Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Biosci. j. (Online) ; 34(4): 899-906, july/aug. 2018. tab, ilus
Article in English | LILACS | ID: biblio-967035

ABSTRACT

Recently a micro spray and an end cap with drain valve device were launched on the market. Their main advantage is the low cost. The micro spray provides a higher percentage of irrigated area relative to the drippers and an end cap with drain valve removes all air from the pipes and minimizes obstructions of the emitters. However, these components need to be tested operating with different water quantities and qualities. Therefore, this study aimed to evaluate the performance of this micro spray and end cap with drain valve operating with water containing different concentrations of total solids. The experiment was conducted in a split plot scheme, with two end caps in the plots (conventional and with drain valve) and five total solid concentrations in the subplots (7 mg L-1, 407 mg L-1, 1007 mg L-1, 2007 mg L-1 and 4007 mg L-1) in a completely randomized design, with three replications. Sixty evaluations of the irrigation system were performed and the emitters were evaluated every application of 60 L up to a volume of 3.6 m3. The water flow rate and application uniformity were evaluated through distribution uniformity (DU) and statistical uniformity (US) coefficients. The micro spray performance was not affected by water application containing total solid concentrations below 270 and 500 mg L-1 in irrigation systems equipped with conventional end caps or with drain valves, respectively. Irrigation systems equipped with end caps with drain valve provided a better performance of micro sprays when operating with water containing total solid concentrations greater than 407 mg L-1. These end caps did not provided difference in micro spray performance when operating with public water.


Recentemente foi lançado no mercado um micro spray e um dispositivo fim de linha autolimpante tendo como principais vantagens o baixo custo. O micro spray propicia maior porcentagem de área irrigada em relação aos gotejadores e o fim de linha autolimpante retiram todo o ar das tubulações e minimizam o entupimento dos emissores. Entretanto, esses componentes precisam ser testados operando com diferentes quantidades e qualidades de água. Diante disso, o presente trabalho teve como objetivo avaliar o desempenho do micro spray e da válvula autolimpante operando com águas contendo diferentes concentrações de sólidos totais. O experimento foi conduzido em esquema de parcelas subdivididas, tendo nas parcelas dois finais de linha (convencional e válvula autolimpante) e nas subparcelas cinco águas com concentrações de sólidos totais (7 mg L-1, 407 mg L-1, 1.007 mg L-1, 2.007 mg L-1 e 4.007 mg L-1) no delineamento inteiramente casualizado (DIC), com três repetições. Foram realizadas 60 avaliações do sistema de irrigação e os emissores eram avaliados a cada aplicação de 60 L, acumulando o volume de 3,6 m3. Os parâmetros avaliados foram a vazão e as uniformidades de aplicação de água por meio dos coeficientes de distribuição (CUD) e estatístico (CUE). O desempenho dos micros spray testados não foi afetado com aplicação de águas contendo concentrações de sólidos totais inferiores a 270 e 500 mg L-1 nos sistemas de irrigação equipados com finais de linha convencionais e autolimpantes, respectivamente. Sistemas de irrigação equipados com finais de linha autolimpantes proporcionam melhor desempenho dos micros spray quando operam com águas contendo concentrações de sólidos totais superiores a 407 mg L-1. Esses mesmos finais de linha não proporcionam diferença no desempenho dos micros spray quando operam com água de abastecimento.


Subject(s)
Total Solids , Trickling Irrigation , Organic Matter , Agricultural Irrigation , Wastewater
2.
Ciênc. rural ; 38(7): 1886-1892, out. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-495096

ABSTRACT

Os distribuidores centrífugos revolucionaram a tecnologia de aplicação de produtos sólidos na agricultura por apresentarem grande capacidade de campo operacional e pela grande amplitude de dosagens que consegue aplicar. No entanto, este equipamento apresenta alguns inconvenientes, como a dificuldade em aplicar homogeneamente o material na largura de trabalho utilizada, mesmo com uma aparente facilidade de regulagem. O objetivo deste trabalho foi comparar tratamentos relacionados a regulagens operacionais buscando equilibrar e uniformizar o perfil transversal de distribuição, com a maior capacidade de campo operacional, para os diferentes produtos sólidos. A máquina avaliada foi um distribuidor centrífugo de produtos sólidos bidisco. Os resultados nos levam a concluir que as velocidades média e alta da esteira transportadora para a distribuição de calcário e a velocidade baixa para a distribuição de aveia fornecem uma ampla e suficiente faixa de dosagens com a variação de abertura da comporta dosadora. O aumento da vazão e do adiantamento da posição das aletas possibilita maior capacidade de campo operacional ao conjunto mecanizado, pela possibilidade de operar com maior largura útil de aplicação e maior velocidade de deslocamento. A largura máxima recomendada de aplicação foi de 13,5 metros para o calcário e para a aveia.


Centrifugal broadcaster spreaders have been a breakthrough technology in the application of solid materials in agriculture because they have a high performance in field operations and are able to apply a broad range of rates. However, this equipment has some disadvantages, such as the difficulty in homogenously applying the material although adjusting is a relatively simple task. The objective of this study was to compare treatments of operational adjustments in order to balance and uniformize the transversal pattern of distribution, aiming a higher field operational capacity, for different solid products. The machine evaluated was a centrifugal broadcaster for solid material. Results showed that medium and high speeds of the conveying chain for lime distribution and the low speed for oat distribution give a large and enough sufficient range of application rate by varying the opening of the metering device. Increasing the flow and advancing the impellers position gave a higher field operational capacity because of the possibility of a larger effective width as well as a higher travel speed. The maximum application width recommended is 13.5 meters for both lime and oat.

SELECTION OF CITATIONS
SEARCH DETAIL