Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Arq. bras. oftalmol ; 86(5): e20230065, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527804

ABSTRACT

ABSTRACT Purpose: The study aimed to investigate the correlation between arterial hemodynamics measured by color Doppler ultrasonography and retinal microarchitecture parameters determined by spectral-domain optical coherence tomography (SD-OCT) in pseudoexfoliation glaucoma. Methods: This prospective study included 82 participants. Peripapillary retinal nerve fiber layer, ganglion cell inner plexiform layer, and ganglion cell complex values were measured. Ophthalmic artery and central retinal artery flows were evaluated with color Doppler ultrasonography, and resistivity index values were calculated. Results: The study included 47 controls and 35 pseudoexfoliation glaucoma cases. In pseudoexfoliation glaucoma group, mean peripapillary retinal nerve fiber layer and ganglion cell complex thickness were statistically significantly lower in all quadrants compared to controls (p<0.001). Resistivity index values of the ophthalmic and central retinal arteries were significantly higher in pseudoexfoliation glaucoma group than in the controls (p<0.001 and r=0.684). Resistivity index values of the ophthalmic and central retinal arteries with ganglion cell complex thickness correlated significantly. On the other hand, no significant relationship for retinal nerve fiber layer thickness was identified. Conclusions: Structural changes (ganglion cell complex and ganglion cell inner plexiform layer) in patients with pseudoexfoliation glaucoma and early glaucomatous loss showed a significant correlation with changes in ocular vascular hemodynamics. In cases where systemic vascular resistance is increased, ganglion cell complex and ganglion cell inner plexiform layer may not exactly reflect glaucoma state. In such cases, thickness changes in the retinal nerve fiber layer may give more realistic results regarding glaucoma. We have seen that pseudoexfoliation glaucoma-induced structural deterioration and increased resistance in ocular hemodynamics correlated with ganglion cell complex, but not retinal nerve fiber layer.


RESUMO Objetivo: Investigar a correlação entre a hemodi­nâmica arterial, medida pela ultrassonografia com Doppler colorido, e os parâmetros de microarquitetura da retina, determinados pela tomografia de coerência óptica de domínio espectral (SD-OCT) no glaucoma pseudoexfoliativo. Métodos: Foram incluídos 82 participantes neste estudo prospectivo. Foram medidos os valores da camada de fibras nervosas da retina peripapilar, da camada plexiforme interna de células ganglionares e do complexo de células ganglionares. Os fluxos da artéria oftálmica e da artéria central da retina foram avaliados com ultrassonografia por Doppler colorida e foram calculados os valores do índice de resistividade. Resultados: Foram incluídos no estudo 47 casos de controle e 35 casos de glaucoma pseudoexfoliativo. No grupo com glaucoma pseudoexfoliativo, a média da camada de fibras nervosas da retina peripapilar e a espessura do complexo de células ganglionares foram menores em todos os quadrantes em comparação com os controles, com significância estatística (p<0,001). Os valores do índice de resistividade das artérias oftálmica e central da retina foram significativamente maiores no grupo com glaucoma pseudoexfoliativo que nos controles (p<0,001 e r=0,684). Ao se compararem os valores do índice de resistividade das artérias oftálmica e central da retina com a espessura do complexo de células ganglionares, foi encontrada uma correlação significativa entre elas. Por outro lado, não detectamos uma relação significativa para a espessura da camada de fibras nervosas da retina. Conclusões: Alterações estruturais (complexo de células ganglionares, camada plexiforme interna de células ganglionares) em pacientes com glaucoma pseudoexfoliativo com perda glaucomatosa precoce mostraram uma correlação significativa com alterações na hemodinâmica vascular ocular. Nos casos em que a resistência vascular sistêmica é aumentada, o complexo de células ganglionares e a camada plexiforme interna de células ganglionares podem não refletir exatamente o estado do glaucoma. Nesses casos, alterações na espessura da camada de fibras nervosas da retina podem dar resultados mais realistas em relação ao glaucoma. Observou-se uma correlação da deterioração estrutural induzida pelo glaucoma pseudoexfoliativo e do aumento da resistência na hemodinâmica ocular com o complexo de células ganglionares, mas não com a camada de fibras nervosas da retina.

2.
Arq. bras. oftalmol ; 83(5): 417-423, Sept.-Oct. 2020. tab, graf
Article in English | LILACS | ID: biblio-1131620

ABSTRACT

ABSTRACT Purposes: To evaluate changes in ocular blood flow and subfoveal choroidal thickness in patients with symptomatic carotid artery stenosis after carotid artery stenting. Methods: We included 15 men (mean age, 63.6 ± 9.1 years) with symptomatic carotid artery stenosis and 18 healthy volunteers (all men; mean age, 63.7 ± 5.3 years). All participants underwent detailed ophthalmologic examinations including choroidal thickness measurement using enhanced depth-imaging optic coherence tomography. The patients also underwent posterior ciliary artery blood flow measurements using color Doppler ultrasonography before and after carotid artery stenting. Results: Patients lacked ocular ischemic symptoms. Their peak systolic and end-diastolic velocities increased to 10.1 ± 13.1 (p=0.005) and 3.9 ± 6.3 (p=0.064) cm/s, respectively, after the procedure. Subfoveal choroidal thicknesses were significantly thinner in patients with carotid artery stenosis than those in the healthy controls (p=0.01). But during the first week post-procedure, the subfoveal choroidal thicknesses increased significantly (p=0.04). The peak systolic velocities of the posterior ciliary arteries increased significantly after carotid artery stenting (p=0.005). We found a significant negative correlation between the mean increase in peak systolic velocity values after treatment and the mean preprocedural subfoveal choroidal thickness in the study group (p=0.025, r=-0.617). Conclusions: In patients with carotid artery stenosis, the subfoveal choroid is thinner than that in healthy controls. The subfoveal choroidal thickness increases after carotid artery stenting. Carotid artery stenting treatment increases the blood flow to the posterior ciliary artery, and the preprocedural subfoveal choroidal thickness may be a good predictor of the postprocedural peak systolic velocity of the posterior ciliary artery.


RESUMO Objetivos: Avaliar alterações no fluxo sanguíneo ocular e na espessura da coroide subfoveal em pacientes com estenose sintomática da artéria carótida, após implante de stent nessa artéria. Métodos: Foram incluídos 15 homens (idade média de 63,6 ± 9,1 anos) com estenose sintomática da artéria carótida e 18 voluntários saudáveis (todos homens; idade média de 63,7 ± 5,3 anos). Todos os participantes foram submetidos a exames oftalmológicos detalhados, incluindo d medição da espessura da coroide, usando tomografia de coerência óptica com imagem de profundidade aprimorada. Os pacientes também foram submetidos a medidas do fluxo sanguíneo das artérias ciliares posteriores, usando ultrassonografia com Doppler colorido, antes e após o implante do stent na artéria carótida. Resultados: Os pacientes não apresentaram sintomas isquêmicos oculares. O pico de velocidade sistólica e diastólica final aumentou para 10,1 ± 13,1 (p=0,005) e 3,9 ± 6,3 (p=0,064) cm/s, respectivamente, após o procedimento. As espessuras da coroide subfoveais foram significativamente mais finas nos pacientes com estenose da artéria carótida do que nos controles saudáveis (p=0,01). Porém, durante a primeira semana pós-procedimento, as espessuras das coroides subfoveais aumentaram significativamente (p=0,04). O pico de velocidade sistólica das artérias ciliares posteriores aumentou significativamente após o stent na artéria carótida (p=0,005). Encontramos uma correlação negativa significativa entre o aumento médio dos valores máximos de velocidade sistólica após o tratamento e a espessura da coroide subfoveal pré-procedimento média no grupo de estudo (p=0,025, r=-0,617). Conclusões: Em pacientes com estenose da artéria carótida, a coroide subfoveal é mais fina que a dos controles saudáveis. A espessura da coroide subfoveal aumenta após o stent na artéria carótida. O tratamento com stent na artéria carótida aumenta o fluxo sanguíneo para a artéria ciliar posterior, e a espessura coroidal subfoveal pré-procedimento pode ser um bom preditor da velocidade sistólica de pico pós-procedimento da artéria ciliar posterior.


