Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 236
Filter
1.
Braz. dent. sci ; 27(1): 1-11, 2024. tab
Article in English | LILACS, BBO | ID: biblio-1537767

ABSTRACT

Objective: This systematic review aims to compare the clinical longevity of metallic and fiberglass intraradicular posts in teeth with severely compromised crowns, utilizing randomized clinical trials and case reports published in the last eleven years. Material and Methods: The research was conducted on PubMed, Medline, Lilacs, and BBO databases using the first search strategy with the descriptors 'dental posts,' 'longevity,' 'fiberglass-reinforced posts' or 'metallic posts.' The second search strategy involved analyzing the references of articles identified by the first search. Both studies were carried out with stringent inclusion and exclusion criteria. Results: No statistically significant and clinically relevant differences in longevity were observed between metallic and fiberglass posts. Conclusion: The clinical success and durability of the restorative procedure using intraradicular posts primarily depend on the remaining amount around the post (ferrule), the type and position of the tooth in the arch (impacting the masticatory forces exerted on the restored tooth), and the correct application of the cementation technique. It is noteworthy that fiberglass posts offer substantial advantages by presenting a modulus of elasticity similar to dental structure, ensuring a more homogeneous distribution of masticatory forces and reducing the risk of fractures. These findings have practical implications for material selection in restorative procedures involving intraradicular posts.(AU)


Objetivo: Esta revisão sistemática visa comparar a longevidade clínica de pinos intrarradiculares metálicos e de fibra de vidro em dentes com coroas severamente comprometidas, através de estudos clínicos randomizados e relatos de casos, publicados nos últimos onze anos. Material e Métodos: A pesquisa foi conduzida nas bases de dados PubMed, Medline, Lilacs e BBO, utilizando a primeira estratégia de busca com os s 'pinos dentais' e 'longevidade' e 'pinos reforçados com fibra de vidro' ou 'pinos metálicos'. A segunda estratégia de busca consistiu na análise das referências dos artigos identificados pela primeira estratégia. Ambos os estudos foram delineados com critérios rigorosos de inclusão e exclusão. Resultados: Não se constataram diferenças estatisticamente significativas e clinicamente relevantes na longevidade entre pinos metálicos e de fibra de vidro. Conclusão: O êxito clínico e a durabilidade do procedimento restaurador empregando pinos intrarradiculares dependem primordialmente da quantidade de remanescente ao redor do pino (férula), do tipo e posição do dente na arcada (o que impacta nas forças mastigatórias exercidas sobre o dente restaurado) e da aplicação correta da técnica de cimentação.Destaca-se que o pino de fibra de vidro oferece vantagens substanciais ao apresentar módulo de elasticidade similar à estrutura dentária, assegurando uma distribuição mais homogênea das forças mastigatórias e reduzindo o risco de fraturas (AU)


Subject(s)
Dental Materials , Dental Pins
2.
Rev. Odontol. Araçatuba (Impr.) ; 44(1): 9-16, jan.-abr. 2023. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1427810

ABSTRACT

As lesões dentárias traumáticas são um problema de saúde pública mundial, dentre as quais a fratura dentária é a de maior ocorrência, envolvendo principalmente os dentes anteriores. A abordagem de grandes fraturas anteriores é um desafio para cirurgiões dentistas de qualquer nível pois, além da função, afetam diretamente a estética do paciente, fazendo-se necessário um planejamento que envolva diferentes especialidades na odontologia. Objetivo: Relatar um caso clínico de reabilitação funcional e estética de fratura dentária nos incisivos centrais superiores envolvendo tratamento endodôntico, instalação de pino de fibra de vidro e restauração direta em resina composta. Relato de Caso: O paciente de 17 anos sofreu fratura nos incisivos centrais superiores causada por uma queda de bicicleta. Devido à busca tardia por tratamento o elemento 21 foi diagnosticado com necrose pulpar e, portanto, foi submetido à tratamento endodôntico pela Técnica Crown Down e reabilitação com pino de fibra de vidro Splendor-SAP. Posteriormente, os elementos 11 e 21 foram restaurados com facetas diretas em resina composta pela técnica incremental. Conclusão: A reabilitação com instalação de pino de fibra de vidro associada à técnica de estratificação incremental em resina composta se mostra como uma boa opção para reabilitação estética pois permite dar forma anatômica ao dente com riqueza de detalhes na estratificação da dentina e esmalte, além de máxima preservação da estrutura dental. Os resultados obtidos reforçam o sucesso estético e funcional com significativo impacto na qualidade de vida do paciente(AU)


Traumatic dental injuries are a worldwide public health problem, among which dental fractures are the most frequent, mainly involving the anterior teeth. The approach of large anterior fractures is a challenge for dental surgeons of any level because, in addition to function, they directly affect the patient's esthetics, requiring a plan that involves different specialties in dentistry. Objective: Report a clinical case of functional and aesthetic rehabilitation of dental fractures in maxillary central incisors involving endodontic treatment, installation of a fiberglass post and direct restoration in composite resin. Case Report: The 17-year-old patient suffered a fracture in the upper central incisors caused by a fall from a bicycle. Due to the late search for treatment, element 21 was diagnosed with pulp necrosis and, therefore, underwent endodontic treatment using the Crown Down Technique and rehabilitation with a Splendor-SAP fiberglass pin. Later, elements 11 and 21 were restored with direct veneers in composite resin using the incremental technique. Conclusion: Rehabilitation with the installation of a fiberglass post associated with the incremental layering technique in composite resin is a good option for aesthetic rehabilitation as it allows the anatomical shape of the tooth with rich details in the layering of dentin and enamel, in addition to maximum preservation of the tooth structure. The results obtained reinforce the aesthetic and functional success with a significant impact on the patient's quality of life(AU)


Subject(s)
Humans , Male , Adolescent , Tooth Injuries , Composite Resins , Dental Restoration, Permanent , Esthetics, Dental , Quality of Life , Root Canal Therapy , Dental Pulp Necrosis , Dental Veneers , Incisor
3.
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1436214

ABSTRACT

Introduction: Cerebral Palsy (CP) is characterized by a disorder of posture and movement, commonly leading to disabling orthopedic alterations, including muscle shortening, especially in the lower limbs. Stretching methods, performed gradually, are necessary to delay the impairment in function from muscle shortening. The use of serial casting aims to promote proper alignment, and an ideal and stable support base, in addition to better bone and joint health, leading to better posture, mobility, muscle function, and, subsequently, increased fitness and health.Objective: evaluate range of motion, postural control, and motor performance in children with CP, using serial casting, as well as to measure its effect on fitness through the autonomic nervous system (ANS).Methods: Sixty children and adolescents with CP, of both sexes, 3 to 12 years of age, will be divided into three groups: Groups A, B, and C, with 20 individuals each. Group A will use serial casting, Group B will use the orthosis continuously (with removal only allowed for bathing), and Group C will use the orthosis in their daily routine. Range of motion of the ankle of first and second resistance levels (R1 and R2), gross motor function measure (GMFM), and balance (measured by BERG scale) will be used in the initial and final assessments, and after 6 months and one year of follow-up. Timed-up-and-go (TUG), load distribution (baropodometry), motor performance measured through a real basketball game and the virtual MoveHero game, analysis of body angulation with "mydartfish", and cardiac autonomic modulation through heart rate variability will be assessed in three different situations: barefoot, with orthosis, and with casting.Conclusion: Serial casting demonstrates the potential to produce positive results in the treatment of individuals with CP regarding better alignment, with consequent motor and autonomic improvement.

4.
RGO (Porto Alegre) ; 71: e20230009, 2023. graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1431163

ABSTRACT

ABSTRACT The aim of this study was to report the clinical case of an 8-year-old male patient seen at the Pediatric Dentistry outpatient clinic at the Universidade Federal do Paraná, Brazil, diagnosed with molar-incisor hypomineralization (MIH) after presenting with pain in teeth 16, 36, and 46, which had extensive atypical cavities and opacities on the adjacent enamel. A diagnostic wax-up of affected teeth was performed for manufacture of silicone occlusal matrix. Encapsulated high-viscosity glass ionomer cement was handled and inserted into the occlusal matrix which was fitted onto the teeth by slight finger pressure. After setting time, excess of material was removed, and occlusion was checked. A flowable resin coating material was applied, and the restorations were finished. Six months later, the restorations performed for treatment of the severe MIH lesions proved to be efficient, lowering the sensitivity reported by the patient, reshaping the teeth, improving their function, and refining dental esthetics.


