Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Journal of Zhejiang University. Medical sciences ; (6): 195-206, 2023.
Article in English | WPRIM | ID: wpr-982035

ABSTRACT

OBJECTIVES@#To detect the contents of Tangwei capsule main components with high performance liquid chromatography-quantitative analysis of multicomponents by single marker (HPLC-QAMS) method and to evaluate the quality with chemometrics and entropy weight-technique for order preference by similarity to an ideal solution (EW-TOPSIS).@*METHODS@#A symmetry C18 column and 0.1% formic acid-acetonitrile as mobile phase were used for HPLC of Tangwei capsule. The contents of 3'-hydroxypuerarin, puerarin, 3'-methoxypuerarin, methylnissolin-3-O-glucoside, calycosin, formononetin, rosmarinic acid, salvianolic acid B, dihydrotanshinone Ⅰ, cryptotanshinone, tanshinone Ⅰ, tanshinone ⅡA and cucurbitacin B in 15 batches of Tangwei capsule were determined simultaneously. The quality differences of 15 batches of samples were analyzed by chemometrics and EW-TOPSIS.@*RESULTS@#The HPLC-UV showed that 13 components had good linear relationships in corresponding concentration ranges (r≥0.9991). The relative standard deviations (RSD) of precision, repeatability and stability were all less than 2.00%. The average recovery rates were between 96.86% and 100.13%, and RSD were all less than 2.00%. Cluster analysis showed that 15 batches of samples were clustered into 3 groups. Partial least squares-discriminant analysis showed that salvianolic acid B, formononetin, puerarin, 3'-methoxypuerarin and rosmarinic acid were the main potential markers affecting the quality of Tangwei capsule. EW-TOPSIS analysis showed that the quality of S12-S15 was superior.@*CONCLUSIONS@#The analytical method established in this study can be used for the comprehensive evaluation of the quality of Tangwei capsule to provide laboratory support for its quality control and overall evaluation.


Subject(s)
Drugs, Chinese Herbal , Chromatography, High Pressure Liquid/methods , Chemometrics , Entropy
2.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 130-139, 2023.
Article in Chinese | WPRIM | ID: wpr-973754

ABSTRACT

ObjectiveTo evaluate the quality of Mori Cortex from different producing areas by the entropy weight-technique for order preference by similarity to an ideal solution(TOPSIS), and to provide a new evaluation method for the quality control of Mori Cortex. MethodAccording to the five key indexes of color, thickness, texture, powdery and cortex remain, a subjective scoring table was designed to evaluate the appearance of Mori Cortex. High performance liquid chromatography(HPLC) was used to determine the fingerprint and the contents of multiple components(mulberroside A, chlorogenic acid, oxyresveratrol, mulberroside C, sanggenone D, sanggenone C, morusin), and chemometrics was used to explore the differential components of Mori Cortex from different habitats. On this basis, TOPSIS was used to comprehensively evaluate the quality of Mori Cortex from different habitats, and SPSS 22.0 software was used to carry out bivariate correlation analysis between thickness and appearance color with contents of seven components of Mori Cortex. ResultThose with lighter color, thicker root bark, tougher texture, sufficient powder and less cortex remain scored higher, and the top five were all from Anhui. The established fingerprint and determination methods were stable and reliable. Partial least squares-discriminant analysis(PLS-DA) screened three components with the variable importance in the projection(VIP) value>1(mulberroside A, sanggenone D, sanggenone C), which made an important contribution to the difference in the origin of Mori Cortex. Correlation analysis showed that there was a significantly positive correlation between mulberroside C with lightness value(L*) and total chromaticity value(E*ab) and mulberroside A with yellow-blue value(b*)(P<0.05, P<0.01), a significantly negative correlation between sanggenone C with b* and between morusin with L*(P<0.05, P<0.01). And there was a significantly negative correlation between mulberroside A, chlorogenic acid, and morusin with thickness(P<0.01), a clearly negative correlation between sanggenone D with thickness(P<0.05), a significantly positive correlation between sanggenone C with thickness(P<0.01). TOPSIS comprehensive scores showed that the samples from Anhui had a good score and ranked high. ConclusionThere are great differences in the quality of Mori Cortex from different habitats, and those with the close habitats show similar characteristics in appearance and component content, and lighter color and less cortex were positively correlated with the quality. Among them, the quality of Mori Cortex from Anhui is relatively good.

