos a TAVI. Estos resultados debiesen estimular una derivación precoz de estos pacientes que, aunque añosos y de alto riesgo, tienen buenos resultados intervenidos precozmente.


Background: Locally, Transcatheter Aortic Valve Implantation (TAVI) is limited to very old or high-risk patients, whose intervention is frequently delayed until they develop signs of advanced disease. Aim: To evaluate the degree of myocardial compromise in patients undergoing TAVI and to determine whether the level of this compromise can predict results during follow-up. Methods: Registry of TAVI patients from 2 institutions in Chile. According to the classification proposed by Genereux in 2017, patients were classified based on the echocardiogram as 1) left ventricular compromise; 2) left atrial compromise; 3) pulmonary hypertension / severe tricuspid regurgitation; 4) right ventricular dysfunction. Results: The study included 209 patients. A successful procedure was achieved in 98.6% of cases, with an in-hospital mortality of 2.9%. Cardiac compromise extended beyond left chambers in 24.7% of cases (stages 3 and 4). During follow-up (median of 650 days) mortality was 26.8%. Right chambers involvement (stages 3 and 4) was associated with increased mortality (39.6% vs 22.1%, log rank p=0.015). In multivariate analysis, this compromise was the only factor that independently predicted mortality (HR 1.87, IC 1.01-3.44, p=0,044). Conclusions: Right chambers involvement was associated to increased mortality during follow-up of patients undergoing TAVI. These results should stimulate earlier referral of these high risk and older patients in order to obtain better results following the intervention.


Subject(s)
Humans , Female , Aged , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/classification , Tricuspid Valve Insufficiency , Severity of Illness Index , Echocardiography , Survival Analysis , Multivariate Analysis , Follow-Up Studies , Hospital Mortality , Forecasting , Myocardium/pathology
12.
Medicina (B.Aires) ; 83(1): 126-128, abr. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1430781

ABSTRACT

Resumen Un varón de 49 años ingresó en la unidad de cuidados coronarios, con antecedentes de miocardiopatía dilatada, con función sistólica del ventrículo izquierdo gravemente deteriorada y estenosis aórtica grave de origen bicúspide, sintomático para síncope, ángor y disnea de reciente diagnóstico. Durante la internación evolucionó con shock cardiogénico que requirió doble soporte inotrópico. Por presentar alto riesgo quirúrgico y elevada probabilidad de rechazo ante un eventual trasplante cardiaco, según sus estudios de histocompatibilidad, se procedió al reemplazo transcatéter de la válvula aortica, con evolución favorable.


Abstract A 49-year-old male with a history of left ventricular systolic function dilated cardiomyopathy and severe symptomatic bicuspid aortic stenosis recently diagnosed (syncope, chest pain and dyspnea) was admitted to the coronary care unit. During hospitalization, he developed cardiogenic shock requiring double inotropic support. High surgical risk and an elevated chance of graft rejection contraindicated surgical replacement or heart transplant. We performed a transcatheter aortic valve replacement with a favorable evolution.

14.
Rev. argent. cardiol ; 91(1): 20-26, abr. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1529566

ABSTRACT

RESUMEN Objetivo : Analizar si la estrategia del implante alto usando superposición de las cúspides derechas e izquierdas (Cusp Overlap, COVL) en el implante percutáneo de la válvula aórtica (TAVI) se relaciona con menor incidencia de regurgitación paravalvular (RPV) moderada o grave, comparada con la estrategia convencional (CON). Material y métodos : Se analizaron 206 pacientes consecutivos que recibieron TAVI con válvulas autoexpandidles entre agosto de 2019 y mayo de 2022. Se utilizó una estrategia CON en 101 pacientes (49%) y COVL en 105 (51%). El Punto Final Primario (PFP) fue la presencia de regurgitación paravalvular moderada y grave a 30 días. Resultados : No hubo diferencia clínica entre los grupos en cuanto a la edad media, sexo ni comorbilidades; excepto una tendencia a más diabetes y angioplastia coronaria previa en el grupo COVL. El STS score fue mayor en el grupo de COVL (6,9 ± 2,2 vs. 5,8 ± 2,4 en CON, p = 0,01). A 30 días no hubo diferencia en el PFP (RPV moderada en 2% en CON, y 0,9% en COVL; ninguno presentó RPV grave). Tampoco hubo diferencia en mortalidad, infarto, oclusión coronaria, accidente cerebrovascular, sangrado mayor y complicación vascular. La necesidad de marcapasos definitivo fue menor con la estrategia de COVL (6,7% vs. 17,8%, p = 0,01) y un nuevo bloqueo de rama izquierda ocurrió en 5,7% vs. 12,9% (p = 0,07). Conclusiones : En esta serie de un solo centro, la estrategia del implante alto de la válvula aórtica percutánea usando la técnica de COVL no demostró diferencia en la presencia de regurgitaciones moderadas o graves comparada con la estrategia convencional, sin presentar diferencia en las complicaciones, y se asoció a una menor necesidad de marcapasos definitivo y a una tendencia de menos bloqueos de rama izquierda a 30 días.


