Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Radiation Oncology Journal ; : 232-248, 2019.
Article | WPRIM | ID: wpr-786567

ABSTRACT

Proton beams have been used for cancer treatment for more than 28 years, and several technological advancements have been made to achieve improved clinical outcomes by delivering more accurate and conformal doses to the target cancer cells while minimizing the dose to normal tissues. The state-of-the-art intensity modulated proton therapy is now prevailing as a major treatment technique in proton facilities worldwide, but still faces many challenges in being applied to the lung. Thus, in this article, the current status of proton therapy technique is reviewed and issues regarding the relevant uncertainty in proton therapy in the lung are summarized.


Subject(s)
Lung Neoplasms , Lung , Proton Therapy , Protons , Uncertainty
2.
Journal of Korean Medical Science ; : e107-2018.
Article in English | WPRIM | ID: wpr-714282

ABSTRACT

BACKGROUND: To analyze clinical outcome of CyberKnife (CK) tumor-tracking stereotactic body radiotherapy (SBRT) for prostate cancer (Pca) according to the magnitude of intra-fractional prostate motion. METHODS: Medical records and daily treatment logs for 71 patients who received CK tumor-tracking SBRT were retrospectively analyzed. Statistical relationships between prostate motion and various outcome results, including local recurrence (LR), biochemical failure (BF), and treatment-related toxicity, were investigated in order to evaluate motion-dependent efficacy of tumor-tracking SBRT for Pca. RESULTS: In a total 71 patients, 3 (4.2%) patients with LR, 12 (16.9%) patients with BF, and 22 (31%) patients with grade-II or worse toxicities to rectal or bladder (22 to rectal, 22 to bladder and 8 patients to both) were observed in a median follow-up of 47 months. Magnitudes of intra-fractional tumor motion along superior-inferior, right-left, and anterior-posterior (AP) axes were 0.15 ± 0.31, 0.12 ± 0.19, and 0.73 ± 0.32 mm, respectively. Radial magnitude was estimated to be 1.0 ± 0.35 mm. Intra-fractional movement was not significantly correlated with tumor control. However, it was significant correlated with the incidence of grade-II or worse toxicity to rectum or bladder particularly when tumor motion was in the AP axis. CONCLUSION: Our quantitative results revealed that toxicity related to SBRT treatment was highly sensitive to intra-fractional prostate movements, although local-tumor control was not affected by such movements. Our results demonstrate that precise motion correction is essential in prostate SBRT, even if it seems to be small.


Subject(s)
Humans , Follow-Up Studies , Incidence , Medical Records , Passive Cutaneous Anaphylaxis , Prostate , Prostatic Neoplasms , Radiosurgery , Rectum , Recurrence , Retrospective Studies , Urinary Bladder
3.
Korean Journal of Medical Physics ; : 107-116, 2011.
Article in Korean | WPRIM | ID: wpr-99723

ABSTRACT

Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.


Subject(s)
Humans , Respiration , Statistics as Topic
4.
Korean Journal of Medical Physics ; : 14-20, 2008.
Article in Korean | WPRIM | ID: wpr-203480

ABSTRACT

Accounting for tumor motion in treatment planning and delivery is one of the most recent and significant challenges facing radiotherapy. The purpose of this study was to investigate the correlation and clarified the relationship between the motion of an external marker using the Real?Time Position Management (RPM) System and an internal organ motion signal obtained fluoroscope. We enrolled 10 patients with locally advanced lung cancer and liver cancer, retrospectively. The external marker was a plastic box, which is part of the RPM used to track the patient's respiration. We investigated the quantitatively correlation between the motions of an external marker with RPM and internal motion with fluoroscope. The internal fiducial motion is predominant in the caraniocaudal direction, with a range of 1.3~3.5 cm with fluoroscopic unit. The external fiducial motion is predominant in the caraniocaudal direction, with a range of 0.43~2.19 cm with RPM gating. The two measurements ratio is from 1.31 to 5.56. When the regularization guided standard deviation is from 0.08 to 0.87, mean 0.204 cm, except only for patients #3 separated by a mean 0.13 cm, maximum of 0.23 cm. This result is a good correlation between internal tumor motion imaged by fluoroscopic unit and external marker motion with RPM during expiration within 0.23 cm. We have demonstrated that gating may be best performed but special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct phase difference alone would not guarantee that the entire tumor volume is within the treatment field.


Subject(s)
Humans , Accounting , Liver Neoplasms , Lung Neoplasms , Plastics , Respiration , Retrospective Studies , Skin , Track and Field , Tumor Burden
SELECTION OF CITATIONS
SEARCH DETAIL