Subject(s)
Humans , Male , Middle Aged , Aged , Ophthalmic Artery , Blood Flow Velocity , Carotid Arteries , Choroid , Regional Blood Flow , Stents , Choroid/anatomy & histology , Choroid/diagnostic imaging , Carotid Stenosis/surgery , Carotid Stenosis/diagnostic imaging , Tomography, Optical Coherence
3.
Radiol. bras ; 51(4): 257-261, July-Aug. 2018. graf
Article in English | LILACS | ID: biblio-956280

ABSTRACT

Abstract Ultrasound is an excellent method for the study of penis. In this article, using a critical review of the literature and teaching files, we present examples of the major findings in the ultrasound routine, focusing on trauma, priapism, Peyronie's disease, and erectile dysfunction.


Resumo A ultrassonografia é um excelente método para a avaliação peniana. Neste artigo, com base em uma análise crítica da literatura e arquivos didáticos, apresentamos exemplos das principais alterações encontradas na rotina ultrassonográfica, destacando-se o traumatismo, o priapismo, a doença de Peyronie e a disfunção erétil.

4.
Arq. bras. oftalmol ; 80(3): 143-147, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-888111

ABSTRACT

ABSTRACT Purpose: To evaluate intraocular pressure (IOP) and extraocular orbital vessels with color Doppler ultrasound (CDU) and investigate the effects of obesity on retrobulbar blood flow. Methods: Fifty-nine patients were included in this prospective study. Patients were divided into two groups according to body mass index: Group 1 (31 obese patients) and Group 2 (28 non-obese patients). IOP was measured with a Goldmann applanation tonometer, and CDU was used to evaluate the retrobulbar vessels. Results: The mean IOP was 18 ± 6.68 mmHg in the obese group and 13.71 ± 1.60 mmHg in the control group (p<0.001). When the CDU values for the central retinal artery were compared between the groups, the pulsatility index was found to be significantly lower in the obese group than in the control group (p<0.001). When the CDU values for the ophthalmic artery (OA) were compared between the groups, the peak systolic velocity (p<0.001) and end-diastolic velocity (p=0.002) values were found to be significantly lower in the obese group than in the control group. Conclusions: Obese patients have a higher mean IOP and lower flow velocity than non-obese patients. Increased IOP together with decreased retrobulbar blood flow, particularly in obese individuals, may increase the risk of glaucoma development.


RESUMO Objetivo: Avaliar a pressão intraocular (PIO) e vasos orbitários extraoculares com ultrassom Doppler colorido (UDC) e investigar os efeitos da obesidade sobre o fluxo sanguíneo retrobulbar. Métodos: Cinquenta e nove pacientes foram incluídos neste estudo prospectivo. Os pacientes foram divididos em dois grupos de acordo com o índice de massa corpo ral (IMC): Grupo 1 (31 pacientes obesos) e Grupo 2 (28 não obesos). As pressões intraoculares (PIOs) foram medidas com tonômetro de aplanação de Goldmann e o UDC foi utilizada para a avaliação de vasos retrobulbar. Resultados: As PIOs foram 18 ± 6,68 mmHg nos pacientes obesos e 13,71 ± 1,60 mmHg nos grupos controle (p<00,001). Quando os valores da artéria central da retina (ACR) foram comparados entre os grupos controle e obeso. O índice pulsátil (PI) foi marcadamente menor no grupo obeso (p<00,001). Quando os valores da artéria oftálmica (AO) dos grupos obesos e de controle foram comparados. Os valores de Velocidade do pico sistólico (PSV) (p<00,001) e velocidade diastólica final (EDV) (p=00,002) foram significativamente mais baixos no grupo obeso. Conclusão: Pacientes obesos têm maior PIO do que os pacientes não obesos. Os pacientes obesos têm diminuição nas velocidades de fluxo da AO. O aumento da PIO. Juntamente com a diminuição do fluxo sanguíneo retrobulbar, especialmente em indivíduos obesos, pode aumentar o risco de desenvolvimento de glaucoma.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Ophthalmic Artery/physiopathology , Regional Blood Flow/physiology , Retinal Artery/physiopathology , Intraocular Pressure/physiology , Obesity/physiopathology , Ophthalmic Artery/diagnostic imaging , Reference Values , Retinal Artery/diagnostic imaging , Tonometry, Ocular , Body Mass Index , Case-Control Studies , Sex Factors , Glaucoma/etiology , Prospective Studies , Risk Factors , Age Factors , Ultrasonography, Doppler, Color , Statistics, Nonparametric , Eye/blood supply , Hemodynamics/physiology
5.
J. vasc. bras ; 16(1): f:4-l:10, Jan.-Mar. 2017. tab
Article in Portuguese | LILACS | ID: biblio-841408

ABSTRACT

Resumo Contexto A doença venosa crônica requer avaliação clínica, quantificação dos efeitos hemodinâmicos e definição da distribuição anatômica para decisão diagnóstica e tratamento. Métodos Estudo prospectivo realizado em 2015 com amostra de 1.384 pacientes (2.669 membros) com idade entre 17 e 85 anos, sendo 1.227 do sexo feminino. Nas respostas do questionário aplicado, os sintomas pesquisados eram dor, cansaço, sensação de peso, queimação, câimbras e formigamento. Para a formação dos grupos, foi considerado o número de membros, distribuídos em relação ao gênero, ao índice de massa corporal e à idade. Após a definição grupos e a realização do eco-Doppler para estudo da veia safena magna (VSM), os pacientes foram distribuídos em três grupos (I: sintomas presentes e varizes ausentes, II: sintomas ausentes e varizes presentes e III: sintomas presentes e varizes presentes). A análise estatística utilizou o teste qui-quadrado ou exato de Fisher para verificar a homogeneidade entre os grupos. Em caso de associação com significância de 5%, foi calculada a razão de chances. Resultados Para ambos os gêneros, foi observada chance de insuficiência da VSM 11,2 vezes maior no grupo III. Por sua vez, os casos de obesidade mórbida ocorreram 9,1 vezes mais no mesmo grupo. Além disso, pacientes na faixa etária entre 30 e 50 anos desse grupo apresentaram chance de insuficiência da VSM 43,1 vezes maior. Conclusões A insuficiência da VSM foi significantemente mais frequente no grupo III, tanto globalmente como considerando apenas os casos de obesidade mórbida e a faixa etária mais elevada.


