Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Year range
1.
Braz. j. otorhinolaryngol. (Impr.) ; 88(3): 289-295, May-June 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1384173

ABSTRACT

Abstract Introduction Modern medicine offers a wide spectrum of different hearing devices, and bone conduction implants can be found among them. Objective The presentation of the outcomes of the implantation of a new active bone conduction hearing implant - the Osia®, and its comparison with the well-known passive transcutaneous system - the Baha® Attract. Methods Eight adult patients with bilateral mixed hearing loss were randomly divided into two groups. Group 1 was implanted with the Osia®, and group 2 was implanted with the Baha® Attract. The details of the surgery were analyzed, along with the functional and audiological results. Results In all the cases, the surgery was successful, and the healing uneventful. In both groups, it was observed that pure tone audiometry and speech audiometry in free field improved significantly after the implantation (mean gain in pure tone audiometry for the Osia group 42.8 dB SPL and for the Baha group 38.8 dB SPL). In the Osia group, the results after the surgery were much better than with the Baha® 5 Power processor on the Softband. The patients implanted with the Osia® evaluated the quality of their hearing as being superior to those implanted with the Baha® Attract. There was an evident improvement in the abbreviated profile of hearing aid benefit questionnaire and in the speech, spatial and qualities of hearing scale for both systems. In the abbreviated profile of hearing aid benefit, changes were more evident in the Osia group (in global score 49% vs. 37.2%). Conclusion Implantation of the Osia® is an effective treatment option for the patients with bilateral mixed hearing loss. The surgery is safe but more complex and time-consuming than the Baha® Attract implantation. The preliminary audiological results as well as the overall quality of life indicate that the Osia® is a better solution than the Baha® Attract. However, future studies should be carried out to make further observations in a larger group of patients, and with longer follow-up.


Resumo Introdução A medicina moderna oferece um amplo espectro de diferentes aparelhos auditivos, e implantes de condução óssea estão entre eles. Objetivo Apresentação dos resultados do uso de um novo implante auditivo de condução óssea ativa - o Osia® e sua comparação com o conhecido sistema transcutâneo passivo - o sistema Baha® Attract. Método Oito pacientes adultos com perda auditiva mista bilateral foram divididos aleatoriamente em dois grupos. O grupo 1 foi implantado com o Osia® e o grupo 2 foi implantado com o sistema Baha® Attract. Os detalhes da cirurgia foram analisados, juntamente com os resultados funcionais e audiológicos. Resultados Em todos os casos, a cirurgia foi bem-sucedida e a cicatrização ocorreu sem intercorrências. Nos dois grupos, observou-se que a audiometria de tons puros e a audiometria de fala em campo livre melhoraram significativamente após o implante (ganho médio na audiometria para tons puros para o grupo Osia® de 42,8 dB NPS e para o grupo Baha®, 38,8 dB NPS). No grupo Osia®, os resultados após a cirurgia foram muito melhores do que com o processador Baha® 5 Power no sistema SoftBand. Os pacientes implantados com o Osia® avaliaram melhor a qualidade de sua audição do que os implantados com o sistema Baha® Attract. Houve uma melhoria evidente no questionário abbreviated profile of hearing aid benefit e na escala speech, spatial and qualities of hearing, para ambos os sistemas. No questionario abbreviated profile of hearing aid benefit, as mudanças foram mais evidentes no grupo Osia® (escore global 49% vs. 37,2%). Conclusão O sistema Osia® é uma opção de tratamento eficaz para pacientes com perda auditiva mista bilateral. A cirurgia é segura, mas mais complexa e demorada que a implantação do sistema Baha® Attract. Os resultados audiológicos preliminares, bem como aqueles avaliando a qualidade de vida, indicam que o Osia® é uma alternativa melhor que o Baha® Attract. Entretanto, mais observações são necessárias em grupos maiores de pacientes e com tempo de seguimento mais longo.

