Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Blood Transfusion ; (12): 995-998, 2022.
Article in Chinese | WPRIM | ID: wpr-1004162

ABSTRACT

【Objective】 To explore the effect of mobile transfusion closed-loop information system in the whole process management of clinical blood transfusion. 【Methods】 The hospital information system (HIS) of Soochow Hospital affiliated to Nanjing Medical University was integrated with the blood information system (BIS) and personal digital assistant (PDA) to build a closed-loop transfusion management process to ensure the safety of clinical blood use. From May 2021 to April 2022, 1 395 patients who were admitted to our hospital for blood transfusion therapy were studied. Among them, 632 patients from May to October 2021 (before the implementation of closed-loop management) were the control group, and 763 patients from November 2021 to April 2022 (after the implementation of closed-loop management) were the observation group. Before and after the implementation of closed-loop management, we compared the implementation rate of double-checking before blood sample collection, rate of transfusion within 30 min after blood issuing, implementation rate of double-checking of bedside transfusion, situation of patrol every 15 minutes, rate of transfusion completed within 4 h, rate of nursing documentation standardization, so as to evaluate the improvement effect of the whole process of transfusion management. 【Results】 The implementation rate of double-checking before blood sample collection was 99.48%(759/763) in the observation group and 93.99%(594/632) in the control group; the transfusion rate within 30 min after blood issuing was 95.02%(725/763) in the observation group and 91.46%(578/632) in the control group; the implementation rate of double-checking of bedside transfusion was 100%(763/763) in the observation group and 95.73%(605/632) in the control group; the complete rate of patrol every 15-min was 94.36%(720/763) in the observation group and 90.35%(571/632) in the control group; the completion rate of transfusion within 4 h was 95.81%(731/763) in the observation group and 92.25%(583/632) in the control group; the rate of nursing paperwork standardization was 98.03%(748/763) in the observation group and 81.80%(517/632) in the control group, and the difference between the two groups was statistically significant (P<0.05). 【Conclusion】 The mobile transfusion closed-loop information system can realize the whole process management of clinical blood transfusion, effectively improve the standardization of blood transfusion and transfusion documents, and guarantee the safety of clinical blood transfusion.

2.
Chinese Journal of Blood Transfusion ; (12): 420-423, 2021.
Article in Chinese | WPRIM | ID: wpr-1004540

ABSTRACT

【Objective】 To explore the effect of intelligent closed-loop mobile nursing management system in quality management of blood transfusion. 【Methods】 The mobile nursing system and the cold chain management system of our hospital were integrated to realize intelligent closed-loop management of blood transfusion. After consulting medical records, 789 blood recipients, admitted to the Department of Hematology of our hospital from January to December 2017 (before the implementation of closed-loop management), were selected as the control group, and 836 blood recipients, admitted during January to December 2018 (after the implementation of closed-loop management), were selected as the observation group. A self-designed blood transfusion standard management checklist was adopted, with the number of standard execution items as the numerator and the total number of checked items as the denominator to obtain the standard implementation rate. The checking rate of blood sample collection, blood transfusion rate within 30 min after blood issuing, the execution rate of double check specification and inspection specification, the completion rate of RBCs transfusion within 4 h and qualified rate of blood transfusion nursing record before and after the implementation of closed-loop management were compared by chi-square test or Fisher's exact probability method to evaluate the efficacy of blood quality management improvement. A total of 8 head nurses from clinical departments (Hematology Department, Cardiac Surgery Department, Operating Room, Comprehensive ICU) involved in blood transfusion were selected for semi-structured interviews. The interviews focused on the effect of intelligent closed-loop mobile nursing information system in quality management of clinical blood use, and the results of the interviews were analyzed. 【Results】 The double check execution rate of blood transfusion, the checking rate of blood sample collection specification, the transfusion rate within 30 min after blood issuing, the execution rate of blood transfusion inspection, the completion rate of RBCs transfusion within 4 h, the qualified rate of blood transfusion nursing record in the observation group and the control group after and before the implication of the intelligent closed-loop mobile nursing management system were 100%(836/836) vs 97.72%(771/789), 99.04%(828/836) vs 97.34%(768/789), 97.97%(819/836) vs 95.06%(750/789), 99.28%(830/836) vs 94.93%(712/789), 99.16%(829/836) vs 97.47%(769/789) and 100%(836/836) vs 89.73%(708/789), respectively, showing significant improvement (P < 0.05). The time spend on the record, summary and feedback of quality control results was significantly shortened. 【Conclusion】 The application of intelligent closed-loop mobile nursing management system in the quality management of clinical blood use can effectively improve the efficiency of blood transfusion, nursing quality and the safety of clinical blood use.

SELECTION OF CITATIONS
SEARCH DETAIL