1.
China Medical Equipment ; (12): 49-51,52, 2016.
Article in Chinese | WPRIM | ID: wpr-604708

ABSTRACT

Objective: To investigate the detection ability of two reagents by automated coagulation analyzer ACL-TOP using immune turbidimetric method, and to determine the merits and demerits of them. Methods:Two reagents were compared in the study. We selected 532 cases of hospitalized patients in Anzhen Hospital, 388 cases of which were unstable angina, 60 cases were pulmonary thromboembolism, 70 cases were coronary atherosclerosis, 14 cases were abdominal aneurysm, and the rest were the patients with high blood pressure and coronary heart disease. The plasmas of all the patients were extracted, and D-dimer was detected on ACL-TOP by D-Dimer (referred to as reagent A) and D-DHS (referred to as reagent B). Results:The results of D-dimer increased in different degrees, and there are 88 cases of false positive cases. The case whose FDP and individual D-dimer of D-dimer simultaneous detection was elevating and clinical symptoms were disappeared was detected by the VIDAS instrument platform verification. There were significant differences between A and B. The detection result of reagent A was [1594.15±2286.18], and reagent B was [912.97±1814.06]. There were significant differences between them (t=3.654, P<0.05). In addition, the consistency of the two reagents was poor (r=0.419, P<0.05). Conclusion:Comparing two reagents to detect D-dimer quantitatively by automated coagulation analyzer ACL-TOP, D-DHS owns greater ability to exclude false-positive results, so does the ability of anti-interference with jaundice, hemolysis and chylemia.

2.
Chinese Medical Equipment Journal ; (6): 117-118, 2009.
Article in Chinese | WPRIM | ID: wpr-405977

ABSTRACT

The question about interference in the use of medical equipment affects patient's diagnosis and treatment. Through analyzing the common interference problem, the related solutions are put forward.

3.
Chinese Journal of Medical Physics ; (6): 1508-1512, 2009.
Article in Chinese | WPRIM | ID: wpr-500224

ABSTRACT

Objective: Compare merits and drawbacks of existing ablative and non-ablative rejuvenation technologies, and complete study and design of a skin rejuvenation device based on a new rejuvenation mechanism using broad-spectrum infrared light (1100 nm ~1800nm). Methods: This article firstly presents skin rejuvenation mechanism based on the broad-spectrum infrared light, and then independently design by using corresponding systems at home and abroad for reference to make a high-quality device with lower costs compared to international corresponding systems. The device has a modular architecture design including system control module, power module, infrared emission, human machine interface, water circulating cooling and switch control module. The article details three key points in design: how to generate the required infrared pulsed light, human machine interface and anti-interference design. Results: The article gave the architecture diagram and human machine interface. The technical parameters measured by experiments satisfied the design requirements and the device can be used in clinics. Its stability, reliability and energy uniformity all meet requirements of infrared rejuvenation treatment. Conclusion: The device will have good applying prospect and market prospect in medical cosmetics.

4.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-590225

ABSTRACT

Objective To resolve the difficulty in controlling the transfusion speed by medical personnel.Methods By using liquid drop sampling module,pulsing signals of liquid drop were obtained,and then they were enlarged,shaped and the wrong signals from the top and bottom surface of every drop were excluded before the standard triggered signals were sent out to SCM processing circuit,from which the real-time liquid drop speed and the average drop speed in every minute were obtained.Results Anti-interference and portable transfusion-drop counter could show the real-time liquid drop value and the average liquid drop value in every minute.Conclusion Anti-interference and portable transfusion-drop counter is convenient with simple structure and has been used in clinic.

5.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-596068

ABSTRACT

The necessity of the Electrocardiograph anti-interference performance test are introduced,and the principle and method of anti-interference performance test based on standard YY 1139-2000 are also provided.Through the experiment of anti-interference,the reliability and practicality of our self-made testing device is confirmed.

6.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-588160

ABSTRACT

By designing the circuit structure of preamplifier and selecting new elements such as ultra low noise operational amplifier and linear opto-coupler,some difficulties in EEG acquisition is overcome and the Common Mode Rejection Ratio(CMRR) of preamplifier is highly increased.So EEG can be amplified and detected well.