RESUMO O objetivo deste estudo foi relatar um caso clínico de um paciente com diagnóstico de Hipomineralização de Molares e Incisivos (HMI). Paciente do sexo masculino, de 8 anos de idade, compareceu à clínica de Odontopediatria da Universidade Federal do Paraná com queixa de dor nos dentes 16, 36 e 46 - os quais apresentavam extensas cavitações atípicas com opacidades no esmalte adjacente. O enceramento diagnóstico dos dentes afetados foi realizado para a confecção das matrizes oclusais de silicone. Cimento ionômero de vidro de alta viscosidade encapsulado foi manipulado e inserido na matriz oclusal, a qual foi encaixada sobre os dentes, exercendo-se leve pressão digital. Após a presa do material os excessos foram removidos e a oclusão foi checada. Aplicou-se uma camada de resina fluída de cobertura e as restaurações foram finalizadas. Após seis meses, as restaurações realizadas para tratar as lesões severas de HMI mostraram-se eficazes, reduzindo a sensibilidade relatada pelo paciente, além de reestabelecerem a anatomia, função e estética dentária.

5.
Acta ortop. bras ; 31(1): e258453, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1419968

ABSTRACT

ABSTRACT Objective: Evaluating the clinical results of bioactive glass S53P4 putty for the treatment of cavitary chronic osteomyelitis. Methods: Retrospective observational study, including patients of any age with clinical and radiological diagnosis of chronic osteomyelitis, who underwent surgical debridement and implantation of bioactive glass S53P4 putty (BonAlive® Putty, Turku, Finland). Patients who underwent any plastic surgery on the soft tissues of the affected site or had segmental bone lesions or septic arthritis were excluded. Statistical analysis was performed using Excel®. Demographic data, as well as data on the lesion, treatment, and follow-up, were collected. Outcomes were classified as "disease-free survival," "failure," or "indefinite." Results: This study included 31 patients, of which 71% were men and had with a mean age of 53.6 years (SD ± 24.2). In total, 84% were followed-up for at least 12 months and 67.7% had comorbidities. We prescribed combination antibiotic therapy for 64.5% of patients. In 47.1%, Staphylococcus aureus was isolated. Finally, we classified 90.3% of cases as "disease-free survival" and 9.7% as "indefinite." Conclusion: Bioactive glass S53P4 putty is safe and effective to treat cavitary chronic osteomyelitis, including infections by resistant pathogens, such as methicillin-resistant S. aureus. Level of Evidence IV, Case Series.


RESUMO Objetivo: Avaliar a atividade do vidro bioativo S53P4 em pasta no tratamento de osteomielite crônica. Métodos: Estudo observacional retrospectivo, com inclusão de indivíduos de qualquer idade com diagnóstico clínico e radiológico de osteomielite que realizaram tratamento cirúrgico com limpeza e desbridamento, seguido do preenchimento da cavidade com biovidro S53P4 em pasta (BonAlive ® Putty, Turku, Finland). Foram excluídos pacientes submetidos a procedimentos de cirurgia plástica nos tecidos moles do local afetado, com lesões ósseas segmentares e com presença de artrite séptica. A análise estatística foi realizada em Excel ® . Foram coletados dados demográficos, sobre a lesão, o tratamento e o acompanhamento. O desfecho foi classificado em "sobrevida livre de doença", "falha" ou "indeterminado". Resultados: Dos 31 pacientes analisados, 71% eram homens, com idade média de 53,6 anos (DP ± 24,26). Do total, 84% foram acompanhados por no mínimo 12 meses, e 67,7% apresentaram comorbidades. A terapia antibiótica combinada foi realizada em 64,5% dos pacientes, sendo o patógeno mais frequente o Staphylococcus aureus (47,1%). Ao final, 90,3% dos pacientes obtiveram "sobrevida livre de doenças" e 9,7% foram considerados "indeterminados". Conclusão: O vidro bioativo S53P4 em pasta é seguro e eficaz no tratamento da osteomielite cavitária e de infecções por patógenos resistentes, incluindo o S. aureus multirresistente. Nível de Evidência IV, Série de Casos.

6.
Braz. dent. sci ; 26(3): 1-16, 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1442916

ABSTRACT

Statement of problem: the bond strength between adhesive cement and root dentin can be affected by irrigation protocols. Purpose: therefore, the objective of this systematic review was to answer the following question: Do irrigation solutions used during root canal instrumentation influence the adhesion of glass fiber posts to root dentin? Material and Methods: this study followed the recommendations of PRISMA 2020 for writing. PubMed, Scopus, Web of Science, and LILACS databases were searched for articles published until 26 January, 2022. Grey literature and a manual search were also performed. The inclusion criteria were based on the PICO strategy: permanent human or animal teeth (P), which were irrigated during root canal instrumentation with endodontic substances (I) and compared to irrigation with sodium hypochlorite at various concentrations (C) to analyze the bond strength of glass fiber posts (O). Two authors independently performed data extraction and the risk of bias. Results: eight articles were included. Four articles were classified as having a high risk of bias, where the others as medium risk. Studies have reported conflicting results regarding the influence of irrigating solutions and the different concentrations of sodium hypochlorite on the adhesion of glass fiber posts to root dentin. Conclusion: the heterogeneity between studies did not allow the conclusion of a true estimate regarding this topic, and further well-designed studies are needed to clarify this issue. Register: CRD42020221835. (AU)


Definição do problema: a resistência de união entre o cimento adesivo e a dentina radicular pode ser afetada pelos protocolos de irrigação. Objetivo: portanto, o objetivo desta revisão sistemática foi responder à seguinte questão: As soluções de irrigação usadas durante a instrumentação do canal radicular influenciam a adesão de pinos de fibra de vidro à dentina radicular? Material e Métodos: este estudo seguiu as recomendações do PRISMA 2020 para sua redação. As bases de dados PubMed, Scopus, Web of Science e LILACS foram pesquisadas para artigos publicados até 26 de janeiro de 2022. A literatura cinza e uma pesquisa manual também foram realizadas. Os critérios de inclusão foram baseados na estratégia PICO: dentes humanos ou animais permanentes (P), que foram irrigados durante a instrumentação do canal radicular com substâncias endodônticas (I) e comparados à irrigação com hipoclorito de sódio em várias concentrações (C) para analisar a resistência de união de pinos de fibra de vidro (O). Dois autores realizaram independentemente a extração de dados e o risco de viés. Resultados:oito artigos foram incluídos. Quatro artigos foram classificados como de alto riscode viés, enquanto os demais como de médio risco. Estudos relataram resultados conflitantes sobre a influência de soluções irrigadoras e as diferentes concentrações de hipoclorito de sódio na adesão de pinos de fibra de vidro à dentina radicular. Conclusão: a heterogeneidade entre os estudos não permitiu a conclusão de uma estimativa verdadeira sobre este tópico, sendo necessários mais estudos bem delineados para esclarecer esta questão. Registo: CRD42020221835 (AU)


Subject(s)
Root Canal Irrigants , Casts, Surgical , Shear Strength , Dentin
7.
São José dos Campos; s.n; 2023. 79 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1443514

ABSTRACT

O objetivo deste estudo foi desenvolver e avaliar um adesivo resinoso modificado com a incorporação de partículas de vidro bioativas (SCHOTT Bioactive Glass) em diferentes concentrações. Foram avaliados a resistência ao cisalhamento (RU), o índice de remanescente dentário (IRA), o grau de conversão (GC) e a liberação de cálcio. Foram utilizados 50 incisivos bovinos que foram fixados, através de suas raízes, em um molde de PVC, com resina acrílica autopolimerizável. As amostras foram alocadas em 5 grupos (n=10): TXT - Adesivo Transbond XT (3M Unitek, Monrovia, CA, EUA) sem adição de partículas de vidro bioativas, TXT20, TXT30, TXT50 ­ Adesivo Transbond XT acrescido respectivamente de 20%, 30% e 50% de partículas de vidro bioativas e SH - Adesivo resinoso FL BOND ll (SHOFU Inc.) com biomaterial SPRG. As amostras receberam uma profilaxia com pedra pomes e condicionamento com ácido fosfórico à 37%. Em seguida foi aplicada uma fina camada do sistema adesivo indicado na face vestibular dos incisivos bovinos, em todos os grupos e fotopolimerizado por 20 segundos, utilizando-se um fotopolimerizador RADII-Cal (SDI, Victoria, Austrália). Depois foi aplicada uma pequena quantidade de pasta resinosa fotopolimerizável Transbond XT (3M Unitek, Monrovia, CA, EUA) sobre a superfície dos bráquetes autoligados (MORELLI, Sorocaba, São Paulo, Brasil) e estes foram devidamente colados na face vestibular, no centro da coroa clínica do incisivo bovino e fotopolimerizado por 20 segundos, em cada face. Posteriormente as amostras foram submetidas ao teste de resistência ao cisalhamento. O índice de remanescente adesivo foi avaliado em estereomicroscópio DISCOVERY V20 (ZEISS). Os adesivos resinosos foram submetidos ao teste de grau de conversão e liberação de cálcio. Os dados foram inicialmente submetidos ao teste de normalidade e depois submetidos ao teste de ANOVA um fator, seguido do teste de Tukey para análise de comparações múltiplas, com nível de significância de 0,05. De acordo com os resultados obtidos na resistência de união ao cisalhamento (MPa±Dp) a maior média foi observada no grupo TXT 19,50±1,40A, seguida do grupo TXT20 18,22±1,04AB, seguida do grupo SH 17,62±1,45B, seguida do grupo TXT30 14,48±1,46C e a menor média TXT50 14,13±1,02C. No grau de conversão a maior média foi observada no grupo TXT20 73,02±3,33A que foi estatisticamente semelhante ao grupo SH 68,50±1,09A, seguida do grupo TXT 60,28±1,06B e TXT30 58,84±4,06B e a menor média foi do grupo TXT50 40,67±1,21C.Para a liberação de cálcio a maior média foi TXT50 2,23±0,11D, seguida por TXT30 0,74±0,00C, TXT20 0,55±0,00B, SH 0,47±0,04B e TXT 0,14±0,00A. Concluiu-se que a incorporação de partículas de vidro bioativas influenciou na resistência de união ao cisalhamento, no grau de conversão e na liberação de cálcio (AU).


