Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
World Science and Technology-Modernization of Traditional Chinese Medicine ; (12): 542-548, 2017.
Article in Chinese | WPRIM | ID: wpr-695925

ABSTRACT

Translational medicine means that to establish a bridge between fundamental research and clinical medicine through bidirectional translation path in order to promote the translation and application from fundamental research to clinical medicine.The purpose of traditional Chinese medicine (TCM) translational model is to collate and build one multidimensional TCM translational model,rationality carry out the research on TCM translation.Three paths have been confirmed,where are from literature research to clinical verification,from clinical application to clinical verification,and from experiment to clinical verification.In this research,methodology of one path mcntioned above could be established,which is the key technology of translational medicine.Take constipation,insomnia,and post-flu cough as target diseases to investigate the herbal compounds which could be qualified for clinical application based on preliminary work.This research not only provided clinical data to TCM translation,but also established one methodology of TCM translation path--"from experiment to clinical verification".

2.
International Journal of Laboratory Medicine ; (12): 2789-2791,2793, 2015.
Article in Chinese | WPRIM | ID: wpr-602485

ABSTRACT

Objective To compare the performance of HP-083/4 and rational used instrument on detecting six items.Methods The rational instruments were used as contrast instrument,HP-083/4 was the verified instrument.A total of 100 blood specimens and 100 urine specimens were collected,and the levels of antistreptolysin O(ASO),hypersensitive C reactive protein (hsCRP),D-di-mer(D-D),glycosylated hemoglobin(HbA1c),rheumatoid factor(RF)and urine microalbumin(mAlb)were detected.The regression equation and correlation coefficient(r)of the two methods were calculated,and the Kappa values(κ)were analyzed to evaluate the performance of HP-083/4.Results There was a good linear correlation (r >0.950)for the two methods in detecting the serum ASO,hsCRP,D-D,HbA1c,RF and mAlb,r were 0.991,0.995,0.970,0.957,0.980 and 0.967 respectively.Besides,they had good concordance(κ>0.6),theκ values were 0.830,0.957,0.601,0.720,0.920 and 0.694 respectively.Conclusion HP-083/4 is effec-tive in detecting ASO,hsCRP,D-D,HbA1c,RF and mAlb,which should be suitable for clinical application.

3.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 82-85, 2012.
Article in Chinese | WPRIM | ID: wpr-428528

ABSTRACT

Objective Based on the mathematical models established in Department of Thoracic Surgery of Peking University People's Hospital for predicting malignant probability for solitary pulmonary nodules ( SPN),another continuous 145 patients with SPN were assessed to verify the accuracy of the model comparing with foreign models (Mayo model and VA model).Methods A retrospective cohort study in our institution included 145 patients with definite pathological diagnosis of SPN from Oct 2009 to Aug 2011,72 males and 73 females,average age (59.4 ± 12.2 ) years old.Clinical data included age,gender,course of disease,symptoms,history and quantity of smoking,time of smoking cessation,history of tumor,family history of tumor,tumor site,diameter,calcification,speculation,border,lobulation,traction of pleural,vascular convergence sign,and cavity.These raw data were incorporated into our model,Mayo model and VA model,the probability of malignant in every patient was calculated separately according to methods described before.The sensitivity and specificity of these 3 models were evaluated then.Afterwards,calibration of the 3 models was assessed by the Hosmer-Lemeshow (H-L) test.Discrimination was tested by calculating the area under curve ( AUC ) after the receiver operating characteristic (ROC) curve was drawn.Results 32.4% (47 in 145 patients) of the nodules were malignant,and 67.6% (98 in 145 patients) were benign in this group.Verified the accuracy of our model with sensitivity of 94.9%,specificity of 66.0%,positive predictive value of 85.3% and negative predictive value of 86.1%.The H-L test showed good fitting in all models ( P >0.05 ).The AUC for our model was 0.874 ±0.035,and 0.784 ± 0.041 in Mayo model (P =0.004 compared to our model),0.754 ± 0.041 in VA model (P =0.002 compare to our model).And,there was not significant statistical difference between Mayo model and VA model (P >0.05 ).Our model has the best precision indexed by AUC,which were statistically significant differential compared with Mayo model and VA model.Conclusion The model established by our center has superior value than foreign counterparts in predicting the probability of malignant or benign in patients with SPN.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 465-467, 2011.
Article in Chinese | WPRIM | ID: wpr-424195

ABSTRACT

Objective To investigate the safety and validity of Neptune 3D-RTPS-A treatment planning system compared to Prowess TPS.Methods A total of 30 clinical tumor cases with radiotherapy planning on Prowess TPS from September 2009 to May 2010 were used.The contours, organs at risk and target volumes in Prowess TPS were transported into Neptune TPS, the same parameters setted in the two treatment planning systems.The results of comparison of the two TPS were calculated.Results All cases of clinical treatment planning were completed successfully by Neptune TPS, and the various functions of the design were achieved for fitting tumor conformal radiation therapy.The key parameters on radiation treatment were compared.The results are as follows:the differences of source skin distance ( SSD ) <0.5% , differences of Monitor Unites <0.5%, the differences of dose at isocenter <2%, the differences of five isodose lines surrounding area < 3%, and the mean difference of distances of five isodose lines was 0.43 mm, the differences of the volume of PTV on 90% isodose line < 2%, and the differences in V30of organs at risk < 3%.Conclusions Neptune TPS could be qualified for clinical validity and safety by clinical verification.

5.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-585858

ABSTRACT

It is the first time to lay down a complete and accurate plan for clinical verification protocol of domestic SPECT. The protocol's application to the first domestic BHP6601 SPECT proves its definitive purpose, reliability and completion. The protocol can meet the requirements of the criterions of China and related department, and thus must be beneficial to the clinical verification and popularization of large-scale nuclear medicine image equipment.

SELECTION OF CITATIONS
SEARCH DETAIL