Odovtos (En línea) ; 23(2)ago. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386535

ABSTRACT

ABSTRACT: Cone-beam computed tomography (CBCT) is a 3D imaging technique widely used in maxillofacial diagnosis. The grayscale value (GSV) is a number that represents the amount of attenuation of the X-ray beam by the material contained in each voxel or structural unit of the tomographic volume. Similarly, in computed tomography (CT) used in medical radiology, the attenuation values are standardized in the Hounsfield Unit (HU) scale. Although GSV may have interesting potential applications in maxillofacial diagnosis, it is essential to know that HU differ from GSV. The latter are susceptible to multiple technical factors during the tomographic acquisition, so their value can vary among different CBCT scanners or when technical parameters are modified. Hence, GSV should not be extrapolated between different CBCT machines, and their use should be cautious while more investigation is available considering various equipment and acquisition protocols.


RESUMEN: La tomografía computarizada de haz cónico (CBCT, por sus siglas en inglés) es una técnica de imagen 3D ampliamente usada en diagnóstico maxilofacial. El valor de densidad en la escala de grises (DEG) es una cifra que corresponde al grado de atenuación de los rayos x del material representado en cada vóxel o unidad estructural de la tomografía. De forma similar, en los sistema de tomografía computarizada de uso médico (CT) el valor de atenuación está estandarizado en las Unidades Hounsfield (UH). Aunque los valores de DEG pueden tener interesantes usos potenciales en el apoyo de diagnóstico en el área dentoalveolar, es importante conocer que los valores UH no son los mismos a los valores DEG, y que los valores de DEG son susceptibles a múltiples factores técnicos durante la adquisición de la tomografía, por lo que se pueden obtener resultados distintos entre equipos y al variar parámetros técnicos en las tomas. Por lo tanto sus valores no deben extrapolarse entre equipos y su uso debe ser cauteloso mientras se realiza mayor investigación específica para cada equipo y para cada protocolo de adquisición.


Subject(s)
Titrimetry , Cone-Beam Computed Tomography/methods
2.
Korean Journal of Radiology ; : 641-647, 2015.
Article in English | WPRIM | ID: wpr-83660

ABSTRACT

OBJECTIVE: To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. MATERIALS AND METHODS: A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and 8-mm in diameter) was scanned twice, first in conventional pitch mode (CPM) and then in HPM using DSCT. The relative percentage volume errors (RPEs) of 3D volumetry were compared between the HPM and CPM. In addition, the intermode volume variability (IVV) of 3D volumetry was calculated. RESULTS: In the measurement of the 6-mm and 8-mm nodules, there was no significant difference in RPE (p > 0.05, respectively) between the CPM and HPM (IVVs of 1.2 +/- 0.9%, and 1.7 +/- 1.5%, respectively). In the measurement of the 4-mm nodules, the mean RPE in the HPM (35.1 +/- 7.4%) was significantly greater (p < 0.01) than that in the CPM (18.4 +/- 5.3%), with an IVV of 13.1 +/- 6.6%. However, the IVVs were in an acceptable range (< 25%), regardless of nodule size. CONCLUSION: The accuracy of 3D volumetry with HPM for solid pulmonary nodule is comparable to that with CPM. However, the use of HPM may adversely affect the accuracy of 3D volumetry for smaller (< 5 mm in diameter) nodule.


Subject(s)
Humans , Imaging, Three-Dimensional/instrumentation , Lung/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Multiple Pulmonary Nodules/diagnostic imaging , Phantoms, Imaging , Solitary Pulmonary Nodule/diagnostic imaging , Tomography, X-Ray Computed/instrumentation
3.
China Medical Equipment ; (12): 116-117,118, 2015.
Article in Chinese | WPRIM | ID: wpr-601853

ABSTRACT

Objective:To discuss the X-ray digital tomosynthesis (Digital Tomosynthesis, DTS) application value in the occult fractures of the scaphoid. Methods: we selected 19 patients in our hospital in 2012 examined by DTS, who were negative or highly suspicious of occult fracture with X-ray examination, and spiral CT (SCT) three-dimensional (3D) reconstructions were applied in seven patients. Results:There were 17 patients with fracture by DTS.7 patients showed fracture by spiral CT(SCT) three-dimensional(3D) reconstructions. Conclusion:Compared with X-ray examination, the image quality of Digital Tomosynthesis (DTS) is higher, which can show occult fracture better. Compared with CT, DTS can show spatial location of bony anatomy more clearly and can obtain more detailed information. With the important extension and supplement of CT and MRI, the distal tomosynthesisis is worth to be generalized for lower radiation, lower price, higher positive rate and high quality of the pictures.