The objective of this study was to develop and evaluate a resin adhesive modified with the incorporation of bioactive glass particles (SCHOTT Bioactive Glass) in different concentrations. Shear bond strength (SBS), adhesive remnant index (ARI), degree of conversion (DC) and calcium release were evaluated. Fifty bovine incisors were used, which were fixed through their roots in a PVC mold with self-curing acrylic resin. The samples were allocated into 5 groups (n=10): TXT ­ Transbond XT Adhesive (3M Unitek, Monrovia, CA, USA) without addition of bioactive glass particles, TXT20, TXT30, TXT50 ­ Transbond XT Adhesive rescpectively increased by 20%, 30% and 50% bioactive glass particles and SH ­ FL BOND ll resin adhesive (SHOFU Inc.) with SPRG biomaterial. The samples received prophylaxis with pumice stoe and conditioning with 37% phosphoric acid. Then, a thin layer of the indicated adhesive system was applied to the buccal surface of the bovine incisors, in all groups, and light cured for 20 seconds, using a RADII-Call curing light (SDI, Victoria, Australia). Then, a small amount of Transbond XT light-curing resinous paste (3M Unitek, Monrovia, CA, USA) was applied on the surface of the self-ligating brackets (MORELLI, Sorocaba, São Paulo, Brazil) and these were duly bonded on the buccal surface, in the center of the clinical crown of the bovine incisor and light cured for 20 seconds, on each side. Subsequently, the samples were submitted to the shear bond test. The adhesive remnant index was evaluated using a DISCOVERY V20 stereomicroscope (ZEISS). The resin adhesives were submitted to the degree of conversion and calcium release test. The data were initially submitted to the normality test and then submitted to the one-way ANOVA test, followed by the Tukey test for analysis of multiple comparisons, with a significance level of 0.05. According to the results obtained in the shear bond strength (MPa±Dp), the highest average was observed in the TXT group 19.50±1.40A, followed by the TXT20 group 18.22±1.04AB, followed by the SH group 17.62±1.45B, followed by the TXT30 group 14.48±1.46C and the lowest mean TXT5014.13±1.02C. In the degree of conversion, the highest average was observed in the TXT20 73.02±3.33A group, wich was statiscally like the SH group 68.50±1.09A, followed by the TXT 60.28±1.06B and TXT30 group 58.84±4.06B and the lowest mean was for the TXT50 group 40.67±1.21C. For calcium release, the highest mean was TXT50 2.23±0.11D, followed by TXT30 0.74±0.00C, TXT20 0.55±0.00B, SH 0.47±0.04B and TXT 0.14±0.00A. It was concluded that the incorporation of bioactive glass particles influenced in the shear bond strength, in the degree of conversion and in the release of calcium (AU).


Subject(s)
Animals , Cattle , Orthodontics , Shear Strength
8.
Belo Horizonte; s.n; 2023. 89 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1511443

ABSTRACT

Atualmente, diversos materiais restauradores encontram-se disponíveis para aplicabilidade em Odontopediatria. Os avanços dos materiais restauradores conduzem à necessidade de novos estudos nessa temática. O presente estudo apresenta duas propostas de investigação: 1) Estudo transversal com objetivo de avaliar a preferência de pais/responsáveis e crianças quanto ao emprego do compômero colorido (Twinky Star®, Voco, Alemanha); 2) Estudo bibliométrico altimétrico com objetivo de analisar 50 artigos mais citados referente aos materiais restauradores utilizados em Odontopediatria e o alcance dessa informação científica nas mídias on-line. O estudo transversal envolveu 260 pares de pais/responsáveis e crianças de 5 a 11 anos de idade de dois serviços de saúde da região metropolitana de Belo Horizonte-MG. Exame quanto à cárie dentária foi realizado por examinadora calibrada para o critério da Organização Mundial da Saúde. Um manequim odontológico contendo restaurações com compômeros coloridos e materiais convencionais (resina composta, ionômero de vidro e amálgama) foi apresentado aos participantes do estudo e realizou-se inquérito sobre a preferência dos materiais dentários. O Questionário de Estilo e Dimensões dos Pais (PSDQ) e o Eysenck Personality Questionnaire Junior (EPQ-J) foram aplicados, este último apenas para pais/responsáveis de crianças de 5 e 6 anos de idade. Análises descritivas, bivariadas e regressão multivariada de Poisson foram realizadas. A maioria dos pais/responsáveis (74,2%) preferiu materiais convencionais. A idade da criança (p=0,006), a renda familiar (p= 0,001) e o nível de escolaridade (p< 0,001) associaram se a essa escolha. A análise multivariada demonstrou que crianças menores de 7 anos apresentaram 1,20 vezes maior probabilidade de escolher compômeros coloridos do que seus pares mais velhos (p< 0,001), assim como pais/responsáveis com menos de 11 anos de escolaridade e cujos filhos eram menores de 7 anos apresentaram 2,17 e 1,74 maior probabilidade para escolher compômeros coloridos, respectivamente. Concluiu-se que responsáveis com maior escolaridade apresentaram maior resistência às restaurações coloridas e crianças menores de 7 anos aceitaram melhor este material. O estudo bibliométrico-altimétrico adotou estratégia de busca em três bases (Web of Science, Scopus e Google Scholar), independente da data de publicação. Após seleção dos artigos por um grupo de cinco pesquisadores, em março de 2023, foram incluídos estudos que avaliassem qualquer material restaurador empregado em dentes decíduos e analisados dados referentes ao título, número de citações, país/continente, autoria, periódico, instituição, desenho do estudo, tipo de material restaurador, e escore altimétrico. Os artigos, publicados entre 1991 a 2002, apresentaram variação de citações de 19 a 113. Os autores com maior número de citações foram Qvist V e Teglers PT. O estudo experimental foi o principal delineamento de estudo observado e o cimento de ionomero de vidro foi o material mais reportado. A Europa foi o continente, e o Brasil, o país com maior número de citações. O escore altimétrico esteve presente em 23 artigos, com ênfase para dois artigos (43/6º e 73/7º). Concluiu-se que o cimento de ionômero de vidro foi o material mais estudado. Ficou evidente o distanciamento entre a posição dos trabalhos nas análises bibliométrica e altimétrica, apontando necessidade de disseminação da informação além dos círculos acadêmicos.