Abstract Background Chronic venous disease demands clinical assessment, quantification of hemodynamic effects, and definition of anatomic distribution before diagnostic and treatment decisions can be made. Methods This is a prospective study conducted in 2015 with a sample of 1,384 patients (2,669 limbs) aged from 17 to 85 years, 1,227 of whom were female. The most common symptoms reported in response to the questionnaire were pain, tiredness, feelings of heaviness, burning, cramps, and tingling. Subsets were formed on the basis of number of limbs distributed by sex, body mass index, and age. After definition of subsets, Doppler ultrasonography was used to conduct examinations of the great saphenous vein (GSV) and patients were distributed into three clinical groups (I: symptoms present and varicose veins absent, II: symptoms absent and varicose veins present and III: symptoms present and varicose veins present). Statistical analysis employed the chi-square test or Fisher’s exact test to test for homogeneity between groups. When associations significant to 5% were detected, odds ratios were calculated. Results For both sexes, the chance of GSV insufficiency was 11.2 times greater in group III. Among cases with morbid obesity, the chance was 9.1 times greater in the same group. Additionally, patients in this group with ages ranging from 30 to 50 years exhibited a 43.1 times greater chance of GSV insufficiency. Conclusions Insufficiency of the GSV was significantly more frequent in group III, both overall and when considering only cases with morbid obesity, or cases in older age groups.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Saphenous Vein/physiopathology , Saphenous Vein/surgery , Signs and Symptoms , Ultrasonography, Doppler/methods , Varicose Veins/diagnosis , Varicose Veins/physiopathology , Venous Insufficiency/diagnosis , Age Factors , Lower Extremity , Prospective Studies , Risk Factors , Sex Factors , Data Interpretation, Statistical , Venous Thrombosis
6.
Rev. Col. Bras. Cir ; 42(3): 138-142, May-June 2015. ilus
Article in English | LILACS | ID: lil-755991

ABSTRACT

OBJECTIVE:To determine the accuracy of Doppler ultrasonography (USD) for hemodialysis arteriovenous fistula (AVF) maturity. METHODS:we included patients with no prior AVF. Each patient underwent two USD examinations. After initiation of hemodialysis, we followed the patients during the first month of the access use and verified its adequacy to hemodialysis sessions. At statistical analysis we measured specificity, sensitivity, accuracy, ROC curve (Receiver operator characteristic) curve, TG-ROC (Two graph - receiver operator characteristic) and logistic regression. RESULTS:We included 76 patients, of which 51 completed the study. They formed two groups, those who have had good adequacy for hemodialysis (45) and those who had not (6). The average flow volume (FV) and the average draining vein diameter (DVD) of each group were, respectively: 940mL/min (95% CI: 829-1052) and 325mL/min (95% CI: 140-510); and 0.48cm (95% CI: 0.45-0.52) and 0.33cm (95% CI: 0.27-0.40). The area under the ROC curve of FV and DVD were 0.926 and 0.766, respectively. CONCLUSION:The accuracy of the measured volume flow measured at the draining vein to evaluate maturation of hemodialysis arteriovenous fistula was 85%.


OBJETIVO: Testar a acurácia da ultrassonografia com Doppler (USD) na avaliação da maturação do acesso vascular para hemodiálise. MÉTODOS:Foram incluídos pacientes que não haviam feito uma fistula arteriovenosa (FAV) anteriormente. Cada paciente foi submetido a dois exames de USD. Após o início da hemodiálise, foram acompanhados durante o primeiro mês utilizando o acesso e verificando sua adequação às sessões de hemodiálise. Foram aferidas: especificidade, sensibilidade, acurácia, curva ROC (Receiver operator characteristic), curva TG-ROC (Two graph - receiver operator characteristic) e regressão logística. RESULTADOS:Foram incluídos na pesquisa 76 pacientes, 51 concluíram o estudo. O volume de fluxo (VF) médio e o diâmetro médio da veia de drenagem (DVD) foram, respectivamente, para cada grupo: 940 ml/min (IC95%: 829-1052 ml/min); 325 ml/min (IC95%: 140-510 ml/min); e 0,48cm (IC95%: 0,45-0,52 cm); 0,33cm (IC95%: 0,27-0,40 cm). A área sob a curva ROC do VF e do DVD foram, respectivamente, 0,926 e 0,766. CONCLUSÃO:A acurácia da medida de volume de fluxo aferido na veia de drenagem para avaliar a maturação da fistula de hemodiálise foi 85%, o melhor parâmetro disponível isoladamente.


Subject(s)
Humans , Arteriovenous Fistula , Renal Dialysis , Ultrasonography, Doppler, Color
7.
J. vasc. bras ; 14(2): 145-152, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-756464

ABSTRACT

BACKGROUND: Ultrasound-guided foam sclerotherapy plays a major role in treatment of chronic venous insufficiency, providing clinical and hemodynamic improvement to patients undergoing treatment.OBJECTIVES: To examine the relationships between venous refilling time and impact of venous disease on quality of life and between changes in venous refilling time and improvement of symptoms after ultrasound-guided foam sclerotherapy for chronic venous insufficiency. METHODS: Thirty-two patients classified as C4, C5 or C6 answered a questionnaire on quality of life and symptoms and their venous filling time was measured using photoplethysmography before and 45 days after treatment of chronic venous insufficiency with ultrasound-guided foam sclerotherapy.RESULTS: Statistically significant improvements were observed in quality of life scores and in venous filling time and in the following symptoms: aching, heavy legs, restless legs, swelling, burning sensations, and throbbing (p<0.0001). A similar improvement was also seen in the work and social domains of quality of life (p<0.0001).CONCLUSIONS: As confirmed by questionnaire scores and venous refilling times, ultrasound-guided foam sclerotherapy demonstrated efficacy and resulted in high satisfaction levels and low rates of major complications.


CONTEXTO: A escleroterapia com espuma guiada por ultrassom (EGUS) ocupa lugar de destaque no tratamento da insuficiência venosa crônica (IVC), proporcionando melhora clínica e hemodinâmica aos pacientes submetidos ao tratamento.OBJETIVOS: Verificar a correlação entre dados obtidos por questionário de qualidade de vida e de sintomas com dados obtidos por fotopletismografia (FPG), antes e depois do tratamento por escleroterapia com espuma guiada por ultrassom (EGUS) da insuficiência venosa crônica (IVC). MÉTODOS: Um grupo de 32 pacientes, classificados como C4, C5 e C6, foi submetido à aplicação de questionário de qualidade de vida e sintomas, sendo aferido o tempo de enchimento venoso (TEV) por FPG antes e 45 dias depois do tratamento da IVC através de EGUS. O teste do sinal foi utilizado para análise estatística da melhora dos escores dos questionários e do TEV. O teste de McNemar foi utilizado para avaliação da melhora nos sintomas e do impacto do tratamento nas atividades laborais e sociais dos pacientes.RESULTADOS: Houve melhora nos escores dos questionários de qualidade de vida e no TEV, com significância estatística (p<0,0001). Houve melhora estatisticamente significativa nos sintomas: dor, cansaço, edema, queimação, pernas inquietas e latejamento (p<0,0001). Incremento na qualidade laboral e social após o tratamento apresentou melhora estatisticamente significativa (p<0,0001). Não ocorreram complicações maiores ou efeitos adversos nesta série.CONCLUSÕES: A EGUS mostrou-se eficaz, com alto índice de satisfação e baixas taxas de complicacões maiores, ratificada pelos escores dos questionários e pelos TEVs aferidos pela FPG.


