Results 1 - 12 de 12
Filter
1.
International Eye Science ; (12): 920-923, 2019.
Article in Chinese | WPRIM | ID: wpr-740488

ABSTRACT

@#AIM: To explore the effects of femtosecond laser and mechanical lamellar blade excision laser <i>in situ</i> keratomileusis(LASIK)on corneal flap thickness stability and dry eye syndrome.<p>METHODS: Retrospective analysis of 80 patients with myopia who underwent LASIK in our hospital. According to different methods of flapping, it is divided into femtosecond laser group and mechanical laminating knife group. The flap thickness of the two groups of patients at different time points(1h, 1d, 1wk, 1mo, 3mo)were measured. The differences in corneal apex 1, 2, 3mm and corneal apex flap thickness in different directions were compared. The incidence of dry eye syndrome was compared between 1 and 3mo, 1a, 2a after surgery.<p>RESULTS: The apex thickness of the corneal flap of the femtosecond laser group is 99.62±4.50μm, and the thickness of the apex of the mechanical lamellar knife group is 125.25±12.81μm.The thickness of the corneal flap at different centrifugal points of the femtosecond laser flap is relatively uniform, while the thickness of the corneal flap of the mechanical lamellar knife varies greatly. The OSDI scores of the mechanical lamellar group were higher than those of the femtosecond laser group at 1, 3, 1, and 2a postoperatively(<i>P</i><0.01). At 2a of follow-up, the incidence of dry eye in the femtosecond laser group was lower than that in the mechanical lamellar group(χ<sup>2</sup>=4.692, <i>P</i>=0.030). At 1 and 2a postoperatively, the proportion of mild dry eye in the femtosecond laser group was higher than that in the mechanical lamellar group(<i>P</i>=0.044, 0.001).<p>CONCLUSION: Compared with the mechanical lamellar scalpel, the corneal flap thickness of patients with femtosecond laser LASIK is better, more uniform and less error. And the incidence of dry eye after surgery is lower, with mild dry eyes.

2.
International Eye Science ; (12): 894-896, 2018.
Article in Chinese | WPRIM | ID: wpr-695334

ABSTRACT

AIM: To study and compare the influence situation of corneal flap made by microkeratome and femtosecond laser for the vision and corneal flap thickness in patients. METHODS:Totally 120 patients(240 eyes) with myopic refractive surgery in our hospital from June 2014 to May 2015 were randomly divided into Group A (microkeratome group) with 60 cases (120 eyes) and Group B (femtosecond laser group) with 60 cases (120 eyes). Then the vision situation and corneal flap thickness indexes of two groups at different time after the treatment were compared. RESULTS:The vision situation between the two groups at different time after the treatment all had no significant differences (all P>0.05),while the corneal flap thickness related indexes of Group B at different time after the treatment were all better than those of Group A (all P<0 05). The evaluation indexes of two groups after the treatment all had significant differences (all P<0.05). CONCLUSION: The indexes of corneal flap made by femtosecond laser are better than those of microkeratome,and the influence of two methods for the vision is no obvious.

3.
International Eye Science ; (12): 1857-1859, 2014.
Article in Chinese | WPRIM | ID: wpr-642030

ABSTRACT

AIM:To discuss the related factors that affected the stability of posterior corneal surface after laser in situ keratomileusis ( LASIK) . METHODS:About 64 patients (64 eyes) were enrolled. The correlation among the changes in posterior corneal surface 6 month after LASIK, surgery method, corneal flap thickness ( FT ) , ablation thickness ( AT ) , postoperative residual corneal stroma thickness ( RCST ) , preoperative thinnest corneal thickness ( CT ) , flap thickness/preoperative thinnest corneal thickness ( FT/CT ) , ablation thickness/preoperative thinnest corneal thickness ( AT/CT) , postoperative residual corneal stroma thickness/preoperative thinnest corneal thickness ( RCST/CT) , anterior and posterior preoperative corneal height, the difference of the forward shift in posterior corneal surface ( diff value ) of preoperative and preoperative intraocular pressure were analyzed. RESULTS: The changes of diff value between preoperative and postoperative were related with diopter (r=0.419, P=0.014), AT (r=0.394, P=0.023), AT/CT (r=0.501, P=0.004), Diff value of preoperative (r=0.501, P=0. 004), RCST (r=-0. 385, P=0. 033) and RCST/CT (r=-0. 401, P=0. 025). The changes of height value from posterior corneal surface between preoperative and postoperative were related with diopter (r=0. 520, P=0. 002), AT (r=0.504, P=0. 003), AT/CT (r=0. 442, P=0. 013), Diff value of preoperative (r=0. 624, P=0. 000) and RCST/CT (r=-0. 394, P=0. 028). CONCLUSION: AT, RCST, AT/CT, RCST/CT and diff value of preoperative should be the key index that predicted the stability of posterior corneal surface after LASIK,the further research will give the range of safety value.