Currently, an arsenal of restorative materials is available for applicability in pediatric dentistry. The advances in restorative materials conducted to need for further studies in this thematic. The present study presents two investigation proposals: 1) Cross-sectional study aiming to evaluate the preference of parents and children regarding the use of colored compomer (Twinky Star®, Voco, Germany); 2) Bibliometric-altmetric study aiming to analyze the 50-most cited papers regarding to restorative materials used in pediatric dentistry and the dissemination of scientific information in online media. The cross-sectional study included 260 pairs of caregivers/children aged 5 to 11, in two public health services, in the metropolitan region of Belo Horizonte-MG. Examination for dental caries was performed by an examiner calibrated to the criteria of the World Health Organization. A dental mannequin containing colored compomers restorations and conventional materials (composite resin, glass ionomer cement and dental amalgam) was presented to the population and a survey was conducted about the preference of dental materials. Parents' Style and Dimensions Questionnaire (PSDQ) and Eysenck Personality Questionnaire Junior (EPQ-J) were applied, the last one only for parents/caregivers of children aged 5 to 6. Descriptive, bivariate and Poisson regression analyzes were performed. Most adults (74.2%) preferred conventional materials. Family income (p= 0.001) and education level (p< 0.001) were associated with its choice. Age up to 7 (p< 0.001) associated with children's choice for colored restorations (72.3%). Children younger than 7 had 1.20 higher probability to choose colored compomers than their older pairs, while adults with children younger than 7 and less than 11 years of schooling had 1.74 and 2.17 higher probability to choose colored compomers, respectively. It was concluded that caregivers with higher educational level showed greater resistance to use of colored restorations and children younger than 7 had better acceptance of colored material. The bibliometrics-altmetrics study adopted a search strategy in three databases (Web of Science, Scopus and Google Scholar), independent of the year of publication. After selection of papers by a panel of five researchers, in March 2023, any restorative material used in deciduous teeth was included and data about the title, number of citations, country/continent, authorship, journal, design of the study, type of restorative material, university and altmetrics score were analyzed. The papers, published between 1991 and 2002, ranged from 19 to 113 citations. The authors with the highest number of citations were Qvist V and Teglers PT. The experimental study was the main study design observed. Analyzing the continent and country with the highest number of citations, Europe highlighted and Brazil was predominant. The altmetric score was present in 23 papers, emphasizing two articles (43/6th and 73/7th). It was concluded that glass ionomer cement was the most studied material. A gap between the position of the papers correlating the bibliometrics and altmetrics analyzes was evident, demonstrating the need to disseminate the information beyond academic circles.


Subject(s)
Bibliometrics , Pediatric Dentistry , Compomers , Dental Amalgam , Dental Materials
9.
Rev. Cient. CRO-RJ (Online) ; 7(3): 52-57, Sept. - Dec. 2022.
Article in English | LILACS, BBO | ID: biblio-1437880

ABSTRACT

Objective: this in vitro study compared the adhesive strengths of the resin sealant with the Giomer technology sealant under salivary contamination. Materials and Methods: fifty-two bovine incisors were randomly divided into four groups (n=13): GI, a resin sealant (Fluroshield®) without salivary contamination (control of GII); GII, Fluroshield sealant + salivary contamination; GIII, a Giomer technology sealant (BeautiSealant®) without salivary contamination (control of GIV); and GIV, BeautiSealant® sealant + salivary contamination. In the salivary contamination groups, artificial saliva was used through a pipette, and after 20 s, it was air-dried and the sealant was applied. Shear strength tests were performed using a universal testing machine. One-way ANOVA variance and Tukey's test were used for multiple comparisons. The fracture types were analyzed using a stereomicroscope with 40X magnification. Results: the means and standard deviations (SD) of adhesion for Fluroshield® and BeautiSealant® in the group without salivary contamination were 15.27 (±0.96) and 11.90 (±0.94), and for the group with salivary contamination, 13.14 (±1.03) and 8.95 (±1.33), respectively, indicating a statistically significant difference between GI and GII p=0.020, GIII and GIV p=0.041. Mixed failures were detected in GI (38%), GII (44%), GIII (38%), and GIV (62%). Conclusion: there was a statistically significant decrease in the adhesive strength values in the groups with salivary contamination for both the sealants studied. However, no significant difference was observed between the two sealants when the materials used were compared.


Objetivo: este estudo in vitro comparou as forças adesivas do selante resinoso com o selante da tecnologia Giomer sob contaminação salivar. Materiais e Métodos: cinquenta e dois incisivos bovinos foram divididos aleatoriamente em quatro grupos (n=13): GI, um selante resinoso (Fluroshield®) sem contaminação salivar (controle do GII); GII, selante Fluroshield + contaminação salivar; GIII, um selante com tecnologia Giomer (BeautiSealant®) sem contaminação salivar (controle do GIV); e GIV, selante BeautiSealant® + contaminação salivar. Nos grupos de contaminação salivar, a saliva artificial foi utilizada por meio de uma pipeta e, após 20 s, foi seca ao ar e aplicado o selante. Os testes de resistência ao cisalhamento foram realizados usando uma máquina de teste universal. A variância ANOVA de uma via e o teste de Tukey foram usados para comparações múltiplas. Os tipos de fratura foram analisados em estereomicroscópio com aumento de 40X. Resultados: as médias e desvios padrão (DP) de adesão para Fluroshield® e BeautiSealant® no grupo sem contaminação salivar foram 15,27 (±0,96) e 11,90 (±0,94), e após contaminação salivar foram 13,14 (±1,03) e 8,95 (±1,33), respectivamente, indicando haver diferença estatisticamente significante entre GI e GII p=0.020, GIII e GIV p=0.041. Falhas mistas foram detectadas em GI (38%), GII (44%), GIII (38%) e GIV (62%). Conclusão: houve diminuição estatisticamente significativa dos valores de resistência adesiva nos grupos com contaminação salivar para ambos os selantes estudados. No entanto, não foi observada diferença significativa entre os dois selantes quando comparados os materiais utilizados.


Subject(s)
Pit and Fissure Sealants , Saliva, Artificial , Shear Strength
10.
Odontoestomatol ; 24(39)2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1386403

ABSTRACT

Resumen Introducción: En respuesta a la sensibilidad dentinaria, se han desarrollado múltiples productos, entre ellos, Clinpro XT, barniz de vidrio ionómero modificado con resina fotopolimerizable con flúor, calcio y fosfato. Metodología: Se realizó una revisión sistemática de la literatura. La selección fue en base a título, resumen y texto completo de acuerdo a los criterios de inclusión y exclusión. Resultados: De 299 artículos, fueron seleccionados revisiones sistemáticas, metaanálisis, estudios in vivo e in vitro y 2 encuestas. Discusión: Clinpro XT reduce la permeabilidad dentinaria, ocluye túbulos dentinarios e inhibe su reapertura, aumenta la biodisponibilidad de minerales en saliva y promueve la remineralización del esmalte. Significando una mayor protección del esmalte y dentina de forma inmediata y a largo plazo. Conclusiones: Clinpro XT demostró disminuir la hipersensibilidad dentinaria incluso después 6 meses posterior a su aplicación.


Resumo Introdução: Em resposta à sensibilidade dentinária, foram desenvolvidos múltiplos produtos, incluindo Clinpro XT, um verniz de vidro de ionómero modificado com resina fotopolimerizável com flúor, cálcio, e fosfato. Metodologia: Foi realizada uma revisão sistemática da literatura. A selecção foi baseada no título, resumo e texto completo de acordo com os critérios de inclusão e exclusão. Resultados: De 299 artigos, revisões sistemáticas, meta-análises, estudos in vivo e in vitro e 2 inquéritos foram seleccionados. Discussão: Clinpro XT reduz a permeabilidade da dentina, oclui os túbulos dentinários e inibe a sua reabertura, aumenta a biodisponibilidade dos minerais na saliva e promove a remineralização do esmalte. O que significa uma maior protecção do esmalte e da dentina imediatamente e a longo prazo. Conclusões: Foi demonstrado que o Clinpro XT diminui a hipersensibilidade da dentina mesmo 6 meses após a aplicação.


Abstract Introduction: Multiple products have been developed to treat dentin sensitivity, including Clinpro XT, a lightcuring resinmodified ionomer glass varnish with fluoride, calcium, and phosphate. Methodology: A systematic literature review was conducted. The articles were selected based on title, abstract, and full text according to the inclusion and exclusion criteria. Results: Of 299 articles, systematic reviews, metaanalysis, in vivo and in vitro studies, and 2 surveys were selected. Discussion Clinpro XT reduces dentin permeability, occludes dentin tubules, inhibits their reopening, increases mineral bioavailability in saliva, and promotes enamel remineralization. This entails greater protection of enamel and dentin immediately and in the long term. Conclusions: Clinpro XT was shown to decrease dentin hypersensitivity even six months after application.