2.
Acta Academiae Medicinae Sinicae ; (6): 429-434, 2021.
Article in Chinese | WPRIM | ID: wpr-887876

ABSTRACT

Objective To design a novel automatic dispensing and injecting system of positron radiopharmaceuticals,for precise dose dispensing,simplified operation,and reduction of occupational radiation exposure. Methods The automatic dispensing and injecting system was fabricated with tungsten alloy as the shielding material.The performance and radiation protection of the device were assessed. Results The total time of injection using the automatic dispensing and injecting system was about 60 s.The ratio of successful injection in stability test was 100%.The deviation of the dispensing dose with the system was ≤3%.With the tungsten alloy shield(40 mmPb of the cabinet,60 mmPb of the countertop,15 mmPb of the protective shield,and 50 mmPb of the inbuilt jar for radiopharmaceuticals),the average dose rate at 30 cm from the device was 1.44 μSv/h,and the radiation dose at the operator's extremity was reduced by 99%. Conclusions This automatic dispensing and injecting system of positron radiopharmaceuticals is easy to operate with precise dispensing dose.It is safe and meets the requirements of radiation protection.


Subject(s)
Electrons , Occupational Exposure/analysis , Radiation Dosage , Radiation Protection , Radiopharmaceuticals
3.
Journal of Medical Biomechanics ; (6): E021-E026, 2017.
Article in Chinese | WPRIM | ID: wpr-803805

ABSTRACT

Objective To design an improvement plan of piezoelectric actuator with displacement magnification structure, so as to reduce power consumption of the existing incus-stimulating piezoelectric actuator for middle ear implant. Methods First, based on anatomical structure of human ear, the piezoelectric actuator with displacement magnification structure and the one just composed of piezoelectric stack were designed, respectively, and the corresponding coupled mechanical models of the middle ear and the piezoelectric actuator were established. By comparing the calculation results from the two types of coupling mechanical models, the hearing compensation property and power consumption of the actuator before and after the implantation of displacement magnification structure were analyzed. Results After adding the displacement magnification structure, the sound pressure level (SPL) at 1 kHz frequency was increased from 100 dB to 113 dB, when the piezoelectric actuator was stimulated by 10.5 V effective voltage. In addition, when the actuator was stimulated by the piezoelectric stack, its power consumption at the frequency of 1, 2 and 4 kHz were 6.42, 1.56 and 0.28 mW, respectviely; after introducing the displacement magnification structure, power consumption at the above-mentioned 3 frequencies decreased to 0.39, 0.09 and 0.01 mW, resepectively. Conclusions Piezoelectric actuator with displacement magnification structure in this study can improve hearing compensation ability of the incus-stimulating middle ear implant and effectively reducing the power consumption. The research findings will help to further improve the structure design of middle ear implant, thus achieving better hearing compensation effect.

4.
Journal of Medical Biomechanics ; (6): 21-26, 2017.
Article in Chinese | WPRIM | ID: wpr-515104

ABSTRACT

Objective To improve the design plan and get a piezoelectric actuator with displacement magnification structure,so as to reduce power consumption of the existing incus-stimulating piezoelectric actuator for middle ear implant.Methods Based on anatomical structure of human ear,the piezoelectric actuator with displacement magnification structure,and the one only composed of piezoelectric stack were designed,respectively,then the corresponding coupled mechanical models of the middle ear with the piezoelectric actuator were established.By comparing the calculation results from the two types of coupled mechanical models,the hearing compensation property and power consumption of the actuator before and after the implantation with the displacement magnification structure were analyzed.Results After adding the displacement magnification structure,the sound pressure level (SPL) at 1 kHz frequency was increased from 100 dB to 113 dB when the piezoelectric actuator was stimulated by 10.5 V effective voltages.In addition,for the piezoelectric stack,its power consumption at the frequency of 1,2 and 4 kHz were 6.42,1.56 and 0.28 mW,respectively;after introducing the displacement magnification structure,the power consumption at the above-mentioned 3 frequencies decreased to 0.39,0.09 and 0.01 mW,respectively.Conclusions Piezoelectric actuator with displacement magnification structure in this study can improve hearing compensation ability of the incus-stimulating middle ear implant,and effectively reduce the power consumption.The research findings will help to further improve the structure design of middle ear implant,thus achieving better hearing compensation effect.