ABSTRACT Objective : The aim of this study is to whether higher transcatheter aortic valve implantation (TAVI) with self-expandable valves using the right and left cusp overlap strategy (Cusp Overlap, COVL) is associated with a lower incidence of moderate or severe paravalvular regurgitation, compared with the conventional strategy (CON). Methods : A total of 206 consecutive patients undergoing TAVI with self-expandable valves between August 2019 and May 2022 were analyzed. The CON technique was used in the first 101 patients (49%) and COVL was used in 105 (51%). The primary endpoint (PEP) was the presence of moderate or severe paravalvular regurgitation at 30 days. Results : There were no clinical differences between the groups in terms of mean age, sex or comorbidities, except for a trend towards more patients with diabetes and previous percutaneous coronary intervention in the COVL group. The STS score was greater in the COVL group (6.9 ± 2.2 vs. 5.8 ± 2.4 in the CON group; p = 0.01). There was no difference in the PEP at 30 days with 2% incidence of moderate PVR in the CON group and 0.9% in the COVL group, and none of them presented severe PVR. There were no differences in mortality, myocardial infarction, coronary artery obstruction, stroke, major bleeding or vascular complications. The need for permanent pacemaker was lower with the COVL strategy (6.7% vs. 17.8%, p = 0.01) and a new left bundle branch block occurred in 5.7% vs. 12.9% (p = 0.07). Conclusions : In this single-center series, the strategy of high transcatheter aortic valve implantation using the COVL strategy showed no difference in the presence of moderate or severe regurgitation compared with the conventional strategy, with no differences in complications, and was associated with a lower need for definitive pacemaker and with a trend towards lower incidence of left bundle branch block at 30 days.

15.
Article | IMSEAR | ID: sea-219307

ABSTRACT

Background: General anesthesia has traditionally been used in transcatheter aortic valve replacement; however, there has been increasing interest and momentum in alternative anesthetic techniques. Aims: To perform a descriptive study of anesthetic management options in transcatheter aortic valve replacements in the United States, comparing trends in use of monitored anesthesia care versus general anesthesia. Settings and Design: Data evaluated from the American Society of Anesthesiologists� (ASA) Anesthesia Quality Institute抯 National Anesthesia Clinical Outcomes Registry. Materials and Methods: Multivariable logistic regression was used to identify predictors associated with use of monitored anesthesia care compared to general anesthesia. Results: The use of monitored anesthesia care has increased from 1.8% of cases in 2013 to 25.2% in 2017 (p = 0.0001). Patients were more likely ages 80+ (66% vs. 61%; p = 0.0001), male (54% vs. 52%; p = 0.0001), ASA physical status > III (86% vs. 80%; p = 0.0001), cared for in the Northeast (38% vs. 22%; p = 0.0001), and residents in zip codes with higher median income ($63,382 vs. $55,311; p = 0.0001). Multivariable analysis revealed each one-year increase in age, every 50 procedures performed annually at a practice, and being male were associated with 3% (p = 0.0001), 33% (p = 0.012), and 16% (p = 0.026) increased odds of monitored anesthesia care, respectively. Centers in the Northeast were more likely to use monitored anesthesia care (all p < 0.005). Patients who underwent approaches other than percutaneous femoral arterial were less likely to receive monitored anesthesia care (adjusted odds ratios all < 0.51; all p = 0.0001). Conclusion: Anesthetic type for transcatheter aortic valve replacements in the United States varies with age, sex, geography, volume of cases performed at a center, and procedural approach.

16.
Article | IMSEAR | ID: sea-219278

ABSTRACT

Thrombocytopenia is a common condition that recognizes an infinite number of possible causes, especially in specific settings like the one covered in this case report: the postoperative period of cardiac surgery. We report a case of an old male with multiple comorbidities who underwent a coronary angioplasty procedure and aortic valve replacement. He showed severe thrombocytopenia in the postoperative days. Differential diagnosis required a big effort, also for the experts in the field. Our goal was to aggressively treat the patient with prednisolone, platelets, and intravenous immunoglobulins to maximize the prognosis. Our patient developed no complications and was discharged successfully

17.
Article | IMSEAR | ID: sea-219275

ABSTRACT

Concomitant mitral and aortic valve stenosis in a patient with mitral annular calcification and porcelain aorta poses a unique problem to the surgical team. Transcatheter aortic and mitral valve replacements in native valves offer a viable option for such selected group of patients. We present the case of a 54-year-old male who presented with severe aortic stenosis (AS) and severe mitral stenosis (MS) but was deemed high risk for surgery owing to intense calcification of the aorta and mitral annular calcification, and successfully underwent transcatheter double native valve replacement.