4.
Korean Journal of Ophthalmology ; : 8-14, 2011.
Article in English | WPRIM | ID: wpr-121944

ABSTRACT

PURPOSE: To evaluate factors responsible for the variability between intended and achieved corneal-flap thickness during femtosecond laser-assisted laser in situ keratomileusis (LASIK). METHODS: A prospective, nonrandomized, case study was performed on 35 eyes of 18 consecutive patients who underwent LASIK surgery using the 60 kHz femtosecond laser microkeratome. Eyes were assigned to three different thickness groups, with 110-, 120-, or 130-microm cut depths. Anterior segment optical coherence tomography was used to assess the morphology of 35 LASIK flaps at postoperative one week postoperatively. The flap thickness was assessed at seven measuring points across each flap. Patient age, preoperative spherical equivalent, manual keratometry, preoperative central pachymetry, and regional variability of the cornea were evaluated to determine where they influenced the achieved corneal flap thickness. RESULTS: Cuttings of all flaps were easily performed without any intraoperative complications. Flap-thickness measurements had a mean of 115.21 +/- 4.98 microm (intended thickness, 110 microm), 121.90 +/- 5.79 microm (intended, 120 microm), and 134.38 +/- 5.04 microm (intended, 130 microm), respectively. There was no significant difference between the 110-microm and 120-microm groups when compared with the 130-microm group (one-way analysis of variance test, p > 0.05). Patients' age, preoperative spherical equivalent, manual keratometry, and preoperative central pachymetry did not affect the achieved flap thickness (Pearson correlations test, p > 0.05). The reproducibility of flap thickness in the central 1.5-mm radius area was more accurate than that in the peripheral 3.0 to 4.0-mm radius area (paired samples t-test, p < 0.05). CONCLUSIONS: Femtosecond laser-assisted LASIK is likely to reproduce a reliable thickness of the corneal flap, which is independent of corneal shape factors or refractive status. Future studies should focus on variations in corneal biomechanical factors, which may also play an important role in determining flap thickness.


Subject(s)
Adult , Female , Humans , Male , Young Adult , Cornea/surgery , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia/physiopathology , Postoperative Period , Prospective Studies , Refraction, Ocular , Surgical Flaps , Visual Acuity
5.
International Eye Science ; (12): 615-617, 2010.
Article in Chinese | WPRIM | ID: wpr-641836

ABSTRACT

AIM: To determine the effect of suction duration on thickness and diameter of corneal flap created by microkeratome in porcine eyes in laser in situ kerato-mileusis (LASIK).METHODS: Sixty porcine eyes were randomly assigned to three groups according to different suction durations: group 1 (10 seconds), group 2 (20 seconds), and group 3 (30 seconds). A Moria M2 microkeratome (Moria, France) with a 160μm head was used to create a corneal flap. Corneal flap thickness was measured by automated ultrasonic pachymetry, and the flap diameter was measured by a vernier caliper.RESULTS: The flap thickness of group 1, group 2 and group 3 was 146.05±13.46μm, 157.35±18.95μm and 169.25±21.02μm, respectively. There was a statistically significant difference among three groups (P=0.001). The mean flap diameter in groups 1, 2 and 3 was 8.63±0.19mm, 8.89±0.24mm and 9.06±0.18mm, respectively. A statisti-cally significant difference was found among groups (P<0.01).CONCLUSION: In LASIK in porcine eyes, an increase in suction duration resulted in a thicker and greater flap.

