Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add filters








Year range
1.
Chinese Journal of Biologicals ; (12): 419-2023.
Article in Chinese | WPRIM | ID: wpr-976171

ABSTRACT

@#ObjectiveTo establish the national reference panel for coxsackievirus A16(CA16)nucleic acid detection kit and related quality standard.MethodsThe CA16 positive and negative samples were collected and screened,and then were filled and lyophilized to establish the national reference panel for CA16 nucleic acid detection kit. According to the cooperative calibration results of various reagent manufacturers,the quality standard of reference panel was determined.Meanwhile,the homogeneity and stability of the national reference panel were well studied.ResultsThe national reference panel of CA16 nucleic acid detection kit consisted of 9 positive samples,8 negative samples,1 limit-detecting sample and1 precision sample. The quality standard was as follows:the coincidence rate of positive samples was no less than 8/9;The coincidence rate of negative samples was 8/8;The minimum detection limit required that the dilution of limit-detecting sample was no less than 1∶103;The precision required that the coefficient of variation(CV)of Ct value of 10 precision samples diluted 100 times was no higher than 5% and the results were all positive. The homogeneity of the reference panel met the requirement,and the stability was not affected by the storage at room temperature(25 ℃)for 24 hours and repeated freezing and thawing three times.ConclusionThe first national reference panel of CA16 nucleic acid detection kit and the related quality standard have been established,which provided a reference for the quality control and evaluation of the related reagents.

2.
Laboratory Medicine Online ; : 17-21, 2019.
Article in Korean | WPRIM | ID: wpr-719666

ABSTRACT

Viral respiratory infections are one of the most common infections worldwide. It is important to detect the virus early and precisely. In this study, we evaluated the limit of detection (LoD) and usefulness of the Real-Q RV Detection kit (BioSewoom, Seoul, Korea). We measured the LoD of the Real-Q RV Detection kit using 10 strains of standard viruses. We then compared the detection results by the Allplex Respiratory Panel Assay kit (Seegene, Seoul, Korea) using 123 clinical specimens. The discrepant results were confirmed by sequencing. Among the 10 standard viruses, the LoD of human rhinovirus (HRV) was the lowest and that of parainfluenza virus 2 and 3 was relatively high as detected by Real-Q RV Detection kit. Agreements of the two kits ranged from 95.9% to 100%. Three specimens detected negative by the Allplex Respiratory Panel kit were detected as adenovirus (AdV) by the Real-Q RV Detection kit and were confirmed by sequencing. Similarly, a specimen detected negative by the Allplex Respiratory Panel kit was detected as HRV by the Real-Q RV Detection kit and was confirmed by sequencing. A specimen detected as human enterovirus by the Allplex Respiratory Panel kit was detected as HRV by the Real-Q RV Detection kit and was confirmed by sequencing. Real-Q RV Detection kit showed good diagnostic performance and can be useful for detecting major viruses that cause respiratory infections.


Subject(s)
Humans , Adenoviridae , Enterovirus , Limit of Detection , Paramyxoviridae Infections , Respiratory Tract Infections , Rhinovirus , Seoul
3.
Chinese Journal of Endemiology ; (12): 489-492, 2019.
Article in Chinese | WPRIM | ID: wpr-753531

ABSTRACT

Objective To evaluate the clinical application effect of a specific antibody detection kit for human echinococcosis (hydatidosis kit),and provide technical support for further optimization of the production process of hydatidosis kit.Methods Using the method of retrospective investigation,1 481 patients with hydatidosis and 1 055 no-hydatidosis patients who were diagnosed by operation,pathology (gold standard) and hydatidosis kit in First Affiliated Hospital of Xinjiang Medical University,from 2012 to 2016 were selected.The clinical data was analyzed.The diagnostic performance of the kit was evaluated.The stepwise discriminant analysis method was applied to construct discriminant analysis function and establish a diagnostic model for echinococcosis.The detection efficiency of four antigens in hydatidosis kit was analyzed.Results A total of 2 536 patients [1 275 males,1 261 females,aged (41.62 ± 18.43) years old] were investigated,with the highest proportion in the 30-59 age group (1 489cases).Liver was the main organ affected by echinococcosis.The sensitivity,specificity and consistency of the hydatidosis kit were 94.80% (1 404/1 481),71.00% (749/1 055),and 84.90% (2 153/2 536),Yoden index was 0.66 and Kappa value was 0.68.The stepwise discriminant analysis function Y =0.777X1 + 0.258X2 + 0.241X3-1.575 was constructed by the stepwise discriminant analysis method.There was no significant difference between the consistency of stepwise discriminant analysis model and the current diagnostic criteria (85.73% vs 84.90%,x2 =0.694,P > 0.05).The consistency of differential diagnosis between vesicular and cystic echinococcosis was 76.07% (1 068/1 404).There was no significant difference in the detection efficacy between Echinococcus granulosus cystic fluid antigen (EgCF) and hydatidosis kit (P > 0.05).Conclusions The diagnosis and differential diagnosis efficiency of hydatidosis kit is high.It is suitable for clinical diagnosis and field epidemiological investigation of echinococcosis in hospitals at all levels.EgCF can be used as the antigen of echinococcosis monoantigen strip,and can be applied in the epidemiological investigation of echinococcosis.