5.
Chinese Medical Equipment Journal ; (6): 1-5, 2017.
Article in Chinese | WPRIM | ID: wpr-511276

ABSTRACT

Objective To develop a novel stress fracture animal model system based on dynamic cyclic mechanical loading.Methods Ulnae and tibiae of rats were respectively fixed using differently shaped fixtures (including a fixed holder and a movable holder).The axial mechanical loading was applied via a linear actuator based on LabVIEW control program.During the loading process,a load cell and a laser displacement transducer were used to detect the force and displacement changes in the limbs,respectively.The two signals were sampled at real time by PC-based LabVIEW data acquisition program.A compressive loading test (peak force of 50 N) was conducted to examine the consistency and reliability of cyclic loads after completing the loading system.The loading system and an ElectroForce 3220 mechanical testing machine were respectively used to measure and compare the Young's modulus of a standard ultra-high molecular weight polyethylene (UHMWPE)cylinder to calibrate the loading system.Results The compressive loading test (peak force of 50 N) demonstrated that the mechanical loading system was able to apply consistent loads with controllable intensity and time.The calibration experiment indicated the accuracy of the loading system.Conclusion The novel mechanical loading device has characteristics of precision,scientificity and reliability,and it is approaching the real development situation of stress fracture,which may provide a reliable experimental base for exploring the precautionary measures of stress fracture.

6.
Journal of Medical Biomechanics ; (6): 21-26, 2017.
Article in Chinese | WPRIM | ID: wpr-737298

ABSTRACT

Objective To improve the design plan and get a piezoelectric actuator with displacement magnification structure,so as to reduce power consumption of the existing incus-stimulating piezoelectric actuator for middle ear implant.Methods Based on anatomical structure of human ear,the piezoelectric actuator with displacement magnification structure,and the one only composed of piezoelectric stack were designed,respectively,then the corresponding coupled mechanical models of the middle ear with the piezoelectric actuator were established.By comparing the calculation results from the two types of coupled mechanical models,the hearing compensation property and power consumption of the actuator before and after the implantation with the displacement magnification structure were analyzed.Results After adding the displacement magnification structure,the sound pressure level (SPL) at 1 kHz frequency was increased from 100 dB to 113 dB when the piezoelectric actuator was stimulated by 10.5 V effective voltages.In addition,for the piezoelectric stack,its power consumption at the frequency of 1,2 and 4 kHz were 6.42,1.56 and 0.28 mW,respectively;after introducing the displacement magnification structure,the power consumption at the above-mentioned 3 frequencies decreased to 0.39,0.09 and 0.01 mW,respectively.Conclusions Piezoelectric actuator with displacement magnification structure in this study can improve hearing compensation ability of the incus-stimulating middle ear implant,and effectively reduce the power consumption.The research findings will help to further improve the structure design of middle ear implant,thus achieving better hearing compensation effect.

7.
Journal of Medical Biomechanics ; (6): 21-26, 2017.
Article in Chinese | WPRIM | ID: wpr-735830

ABSTRACT

Objective To improve the design plan and get a piezoelectric actuator with displacement magnification structure,so as to reduce power consumption of the existing incus-stimulating piezoelectric actuator for middle ear implant.Methods Based on anatomical structure of human ear,the piezoelectric actuator with displacement magnification structure,and the one only composed of piezoelectric stack were designed,respectively,then the corresponding coupled mechanical models of the middle ear with the piezoelectric actuator were established.By comparing the calculation results from the two types of coupled mechanical models,the hearing compensation property and power consumption of the actuator before and after the implantation with the displacement magnification structure were analyzed.Results After adding the displacement magnification structure,the sound pressure level (SPL) at 1 kHz frequency was increased from 100 dB to 113 dB when the piezoelectric actuator was stimulated by 10.5 V effective voltages.In addition,for the piezoelectric stack,its power consumption at the frequency of 1,2 and 4 kHz were 6.42,1.56 and 0.28 mW,respectively;after introducing the displacement magnification structure,the power consumption at the above-mentioned 3 frequencies decreased to 0.39,0.09 and 0.01 mW,respectively.Conclusions Piezoelectric actuator with displacement magnification structure in this study can improve hearing compensation ability of the incus-stimulating middle ear implant,and effectively reduce the power consumption.The research findings will help to further improve the structure design of middle ear implant,thus achieving better hearing compensation effect.

8.
Military Medical Sciences ; (12): 17-20,37, 2017.
Article in Chinese | WPRIM | ID: wpr-606379

ABSTRACT

Objective To design a controller for the air environment of cabins of special vehicles .Methods The microprocessor was used to collect and store parameters ,and calculate automatically the operative mode of actuators ,such as the fan,air-conditioner,oxygenerator,air cleaner, filtering and boosting devices according to the preset target values .Output commands by RS485 were used to control actuators .Results and Conclusion The controller is capable of control integration for air-adjusting equipment while improving the control effect of the air quality in cabins of special vehicles .

SELECTION OF CITATIONS
SEARCH DETAIL