Subject(s)
Humans , Male , Female , Middle Aged , Sclerotherapy/methods , Photoplethysmography/methods , Venous Insufficiency/therapy , Quality of Life , Lower Extremity , Surveys and Questionnaires , Data Interpretation, Statistical , Sclerosing Solutions/therapeutic use , Ultrasonography, Doppler, Color/methods , Varicose Veins
8.
J. vasc. bras ; 13(3): 162-167, Jul-Sep/2014. tab
Article in English | LILACS | ID: lil-727128

ABSTRACT

Background: Venous insufficiency is a very prevalent disease. Some decades ago a group of patients was identified that had symptoms of venous insufficiency, but no visible anatomic abnormalities. Studies showed that this subset had reduced venous tone, and their condition became known as hypotonic phlebopathy. Objective: To investigate prevalence, age group and variations in body mass index (BMI) among patients with hypotonic phlebopathy. Methodology: A total of 1,960 limbs were examined in 1,017 patients who had been referred for complaints compatible with venous insufficiency. Patients with BMI ≥ 30 were defined as obese. The patients were examined using color Doppler ultrasonography to detect presence or absence of reflux in veins of the lower limbs and were then distributed into two groups as follows: patients with CEAP ≤ 1 and no reflux, diagnosed with hypotonic phlebopathy; or patients with CEAP ≥ 2 and reflux. Results: The study sample comprised 89.7% women and 10.3% men with a mean age of 44.9 years. Hypotonic phlebopathy was more common among the women (p = 0.0001). Obese women were more likely than women who were not obese to have venous symptom etiology involving trunk lesions (p = 0.0017). Among the men, obesity was unrelated to etiology of symptoms (p = 0.5991). Symptomology was more likely to be related to trunk vein damage among older age groups than among younger age groups (p-valor <0.0001). Conclusions: Hypotonic phlebopathy was very prevalent, particularly among young women who were not obese...


Contexto: A insuficiência venosa é uma doença muito prevalente. Há algumas décadas, evidenciou-se a existência de um grupo que, embora apresentasse sintomas de insuficiência venosa, não possuía alterações anatômicas visíveis. Estudos mostraram redução no tônus venoso nesses indivíduos, denominando-os portadores de flebopatia hipotônica. Objetivo: Estudar a prevalência, a faixa etária e as variações do índice de massa corporal (IMC) em pacientes portadores de flebopatia hipotônica. Metodologia: Foram examinados 1.960 membros de 1.017 pacientes, devido a queixas compatíveis com insuficiência venosa. Foram considerados obesos aqueles com IMC ≥ 30. Foram avaliados com ecocolor Doppler, para se detectar a presença ou não de refluxo em veias dos membros inferiores, sendo então distribuídos em dois grupos: aqueles com CEAP ≤ 1, além de excluído refluxo, os portadores de flebopatia hipotônica, e outros com CEAP ≥ 2 e com refluxo. Resultados: A amostra foi composta por 89,7% de mulheres e 10,3% de homens, com faixa etária média de 44,9 anos. A flebopatia hipotônica foi mais comum em mulheres (p-valor = 0,0001). Naquelas obesas, houve mais lesão troncular como etiologia dos sintomas venosos do que nas não obesas (p-valor = 0,0017). Dentre os homens, a presença de obesidade não influenciou na etiologia dos sintomas (p-valor = 0,5991). Nos grupos etários de idade mais avançada, a presença de sintomatologia teve como origem etiológica a lesão venosa troncular com mais frequência do que nas faixas etárias mais jovens (p-valor <0,0001). Conclusão: A flebopatia hipotônica se mostrou muito prevalente, principalmente em mulheres jovens não obesas...


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged, 80 and over , Peripheral Vascular Diseases/etiology , Peripheral Vascular Diseases , Lower Extremity , Venous Insufficiency/etiology , Venous Insufficiency/physiopathology , Varicose Veins/complications , Echocardiography, Doppler/methods , Retrospective Studies , Risk Factors
9.
J. vasc. bras ; 12(4): 296-302, Oct-Dec/2013. graf
Article in English | LILACS | ID: lil-699139

ABSTRACT

The process of recanalization of the veins of the lower limbs after an episode of acute deep venous thrombosis is part of the natural evolution of the remodeling of the venous thrombus in patients on anticoagulation with heparin and vitamin K inhibitors. This remodeling involves the complex process of adhesion of thrombus to the wall of the vein, the inflammatory response of the vessel wall leading to organization and subsequent contraction of the thrombus, neovascularization and spontaneous lysis of areas within the thrombus. The occurrence of spontaneous arterial flow in recanalized thrombosed veins has been described as secondary to neovascularization and is characterized by the development of flow patterns characteristic of arteriovenous fistulae that can be identified by color duplex scanning. In this review, we discuss some controversial aspects of the natural history of deep vein thrombosis to provide a better understanding of its course and its impact on venous disease.


O processo de recanalização das veias dos membros inferiores, após um episódio de trombose venosa profunda aguda em pacientes anticoagulados com heparina e inibidores da vitamina K, faz parte da evolução natural da remodelagem do trombo venoso. Esse complexo processo de remodelagem envolve a adesão do trombo à parede da veia, à resposta inflamatória da parede do vaso, levando à organização e subsequente contração do trombo, à neovascularização e à lise espontânea de áreas no interior do trombo. A presença de fluxo arterial espontâneo em veias com trombose recanalizada tem sido descrita como secundária à neovascularização e se caracteriza pelo desenvolvimento de fluxo com padrão de fístulas arteriovenosas, identificadas por meio de mapeamento dúplex colorido. Nesta revisão, são discutidos alguns aspectos controversos da história natural da trombose venosa profunda, para uma melhor compreensão da sua evolução e do seu impacto sobre a doença venosa.


Subject(s)
Adult , Lower Extremity/physiopathology , Venous Thrombosis/diagnosis , Venous Thrombosis/epidemiology , Venous Thrombosis/history , Heparin Antagonists/administration & dosage , Echocardiography, Doppler/methods , Heparin/administration & dosage , Risk Factors
10.
Rev. bras. cir. cardiovasc ; 28(4): 477-481, out.-dez. 2013. tab
Article in Portuguese | LILACS | ID: lil-703115

ABSTRACT

OBJETIVO: Avaliar a influência do comprimento cabeça-nádega e do índice de massa corporal na avaliação ultrassonográfica do coração fetal, pelas vias abdominal e vaginal, no primeiro trimestre de gestação. MÉTODOS: Realizou-se um estudo de corte transversal com 57 gestantes normais entre 12 a 14 semanas (CCN < 84 mm). Foram avaliados os seguintes planos cardíacos, pelas vias abdominal e vaginal: quatro câmaras, via de saída do ventrículo direito, via de saída do ventrículo esquerdo e arco aórtico. Utilizou-se o modo B, Doppler colorido e ultrassonografia de quarta dimensão (spatio-temporal image correlation). Para avaliar a influência do comprimento cabeça-nádega e índice de massa corporal na avaliação dos planos cardíacos fetal, utilizou-se o teste t não-pareado. RESULTADOS: Não se observou diferenças estaticamente significativas nas taxas de sucesso e insucesso entre as vias abdominal e vaginal em relação ao índice de massa corporal, contudo, observou-se maior taxa de insucesso na avaliação vaginal utilizando o modo B associado ao Doppler colorido (P<0,01). CONCLUSÃO: O índice de massa corporal e o comprimento cabeça-nádega não tiveram interferência na avaliação cardíaca fetal no primeiro trimestre de gestação.