11.
RGO (Porto Alegre) ; 70: e20220013, 2022. tab
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1376097

ABSTRACT

ABSTRACT Objective: To identify the diametral tensile strength of Brazilian brands of conventional glass ionomer cements (GIC) when modified powder ratio in their composition compared to each other, and with high viscosity glass ionomer cement for Atraumatic Restorative Treatment (ART). Methods: Experimental study with five groups (n=10 each) and specimens (2.5 mm in height and 5.0 mm in diameter), considering G1 (Maxxion R-MR), G2 (Vidrion R-VR) and G3 Vitro molar (VM-control) according to manufacturer recommending powder/liquid (1:1), G4 (MR) and G5 (VR) plus powder (2:1). The specimens were stored in an oven at 37 ± 1 ° C for 1 day. Diametral Tensile Test was performed by the Instron model 4444. Means differences were tested by Student´s T-Test (α = 5%). Results: There significant differences were in the means (standard deviation) of diametral tensile strength of MR (1:1) 4.24 (±1.47) and MR (2:1), 5.74 (±1.51) (p=0.039) and VR (1:1) 4.50 (±1.27) and VR (2:1) 6.20 (±1.89) (p=0.029). When comparing MR and VR (2:1) with MV (1:1) 4.82 (±1.17), VR 2: 1, 6.20 (±1.89) showed significant differences (p=0.0336). Conclusion: There was a significant increase in the means of diametral tensile strength of Brazilian brands conventional GICs when powder increment, approaching the performance observed by the high viscosity GIC.


RESUMO Objetivo: Identificar a resistência à tração diametral de marcas nacionais de cimentos de ionômero de vidro (CIV) convencionais quando acrescidos de pó em sua composição comparados entre si e com cimento de ionômero de vidro de alta viscosidade para Tratamento Restaurador Atraumático (TRA). Métodos: Pesquisa experimental com cinco grupos (n=10 cada) e confeccionados corpos de prova (2,5 mm de altura e 5,0 mm de diâmetro), considerando G1 (Maxxion R/FGM-MR), G2 (Vidrion R/SS White-VR) e G3 Vitro molar (DFL-VM-controle) manipulados segundo fabricante pó/líquido (1:1), G4 (MR) e G5 (VR) acrescidos de pó (2:1). Os espécimes foram armazenados em estufa a 37 ± 1° C por 1 dia. Teste de Tração Diametral foi realizado pelo equipamento Instron modelo 4444. As diferenças das médias foram testadas pelo Test T de Student (α=5%). Resultados: Foram encontradas diferenças significativas das médias (desvio-padrão) de resistência à tração diametral de MR (1:1) 4,24 (±1,47) e MR (2:1), 5,74(±1,51) (p=0,039) e VR (1:1) 4,50 (±1,27) e VR (2:1) 6,20(± 1,89) (p=0,029). Quando da comparação entre MR e VR (2:1) com VM (1:1) 4,82(±1,17), VR 2:1, 6,20 (±1,89) apresentou média superior e significante (p=0,0336). Conclusão: Observou-se aumento significativo nas médias de resistência mecânica à tração diametral dos CIVs convencionais nacionais a partir do incremento de pó, aproximando-se do desempenho observado pelo CIV de alta viscosidade.

12.
Rev. odontol. UNESP (Online) ; 51: e20220005, 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1377171

ABSTRACT

Introduction: Some experimental models have been used to evaluate the use of biomaterials in bone regeneration. Among them are the critical size defects (CSD) created in rat calvaria. An experimental model has been described in the literature, in which "L" markings are performed on the margins of the bone defects in order to assist in the precise identification of these defects during laboratory processing and analysis of the results. In the proposed model, the "L" markings are filled with amalgam. Objective: The purpose of the present study was to evaluate the amalgam replacement of an experimental bony defect model in rat calvaria by heated or unheated glass ionomer. Material and method: 24 rats were used. A 5 mm CSD was created at each animal calvaria. Two "L" shaped markings were made 2 mm from the margins of the bone defect, filled with amalgam (Group AM), heated glass ionomer cement (Group GIh) or not (Group GI). The animals were euthanized 15 days postoperatively. The areas of the surgical defect and the L-shaped marking were histomorphometrically analyzed and the data were analyzed statistically (p <0.05). Result: There were no significant clinical, histological or methodological differences among the experimental groups. Conclusion: It can be concluded that GI can replace AM in the proposed experimental model and GI heating did not promote additional benefits.


Introdução: Alguns modelos experimentais têm sido usados para avaliar o uso de biomateriais na regeneração óssea. Entre eles estão os defeitos de tamanho crítico (DTC) criados em calvárias de ratos. Um modelo experimental foi descrito na literatura onde marcações em L são realizadas nas margens do defeito ósseo para auxiliar na identificação precisa desses defeitos durante o processamento laboratorial e análise dos resultados. No modelo experimental proposto, as marcações em "L" são preenchidas com amálgama. Objetivo: Avaliar a substituição do amálgama por ionômero de vidro aquecido ou não em um modelo experimental para identificação de defeito ósseo criado em calvária de ratos. Material e método: Foram utilizados 24 ratos. Um DTC de 5 mm de diâmetro foi criado na calvária de cada animal. Duas marcações em "L" foram realizadas a 2 mm das margens do defeito ósseo, preenchidas com amálgama (Grupo AM), ionômero de vidro aquecido (Grupo CIVaq) ou não (Grupo CIV). Os animais foram eutanasiados aos 15 dias pós-operatórios. A área do defeito cirúrgico e das marcações em "L" foram histomorfometricamente avaliadas e os dados estatisticamente analisados (p<0,05). Resultado: Não houve diferença estatisticamente significativa entre os grupos experimentais para as análises metodológicas, clínicas ou histomorfométrica realizadas. Conclusão: Dentro dos limites deste estudo, pode-se concluir que CIV pode substituir o AM no modelo experimental proposto e o aquecimento do CIV não promoveu benefícios adicionais.


Subject(s)
Rats , Skull , Biocompatible Materials , Bone Regeneration , Dental Amalgam , Glass Ionomer Cements , Mathematical Computing , Analysis of Variance
13.
Braz. dent. sci ; 25(4): 1-9, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1410481

ABSTRACT

Objective: The aim was to evaluate the influence of fluoride-releasing restorative materials in enamel and dentin microhardness. Material and Methods: 40 blocks (5x5x3 mm) from cervical third of human molars received a cavity preparation between the enamel and dentin, and the restorations were subjected to in vitro caries model. Specimens were randomly restored with (n=10): conventional glass ionomer cement (Ketac Cem, 3M ESPE); polyacid-modified composite resin (Ionoseal, VOCO); resin-modified glass ionomer cement (Ionofast, Biodinâmica); or microhybrid composite resin (Filtek Z250, 3M ESPE). The specimens were sectioned longitudinally and enamel and dentin Knoop microhardness were determined at different distances from the restorative material (100, 200 and 300 µm) and depth of surface (20, 40 and 60 µm). The data were submitted to three-way repeated measures ANOVA and Tukey ́s test ( α =0.05). Results: For enamel, the double interactions between material x distance and material x depth were statistically significant. In all depths and distances, the highest values of enamel microhardness were observed for Ketac Cem. In dentin, the materials differed statistically from each other, and Ionoseal obtained higher microhardness values than those found in Ionofast. Conclusion: Conventional glass ionomer cement is more effective in preventing enamel demineralization around restoration followed by the polyacid-modified composite resin. In dentin, the polyacid-modified composite resin obtained better performance than resin-modified glass ionomer cement. (AU)


Objetivo: O objetivo foi avaliar a influência de materiais restauradores liberadores de flúor na microdureza do esmalte e da dentina. Material e Métodos: 40 blocos (5x5x3 mm) do terço cervical de molares humanos receberam preparo cavitário entre esmalte e dentina, e após a restauração foram submetidas a um modelo in vitro de cárie. As amostras foram restauradas aleatoriamente com (n=10): cimento de ionômero de vidro convencional (Ketac Cem, 3M ESPE); resina composta modificada por poliácidos (Ionoseal, VOCO); cimento de ionômero de vidro modificado por resina (Ionofast, Biodinâmica); ou resina composta microhíbrida (Filtek Z250, 3M ESPE). As amostras foram seccionadas longitudinalmente e a microdureza Knoop de esmalte e dentina foi determinada em diferentes distâncias do material restaurador (100, 200 e 300 µm) e profundidade de superfície (20, 40 e 60 µm). Os dados foram submetidos à ANOVA para medidas repetidas de três fatores e teste de Tukey (α =0,05). Resultados: Para o esmalte, as duplas interações entre material x distância e material x profundidade foram estatisticamente significativas. Em todas as profundidades e distâncias, os maiores valores de microdureza do esmalte foram observados para o Ketac Cem. Na dentina, Ionoseal obteve valores de microdureza superiores aos encontrados no Ionofast. Conclusão:O cimento de ionômero de vidro convencional é mais eficaz na prevenção da desmineralização do esmalte ao redor da restauração, seguido pela resina composta modificada por poliácidos. Na dentina, a resina composta modificada por poliácidos obteve melhor desempenho que o cimento de ionômero de vidro modificado por resina. (AU)


