Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Dental press j. orthod. (Impr.) ; 24(5): 46-51, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1039668

ABSTRACT

ABSTRACT Introduction: Anchorage conservation in orthodontics has always been a challenge. Objective: The aim of this current study was to find out the failure rate of miniscrews inserted in the maxillary tuberosity (MT) region. Methods: This pilot study consisted of 40 patients (23 female, 17 male; mean age = 20.1±8.9 years) that had received 60 MT miniscrews for orthodontic treatment. Clinical notes and pictures were used to find out the primary outcome of miniscrew failure. Independent failure factors were also investigated. Logistic regression analysis was done for predictor's relation with MT miniscrews failure. Results: There was no significant correlation in failure rate according to various predictor variables, except for miniscrews installed by lesser experienced operators, which showed significantly more failure. The odds ratio for miniscrew failure placed by inexperienced operators was 4.16. Conclusion: A 26.3% failure rate of mini-implants inserted in the MT region was observed.


RESUMO Introdução: a manutenção da ancoragem sempre foi um desafio na Ortodontia. Objetivo: o objetivo do presente estudo foi descobrir a taxa de falhas dos mini-implantes instalados na região da tuberosidade maxilar (TM). Métodos: o presente estudo piloto avaliou 40 pacientes (23 mulheres, 17 homens; idade média = 20,1 ± 8,9 anos) que receberam 60 mini-implantes na TM durante o tratamento ortodôntico. Anotações clínicas e fotografias foram usadas para investigar o principal motivo para a falha do mini-implante. Fatores de insucesso independentes também foram investigados. Uma análise de regressão logística foi realizada para medir o impacto de cada fator preditivo sobre a falha na instalação dos mini-implantes na TM. Resultados: as diferentes variáveis preditivas não demonstraram correlação significativa com a taxa de falhas, com exceção da instalação dos mini-implantes realizada por operadores inexperientes, que mostrou quantidade significativamente maior de falhas. A razão de chances para a falha dos mini-implantes instalados por operadores inexperientes foi de 4,16. Conclusão: observou-se uma taxa de falhas de 26,3% para os mini-implantes instalados na região da TM.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Young Adult , Orthodontics , Orthodontic Anchorage Procedures , Bone Screws , Pilot Projects , Maxilla
2.
Pesqui. vet. bras ; 38(12): 2246-2253, dez. 2018. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-976424

ABSTRACT

Cranial cruciate ligament is the main responsible for knee stability by preventing cranial tibial displacement regarding the femur. Deficiency in this ligament (CCLD) may cause subluxation of the tibia and dysfunction of the pelvic member due to overloading. Tibial osteotomies are among the more current surgical techniques for treating CCLD in dogs and they proportionate the dynamic stability by means of modifying bone geometry and the distribution of forces acting on the articulation. The objective of this work is to describe the use of the allogeneic cortical bone graft conserved in glycerin as a spacer on the tibial tuberosity advancement (TTA) for treating the CCLD. In order to do that, 34 dogs submitted to TTA surgery correction were evaluated, being 23 males (67.35%) and 11 females (32.35%). Surgical procedures happened from May 2011 to October 2015. Regarding the surgical procedure after osteotomy of the tibial tuberosity, a disk of allogeneic cortical disk, sawn wedge-hapsed, conserved in glycerin, proportions of 2x1mm was applied as spacer, enabling TTA. Advancements from 3 to 12 mm were executed, depending on the need of the patient. For animals with patella dislocation, trochleoplasty and TTA were executed in order to correct the deviation. The mean ± SD age of animals was 6.67±3.58 and weight was 15.16±12.97 kg. Mongrel dogs, Poodles and Yorkshire terriers were the most affected ones. From the 36 evaluated knees, 11 (30.56%) were associated with some traumatic process and in 25 (69.44%) there was no relation with previous trauma. From those wounds, 20 (55.56%) happened in the right limb and 16 (44.44%) in the left limb and two animals had CCLD bilaterally. Animals had continuous support, discreet drawer movement and negative tibial compression 15 days after surgery. At 30 days, 26 cases (72.22%) had firm support (FS); at 45 days, 24 cases (66 test at 7 and 67%) had FS and eight cases (22.22%) without claudication (WC). During subsequent radiographic evaluations the progressive incorporation of the graft and osteotomy union were observed. In this study, most of the diagnosed CCLD occurred in males diverging from results obtained by other authors that found greater frequency in females. Support without claudication it was observed in most of the cases of implants at 60 days. We concluded that the conserved allogeneic cortical bone graft was able to promote bone union in TTA of dogs with CCLD. None of the animals had signs of contamination, infection of the surgical wound or rejection related with the presence of the graft, demonstrated by the complete graft-bone incorporation observed early at 45 days in some animals. The glycerin was a good conservation medium for those fragments intended for grafting because, besides being of low cost, it kept bone fragments free of contamination, reducing antigenicity and preserving the functions of osteoinduction and osteoconduction. The possibility of molding the graft to the animal need is a characteristic favorable to executing the modified technique that could be molded according to the size of the animal, allowing perfect adaptation to the osteotomized local in different breeds. Intercurrences commonly observed in TTA with patellar dislocation, meniscal lesions, tibial crest fracture and displacement were not found in the animals of this study, probably due to the better distribution of forces between the pass screw in TT and the TTA plate confirming that it has good adaptation to the technique conferring to the modified TTA advantages regarding the conventional TTA.(AU)