OBJECTIVE: To evaluate the influence of the crown-rump length and body mass index on sonographic evaluation of the fetal heart using abdominal and vaginal routes in the first trimester of pregnancy. METHODS: We conducted a cross-sectional study with 57 pregnant women between 12-14 weeks (CRL< 84 mm). We evaluated the following fetal cardiac plans using the abdominal and vaginal routes: four-chamber view, right ventricle outflow tract, left ventricle outflow tract and aortic arch. We used the B-mode, color Doppler and four-dimensional ultrasonography (spatio-temporal image correlation). To evaluate the influence of crown-rump length and body mass index in the assessment of fetal cardiac planes, we used the t test unpaired. RESULTS: There were no statistically significant differences in the rates of success and failure between abdominal and vaginal routes in relation to body mass index, however, there was a higher failure rate in vaginal assessment using B mode associated with color Doppler (P<0.01). CONCLUSION: The crown-rump length and body mass index had no interference in fetal cardiac assessment in the first trimester of pregnancy.


Subject(s)
Adolescent , Adult , Female , Humans , Pregnancy , Young Adult , Body Mass Index , Crown-Rump Length , Fetal Heart/anatomy & histology , Pregnancy Trimester, First , Cross-Sectional Studies , Fetal Heart , Gestational Age , Prospective Studies , Ultrasonography, Doppler, Color , Ultrasonography, Prenatal/methods
11.
Rev. Col. Bras. Cir ; 40(5): 380-385, set.-out. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-698074

ABSTRACT

OBJETIVO: avaliar a ocorrência do refluxo da safena magna através da ultrassonografia com Doppler colorido em sujeitos submetidos ao tratamento da insuficiência da junção safeno-femoral por ligadura simples ou por ligadura com secção da crossa. MÉTODOS: foram realizadas 60 operações (45 sujeitos) de varizes com insuficiência da junção safeno-femoral (JSF), pertencentes à classificação clínica do CEAP 2 a 5, que foram distribuídos aleatoriamente em dois grupos. Um grupo denominado C, com ligadura e secção da crossa, e um grupo denominado L, com ligadura simples sem secção da crossa da veia safena magna. Foi então pesquisada a ocorrência do refluxo da safena magna nos grupos C e L através da ultrassonografia doppler colorida após o tratamento cirúrgico com intervalos de seis meses a um ano. RESULTADOS: dos 60 membros submetidos à abordagem da crossa da safena magna, 57 foram avaliados pela ultrassonografia doppler pós-operatório, pois dois sujeitos (três membros) não retornaram e foram excluídos do estudo. A média de idade foi 54 anos, 93% do sexo feminino e predominância da classificação (CEAP) C2 de 60,5%. Das 57 operações para o tratamento do refluxo da crossa da safena, 43,9% apresentaram refluxo no pós-operatório, sendo 14,1% do grupo C e 29,8% no grupo L (p<0,05). O risco relativo de apresentar refluxo da crossa da safena no grupo L foi 2,03 vezes maior em comparação com o grupo C. CONCLUSÃO: a secção da crossa da safena magna apresenta menos refluxo pós-operatório do que a ligadura simples no tratamento da insuficiência da crossa da veia safena magna.


OBJECTIVE: To evaluate the occurrence of reflux from the great saphenous vein by color Doppler ultrasonography in subjects undergoing treatment of insufficiency of the saphenofemoral junction by simple ligation or ligation with section of the saphenous arch. METHODS: We performed 60 operations (in 45 subjects) of varicose insufficiency of the saphenofemoral junction (SFJ), belonging to the CEAP clinical classification of 2-5, who were randomly divided into two groups. A group called C, with ligature and section of the saphenous arch, and a group called L, with simple ligation of the saphenous vein and no sectioning of its arch. We then investigated the occurrence of reflux from the great saphenous vein in groups C and L through postoperative color Doppler ultrasonography at intervals of six months to one year. RESULTS: Of the 60 members submitted to the approach of the saphenous arch, 57 were evaluated by postoperative doppler ultrasound, since two subjects (three limbs) did not return and were excluded from the study. The mean age was 54 years, with 93% females and predominance of CEAP classification 2 in 60.5%. Of the 57 operations for the treatment of reflux of the saphenous arch, 43.9% had reflux postoperatively,14.1% in group C and 29.8% in group L (p < 0,05). The relative risk of reflux of the saphenous arch in group L was 2.03 times higher compared with group C. CONCLUSION: the section of the arch of the great saphenous vein causes less postoperative reflux than simple ligation in treatment of insufficiency of the great saphenous vein.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Femoral Vein/surgery , Femoral Vein , Postoperative Complications , Saphenous Vein/surgery , Saphenous Vein , Ultrasonography, Doppler, Color , Venous Insufficiency/surgery , Ligation , Postoperative Complications/physiopathology , Regional Blood Flow , Saphenous Vein/physiopathology
12.
Rev. méd. Minas Gerais ; 23(3)jul.-set. 2013.
Article in Portuguese, English | LILACS | ID: lil-702900

ABSTRACT

Objetivo: caracterizar clínica e pela ultrassonografia (US) a hipertensão portal idiopática. Pacientes e métodos: foram avaliados, retrospectivamente, por US com doppler colorido, 60 pacientes com diagnóstico clínico de hepatopatia crônica e hipertensão portal, de janeiro de 1996 a janeiro de 2006, em clínica privada, encontrando dois casosde hipertensão portal idiopática. Comentários: em jovens com esplenomegalia, hematêmese recorrente, anemia, ascite, funções hepáticas normais e hipertensão portal sem evidência de cirrose, foram observados à US fígado de tamanho usual, textura heterogênea e superfície lisa, ausência de deformidades das ramificações das veias portais intra-hepáticas, espessamento da parede da veia porta maior ou igual a 3 mm e estreitamento abrupto das veias portais secundárias intra-hepáticas acompanhado de esplenomegalia.


Objective: to characterize idiopathic portal hypertension clinically and by ultrasound (US). Patients and methods: 60 patients with clinical diagnosis of chronic liver disease and portal hypertension were retrospectively assessed by color Doppler US, from January 1996 to January 2006, in a privately owned clinic. Two cases of idiopathic portal hypertension were found. Comments: in young patients with splenomegaly, recurring hematemesis, anemia, ascites, normal liver function and portal hypertension without evidence of cirrhosis, US revealed livers of usual size, heterogeneous texture and flat surface, without deformities in the branches of the intra-hepatic portal veins. The portal vein walls were also thickened starting at 3 mm and marked by an abrupt narrowing of the secondary intra-hepatic portal veins, accompanied by splenomegaly.