18.
Article | IMSEAR | ID: sea-219274

ABSTRACT

Background: As visceral protein expression may influence outcomes in patients with cardiovascular disease, we investigated whether pre-procedural albumin concentration is associated with length of stay (LOS) and 90-day mortality after transcatheter aortic valve repair (TAVR). Methods: We retrospectively analyzed data from TAVR patients at our institution between January 2013 and December 2017. For all patients, baseline albumin concentration was assessed between one and four weeks before the procedure. To investigate the association between albumin concentration and outcomes, we performed regression analyses, controlling for Society of Thoracic Surgeons, New York Heart Association classification, and Kansas City Cardiomyopathy Questionnaire 12 scores. Results: Three hundred eighty patients were included in the analyses. Cox-proportional hazards regression showed that patients with albumin concentrations <3.5 g/dL were 80% more likely to have prolonged ICU LOS (HR 1.79; 95%CI 1.04�57, P = 0.03) and 70% more likely to have prolonged hospital LOS (HR 1.68; 95%CI 1.01?2.46, P = 0.04) compared to patients with albumin concentrations >3.5 g/dL. Logistic regression showed that patients with albumin concentrations <3.5 g/dL were four times more likely to not survive to 90 days (OR 3.94; 1.13�.63, P = 0.03) after their TAVR compared to patients with albumin concentrations >3.5 g/dL. Conclusion: Our data suggest that patients with pre?procedural albumin concentrations <3.5 g/dL are at an increased risk of adverse outcomes after TAVR compared to patients with albumin concentrations ?3.5 g/dL. Prospective studies are needed to determine whether risk stratification based on pre-procedural albumin can improve outcomes and whether targeted interventions can improve pre-procedural albumin concentrations in potential TAVR candidates.

19.
Indian Heart J ; 2023 Feb; 75(1): 59-67
Article | IMSEAR | ID: sea-220960

ABSTRACT

Objective: A recently published randomized control trial showed different results with suture-based vascular closure device (VCD) than plug-based VCD in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). The learning curve for MANTA device is steep, while the learning curve for suture based VCD is shallow as the devices are quite different. In this meta-analysis, we have compared suture-based (ProGlide and Prostar XL) vs plug-based VCDs (MANTA). Methods: We performed a meta-analysis of all published studies (using PubMed/Medline and Cochrane databases) reporting the clinical outcome of plug-based vs suture-based VCDs in transfemoral TAVR patients. Results: We included nine studies with a total of 2865 patients (plug-based n ¼ 1631, suture-based n ¼ 1234). There was no significant difference in primary outcome of all bleeding when using plugbased as opposed to suture-based VCDs (RR 1.14 [0.62e2.06] I2 ¼ 72%). There was no significant difference in the incidence of secondary outcomes between two groups including major life threatening bleeding (RR 1.16 [0.38e3.58] I2 ¼ 65%), major vascular complications (RR 0.84 [0.35e2.00] I2 ¼ 55%), minor vascular complications (RR 1.05 [0.56e1.95] I2 ¼ 42%), pseudo aneurysm (RR 1.84 [0.11e29.98] I 2 ¼ 44%), stenosis-dissection (RR 0.98 [0.66e1.47] I2 ¼ 0%), VCD failure (RR 1.71 [0.96e3.04] I2 ¼ 0%), and blood transfusion (RR 1.01 [0.38e2.71], I2 ¼ 61%). Conclusion: Large bore arteriotomy closure with plug-based VCD was not superior to suture-based VCDs in this transfemoral TAVR population. There was very frequent use of secondary VCDs in suture-based VCD group which is not practical when using MANTA. Additional high-powered studies are required to determine the safety and efficacy of MANTA device.

20.
Rev. bras. cir. cardiovasc ; 38(1): 37-42, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1423067

ABSTRACT

ABSTRACT Introduction: Bleeding after transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The predictive value of the HAS-BLED score in TAVR patients is still to be evaluated. We assessed the value of the HAS-BLED score to predict in-hospital bleeding and mortality after TAVR and the impact of diferent renal impairment definitions on the predictive value of the score system. Methods: We retrospectively included 574 patients who underwent TAVR at a single center. Study outcomes were 30-day mortality and the composite endpoint of major and life-threatening bleeding as defined by The Valve Academic Research Consortium-2. The predictive value of the HAS-BLED score was calculated and compared to a modified model. The performance of the score was compared using two definitions of renal impairment. Model discrimination was tested using C-statistic and the Net Reclassification Index. Results: Bleeding occurred in 78 patients (13.59%). HAS-BLED category 3 was a significant predictor of bleeding (OR: 1.99 ]1.18- 3.37], C-index: 0.56, P=0.01). C-index increased to 0.64 after adding body surface area and extracardiac arteriopathy to the model. The Net Reclassification Index showed an increase in the predic tive value of the model by 11.4% (P=0.002). The C-index increased to 0.61 using renal impairment definition based on creatinine clearance. Operative mortality was significantly associated with the HAS-BLED score (OR: 7.54 [95% CI: 2.73- 20.82], C-index: 0.73, P<0.001). Conclusion: The HAS-BLED score could be a good predictor of in-hospital mortality after TAVR. Its predictive value for bleeding was poor but improved by adding procedure-specific factors and using creatinine clearance to define renal impairment.

SELECTION OF CITATIONS
SEARCH DETAIL