O ligamento cruzado cranial é o principal responsável pela estabilidade do joelho, impedindo o deslocamento da tíbia cranial em relação ao fêmur. A deficiência neste ligamento (CCLD) pode causar subluxação da tíbia e disfunção do membro pélvico devido à sobrecarga. As osteotomias tibiais estão entre as técnicas cirúrgicas mais atuais para o tratamento de CCLD em cães e proporcionam a estabilidade dinâmica por meio da modificação da geometria óssea da distribuição das forças que atuam sobre a articulação. O objetivo desse estudo é descrever o uso do enxerto ósseo cortical alogênico conservado em glicerina como espaçador no avanço da tuberosidade tibial (TTA) para o tratamento do CCLD. Para isso, 34 cães submetidos à cirurgia de TTA foram avaliados, sendo 23 machos (67,35%) e 11 fêmeas (32,35%). Os procedimentos curúrgicos aconteceram entre maio de 2011 e outubro de 2015. Com relação ao procedimento cirúrgico após a osteotomia da tuberosidade tibial, um disco alogênico cortical, em forma de cunha serrada, conservado em glicerina com proporções de 2 x 1mm foi aplicado como espaçador possibilitando a TTA. Avanços de 3 a 12mm foram executados, dependendo da necessidade do paciente. Para animais com luxação da patela, realizou-se a trocleoplastia e a TTA para a correção do desvio. A idade média dos animais foi de 6,67±3,58 anos e pesos médios de 15,16±12,97kg. Cães sem raça definida, Poodles e Yorkshire Terriers foram os mais afetados. Dos 36 joelhos avaliados, 11 (30,56%) foram associados a algum processo traumático e em 25 (69,44%) não havia nenhuma relação com um trauma prévio. Dos ferimentos, 20 (55,56%) aconteceram no membro direito e 16 (44,44%) no esquerdo, sendo que dois animais apresentavam CCLD bilateralmente. Os animais tiveram suporte contínuo, discreto movimento de gaveta e compressão tibial negativa 15 dias após a cirurgia. Aos 30 dias, 26 casos tinham suporte firme (FS); aos 45 dias, 24 casos tinham FS e oito casos sem claudicação (WC). Durante avaliações radiográficas subsequentes, observou-se a incorporação progressiva da união do enxerto e da osteotomia. Neste estudo, a maior parte do CCLD diagnosticado ocorreu em machos, divergindo dos resultados obtidos por outros autores que encontraram maior frequência em fêmeas. Suporte sem claudicação foi observado na maioria dos casos de implantes aos 60 dias. Foi concluído que o enxerto ósseo cortical alogênico conservado foi capaz de promover a união óssea na TTA de cães com CCLD. Nenhum dos animais apresentou sinais de contaminação, infecção da ferida cirúrgica ou rejeição relacionada à presença do enxerto, demonstrada pela incorporação completa do enxerto ósseo observada precocemente aos 45 dias em alguns animais. A glicerina foi um bom meio de conservação para os fragmentos destinados à enxertia porque, além do menor custo, manteve os fragmentos ósseos livres de contaminação, reduzindo a antigenicidade e preservando as funções de osteoindução e osteocondução. A possibilidade de moldagem do enxerto à necessidade do animal é uma característica favorável à execução da técnica modificada que pode ser moldada de acordo com o tamanho do animal, possibilitando perfeita adaptação ao local osteotomizado em diferentes raças. Intercorrências comumente observadas na TTA com luxação patelar, lesões meniscais, fratura da crista tibial e deslocamento não foram encontradas nos animais deste estudo, provavelmente devido à melhor distribuição de forças entre a passagem do parafuso no TT e a placa do TTA, confirmando que tem boa adaptação à técnica conferindo às vantagens da TTA modificada em relação à TTA convencional.(AU)