6.
Journal of the Korean Ophthalmological Society ; : 1630-1635, 2007.
Article in Korean | WPRIM | ID: wpr-15123

ABSTRACT

PURPOSE: To investigate the relationship among optical coherence tomography (OCT), ultrasound pachymetry, and Orbscan in central corneal thickness measurement and to evaluate the reproducibility of flap thickness using an IntraLase femtosecond laser. METHODS: Central corneal thickness was measured by OCT, ultrasound pachymetry, and Orbscan in 59 eyes of 30 patients before LASIK. After IntraLASIK, the corneal flap thickness measured using OCT was compared with the intended corneal flap thickness. RESULTS: Central corneal thickness measured by OCT was thinner than that measured by other instruments preoperatively, but there was no significant difference among these methods (p>0.01), and corneal thickness values obtained by ultrasound pachymetry and Orbscan correlated well with those obtained by OCT (r ranged from 0.804 to 0.889, p0.01). CONCLUSIONS: OCT is a relatively accurate instrument for measuring corneal thickness and can easily measure the corneal flap thickness after LASIK. Compared with the results of a previous study, the mean measured flap thickness in this study was more reproducible with the IntraLase femtosecond laser.


Subject(s)
Humans , Corneal Pachymetry , Keratomileusis, Laser In Situ , Tomography, Optical Coherence , Ultrasonography
7.
Journal of the Korean Ophthalmological Society ; : 607-612, 2006.
Article in Korean | WPRIM | ID: wpr-76581

ABSTRACT

PURPOSE: To identify factors that may be related to variations in corneal flap thickness in LASIK using the Moria M2 microkeratome. METHODS: The charts of patients having LASIK based on steep keratometry nomogram using Moria M2 microkeratome (head : 110 micrometer) and excimer laser (VISX STAR S2, USA) in our department of ophthalmology from March, 2003, to May 2005, were reviewed retrospectively. A total of 195 eyes were enrolled in the investigation. We analyzed relationship between corneal flap thickness and preoperative factors including central corneal thickness, steep keratometer, corneal diameter, suction ring using multiple regression analysis. RESULTS: Mean corneal flap thickness was 119.37+/-21.21 micrometer. There was a statistically significant positive correlation between flap thickness and central corneal thickness (p<0.05). No correlation was found between flap thickness and other preoperative factors including steep keratometer, corneal diameter and suction ring. CONCLUSIONS: Mean corneal flap thickness using the Moria M2 110 micrometer head was 119.37+/-21.21 micrometer, little thicker than our expectation. When surgery is performed based on steep keratometry nomogram using Moria M2 microkeratome, if intraoperative factors are excluded, there is a trend toward thicker flap thickness with thicker central corneal thickness, whereas steep keratometer, corneal diameter or suction ring have no influence on flap thickness.


Subject(s)
Humans , Head , Keratomileusis, Laser In Situ , Lasers, Excimer , Nomograms , Ophthalmology , Retrospective Studies , Suction
8.
Journal of Shanghai Jiaotong University(Medical Science) ; (6)2006.
Article in Chinese | WPRIM | ID: wpr-640512

ABSTRACT

Objective To analyze the corneal flap thickness in laser in situ keratomileusis(LASIK) using Moria M2 microkeratome and to identify the related factors. Methods Sixty patients with LASIK were divided into two groups: M2 90 group,using the Moria M2 90 microkeratome,n=30;M2 110 group,using the Moria M2 110 microkeratome,n=30.All were performed on both eyes with the right one treated first.Subtraction pachymetry was used to measure corneal flap thickness which was analyzed statistically with the data including age,preoperative corneal diameter,curvature,corneal thickness and refraction. Results In the 30 patients of M2 90 group,the mean corneal flap thickness of right eye and left eyes were(128.03?12.03)?m(105~156 ?m) and(123.40?12.38) ?m(92~147 ?m),respectively,and the corneal flap thickness were statistically different between the right and left eyes(P

9.
Journal of the Korean Ophthalmological Society ; : 1697-1703, 2005.
Article in Korean | WPRIM | ID: wpr-127737

ABSTRACT

PURPOSE: To evaluate the reproducibility of the flap thickness in LASIK using Moria M2 microkeratome and to examine the safety and the complication rate intraoperatively and postoperatively. METHODS: 92-Ninety-two consecutive eyes of 50 patients that received LASIK using the Moria M2 microkeratome were reviewed. The mean of the predictable corneal flap thickness was compared with the mean of the created corneal flap thickness, and intraoperative and postoperative complication and safety were evaluated. RESULTS: The average corneal flap thicknesses were 140+/-15.16 micrometer with 130 micrometer head and 108.01+/-16.72 micrometer with 110 micrometer head. There was no statistically significant correlation between the predictable corneal flap thickness and the created corneal flap thickness with the 130 micrometer head (p=0.001, one-sample t-test), but there was a stastistically significant correlation with the 110 micrometer head (p=0.573, one-sample t-test). CONCLUSIONS: The M2 Moria microkeratome created a desirable thickness with the 110 micrometer head, and we can expect postoperative stability of the remaining corneal thickness. The complication rate both intraoperatively and postoperatively was very low.