Subject(s)
Humans , Male , Female , Adult , Liver Diseases/pathology , Hypertension, Portal , Biopsy , Retrospective Studies , Ultrasonography, Doppler, Color
13.
Rev. méd. Minas Gerais ; 23(3)jul.-set. 2013.
Article in Portuguese, English | LILACS | ID: lil-702916

ABSTRACT

Relata-se a inserção velamentosa do cordão umbilical diagnosticada durante o parto gemelar normal, evento raro e com mais incidência em gestações múltiplas. É, em geral, assintomático, quando a paciente não entra em trabalho de parto, devendo a gestação ser interrompida por cesariana. A vasa prévia constitui-se em sua complicação rara, podendo ser letal. A ultrassonografia é fundamental para a realização de seu diagnóstico.


A report of velamentous insertion of the umbilical cord diagnosed during a normal twin delivery, a rare event with higher incidence in multiple pregnancies. Because it is generally asymptomatic, when the mother does not go into labor, pregnancy must be interrupted by performing a caesarean delivery. Previous vasa is a rare complication and can be lethal. Ultrasound is crucial for diagnosis.


Subject(s)
Humans , Female , Pregnancy , Adult , Umbilical Cord/blood supply , Vasa Previa , Prenatal Diagnosis , Pregnancy, Twin , Natural Childbirth , Ultrasonography, Doppler, Color
14.
Rev. méd. Minas Gerais ; 23(1)jan.-mar. 2013.
Article in Portuguese, English | LILACS | ID: lil-702862

ABSTRACT

Objetivo: este trabalho analisa as alterações ultrassonográficas que caracterizam a síndrome de Cruveilhier-Baumgarten (SCB), com suas alterações clínicas. A SCB caracteriza-se pela veia paraumbilical proeminente, com dilatação das veias superficiais da parede abdominal de aspecto radiado provenientes do umbigo dos pacientes com hepatopatia crônica e hipertensão portal. Casuística e métodos: em avaliação ultrassonográfica de 60 pacientes com diagnóstico de hepatopatia crônica com hipertensão portal foram encontrados quatro casos com a SCB em que foi realizado o estudo por meio do doppler colorido. Resultados: todos os pacientes avaliados eram do gênero masculino, estavam na terceira década de vida, tinham história de esplenomegalia, varizes na parede abdominal e eram portadores de esquistossomose e aspecto histopatológico de cirrose micronodular. Foram analisados também dois pacientes com varizes do esôfago sem clinica de hematêmese. Ultrassonograficamente, todos os pacientes tinham sinais de hepatopatia crônica com esplenomegalia, com fluxo hepatopetal em todos os segmentos da veia porta e fluxo hepatofugal nas veias que deixam o fígado (veia paraumbilical no ligamento falciforme e nas veias superficiais da parede abdominal anterior). Conclusão: a SCB caracteriza-se pela associação de sinais de hepatopatia crônica com esplenomegalia, veias paraumbilicais com aumento de calibre (hipertensão porta) e com fluxo para as veias superficiais da parede abdominal, que se acham dilatadas na região umbilical e com sopro à ausculta pelo ultrassom e ao exame físico.


Objective: The purpose of this paper is to analyze the sonographic changes that characterize the Cruveilhier-Baumgarten syndrome and its clinical charactheristics. Cruveilhier- Baumgartem syndrome is characterized by a prominent paraumbilical vein, with dilatated superficial veins of the abdominal wall radiating from the umbilicus of patients with chronic liver disease and portal hypertension. Patients and methods: In a sonographic evaluation of 60 patients diagnosed with chronic liver disease with portal hypertension we found 4 cases of Cruveilhier-Baumgarten syndrome, which we studied with color doppler sonography.Results: All patients were male, in their third decade of life, with a clinical history of splenomegaly and varicose abdominal wall veins. Patients had schistosomiasis and micronodular cirrhosis on hystopathological examination. We also evaluated two patients with esophageal varices without hemathemesis. All patients had ultrasound signs of splenomegaly and chronic liver disease, with hepatopetal flow in all segments of the portal vein and hepatofugal flow in the efferent veins of the liver (paraumbilical vein in the falciform ligament and the anterior abdominal wall surface veins). Conclusion: CBS is charactherized by the associationof signs of chronic liver damage with splenomegaly, distention of paraumbilical veins (portal hypertension) and blood flow towards the superficial abdominal wall veins, which are dilated in the umbilical region, associated with an audible bruit in both clinical and sonographic examination.


Subject(s)
Humans , Liver Diseases/complications , Hypertension, Portal , Liver Cirrhosis , Splenomegaly , Ultrasonography, Doppler, Color
15.
J. vasc. bras ; 11(2): 137-143, abr.-jun. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-641660

ABSTRACT

A trombose venosa profunda é uma entidade clínica potencialmente grave, responsável por elevada morbimortalidade. A ecografia vascular representa o método propedêutico de escolha no diagnóstico e acompanhamento dos pacientes com essa doença. Entretanto, várias questões permanecem controversas, tais como a abordagem inicial do paciente com suspeita de trombose venosa profunda, os tipos de protocolo a serem usados, o tempo para a realização do exame e a trombose no plexo de panturrilha. O objetivo dessa revisão é discutir esses assuntos à luz dos conhecimentos atuais.


Deep vein thrombosis is a potentially serious clinical entity, responsible for high morbidity and mortality. The vascular ultrasound is the diagnostic methods of choice in the diagnosis and monitoring of patients with this disease. However, several issues remain controversial, such as the initial approach of patients with suspected deep vein thrombosis, protocols to be used, the time for the exam and thrombosis in the calf plexus. The objective of this review is to discuss these issues in light of current knowledge.


Subject(s)
Humans , Health Knowledge, Attitudes, Practice , Venous Thrombosis/diagnosis , Venous Thrombosis/therapy , Venous Thrombosis , Brazil/ethnology , Clinical Protocols , Emergency Medical Services/classification
16.
Acta cir. bras ; 27(2): 148-154, Feb. 2012. ilus, tab
Article in English | LILACS | ID: lil-614534

ABSTRACT

PURPOSE: To evaluate the osteo-regenerative capacity of proprietary bone grafting material as a bone defect filler and osteogenetic stimulation to speed up bone healing too. METHODS: Eighteen adult male New Zealand white rabbits were anesthetized and a segmental full thickness bone defect of 10 mm in length was created in the middle of the right radial shaft in all rabbits. They were divided into two groups of 9 rabbits. Group I was considered as control and the fractured site was fixed using finger bone plate with 4 screws, whereas the cancellous bone scaffold coated with Nano-Hydroxyapatite was used to fill the gap after fracture fixation in Group II. Radiography, two dimensional and color Doppler ultrasonography were done before and after creating defects and on 0, 15, 30, 60 and 90 days to evaluate local reaction as far as new blood vessels network and callus formation are observed. RESULTS: On the radiographs during the whole process, bone repair in Group I was not as perfect as those in Group II samples and trace of internal callus filled the gap incompletely in 60 days in Group I, whereas in Group II internal callus almost was formed on 30 days and in addition intercortical callus was seen supporting to cover and filled the gap completely in this group in 60 day; Sonographic findings confirmed the protrusion of newly formed blood vascular network in 30 days in Group I and from 15 days in Group II and remarkably increased till end of observation period. CONCLUSIONS: The nano-hydroxyapatite with more features and shorter in time, made possible the reconstruction of bone tissue and alternative techniques as well as previous bone graft, also radiography and ultrasonography are reliable techniques to trace local reaction at proper time.