Subject(s)
Animals , Dogs , Stifle/surgery , Stifle/physiopathology , Stifle/injuries , Bone Transplantation/methods , Bone Transplantation/veterinary , Glycerol/pharmacology
3.
Full dent. sci ; 2(6): 138-142, 20110816.
Article in Portuguese | LILACS, BBO | ID: biblio-850827

ABSTRACT

A exodontia de terceiros molares superiores consiste num procedimento cirúrgico que requer, além de destreza manual do cirurgião, um conhecimento básico acerca dos acidentes e/ou complicações decorrente da remoção desses elementos dentais. Neste trabalho os autores realizaram uma breve revisão de literatura acerca das fraturas da tuberosidade maxilar, relatando um caso clínico de fratura tuberositária decorrente da extração de um terceiro molar superior em um paciente atendido na clínica odontológica do CESUPA, Belém/PA, tratado através de redução cruenta e Fixação Interna Rígida (FIR) dos fragmentos. Os autores realizaram ainda uma discussão sobre as abordagens terapêuticas mais apropriadas para tal complicação, que preconizam a manutenção do fragmento e sua estabilização. O tratamento cirúrgico empregado no caso clínico supracitado foi a redução e fixação interna rígida com placas e parafusos de titânio sistema 1.5mm, que permitiu a conservação do bloco ósseo fraturado levando em consideração a necessidade de uma futura reabilitação protética estável


The objective was to report a case of fracture of the maxillary tuberosity after attempted extraction of the third right upper molar. The patient for the case studieds was a male, X years who attended the emergency sector of the Dental Clinic CESUPA, Belém / PA referred to by another professional who, in an attempt to remove the 3rd molar (18), resulted in a fractured of the maxillary tuberosity. The conduct was based on the bloody reduction and rigid internal fixation of the fragment. As a conclusion it can be said that the conservative treatment with titanium plate and screws 1.5mm system is the most accepted therapeutic measure due regard to the possibility of future rehabilitation prosthesis stable


Subject(s)
Humans , Male , Adult , Surgery, Oral/instrumentation , Maxillary Fractures/complications , Molar, Third , Osteotomy/instrumentation , Titanium/chemistry , Radiography, Dental/methods
4.
Ciênc. rural ; 39(2): 467-472, mar.-abr. 2009. ilus
Article in English | LILACS | ID: lil-508107

ABSTRACT

The present study aimed to evaluate a modification of the stabilization method of the tibial tuberosity advancement technique (TTA), originally described for stabilization of the cranial cruciate deficient stifle. Ten adult mongrel dogs with weights ranging from 25 to 30kg were used. After euthanasia, the hind-limbs were divided into two groups: G1 - test (n=10), and G2 - control (n=10) represented by the contra lateral limb. The test group was submitted to the modified TTA technique, stabilized by one shaft screw in craniocaudal position and a titanium cage inserted at the osteotomy site. The position of the patellar tendon, 90º in relation to the tibial plateau, and the correct position of all implants were confirmed radiographically after surgery. Posteriorly, in both groups, limbs were harvested and tibias collected with their respectively patellar tendon insertion preserved for the mechanical resistance test. The fixation of the tibial tuberosity with a shaft screw and titanium cage resulted in resistance compatible with the normal physiological forces transferred to the hind-limbs during locomotion. The biomechanical tests confirmed the viability of the method performed for the tibial tuberosity fixation and support future clinical trials to validate the technique.


O presente estudo teve por objetivo avaliar a resistência mecânica do método de estabilização da técnica de avanço da tuberosidade tibial (TTA), originalmente descrita para tratamento da ruptura do ligamento cruzado cranial. Foram avaliados 10 cães, sem raça definida e com massa corporal entre 25 e 30kg. Após a eutanásia, os membros pélvicos foram divididos em dois grupos, sendo que G1 era o grupo teste (n=10) e G2 o controle (n=10), representado pelo membro contralateral. O grupo operado foi submetido à técnica de avanço da tuberosidade tibial (TTA) modificada, com emprego de um parafuso especial em posição craniocaudal e um espaçador de titânio inserido no local de osteotomia. O posicionamento do tendão patelar perpendicularmente ao platô tibial e o correto posicionamento dos implantes foi confirmado radiograficamente em todos os espécimes. Posteriormente, em ambos os grupos foram coletadas as tíbias, com preservação da inserção dos seus respectivos tendões patelares, para realização dos testes de resistência mecânica. A estabilização da tuberosidade tibial por parafuso especial em sentido craniocaudal e espaçador de titânio demonstrou resistência compatível com as forças fisiológicas tradicionalmente impostas ao membro pélvico durante a locomoção. Os testes biomecânicos confirmam a viabilidade do método de estabilização e sustentam estudos clínicos futuros para validação da técnica cirúrgica.


