Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Braz. dent. j ; 30(5): 505-510, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1039138

ABSTRACT

Abstract The aim of this study was to investigate the three-dimensional wear, volumetric loss and surface roughness after chewing simulation of two glass ceramics. Lithium disilicate (LD, Emax CAD, Ivoclar) and Zirconia reinforced lithium silicate (ZLS, Vita Suprinity, Vita Zhanfabrick) discs (n=20/g) were scanned to obtain stereolithography (STL) files for each sample. All discs were submitted to chewing simulation with sliding configuration (30 N, 300,000 cycles, 6 mm and 1.7 Hz) with steatite as antagonist. The samples were then scanned again and the volume loss and the deepest defect depth was measured using the superimposed file from the baseline using three-dimensional digital parametric inspection software (GOM Inspect, Braunschweig, Germany). Surface roughness (Ra and Rz) was analyzed with a contact profilometer. Data were analyzed by one-way ANOVA and Tukey test (α=0.5%). ANOVA showed significant differences among the groups. Considering the ceramic volume loss, wear depth defect length and Rz roughness, LD (-22.09±5.57%; 0.80±0.06 µm; 3.08±1.02 µm) showed higher mean values than ZLS (-15.67±4.51%; 0.56±0.09 µm; 1.51±0.90 µm). Ra mean values were similar for both materials (p=0.064). All discs exhibited slight surface scratches along with the sliding direction with pitted wear patterns, while large cracks were observed on wear traces. These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software. The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape. ZLS was more resistant to wear than LD, with less volume loss and shallower surface defects.


Resumo O objetivo deste estudo foi investigar o desgaste tridimensional, perda volumétrica e rugosidade após a simulação de mastigação de dois materiais vitro-cerâmicos. Discos de dissilicato de lítio (LD, Emax CAD, Ivoclar) e silicato de lítio reforçado com zircônia (ZLS, Vita Suprinity, Vita Zhanfabrick) (n=20/g) foram confeccionados e digitalizados para obtenção de arquivos de estereolitografia (STL) de cada amostra. Todos os discos foram submetidos à simulação de mastigação com configuração deslizante (30 N, 300.000 ciclos, 6 mm e 1,7 Hz) com esteatita como antagonista. As amostras foram escaneadas novamente e a perda de volume e o defeito mais profundo foram medidos usando o arquivo sobreposto da linha de base através de um software de inspeção paramétrica digital e tridimensional (GOM Inspect, Braunschweig, Alemanha). A rugosidade superficial (Ra e Rz) foi avaliada através de rugosímetro de contato. Os resultados foram analisados por ANOVA 1-fator e teste Tukey (α=0,5%). ANOVA mostrou diferenças significantes entre os grupos. Considerando a perda de volume cerâmico, comprimento do defeito e rugosidade Rz, LD (-22,09±5,57%; 0,80±0,06 µm; 3,08±1.02 µm) apresentou valores médios superiores a ZLS (-15,67±4,51%; 0,56±0,09 µm; 1.51±0.90 µm). Todos os discos exibiram pequenos arranhões na superfície conforme a direção de deslizamento com padrões de desgaste, enquanto grandes ranhuras foram observadas nos traços de desgaste. Essas mesmas áreas podem ser identificadas em azul, sobrepondo os arquivos STL antes e depois da simulação de mastigação no software de inspeção. A redução linear gerada pelo contato deslizante mostra um gráfico com uma forma de padrão de desgaste semelhante. ZLS foi mais resistente ao desgaste do que LD, com menor perda de volume e menores defeitos superficiais.


Subject(s)
Ceramics , Mastication , Surface Properties , Materials Testing , Dental Porcelain
2.
Korean Journal of Nuclear Medicine ; : 30-40, 2004.
Article in Korean | WPRIM | ID: wpr-168778

ABSTRACT

PURPOSE: The aims of this study were to find brain regions in which gray matter volume was reduced and to show the capability of voxel-based morphometry (VBM) analysis for lateralizing epileptogenic zones in medial temporal lobe epilepsy (mTLE). The findings were compared with fluorodeoxyglucose positron emission tomography (FDG PET). MATERIALS AND METHODS: MR T1-weighted images of 12 left mTLE and 11 right mTLE patients were compared with those of 37 normal controls. Images were transformed to standard MNI space and averaged in order to create study-specific brain template. Each image was normalized to this local template and brain tissues were segmented. Modulation VBM analysis was performed in order to observe gray matter volume change. Gray matter was smoothed with a Gaussian kernel. After these preprocessing, statistical analysis was performed using statistical parametric mapping software (SPM99). FDG PET images were compared with those of 22 normal controls using SPM. RESULTS: Gray matter volume was significantly reduced in the left amygdala and hippocampus in left mTLE. In addition, volume of cerebellum, anterior cingulate, and fusiform gyrus in both sides and left insula was reduced. In right mTLE, volume was reduced significantly in right hippocampus. In contrast, FDG uptake was decreased in broad areas of left or right temporal lobes in left TLE and right TLE, respectively. CONCLUSIONS: Gray matter loss was found in the ipsilateral hippocampus by modulation VBM analysis in medial temporal lobe epilepsy. This VBM analysis might be useful in lateralizing the epileptogenic zones in medial temporal lobe epilepsy, while SPM analysis of FDG PET disclosed hypometabolic epileptogenic zones.


Subject(s)
Humans , Amygdala , Brain , Cerebellum , Epilepsy, Temporal Lobe , Hippocampus , Positron-Emission Tomography , Temporal Lobe
3.
Japanese Journal of Physical Fitness and Sports Medicine ; : 239-249, 1995.
Article in Japanese | WPRIM | ID: wpr-371687

ABSTRACT

A study was carried out to examine the effects of water replacement on cardiovascular function during kendo practice in a hot environment. Five male college kendoists performed moderately severe 30-min kendo practice at a WBGT index of about 27°C with and without water intake. For water replacement, the subjects ingested 700 ml water (500 ml before exercise and 200 ml at 15 min after the start of exercise) . Under both conditions, body weight was decreased significantly, and hematocrit and serum total protein concentration were increased significantly after the exercise. With water replacement, the body weight loss induced by the exercise was similar to that under water deprivation. However, the decrease in body weight from the basal body weight, i. e. body weight measured before water intake, was significantly less with water replacement than under water deprivation. There were no significant differences in the percentage increases of hematocrit and serum total protein concentration between the two conditions, although the percentage change in plasma vasopressin concentration was significantly lower with water replacement than without. In the subjects deprived of water, the left ventricular end-diastolic dimension and left atrial dimension were significantly reduced after the exercise, and stroke volume, ejection fraction, and fractional shortening were also decreased significantly. The ratio of left ventricular end-systolic wall stress to left ventricular end-systolic volume index was increased significantly after the exercise without water intake. With water replacement, however, the percentage decreases in cardiac dimensions, stroke volume, ejection fraction, and fractional shortening were significantly lower than those under water deprivation. There was no significant change in the ratio of left ventricular end-systolic wall stress to left ventricular end-systolic volume index before and after the exercise with water intake. It is suggested that 700 ml water replacement before and during kendo exercise in a hot environment prevents depletion of stroke volume and deterioration of cardiovascular function, although it might not improve significantly the plasma volume loss after exercise.

SELECTION OF CITATIONS
SEARCH DETAIL