1.
Int. braz. j. urol ; 37(5): 630-635, Sept.-Oct. 2011. ilus
Article in English | LILACS | ID: lil-608132

ABSTRACT

INTRODUCTION: Recent research on vasectomy shows that combining cautery and fascial interposition (FI) achieves the most effective occlusion of the vas and minimizes the risk of failure. We present a technique that combines cautery and FI and is suitable for low-resource settings. SURGICAL TECHNIQUE: The surgical technique consists of 1) exposing the vas with the no-scalpel approach; 2) cauterizing the epithelium of lumen of the vas using a portable battery-powered cautery device; 3) performing FI by grasping internal spermatic fascia and applying a free tie with suture material on the fascia to cover the prostatic stump of the vas and separate the two ends of the cut vas; and 4) excising a small 0.5 to 1 cm of the testicular stump. COMMENTS: To maximize vasectomy effectiveness, vasectomy providers should consider learning thermal cautery and FI to occlude vas deferens.


Subject(s)
Humans , Male , Cautery/methods , Vas Deferens/surgery , Vasectomy/methods , Fascia , Ligation , Medical Illustration , Treatment Failure , Vasectomy/instrumentation
SELECTION OF CITATIONS