Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Journal of Biomedical Engineering ; (6): 265-271, 2023.
Article in Chinese | WPRIM | ID: wpr-981538

ABSTRACT

Closed-loop transcranial ultrasound stimulation technology is based on real-time feedback signals, and has the potential for precise regulation of neural activity. In this paper, firstly the local field potential (LFP) and electromyogram (EMG) signals of mice under different intensities of ultrasound stimulation were recorded, then the mathematical model of ultrasound intensity and mouse LFP peak/EMG mean was established offline based on the data, and the closed-loop control system of LFP peak and EMG mean based on PID neural network control algorithm was simulated and built to realize closed-loop control of LFP peak and EMG mean of mice. In addition, using the generalized minimum variance control algorithm, the closed-loop control of theta oscillation power was realized. There was no significant difference between the LFP peak, EMG mean and theta power under closed-loop ultrasound control and the given value, indicating a significant control effect on the LFP peak, EMG mean and theta power of mice. Transcranial ultrasound stimulation based on closed-loop control algorithms provides a direct tool for precise modulation of electrophysiological signals in mice.


Subject(s)
Mice , Animals , Deep Brain Stimulation , Algorithms , Electromyography
2.
Chinese Journal of Medical Instrumentation ; (6): 173-175, 2018.
Article in Chinese | WPRIM | ID: wpr-689840

ABSTRACT

This paper proposes a clinical alarm management system based on the theory of the closed loop control. The alarm management mechanism can be divided into the expected standard, improving execution rule, rule execution, medical devices with alarm functions, results analysis strategy and the output link. And, we make relevant application and discussion. Results showed that the mechanism can be operable and effective.


Subject(s)
Clinical Alarms , Decision Support Systems, Clinical
3.
Neumol. pediátr. (En línea) ; 12(2): 49-54, abr. 2017. ilus, tab, graf
Article in Spanish | LILACS | ID: biblio-999033

ABSTRACT

Pediatric sleep medicine has shown a considerable development during the last decades; however, sleep disorders epidemiology is varied and limited, mainly by the various definitions used. This articucle refers to prevalence data obtained by studies that include medical history, questionnaires and/or sleep studies. It includes the analysis of factors that may influence its epidemiology: age, gender, obesity, prenatal factores, ethnicity, socieconomic status and influence of some respiratory diseses susch as asthma and rhinitis. In addiction, aspects related to the natural evolution of respiratorty sleep disorders are described


La medicina del sueño pediátrica ha avanzado considerablemente durante las últimas décadas; sin embargo la evidencia epidemiológica es variada y limitada, principalmente por las diversas definiciones empleadas. El presente artículo profundiza sobre aspectos de prvalencia mediante estudios de anamnesis, cuestionarios y/o estudios de sueño; se incluye el análisis de factores que pueden influir en su epidemiología; edad, género, obesidad, factores prenatales, etnia genética, nivel socioeconómico e influencia de algunas enfermedades respiratorias como asma y rinitis. Adicionalmente, se describen aspectos relacionados con la evolución natural de los trastornos respiratorios del sueño


Subject(s)
Humans , Male , Female , Child , Sleep Apnea, Obstructive , Sleep Apnea Syndromes/epidemiology , Socioeconomic Factors , Sex Factors , Hoarseness/epidemiology , Prevalence , Age Factors , Environment , Overweight/complications , Obesity/complications , Obesity/epidemiology
4.
Chinese Medical Equipment Journal ; (6): 42-44,51, 2017.
Article in Chinese | WPRIM | ID: wpr-699854

ABSTRACT

Objective To design an integration system for use,supervision and intervention of antimicrobials to strengthen the management and improve the rationality in clinical use.Methods By using the computer technology and closed-loop control principle,the knowledge base and rule base were established to realize the integration for use,supervision and intervention of antimicrobials.The statistical analysis platform was also built to complete the statistical analysis and traceability of the used antimicrobial by different levels of hospitals,departments and doctors.Results The system achieved a full range of guidelines for the clinical use of antimicrobials.The waste of medical resources was suppressed and the adverse reactions and medical cost were also reduced.Conclusion The system has friendly interface and simple operation,which provides an effective solution for the rational use of antimicrobials.

