China Journal of Orthopaedics and Traumatology ; (12): 128-132, 2023.
Article in Chinese | WPRIM | ID: wpr-970833

ABSTRACT

OBJECTIVE@#The relationship between the distal screws and the wrist articular surface was assessed by the additional lateral oblique fluoroscopic view during the operation, and the dorsal tangential view of the wrist was used to observe whether the distal screw penetrated the dorsal cortex, so as to evaluate the clinical efficacy of the volar locking plate in the treatment of distal radius fractures.@*METHODS@#From January 2020 to June 2021, 45 cases of fresh distal radius fractures were treated using the volar Henry's approach, including 20 males and 25 females, aged from 32 to 75 years old with an average of (52.4±8.1) years old. During the operation, they were divided into 2 groups according to the different intraoperative fluoroscopic views:the control group of 20 cases, treated with standard anteroposterior and lateral fluoroscopic view;25 cases in the observation group, additional lateral oblique fluoroscopic view and dorsal tangential view of the wrist were taken. The wrist joint function score and postoperative complications were evaluated at 6 weeks, 3 and 6 months after operation between two groups.@*RESULTS@#All 45 patients were followed up and the duration ranged from 6 to 14 months, with an average of (10.8±1.7) months, all patients achieved bone union and the incision healed well. The incidence of postoperative complications in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). In terms of Gartland-Werley score of wrist joint function, the score of wrist function in the observation group was (4.58±1.31) at 6 weeks, (2.98±0.63) at 3 months and (1.95±0.65) at 6 months post-operatively, which were better than those in the control group (6.32±1.96) at 6 weeks, (3.63±0.76) at 3 months and (2.43±0.73) at 6 months. The difference was statistically significant (P<0.05). In the observation group, 7/25 cases(28%) were found to have screw penetration during the operation by additional lateral oblique and dorsal tangential radiograph fluoroscopic views of wrist.@*CONCLUSION@#The addition of lateral oblique and dorsal tangential during the operation could improve the accuracy of distal screw placement, reduce postoperative complications, and achieve early functional exercise.


Subject(s)
Male , Female , Humans , Adult , Middle Aged , Aged , Wrist Fractures , Radius Fractures/surgery , Fracture Fixation, Internal/methods , Fluoroscopy/methods , Bone Plates , Postoperative Complications
2.
Journal of the Korean Fracture Society ; : 46-52, 2015.
Article in Korean | WPRIM | ID: wpr-192974

ABSTRACT

PURPOSE: The purpose of this study is to evaluate outcome of variable-angle volar locking plate for treatment of distal radius fractures. MATERIALS AND METHODS: We retrospectively analyzed the results in 45 cases treated by variable-angle volar locking plate. We evaluated the clinical results according to the Mayo wrist performance scoring system and radiographic results. RESULTS: All cases had bony union. The mean Mayo wrist performance scoring system was 84.8. Between preoperative and immediate postoperative radiographic measurement, the mean radial length improved from 8.4 to 11.8 mm, radial inclination from 14.2degrees to 22.4degrees, volar tilt from -4.5degrees to 9.6degrees, and intraarticular step-off from 1.8 to 0.3 mm (p0.05). All cases showed bone union with no evidence of malunion, nonunion, or metal failure. CONCLUSION: Treatment of distal radius fractures using variable angle volar locking plate showed satisfactory outcomes. It is a good option to obtain stable fixation without significant loss of reduction.


Subject(s)
Follow-Up Studies , Radius Fractures , Radius , Retrospective Studies , Wrist
3.
Journal of the Korean Society for Surgery of the Hand ; : 149-153, 2011.
Article in Korean | WPRIM | ID: wpr-45589

ABSTRACT

PURPOSE: To describe the surgical treatment of the complex dorsal metacarpophalangeal dislocations and its results, emphasizing on the modified volar approach with A1 pulley release. MATERIALS AND METHODS: We experienced 6 cases of dorsal dislocation of the metacarpophalangeal joint. We performed open reduction with the modified volar approach described by Eaton and Dray. Postoperatively posteroanterior and lateral radiographs of the index finger metacarpophalangeal joint and metacarpophalangeal joint range of motion was followed. RESULTS: One case with a large osteochondral fracture was operated with volar and doral approach both. Overall end results were good without any significant restriction of motion and stability of the fingers. CONCLUSION: Modified volar approach with A1 pulley release is an excellent method for complex dorsal metacarpophalangeal dislocations without osteochondral fracture.


Subject(s)
Benzodiazepines , Joint Dislocations , Fingers , Metacarpophalangeal Joint , Range of Motion, Articular
4.
Journal of the Korean Fracture Society ; : 151-155, 2011.
Article in Korean | WPRIM | ID: wpr-11167

ABSTRACT

PURPOSE: To evaluate outcomes 2.4 mm volar locking compression plate for treatment of unstable distal radius fractures. MATERIALS AND METHODS: We retrospectively analyzed the results in 22 cases, which were treated by 2.4 mm volar locking compression plate. We evaluated the clinical results according to the Mayo wrist performance scoring system and radiographic results. RESULTS: All cases had bony union. The mean Mayo wrist performance score was 85.23. Between preoperative and immediate postoperative radiographic measurements, the mean radial length was improved from 6.04 mm to 9.68 mm, radial inclination from 15.61degrees to 19.61degrees, volar tilt from -13.73degrees to 7.66degrees and intraarticular step-off from 0.79 mm to 0.33 mm (p0.05). Postoperative complication included that flexor pollicis longus and 2nd flexor digitorum profundus were ruptured in 1 case. CONCLUSION: Treatment of unstable distal radius fractures using a 2.4 mm volar locking compression plate showed satisfactory outcomes. It is a good option to obtain stable fixation without significant loss of reduction.


Subject(s)
Follow-Up Studies , Postoperative Complications , Radius , Radius Fractures , Retrospective Studies , Wrist
5.
Journal of the Korean Fracture Society ; : 220-224, 2008.
Article in Korean | WPRIM | ID: wpr-115789

ABSTRACT

PURPOSE: To evaluate outcomes volar T-locking compression plate for treatment of unstable distal radius fractures. MATERIALS AND METHODS: We retrospectively analysed the results in 35 cases, which were treated by volar plating with T-LCP. We evaluated the clinical results according to the Mayo wrist scoring system and radiographic results. RESULTS: The mean score was 83.86 respectively. Between preoperative and immediate postoperative radiographic measurements, averaged radial length was improved from 5.75 mm to 11.53 mm, radial inclination from 12.86 degrees to 22.56 degrees, volar tilt from -3.64 degrees to 9.90 degrees and intraarticular step-off from 1.48 mm to 0.42 mm. Between immediate postoperative and latest follow-up radiographic measurements, mean loss of radial length measured 0.43 mm, radial inclination 0.46 degrees, volar tilt 0.89 degrees. CONCLUSION: Treatment of unstable distal radius fractures using a volar T-LCP showed satisfactory outcomes. We think that it is good surgical option to allow return to daily living, result in early postsurgical wrist motion.


Subject(s)