Subject(s)
Animals , Dogs , Dogs/injuries , Osteotomy/methods , Osteotomy/veterinary , Bone Screws , Bone Screws/veterinary , Tibia/injuries , Titanium/therapeutic use , Biomechanical Phenomena
5.
Ciênc. rural ; 39(2): 473-478, mar.-abr. 2009. ilus
Article in English | LILACS | ID: lil-508116

ABSTRACT

The present study aimed to determine biomechanical alterations resultant from a modification in the fixation method of the tibial tuberosity advancement technique (TTA), originally described for stabilization of the cranial cruciate-deficient stifle. Ten adult mongrel dogs weighing 25-30kg were used. After euthanasia, performed for reasons unrelated to this study, the hind limbs were distributed into two groups: G1 operated (n=10) and G2 control (n=10), represented by the contralateral limb. The operated hind limbs were orthopedically, goniometrically and radiographically evaluated, sequentially at four moments: moment 1, in intact joints; moment 2, after cranial cruciate desmotomy; moment 3, after surgical stabilization of the stifle joint using modified TTA; and moment 4, after caudal cruciate ligament desmotomy. The tibial tuberosity was stabilized by one shaft screw craniocaudally and a titanium cage inserted at the osteotomy site. The position of the patellar tendon at 90º in relation to the tibial plateau allowed cranial tibial thrust force neutralization, despite cranial drawer motion maintenance in all dogs. The biomechanical tests confirm the viability of the tibial tuberosity fixation method and support future clinical trials to validate the technique.


O presente estudo teve como objetivo determinar as alterações biomecânicas decorrentes da modificação da técnica de avanço da tuberosidade tibial (TTA), originalmente descrita para estabilização da ruptura do ligamento cruzado cranial. Foram avaliados 10 cães, sem raça definida e com peso entre 25 e 30kg, submetidos à eutanásia por razões independentes do presente estudo. Os membros pélvicos foram distribuídos em dois grupos: G1 operado (n=10) e G2 controle (n=10), representado pelo membro contralateral. Os membros operados foram submetidos à avaliação ortopédica, goniométrica e radiográfica nos momentos 1 (articulação intacta), 2 (após desmotomia do cruzado cranial), 3 (após estabilização articular pela TTA modificada) e 4 (após a desmotomia do cruzado caudal). A tuberosidade tibial foi estabilizada por um parafuso cortical em posicionamento craniocaudal e um espaçador de titânio inserido no local de osteotomia. A posição do tendão patelar perpendicular em relação ao platô tibial promoveu a neutralização da força de cisalhamento tibial cranial, apesar da permanência do movimento de gaveta cranial em todos os joelhos. Os testes biomecânicos confirmam a viabilidade do método empregado para estabilização da tuberosidade tibial e sustentam a realização de estudos clínicos futuros para validação da técnica.


Subject(s)
Animals , Dogs , Dogs/injuries , Osteotomy/methods , Osteotomy/veterinary , Bone Screws , Bone Screws/veterinary , Tibia/injuries , Titanium/therapeutic use , Biomechanical Phenomena
6.
ImplantNews ; 6(5): 551-558, 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-544259

ABSTRACT

Este artigo descreve o procedimento de restauração imediata pós-exodontia em alvéolo comprometido na região do incisivo central superior. Foi realizada a instalação de um implante associada ao enxerto de lâmina óssea da tuberosidade da maxila para a recuperação do defeito ósseo. O posicionamento adequado do implante, a inserção da lâmina óssea no defeito alveolar até o nível da plataforma do implante, a plataforma switching e o perfil de emergência da coroa provisória, promovendo um espaço para permitir a acomodação do tecido mole, foram os critérios utilizados que permitiram o sucesso deste caso clínico. Este procedimento promoveu a recuperação da estrutura anatômica dentoalveolar perdida em um único procedimento, sem retalho, com a manutenção do contorno da margem gengival e estética satisfatória.


This paper describes the procedure of immediate restoration in a compromised fresh extraction socket in the region of upper central incisors. An implant was inserted, together with a bone sliver graft from the maxillary tuberosity, in order to restore the bone defect. The criteria that enabled success in this clinical case were the adequacy of implant positioning; the insertion of a bone sliver into the socket defect, to the level of the implant platform; the platform switching; and the emergence profile of the provisional crown, which promoted space for the soft tissue to be accommodated. This procedure promoted recovery of the lost dentoalveolar anatomical structure in a single procedure, without a flap, while maintaining the gingival profile and satisfactory esthetics.


Subject(s)
Humans , Female , Adult , Bone Transplantation , Surgery, Oral , Tooth Socket , Transplantation
SELECTION OF CITATIONS
SEARCH DETAIL