OBJETIVO: Avaliar a capacidade osteo-regenerativa de biomaterial no preenchimento de defeito ósseo e como estímulo osteogênico para acelerar a cicatrização óssea. ÉTODOS: Dezoito coelhos brancos, Nova Zelandia, adultos, machos foram anestesiados e um defeito ósseo segmentar de toda a espessura e 10 mm de comprimento foi criado no meio do eixo do osso radial direito de todos os coelhos. Os animais foram distribuídos em dois grupos de nove: Grupo I foi considerado como controle e o local da fratura foi fixado usando placa de dedo de osso com quatro parafusos, enquanto o molde de osso esponjoso revestido com nano-hidroxiapatita foi usado para preencher o espaço após fixação da fratura no Grupo II. Radiografia, bidimensional e ultrassonografia Doppler colorida foi feita antes e após criar os defeitos e nos dias 0, 15, 30, 60 e 90 para avaliar a reação local tais como nova rede vascular e formação do calo ósseo. RESULTADOS: Nas radiografias durante todo o processo, o reparo ósseo no Grupo I não foi perfeito como no Grupo II; amostras e traços de calo ósseo preencheram o espaço de forma incompleta em 60 dias no Grupo I, enquanto no Grupo II o calo ósseo interno foi quase formado em 30 dias e, além disso, calo intercortical foi visto apoiar para revestir e preencher o espaço completamente em 60 dias; nos achados ultrassonográficos a protrusão da rede vascular neoformada em 30 dias no Grupo I e a partir de 15 dias no Grupo II e acentuado aumento até o fim do período de observação. CONCLUSÕES: A nano-hidroxiapatita, com mais propriedade e menor período de tempo, tornou possível a reconstrução de tecido ósseo e técnicas alternativas como o enxerto ósseo prévio, assim como a radiografia e a ultrassonografia são técnicas confiáveis para traçar a reação local em tempo adequado.


Subject(s)
Animals , Male , Rabbits , Bone Regeneration/physiology , Bone Substitutes/therapeutic use , Fracture Healing/drug effects , Hydroxyapatites/therapeutic use , Tissue Scaffolds , Ultrasonography, Doppler, Color/methods , Biocompatible Materials/therapeutic use , Bone Transplantation/methods , Nanocomposites/therapeutic use , Reproducibility of Results , Radius/physiopathology , Radius , Radius/ultrastructure , Time Factors
17.
J. vasc. bras ; 10(4): 330-334, dez. 2011. ilus
Article in Portuguese | LILACS | ID: lil-610957

ABSTRACT

O deslocamento de um shunt para um ramo arterial mais distal, percorrendo um longo trajeto, é uma complicação rara. A ultrassonografia vascular pode se apresentar como uma excelente modalidade diagnóstica para identificar o sítio de embolização de corpos estranhos intravasculares. Os autores relatam um caso raro de migração de um shunt temporário, implantado na carótida comum esquerda, para artéria poplítea esquerda. Descrevem, ainda, a utilização do ecocolor doppler arterial que, além de localizar o ponto de embolização, com uma dermatografia exata, foi fundamental para que a abordagem cirúrgica transcorresse com facilidade através de uma via de acesso restrita e precisa.


The displacement of a shunt to a more distal arterial branch, along a path, is a rare complication. Vascular ultrasound can be presented as an excellent diagnostic modality for identifying the site of embolization of intravascular foreign bodies. The authors report a rare case of temporary shunt migration, implanted in the left common carotid artery, to left popliteal artery. The authors also describe the use of arterial vascular ultrasound to find the point of embolization, with an exact dermatography, that was essential to an easily surgical approach through a restrict and precise access way.


Subject(s)
Humans , Popliteal Artery/anatomy & histology , Popliteal Artery , Embolization, Therapeutic/classification , Echocardiography, Doppler/nursing
18.
Arq. bras. oftalmol ; 74(5): 361-364, set.-out. 2011. ilus
Article in Portuguese | LILACS | ID: lil-608410

ABSTRACT

OBJETIVO: Determinar se as variáveis obtidas com exame Doppler colorido associadas às de campo visual são capazes de discriminar olhos normais de olhos glaucomatosos. MÉTODOS: Foram avaliados prospectivamente 36 pacientes portadores de glaucoma primário de ângulo aberto em uso de medicação antiglaucomatosa (grupo glaucoma) e 20 voluntários normais (grupo controle). Analisou-se a distribuição dos grupos quanto ao sexo, idade, espessura corneana central, pressão intraocular, índices globais da perimetria computadorizada Octopus ("mean defect" e "loss variance") e os parâmetros do Doppler colorido (velocidade sistólica máxima e índice de resistência). RESULTADOS: Não houve diferença estatística significativa entre os grupos em relação à idade, espessura corneana e pressão intraocular. A análise discriminante mostrou que as variáveis: índice de resistência (IR) da artéria ciliar curta posterior (ACCP), "mean defect" (MD) e "loss variance" (LV) apresentaram influência estatisticamente significativa para o diagnóstico positivo de glaucoma. A função discriminante obtida foi: -3,637 + 0,109 MD + 0,028 LV + 4,325 IR ACCP. A probabilidade do diagnóstico positivo do glaucoma a partir do "score" -1,61 foi de 90 por cento. CONCLUSÃO: Foi possível identificar através da análise discriminante, quais das variáveis do Doppler colorido que, associados às do campo visual, permitiram diferenciar pacientes glaucomatosos de normais. Essas variáveis foram: índice de resistência da artéria ciliar curta posterior e índices da perimetria computadorizada "mean defect" e "loss variance".


PURPOSE: To determine if variables from color Doppler and visual field exam could discriminate normal from glaucomatous eyes. METHODS: Prospectively, 36 patients with primary open-angle glaucoma (glaucoma group) and 20 normal volunteers (control group) were studied. Gender, age, central corneal thickness, intraocular pressure, Octopus automated perimetry global indices (mean defect and loss variance) and several parameters of the color Doppler (peak systolic velocity and resistivity index) were compared between groups. RESULTS: There was no statistically significant difference in age, central corneal thickness and intraocular pressure. Discriminant analysis showed that the variables: resistivity index (RI) in the short posterior ciliary artery (SPCA), mean defect (MD) and loss variance (LV) had presented significant influence for the positive diagnosis of glaucoma. The gotten discriminant function was: -3.637 + 0.109 x MD + 0.028 x LV + 4.325 x RI SPCA. Considering score -1.61, the probability of positive diagnosis of glaucoma was 90 percent. CONCLUSION: Through discriminant analysis it was possible to identify which of the color Doppler variables that associated to the visual field variables allowed differentiate normal from glaucomatous patients. These variables were: resistivity index in the short posterior ciliary artery, and the visual field variables, mean defect and loss variance.