3.
The Journal of Korean Academy of Prosthodontics ; : 135-143, 2017.
Article in English | WPRIM | ID: wpr-91674

ABSTRACT

PURPOSE: This research was conducted to compare the marginal and internal fit of zirconia prostheses fabricated with the model scan method and the intraoral scan method. MATERIALS AND METHODS: In this study, 20 extracted human mandibular first molar was used in the preparation of abutment tooth for the fabrication of zirconia prostheses. In the first group, the model scan method was applied on 10 prepared teeth. In the other group, the intraoral scan method was used on other 10 prepared teeth. Datum of both groups were transmitted to the software system. Afterwards, 20 zirconia prostheses were fabricated using the Ceramill system. Weight technique was used to evaluate the internal gap of the zirconia prostheses. In the Replica technique, marginal gap of the zirconia prostheses were analyzed by optical microscopy. Statistical analysis was based on one-way ANOVA. RESULTS: Model scan group showed lower average weight than intraoral scan group when weight technique was applied, which has significance (P < .05). Also, model scan group showed significantly lower figures in all 5 measurements of replica technique than intraoral scan group (P < .05). CONCLUSION: Zirconia prostheses of both groups demonstrated clinically acceptable margin and internal fit. However, model scanned zirconia prostheses showed higher marginal and internal fit than intraoral scanned crowns.


Subject(s)
Humans , Crowns , Methods , Microscopy , Molar , Prostheses and Implants , Replica Techniques , Tooth
4.
The Journal of Advanced Prosthodontics ; : 439-448, 2016.
Article in English | WPRIM | ID: wpr-213531

ABSTRACT

PURPOSE: The purposes of this study are to evaluate the internal and marginal adaptation of two widely used CAD/CAM systems and to study the effect of porcelain press veneering process on the prosthesis adaptation. MATERIALS AND METHODS: Molar of a lower jaw typodont resin model was prepared by adjusting a 1.0 mm circumferential chamfer, an occlusal reduction of 2.0 mm, and a 5° convergence angle and was duplicated as an abrasion-resistant master die. The monolithic crowns and copings were fabricated with two different CAD/CAM system-Ceramil and Zirkonzahn systems. Two kinds of non-destructive analysis methods are used in this study. First, weight technique was used to determine the overall fitting accuracy. And, to evaluate internal and marginal fit of specific part, replica technique procedures were performed. RESULTS: The silicone weight for the cement space of monolithic crowns and copings manufactured with Ceramil system was significantly higher than that from Zirkonzahn system. This gap might cause the differences in the silicone weight because the prostheses were manufactured according to the recommendation of each system. Marginal discrepancies of copings made with Ceramil system were between 106 and 117 µm and those from Zirkonzahn system were between 111 and 115 µm. Marginal discrepancies of copings made with Ceramil system were between 101 and 131 µm and those from Zirkonzahn system were between 116 and 131 µm. CONCLUSION: Marginal discrepancy was relatively lower in Ceramil system and internal gap was smaller in Zirkonzahn system. There were significant differences in the internal gap of monolithic crown and coping among the 2 CAD/CAM systems. Marginal discrepancy produced from the 2 CAD/CAM systems were within a reported clinically acceptable range of marginal discrepancy.


Subject(s)
Crowns , Dental Porcelain , Jaw , Molar , Prostheses and Implants , Replica Techniques , Silicon , Silicones
SELECTION OF CITATIONS
SEARCH DETAIL