5.
Journal of China Medical University ; (12): 746-749, 2017.
Article in Chinese | WPRIM | ID: wpr-668122

ABSTRACT

Objective To evaluate and compare the effectiveness of propofol-remifentanil closed-loop and open-loop anesthesia in gynecological laparoscopic operation under bispectral index (BIS) monitoring.Methods Forty female patients undergoing elective gynecological laparoscopic operation were recruited and randomly divided into closed-loop (group Ⅰ) and open-loop (group Ⅱ) groups.During anesthesia maintenance,the closed-loop group was administered with a BIS-feedback system to regulate the target effect-site concentration;whereas,the open-loop group was administered the target effect-site concentration according BIS value manually.The variation of non-invasive mean arterial pressure (MAP),heart rate (HR),SpO2,BIS,extubation time,consumption of propofol and remifentanil,Ramsay index,and subjective comfort grade were recorded at the selected time points.Results The extubation time in group Ⅰ was shorter than in group Ⅱ.The total dosage of propofol administered in group Ⅰ was less than that in group Ⅱ,but there was no significant difference in the total consumption of remifentanil.HR in group Ⅰ was steadier than in group Ⅱ.However,the MAP and Ramsay index were similar in both the groups.The subjective comfort grade in group Ⅰ was higher than in group Ⅱ.Conclusion The use of propofol-remifentanil closed-loop system by BIS-feedback anesthesia is safer,more controllable,with higher degree of satisfaction and sparing side-effects,we therefore recommend it during gynecological laparoscopic operations.

6.
Neumol. pediátr. (En línea) ; 11(4): 151-154, oct. 2016.
Article in Spanish | LILACS | ID: biblio-835073

ABSTRACT

This review is a short history of mechanical ventilation, from its origins to the present day. This changing history provides the basis for speculation on the future innovations in the ventilatory support.


Se revisa la historia de la ventilación mecánica desde sus orígenes hasta el presente, una historia cambiante que permite especular sobre las futuras innovaciones en el soporte ventilatorio.


Subject(s)
History, 19th Century , History, 20th Century , Positive-Pressure Respiration/history , Ventilators, Negative-Pressure/history , Respiration, Artificial/history
7.
Clinical Medicine of China ; (12): 277-279, 2016.
Article in Chinese | WPRIM | ID: wpr-488522

ABSTRACT

Ideal blood glucose control requires accurate insulin injections under the guidance of frequent glucose monitoring.Artificial pancreas (AP),the closed-loop control system can adjust the input amount of insulin automatically with the body's blood glucose levels.The AP allows diabetics to control blood glucose ideal,then get the benefit of prevention of complications and bring convenience and safety in clinical application.Accuracy is the key issue of the AP.To improve the accuracy of such a system need to improve the detection accuracy and reliability,increase speed and accuracy of the output control,and improve the accuracy of the system regulation model.

8.
Modern Hospital ; (6): 136-139, 2015.
Article in Chinese | WPRIM | ID: wpr-499524

ABSTRACT

Objective Improving the hospital operation management , preparing for the establishment of the digital operation room and achieving the fine management goal .Methods Based on the actual medical and clinical demand, combined with the standard of the operation management , designed and analyzed the management rules and processes of the perioperative information management system .Results Straightened out the information management rules and procedures of the operation room , strengthened the communication , feedback and sharing of the periopera-tive medical information , and improved the work efficiency , the operation quality and the utilization rate of the opera-tion room.Conclusion The smooth management process and the efficient use of information are the keys to promote the hospital management by means of informationization .

9.
China Medical Equipment ; (12): 43-45,46, 2014.
Article in Chinese | WPRIM | ID: wpr-600192

ABSTRACT

Objective:In the clinical mechanical ventilation practice, the medical workers often set the ventilator parameters only depend on their own experience. In order to change that,we design a Closed-Loop Automatic Mechanical Ventilation Controller.Methods: Design two closed-loop control subsystems to meet the requirements of closed-loop control system. PETCO2 control subsystem used to keep the concentration of PETCO2, and another subsystem design to regulate the respiratory elasticity called PEEP control subsystem. PETCO2 control subsystem can work on its own or work with PEEP control subsystem.Results: Using this closed-loop controller, the partial CO2 pressure and respiratory elasticity of patient was regulated in real time.Conclusion:By using this closed-loop automatic mechanical ventilation controller, the respiratory elasticity was largely reduced with the adequate gas exchange. Therefore, the ventilator using this closed-loop automatic mechanical ventilation controller can improve the ventilation quality and also reduce the risk of lung injury.

SELECTION OF CITATIONS
SEARCH DETAIL