Subject(s)
Composite Resins , Compomers , Dental Caries , Glass Ionomer Cements , Hardness Tests
14.
Arq. odontol ; 58: 97-108, 2022.
Article in Portuguese | LILACS, BBO | ID: biblio-1411753

ABSTRACT

Objetivo: Esta revisão de escopo teve como objetivo comparar a taxa de sucesso de restaurações confeccionadas com cinco marcas diferentes de Cimento de Ionômero de Vidro de Alta Viscosidade (CIVAV), referência no Tratamento Restaurador Atraumático (Atraumatic Restorative Treatment-ART).Métodos: Buscas no PubMed, Scopus e Web of Science foram feitas. Buscas no OpenGrey e no Google Scholar também foram feitas. Critérios de inclusão foram estudos (ensaios clínicos e estudos de acompanhamento) que avaliavam a taxa de sucesso de restaurações confeccionadas com CIVAV. Não houve restrição de idioma ou data. Título/resumo e texto completo das referências encontradas foram avaliados por dois autores. Referências que preencheram os critérios de inclusão foram selecionadas. Extração de dados foi feita. Modelos de regressão de Cox foram idealizados para comparação da probabilidade de sucesso das restaurações com diferentes tipos de CIVAV. Os resultados foram relatados em razão das chances (RC) e intervalos de confiança (IC). Análises de Kaplan Meyer foram feitas para o cálculo da probabilidade de sucesso de restaurações com CIVAV. Resultados: Nove artigos avaliando o ChemFil Rock, ChemFlex, Equia Fil, Ketac Molar ou Fuji IX foram incluídos. Restaurações com cimentos de ionômero de vidro Fuji IX (RC = 3,51; IC = 1,96 ­ 6,28), Ketac Molar (RC = 4,01; IC = 2,40-6,68) e ChemFlex (RC = 4,20; IC = 1,01-17,66) apresentaram uma taxa de sucesso significativamente maior do que aquelas com ChemFil Rock. EquiaFil alcançou a segunda menor eficácia, ligeiramente maior que o ChemFil Rock. Conclusão:Restaurações com Fuji IX, Ketac Molar e ChemFlex apresentaram altas taxas de sucesso ao longo do tempo de avaliação do ART.


Aim: This scoping review aimed to compare the success rate of restorations using five different brands of High Viscosity Glass Ionomer Cement (HVGIC), reference material in Atraumatic Restorative Treatment (ART). Methods: Searches were carried out in PubMed, Scopus, and Web of Science. OpenGrey and Google Scholar searches were also performed. Inclusion criteria were studies (clinical trials and follow-up studies) that evaluated the success of restorations using HVGIC. Title, abstract, and full text of the references were evaluated by two authors. Articles that met the inclusion criteria were included. Data extraction was performed. Cox regression models were created to compare the success rate of restorations produced with different types of HVGIC. The results were reported as odds ratio (OR) and confidence intervals (CI). Kaplan Meyer analyses were performed to calculate the HVGIC restorations' probability of success.Results: Nine articles evaluating ChemFil Rock, ChemFlex, Equia Fil, Ketac Molar, or Fuji IX were included. Restorations with glass ionomer cements Fuji IX (OR = 3.51; CI = 1.96 - 6.28), Ketac Molar (OR = 4.01; CI = 2.40-6.68), and ChemFlex (OR = 4.20; CI = 1.01-17.66) had a significantly higher success rate than those with ChemFil Rock. EquiaFil achieved the second lowest efficacy, slightly higher than ChemFil Rock.Conclusion: Restorations with Fuji IX, Ketac Molar, and ChemFlex showed high success rates over the ART evaluation time.


Subject(s)
Survival Analysis , Dental Atraumatic Restorative Treatment , Glass Ionomer Cements
15.
São José dos Campos; s.n; 2022. 160 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1401290

ABSTRACT

O objetivo do ensaio clínico foi avaliar o desempenho clínico de 2 materiais bioativos (Cention N e EQUIA Forte) em comparação a resina composta. O estudo in vitro teve como objetivo avaliar o desenvolvimento de lesões de cárie induzida por desafio cariogênico bacteriano na margem de restaurações em esmalte e dentina com Cention N com e sem adesivo, EQUIA Forte e resina composta. A revisão sistemática teve como objetivo responder a seguinte pergunta: A avaliação clínica de restaurações em dentes permanentes com materiais bioativos evidencia maior sucesso do que restaurações com materiais não bioativos? Para o estudo clínico foram selecionados 120 participantes aleatoriamente divididos em 3 grupos (n=40), TC: Tetric N-Ceram, EF: EQUIA Forte, CN: Cention N. O preenchimento das cavidades foi realizado seguindo as indicações do fabricante. Foi utilizado o dispositivo de fluorescência DIAGNOdentTM Pen para avaliação da recorrência de cárie. No estudo in vitro foram confeccionados 100 espécimes a partir de dentes bovinos. Foram divididos em 5 grupos (n=20) metade em esmalte e metade em dentina: Cention N sem adesivo (CN), Cention N com adesivo (CA), EQUIA Forte (EF); Tetric N-Ceram (TC); e sem restauração (SR). Foram submetidos a envelhecimento térmico; leitura de microdureza Knoop (KHN) inicial, esterilizados e expostos a um desafio cariogênico com Streptococcus mutans por 28 dias. Lesões de cárie artificial foi quantificado por meio de KHN superficial e de subsuperfície, e análise com microscopia de luz polarizada. Os dados foram submetidos a ANOVA 1 fator e teste Tukey no esmalte e teste de Kruskal-Wallis na dentina. Em esmalte os grupos EF, CN, CA apresentaram menor porcentagem de perda da microdureza (%PMS) 57,85%, 63,88% e 66,65% respectivamente. Na dentina, EF, CN e CA apresentaram menores valores de %PMD sendo 31,7%, 34,1% e 40,8% respectivamente. Os valores mais altos de %PMS foram registrados para os grupos TC e SR tanto na dentina como no esmalte. Na revisão sistemática, com base na pergunta de pesquisa e estratégia PICO: P- Dentes permanentes, I- Restaurações (classe I, classe II, classe III, classe V) com materiais bioativos, C- Restauração com materiais não bioativos, O- Retenção; foi traçada a estratégia de busca. Após a obtenção dos estudos eles foram analisados por dois revisores independentes. No total foram 27 ensaios clínicos randomizados, com acompanhamento mínimo de 2 anos, foram os qualificados para realizar a revisão e meta-análise em rede. Os resultados de meta-análise em rede mostraram que em cavidades classe III cimento de ionômero de vidro modificado (CIV modificado), foi significativamente mais propenso a falhas do que a resina composta (RC), em restaurações classe I e II, o compômero foi significativamente mais propenso a falhas do que a RC e em restaurações classe V o cimento de ionômero convencional (CIV convencional) foi significativamente mais propenso a falhas do que o CIV modificado. No estudo in vitro foi evidente o maior potencial de inibição da desmineralização dos materiais bioativos. Na revisão sistemática ficou evidente que a maioria de materiais bioativos apresentam um bom comportamento, em relação as taxas de retenção e desempenho clínico. (AU)


The objective of the clinical trial was to evaluate the clinical performance of 2 bioactive materials (Cention N and EQUIA Forte) compared to composite resin. The in vitro study aimed to evaluate the development of caries lesions induced by bacterial cariogenic challenge at the margin of enamel and dentin restorations with Cention N with and without adhesive, EQUIA Forte and composite resin. The systematic review aimed to answer the following question: Does the clinical evaluation of restorations in permanent teeth with bioactive materials show greater success than restorations with nonbioactive materials? For the clinical study, 120 participants were randomly selected and divided into 3 groups (n=40), TC: Tetric N-Ceram, EF: EQUIA Forte, CN: Cention N. The filling of the cavities was performed following the manufacturer's instructions. The DIAGNOdentTM Pen fluorescence device was used to assess caries recurrence. In the in vitro study, 100 specimens were made from bovine teeth. They were divided into 5 groups (n=20) half in enamel and half in dentin: Cention N without adhesive (CN), Cention N with adhesive (CA), EQUIA Forte (EF); Tetric N-Ceram (TC); and without restoration (SR). They were subjected to thermal aging; initial Knoop microhardness (KHN) reading, sterilized and exposed to a cariogenic challenge with Streptococcus mutans for 28 days. Artificial caries lesions were quantified using surface and subsurface KHN and analysis with polarized light microscopy. Data were submitted to 1-way ANOVA and Tukey test on enamel and Kruskal-Wallis test on dentin. In enamel, groups EF, CN, CA had the lowest percentage of microhardness loss (%PMS) 57.85%, 63.88% and 66.65% respectively. In dentin, EF, CN and CA presented lower %PMD values, being 31.7%, 34.1% and 40.8% respectively. The highest %PMS values were recorded for the TC and SR groups in both dentin and enamel. In the systematic review, based on the research question and PICO strategy: P- Permanent teeth, I- Restorations (class I, class II, class III, class V) with bioactive materials, C- Restoration with non-bioactive materials, O- Retention; the search strategy was designed. After obtaining the studies, they were analyzed by two independent reviewers. In total, 27 randomized clinical trials, with a minimum followup of 2 years, were qualified to perform the review and network meta-analysis. The results of network meta-analysis showed that in class III cavities modified glass ionomer cement (modified GIC) was significantly more prone to failure than composite resin (RC), in class I and II restorations, the compomer was significantly more prone to failure than RC and in class V restorations the conventional ionomer cement (conventional GIC) was significantly more prone to failure than the modified GIC. In the in vitro study, the greatest potential for inhibiting the demineralization of bioactive materials was evident. In the systematic review it was evident that most bioactive materials have a good behavior in relation to retention rates and clinical performance (AU).