Subject(s)
Humans , Head , Keratomileusis, Laser In Situ , Postoperative Complications
10.
Korean Journal of Ophthalmology ; : 63-69, 2002.
Article in English | WPRIM | ID: wpr-197291

ABSTRACT

To purpose of this study was to evaluate complications of unintended thin corneal flap in laser in situ keratomileusis (LASIK), such as visual acuity and myopic regression, at the one year follow-up. We performed a study on 54 eyes, i.e. 27 patients, having LASIK. The eyes were split into two groups, group one, 27 eyes with unintended thin corneal flap with a thickness of 100 microm or less, and as a control group, 27 eyes with a thickness of 110 microm or more. The average corneal flap thicknesses of the two groups were 88.89 +/- 8.07 microm and 132.70 +/- 19.58 microm, respectively. With regard to postoperative complications, there were no statistical differences between the groups for: foreign bodies in aspects of the interface, mild peripheral infiltration, superficial punctuate keratitis, myopic regression and decreased vision. The only complication showing any statistical difference between the two groups was the central corneal opacity. An unintended thin corneal flap, with an intact Bowman's layer, induced no significant postoperative complications. Central corneal opacity was apparent in 4 of the eyes in group one, so may be related with a thin corneal flap.


Subject(s)
Adult , Humans , Comparative Study , Cornea/surgery , Corneal Opacity/etiology , Follow-Up Studies , Keratomileusis, Laser In Situ/adverse effects , Myopia/surgery , Postoperative Complications , Surgical Flaps/adverse effects , Treatment Outcome , Visual Acuity
11.
Journal of the Korean Ophthalmological Society ; : 1133-1137, 2002.
Article in Korean | WPRIM | ID: wpr-99473

ABSTRACT

PURPOSE: The purpose of this study is to investigate the effect of the suction time in forming the corneal flap with microkeratome on the corneal flap thickness. METHODS: Thirty porcine eyes were randomly assigned into 3 groups according to suction duration: group 1(10 sec), group 2(35 sec) and group 3(60 sec). The Hansatome microkeratome with 160 plate and a suction ring with 8.5mm diameter were used to create corneal flap. The thickness of central cornea was measured with automated ultrasound pachymeter before the procedure. And after making the flap, the remained corneal thickness was measured with the same method. Then, the difference between the two values was thought to be the corneal flap thickness. RESULTS: The mean corneal flap thickness in group1, 2, and 3 were 91.0+/-24.1 micromiter, 110.1+/-8.9 mu m and 127.2+/-6.1 mu m, respectively. The difference was significant among the three groups(p=0.010), and the longer suction duration made the flap thicker. CONCLUSIONS: These results suggest that in forming the corneal flap with microkeratome, the suction duration has an effect on the corneal flap thickness and an increase of suction duration makes the flap thicker in porcine eyes.


Subject(s)
Cornea , Suction , Ultrasonography
12.
Journal of the Korean Ophthalmological Society ; : 1331-1336, 2000.
Article in Korean | WPRIM | ID: wpr-161990

ABSTRACT

To evaluate the consistency of the thickness and size of the corneal flap made by the Innovatome automatic microkeratome and to determine the cor-relation between preoperative variables and corneal flap dimensions, we per-formed the prospective study comprised 102 consecutive eyes of 51 patients having laser in-situ keratomileusis (LASIK)with the Innovatome microker-atome.Central corneal thickness, corneal curvature, and refractive error were measured preoperatively.All flaps were created using No.170 blades. The mean corneal flap thickness was 139.70 +/-2 2.5 6 micrometer, and the range was 93.0 ~193.7 micrometer.There was no relationship between the corneal flap thickness and the preoperative corneal curvature or spherical equivalent, but the corneal flap thickness increased with the preoperative central corneal thickness. The mean corneal flap size (vertical diameter)was 9.17 +/- 0.25 mm (range :8.5 0 ~9.7 5 mm).There was no relationship between the corneal flap diameter and the preoperative central corneal thickness or spherical equivalent, but the corneal flap size increased with the preoperative corneal curvature.


Subject(s)
Humans , Keratomileusis, Laser In Situ , Prospective Studies , Refractive Errors
SELECTION OF CITATIONS
SEARCH DETAIL