Subject(s)
Humans , Middle Aged , Glaucoma, Open-Angle/diagnosis , Ultrasonography, Doppler, Color , Visual Field Tests/methods , Case-Control Studies , Discriminant Analysis , Glaucoma, Open-Angle/drug therapy , Prospective Studies
19.
J. vasc. bras ; 10(3): 198-204, jul.-set. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-604462

ABSTRACT

CONTEXTO: A recidiva de varizes em membros inferiores é complicação frequente da safenectomia e sua incidência atinge até 80 por cento dos casos. OBJETIVO: Avaliar a sensibilidade do exame físico e do mapeamento com eco-color Doppler no diagnóstico da insuficiência do coto da veia safena magna, em doentes previamente operados, comparando-os com os achados da exploração operatória da junção safeno-femoral. MÉTODOS: Foram estudados prospectivamente 30 doentes envolvendo 37 membros submetidos previamente à safenectomia magna para tratamento de varizes e que foram reoperados por recidiva de varizes na região inguinal ou em face anterossuperior da coxa. Todos os doentes foram submetidos ao mapeamento com eco-color Doppler. Os dados foram comparados com os achados da exploração da crossa da veia safena magna na reoperação. RESULTADOS: A sensibilidade do mapeamento com eco-color Doppler para a presença de insuficiência do coto da veia safena magna foi de 70,3 por cento (26 concordâncias dentre os 37 membros) e resultados falsos negativos ocorreram em 29,7 por cento (11) membros avaliados (p=0,03). A sensibilidade do achado de varizes na região inguinal e na face anteromedial da coxa com a presença de insuficiência do coto da veia safena magna foi de 100 por cento (37 concordâncias dentre os 37 membros) e não houve resultados falsos negativos. CONCLUSÕES: No doente já submetido à safenectomia magna, a presença no exame físico de varizes recidivadas em região inguinal e na face anteromedial da coxa é sugestivo de insuficiência do coto da veia safena magna, devendo-se realizar o mapeamento com eco color Doppler para o adequado planejamento da reexploração da crossa da veia safena magna.


BACKGROUND: Recurrent varicose veins of the lower limbs are a frequent complication of saphenous vein stripping and their incidence may reach 80 percent of the cases. OBJECTIVE: To evaluate the sensitivity of physical examination and color-Doppler flow mapping for the diagnosis of insufficiency in the greater saphenous vein stump in patients who had previously undergone saphenous vein stripping, comparing the results with the findings at reoperation of the saphenofemoral junction. METHODS: This prospective study included 37 limbs of 30 patients who had been previously submitted to saphenous vein stripping to treat varicose veins. Color-Doppler flow mapping was performed in all patients. Results were compared with findings at reoperation of the saphenofemoral junction. RESULTS: The sensitivity of color-Doppler flow mapping was 70.3 percent (26 limbs out of 37 limbs) and false negative results occurred in 11 (29.7 percent) limbs (p=0.03). The sensitivity of finding varicose veins in the groin and/or in the anteromedial aspect of the upper thigh was 100 percent (37 limbs out of 37 limbs), without false-negatives. CONCLUSIONS: In patients previously submitted to saphenous vein stripping, recurrent varicose veins found at physical examination in the groin or anteromedial aspect of the upper thigh are suggestive of greater saphenous vein stump insufficiency. Color-Doppler flow mapping should be performed for an adequate saphenofemoral junction reoperation.


Subject(s)
Humans , Vascular Diseases/surgery , Vascular Diseases , Lower Extremity/surgery , Varicose Veins , Echocardiography, Doppler, Color/nursing , Incidence , Saphenous Vein/pathology
20.
Rev. Assoc. Med. Bras. (1992) ; 57(2): 187-193, mar.-abr. 2011. tab
Article in Portuguese | LILACS | ID: lil-584071

ABSTRACT

OBJETIVO: Avaliar a prevalência de estenose hemodinamicamente significativa na revascularização infrainguinal realizada com a veia safena magna reversa. MÉTODOS: No período compreendido entre março de 2008 e março de 2009, foram realizadas 56 revascularizações infrainguinais com a veia safena magna reversa em 56 pacientes, dos quais 32 foram avaliados com ultrassonografia vascular no 30º dia de pós- operatório. Foi analisada a prevalência de estenoses significativas nos enxertos e sua relação com as características clínico-cirúrgicas dos pacientes. Os parâmetros avaliados foram a localização das estenoses ao longo do enxerto, fatores de risco associados e a relação existente entre a ultrassonografia vascular e o índice tornozelo-braço no diagnóstico de estenoses. RESULTADOS: Houve prevalência de 48,4 por cento de estenoses significativas nos enxertos avaliados, com 19,4 por cento de estenoses graves e 29 por cento de estenoses leve a moderada. Não foram encontradas associações significativas entre sexo, diabetes mellitus, hipertensão arterial, hipercolesterolemia, diâmetro do enxerto, localização da anastomose distal, composição do enxerto e a constatação de estenoses significativas. Observou-se fraca correlação entre os métodos no diagnóstico das estenoses em geral (K = 0,30; IC95 por cento 0,232-0,473; p = 0,018), mas razoável concordância no diagnóstico das estenoses graves (K = 0,75; IC95 por cento 0,655-0,811; p = 0,0001). CONCLUSÃO: Este estudo demonstrou elevada prevalência de estenoses no 30º dia do pós-operatório, com localização predominante na metade proximal do enxerto. O índice tornozelo-braço e a ultrassonografia vascular apresentaram concordância, sobretudo no diagnóstico das estenoses graves, mas o índice tornozelo-braço, isoladamente, mostrou-se insuficiente na vigilância dos enxertos de veia safena magna reversa.


OBJECTIVE: The aim of this study was to evaluate the prevalence of hemodynamically significant infrainguinal bypasses stenosis using reverse great saphenous vein graft. METHODS: From March of 2008 to March of 2009, 56 infrainguinal bypasses were performed with reverse great saphenous vein graft in 56 patients. On the 30th post-operative day, 32 out of 56 patients were submitted to vascular ultrasonography. The prevalence of significant graft stenosis was determined. In addition, the diagnosis of stenosis was related to the clinical and surgical characteristics of the patients. The variables analyzed at the moment of diagnosis were the localization of the graft stenosis, the risk factors associated with stenosis and the association of vascular ultrasonography findings with ankle brachial pressure index (ABI). RESULTS: The overall prevalence of significant graft stenosis was 48.4 percent. Out of the total number of observed stenosis, 19.4 percent were considered severe, and 29 percent mild or moderate. There was no significant association between the presence of significant stenosis and the following variables: gender, diabetes, hypertension, smoking, hipercholesterolemia, graft diameter, site of the distal anastomosis, and graft composition. There was a weak agreement between ABI and vascular ultrasonography in detecting stenosis in general (K = 0.30; CL95 percent 0.232 - 0.473; p = 0.018). However, there was a substantial agreement in detecting severe stenosis (K = 0.75; CL95 percent 0.655 - 0.811; p = 0.0001). CONCLUSION: There was a high prevalence of stenosis on the 30th post-operative day, mostly localized in the proximal half of the vein graft. There was no significant association of stenosis with clinical and surgical factors analyzed. ABI and vascular ultrasonography had weak agreement with the diagnosis of stenosis in general and an important agreement for the diagnosis of severe stenosis.


Subject(s)
Female , Humans , Male , Constriction, Pathologic/etiology , Graft Occlusion, Vascular/epidemiology , Saphenous Vein/transplantation , Ankle Brachial Index , Arteries , Constriction, Pathologic/epidemiology , Constriction, Pathologic , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular , Prevalence , Risk Factors , Saphenous Vein , Ultrasonography, Doppler, Duplex
SELECTION OF CITATIONS
SEARCH DETAIL