Subject(s)
Animals , Cattle , Analysis of Variance , Composite Resins , Dental Caries , Dental Enamel , Glass Ionomer Cements , In Vitro Techniques
16.
Braz. dent. sci ; 25(2): 1-8, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1370587

ABSTRACT

Objective: Resin-modified glass ionomer (RMGI) cements are among the commonly used restorative materials in low stress-bearing areas and also for temporary restorations. The competition between acid-base reactions and light polymerization reactions in delayed curing of RMGIs can affect their physical and mechanical properties, as well as their degree of conversion. Since solubility, color stability, and opacity are among the main physical properties affecting the durability and clinical service of RMGI restorations, this study aimed to assess the effect of delayed curing on solubility, color stability, and opacity of Fuji II LC RMGI. Material and Methods: This in vitro, experimental study evaluated 80 Fuji II LC RMGI specimens (10 specimens per each in 4 groups) in terms of solubility, color stability, and opacity at 6 months later. Specimens were cured immediately or were cured with 1, 5 and 10 min delay. Results: Maximum solubility and minimum change in opacity and color stability at 6 months were noted in the group with delayed curing by 10 min. A significant difference was noted in the solubility of specimens cured after 10 min and 1 min. Significant differences were also noted in the opacity and color stability of specimens cured after 10 min and all other groups (P < 0.05). Conclusion: Delayed curing by 1 min decreased the solubility of RMGI specimens compared with immediate curing or curing after 5 min. Although this difference did not reach statistical significance. Color stability and changes in opacity are mainly influenced by the acid-base reactions rather than polymerization reactions.(AU)


Objetivo: Cimentos de ionômero de vidro modificado por resina (CIVMR) estão entre os materiais restauradores mais comumente utilizados em áreas de baixa tensão e também para restaurações temporárias. A competição entre reações ácido-base e reações provenientes da fotopolimerização tardia dos CIVRMs podem afetar suas propriedades físicas e mecânicas, bem como seu grau de conversão. Uma vez que a solubilidade, estabilidade de cor e opacidade estão entre as principais propriedades físicas que afetam a durabilidade e o tempo de serviço clinico de restaurações de CIVMR, este estudo teve como objetivo avaliar o efeito da fotopolimerizaçao tardia na solubilidade, estabilidade de cor e opacidade do CIVMR Fuji II LC. Material e Métodos: Este estudo experimental in vitro avaliou 80 espécimes de CIVMR Fuji II LC (4 grupos com 10 espécimes cada) em termos de solubilidade, estabilidade de cor e opacidade apos 6 meses. As amostras foram fotopolimerizadas imediatamente ou com 1, 5 e 10 min de atraso. Resultados: Máxima solubilidade e mínima alteração na opacidade e estabilidade da cor em 6 meses foram observadas no grupo com fotopolimerização tardia em 10 min. Uma diferença significativa foi observada na solubilidade das amostras fotopolimerizadas após 10 min e 1 min. Diferenças significativas também foram observadas na opacidade e estabilidade de cor das amostras fotopolimerizadas após 10 min e em todos os outros grupos (P <0,05). Conclusão: A fotopolimerizaçao tardia em 1 min diminuiu a solubilidade das amostras CIVMR em comparação com a fotopolimerizaçao imediata ou após 5 min. Embora essa diferença não tenha alcançado significância estatística. A estabilidade da cor e as mudanças na opacidade são influenciadas principalmente por reações ácido-base, em vez de reações causadas pela polimerização(AU)


Subject(s)
Solubility , Color , Glass Ionomer Cements
17.
Braz. dent. sci ; 25(4): 1-14, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1395942

ABSTRACT

The current review aimed to compare the mechanical properties and clinical behavior of fiberglass and cast metal posts. It included in-vitro studies, finite element analysis, clinical studies, and systematic reviews that evaluated fiberglass and metal posts with reliable methodologies. The reports in the literature diverge on tooth failure modes and stress distributions in the root according to different posts. Investigations suggest that fiberglass posts are preferable because their elastic modulus is similar to dentin. Other studies mention that the flexibility of fiber posts may damage the interface. The fracture load values of different studies could not be compared. The presence of a ferrule seems beneficial. Cast metal posts provide higher characteristic strength to the set but with more unfavorable failures. Intraradicular posts with a lower elastic modulus produce more stress between the cement layer and dentin. In conclusion, fiberglass and cast metal posts can be used with a ferrule. Cast metal posts seem more appropriate for weakened teeth. The presence of a ferrule benefits the system. Weakened teeth tolerate higher loads when restored with cast metal posts, but when these posts fail, the only solution is tooth extraction. Clinical follow-ups cannot yet detect differences between the survival rates of intraradicular fiberglass and cast metal posts (AU)


O objetivo da presente revisão foi comparar as propriedades mecânicas e o comportamento clínico de pinos de fibra de vidro e núcleos metálicos fundidos. Estudos laboratoriais, analise por elementos finitos, estudos clínicos e revisões sistemáticas que avaliaram pinos de fibra de vidro e metálicos, com metodologia confiável foram selecionados. A literatura mostra-se bastante controversa sobre os modos de falha do dente e a distribuição de tensões na raiz de acordo com diferentes tipos de pinos. Algumas investigações sugerem que pinos de fibra de vidro são preferíveis porque seu módulo de elasticidade é semelhante ao da dentina, enquanto outras mencionam que a flexibilidade do pino de fibra pode ser prejudicial à interface adesiva. Os valores de carga de fratura em diferentes estudos não podem ser comparados. A presença de férula é benéfica. O núcleo metálico fundido resulta em maior resistência característica do conjunto, mas falhas mais desfavoráveis. Também, pinos com menor módulo geram mais tensão entre a camada de cimento e a dentina. Em conclusão, verificou-se que tanto pino de fibra de vidro como núcleo metálico fundido podem ser utilizados quando a férula está presente. Os núcleos metálicos fundidos parecem ser mais indicados para dentes fragilizados. É evidente que a presença de férula é benéfica para o sistema. Dentes fragilizados toleram cargas maiores quando restaurados com núcleos metálicos fundidos; porém, quando falham, a única solução é a extração do dente. Os acompanhamentos clínicos ainda não são capazes de detectar diferença entre as taxas de sobrevivência dos pinos de fibra de vidro e núcleos metálicos (AU)


Subject(s)
Prosthodontics , Dental Prosthesis , Finite Element Analysis , Dental Pins
18.
Braz. dent. sci ; 25(4): 1-7, 2022. tab
Article in English | LILACS, BBO | ID: biblio-1397461

ABSTRACT

Objective: The rough surfaces of removable appliances used in pediatric dentistry or orthodontics, may result in an environment for biofilm accumulation, yielding to enamel demineralization. This study aimed to assess the effects of adding nanoparticles of bioactive glass to polymethylmethacrylate to promote the antibacterial activity in acrylic resins. Material and Methods: Acrylic resin specimens (20x20x1mm3) were prepared by adding 2% or 5% bioactive glass. The specimens in the control group without bioactive glass were prepared from the mixture of acrylic powder containing nanoparticles and liquid monomer (n=10 per group). The antibacterial activity of the specimens against Streptococcus mutans and Lactobacillus acidophilus activity in biofilm was investigated through counting colony forming units (CFU). Data were analyzed using a one-way analysis of variance and Tukey's post hoc tests at the significance level of 0.05. Results: The incorporation of 2% (p=0.001) and 5% (p<0.001) bioactive glass in acrylic resin reduced the metabolic activity and CFU of L. acidophilus. For S.mutans, antimicrobial activity was observed only with the 5% concentration of bioactive glass, and this group was statistically different from the control (p<0.001). When L. acidophilus was exposed to polymethyl methacrylate with 5% bioactive glass, significant decrease was observed compared to the control group (p<0.05). Conclusion: Adding bioactive glass nanoparticles into the acrylic resins used for fabricating removable appliances revealed a greater antibacterial effect against cariogenic bacteria tested (AU)


