Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Korean Journal of Radiology ; : 550-559, 2015.
Article in English | WPRIM | ID: wpr-83671

ABSTRACT

Balanced steady-state free precession (bSSFP) is a highly efficient pulse sequence that is known to provide the highest signal-to-noise ratio per unit time. Recently, bSSFP is getting increasingly popular in both the research and clinical communities. This review will be focusing on the application of the bSSFP technique in the context of probing the physiological and functional information. In the first part of this review, the basic principles of bSSFP are briefly covered. Afterwards, recent developments related to the application of bSSFP, in terms of physiological and functional imaging, are introduced and reviewed. Despite its long development history, bSSFP is still a promising technique that has many potential benefits for obtaining high-resolution physiological and functional images.


Subject(s)
Humans , Cervical Vertebrae/blood supply , Head/blood supply , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Signal-To-Noise Ratio
2.
Korean Journal of Radiology ; : 554-558, 2011.
Article in English | WPRIM | ID: wpr-121841

ABSTRACT

OBJECTIVE: Brain perfusion can be assessed non-invasively by modern arterial spin labeling MRI. The FAIR (flow-sensitive alternating inversion recovery)-TrueFISP (true fast imaging in steady precession) technique was applied for regional assessment of cerebral blood flow in brain areas close to the skull base, since this approach provides low sensitivity to magnetic susceptibility effects. The investigation of the rhinal cortex and the amygdala is a potentially important feature for the diagnosis and research on dementia in its early stages. MATERIALS AND METHODS: Twenty-three subjects with no structural or psychological impairment were investigated. FAIR-True-FISP quantitative perfusion data were evaluated in the amygdala on both sides and in the pons. A preparation of the radiofrequency FOCI (frequency offset corrected inversion) pulse was used for slice selective inversion. After a time delay of 1.2 sec, data acquisition began. Imaging slice thickness was 5 mm and inversion slab thickness for slice selective inversion was 12.5 mm. Image matrix size for perfusion images was 64 x 64 with a field of view of 256 x 256 mm, resulting in a spatial resolution of 4 x 4 x 5 mm. Repetition time was 4.8 ms; echo time was 2.4 ms. Acquisition time for the 50 sets of FAIR images was 6:56 min. Data were compared with perfusion data from the literature. RESULTS: Perfusion values in the right amygdala, left amygdala and pons were 65.2 (+/- 18.2) mL/100 g/minute, 64.6 (+/- 21.0) mL/100 g/minute, and 74.4 (+/- 19.3) mL/100 g/minute, respectively. These values were higher than formerly published data using continuous arterial spin labeling but similar to 15O-PET (oxygen-15 positron emission tomography) data. CONCLUSION: The FAIR-TrueFISP approach is feasible for the quantitative assessment of perfusion in the amygdala. Data are comparable with formerly published data from the literature. The applied technique provided excellent image quality, even for brain regions located at the skull base in the vicinity of marked susceptibility steps.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Amygdala/blood supply , Cerebrovascular Circulation , Dementia/diagnosis , Entorhinal Cortex/blood supply , Image Processing, Computer-Assisted , Magnetic Resonance Imaging/methods , Pons/blood supply , Reproducibility of Results , Spin Labels