Objetivo: As superfícies rugosas dos aparelhos removíveis utilizados em Odontopediatria ou Ortodontia, podem resultar em um ambiente para acúmulo de biofilme, cedendo à desmineralização do esmalte. Este estudo teve como objetivo avaliar os efeitos da adição de nanopartículas de vidro bioativo ao polimetilmetacrilato para promover a atividade antibacteriana em resinas acrílicas. Material e Métodos: Amostras de resina acrílica (20x20x1 mm3) foram preparadas pela adição de 2% ou 5% de vidro bioativo. Os corpos de prova do grupo controle sem vidro bioativo foram preparados a partir da mistura de pó acrílico contendo nanopartículas e monômero líquido (n=10 por grupo). A atividade antibacteriana dos espécimes sobre a atividade de Streptococcus mutans e Lactobacillus acidophilus em biofilme foi investigada através da contagem de unidades formadoras de colônias (UFC). Os dados foram analisados por meio de análise de variância unidirecional e testes post hoc de Tukey com nível de significância de 0,05. Resultados: A incorporação de 2% (p=0,001) e 5% (p<0,001) de vidro bioativo em resina acrílica reduziu a atividade metabólica e UFC de L. acidophilus. Para S. mutans, a atividade antimicrobiana foi observada apenas com a concentração de 5% de vidro bioativo, sendo este grupo estatisticamente diferente do controle (p<0,001). Quando L. acidophilus foi exposto ao polimetilmetacrilato com 5% de vidro bioativo, foi observada diminuição significativa em relação ao grupo controle (p<0,05). Conclusão: A adição de nanopartículas de vidro bioativo nas resinas acrílicas utilizadas na fabricação de aparelhos removíveis revelou um maior efeito antibacteriano contra as bactérias cariogênicas testadas(AU)


Subject(s)
Acrylic Resins , Dental Materials , Dentists , Anti-Bacterial Agents
19.
Rev. Ciênc. Plur ; 7(3): 358-367, set. 2021. ilus
Article in English | LILACS, BBO | ID: biblio-1348344

ABSTRACT

Introduction:The aesthetic rehabilitation of endodontically treated teeth depends on the destruction degree of the crown, the bone support, type of prosthesis, andchewing forces. In these cases, indirect restorations with composite resins are an excellent alternative. The indirect composite resins have improved physical and mechanical properties due toincorporatingof inorganic fillersand multifunctional monomers. These components offer a greater bonding strength to the indirect restorations, which is advantageous for further rehabilitations with ceramic crowns. Objective:To present an aesthetic rehabilitation of anterior teeth with indirect composite resin as a feasible and less expensive treatment alternative.Case Report:Upon clinical examination, extensive and deficient restorations were observed in the upper anterior teeth. The proposed treatment plan was the aesthetic rehabilitation of endodontically treated teeth with indirect restorations using ceromer.Conclusions:This treatment represented an excellent alternative for aesthetic rehabilitation of endodontically treated teeth in cases of great dental crown destruction or small dental absences (AU).


Introdução:A reabilitação estética de dentes tratados endodonticamente depende do grau de destruição da coroa, do dente em questão, do suporte ósseo, do tipo de prótese e dos tipos de forças a que esses dentes serão submetidos. As resinas compostas indiretas apresentam propriedades físicas e mecânicas aprimoradas graças à incorporação de componentes inorgânicos e monômeros multifuncionais com maior número de pontos de união, tornando-os capazes de solucionar os problemas em que seriam indicadas restaurações cerâmicas. Objetivo:Apresentar um relato de caso clínico de uma reabilitação estética de dentes anteriores com resina composta indireta como alternativa de tratamento viável e de menor custo.Relato de Caso:Ao exame clínico foram observadas restaurações amplas e deficientes nos dentes anteriores superiores. O plano de tratamento proposto reabilitação estética dos elementos dentários com cerômeros.Conclusões:Este tratamento representou uma opção viável e demenor custo que pode ser utilizado tanto em situações de grande destruição dentária como em pequenas ausências dentárias, em substituição às restaurações de cerâmica (AU).


Introducción: La rehabilitación estética de los dientes tratados endodónticamente depende del grado de destrucción de la corona, el diente en cuestión, el soporte óseo, el tipo de prótesis y los tipos de fuerzas a las que estos dientes serán sometidos. Las resinas compuestas indirectas tienen propiedades físicas y mecánicas mejoradas gracias a la incorporación de componentes inorgánicos y monómeros multifuncionales con mayor número de puntos de unión, lo que las hace capaces de resolver los problemas en los que estarían indicadas las restauraciones cerámicas. Objetivo: Presentar un caso clínico de rehabilitación estética de dientes anteriores con resina compuesta indirecta como alternativa de tratamiento viable y menos costosa. Reporte de Caso:En el examen clínico, se observaron restauraciones extensas y deficientes en los dientes anteriores superiores. El plan de tratamiento propuesto para la rehabilitación estética de elementos dentales con cerómeros. Conclusiones:Este tratamiento representó una opción viable y menos costosa que se puede utilizar tanto en situaciones de gran destrucción dentaria como en pequeñas ausencias dentales, en sustitución de las restauraciones cerámicas (AU).


Subject(s)
Humans , Female , Adult , Adhesiveness , Composite Resins , Crowns , Mouth Rehabilitation/instrumentation , Brazil/epidemiology
20.
RFO UPF ; 26(2): 323-333, 20210808. tab
Article in English | LILACS, BBO | ID: biblio-1452537

ABSTRACT

Objetivo: O objetivo deste estudo foi responder qual é a melhor técnica para remoção de pinos de fibra de vidro e pinos metálicos fundidos considerando tempo, preservação da estrutura dentária e custos. Métodos: Foi realizado um estudo in vitro, randomizado e cego. Sessenta dentes tratados endodonticamente foram randomizados em dois grupos de acordo com o tipo de pino. Uma segunda randomização foi realizada para cada tipo de técnica de remoção (ultrassom, broca ou combinada; n=10). One-way ANOVA foi usado para comparar o tempo de remoção do pino, teste t pareado comparou a quantidade de estrutura dentária removida e Kruskal Wallis seguido pelo teste post hoc de Mann-Whitney foram usados para análise de custo (P = 0,05). Resultados: Não houve diferença no tempo de remoção do pino considerando o tipo ou técnica do pino (P=0,630). A perda média de estrutura dentária na região cervical foi superior a 30% quando apenas uma ponta diamantada foi usada para remover pino de fibra de vidro (P<0,00001) e pino metálico fundido (P=0,008). Conclusão: De acordo com os resultados deste estudo, podemos concluir que a seleção da técnica de remoção dependerá da habilidade do operador, e sempre ocorrerá alguma perda de estrutura dentária, embora seja esperada uma perda maior quando apenas pontas diamantadas são usadas para este fim.(AU)


Objective: The aim of this study was to answer which is the best technique to removing glass fiber post and cast metal post considering time, preservation of tooth structure, and costs. Methods: An in vitro, randomized, blinded study was conducted. Sixty endodontically treated teeth were randomized into two groups according to post type. A second randomization was performed for each type of removal technique (ultrasound, drill, or combined; n=10). One-way ANOVA was used to compare the time to post removal, paired t-test compared the amount of tooth structure removed and Kruskal Wallis followed by post hoc Mann-Whitney test were used for cost analysis (P=0.05). Results: There was no difference in post removal time considering post type or technique (P=0.630). The average loss of tooth structure in the cervical region was greater than 30% when only a diamond bur was used to remove fiber glass post (P<0.00001) and cast metal post (P=0.008). Conclusion: According to the results of this study, we can conclude that the selection of the removal technique will depend on the skill of the operator, and some loss of tooth structure will always occur, although greater loss is expected when only diamond burs are used for this purpose.(AU)


Subject(s)
Humans , Post and Core Technique/economics , Device Removal/economics , Dental Pins/economics , Reference Values , Time Factors , Random Allocation , Analysis of Variance , Statistics, Nonparametric , Costs and Cost Analysis , Device Removal/methods
SELECTION OF CITATIONS
SEARCH DETAIL