4.
Chinese Pharmaceutical Journal ; (24): 306-311, 2018.
Article in Chinese | WPRIM | ID: wpr-858427

ABSTRACT

OBJECTIVE: To develop a DNA detection kit for identification of Fetus Cervi, evaluate the quality indexes including specificity, stability, sensitivity and repeatability, and inspect the qualities of commercial Fetus Cervi samples. METHODS: The Fetus Cervi DNA test kit was developed and modified using the classical DNA extraction and PCR identification method. The genomic DNAs of Fetus Cervi and counterfeit goods were extracted by the kit and PCR technique was performed to identify the authenticity. The purity of DNA was detected by UV spectrophotometer. Finally, commercially available Fetus Cervi samples were verified. RESULTS: The kit was proved to be effective after 20 times of repeated frozen-thawing and it could be stored at - 20℃ for 1 year. The DNA could be detected when the primary solution was diluted by 200 times. The specificity test confirmed that the 15 samples were authentic Fetus Cervi, and 7 were counterfeit. The specificity of the kit was 100%. The repetitive experiments showed that the average intra-assay CV% and inter-assay CV% of the kit were 2.32% and 2.56%, respectively. CONCLUSION: The amount and purity of the nucleic acids extracted by the DNA detection kit can meet the requirement for identification of Fetus Cervi, and the kit has good specificity, high sensitivity and good stability, so it is suitable for the rapid detection of Fetus Cervi.

5.
China Journal of Chinese Materia Medica ; (24): 1125-1129, 2017.
Article in Chinese | WPRIM | ID: wpr-350215

ABSTRACT

Ophiocordyceps sinensis is a valuable traditional Chinese medicine. Due to resource shortage, expensive price and huge market demand, there are many adulterants of O. sinensis in markets. Therefore, it is necessary to establish a rapid and effective method for distinguishing O. sinensis. Based on the species-specific PCR of O. sinensis, this study developed a detection kit by optimizing the components and evaluated the specificity, detection limit, repeatability and shelf life of the kit. The results showed that when the quality of O. sinensis accounted for more than 1/200 of that mixture, it could be detected successfully. Moreover, only O. sinensis could be amplified and glowed bright green fluorescence under ultraviolet light. The kit was still in effect when it was placed at 37 ℃ for three days, which indicated that it was stable and effective for one year stored in 4 ℃. The kit in the same batch under different operation conditions, and in different batch under the same operation conditions gave the same result and accuracy, which showed good repeatability of the kit. It is simple, rapid and accurate to distinguish O. sinensis from its adulterants using the kit, and lays the foundation for commercialization of traditional Chinese medicine fast detection kit.

6.
Chinese Pharmaceutical Journal ; (24): 616-619, 2016.
Article in Chinese | WPRIM | ID: wpr-859136

ABSTRACT

OBJECTIVE: To establish a standard method for preserving the Fritillaria cirrhosa D. Don DNA fingerprint fragments. METHODS: Independently developed F. cirrhosa test kit was used to extract genomic DNA. Specific F. cirrhosa DNA fragments were cloned in vitro, and ligated into a carrier vector then transformed into a self replicating host cells to produce a large amount of specific F. Cirrhosa DNA. Plasmid DNA was extracted using Plasmid Extraction Kit and confirmed by PCR or restriction digestion of the insert. Bacterial colonies carrying authentic Sichuan F. cirrhosa specific DNA sequences were stored at -80℃. Stability was monitored at intervals of 1, 2, 3 and 6 months after DNA recovery using the boiling method of genomic DNA extraction. RESULTS: The amplified F. cirrhosa DNA clones showed clear bands in the electrophoresis, and had stable results in the repeated verification test. The amplified clones from resuscitated bacterial colonies which had been stored for 1, 2, 3, 6 months at -80℃ still displayed bright and clear bands after electrophoresis. CONCLUSION: It is feasible and effective to preserve DNA fingerprint of F. Cirrhosa by the established method, and this simple and reliable method can be used as the basis of establishing the new genes database of traditional Chinese medicine.

7.
Chinese Pharmaceutical Journal ; (24): 1866-1870, 2016.
Article in Chinese | WPRIM | ID: wpr-858924

ABSTRACT

OBJECTIVE: To develop a rapid DNA detection kit for DNA extraction and PCR identification of Panax ginseng C. A. Mey. METHODS: The classical DNA extraction and PCR identification methods for Panax ginseng C. A. Mey were modified, and the compositions and reaction conditions of the kit were determined. In addition, the specificity, stability, sensitivity, and repeatability of the kit were evaluated. The genomic DNAs of genuine and counterfeit ginseng goods were extracted by the kit and PCR was performed to identify the authenticity. The purity of the extracted DNA was detected by UV spectrophotometry. Finally, commercially available ginseng samples were verified. RESULTS: The purity of the genomic DNA extracted by the kit was (1.73 ± 0.13) (OD260/OD280), and a fragment between 150 and 200 bp could be amplified only from authentic Panax ginseng C. A. Mey. The specificity of the kit was 100%. The repetitive experiments showed that the average intra-assay CV% and inter-assay CV% of the kit were 2.38% and 2. 62%, respectively. The DNA in solutions diluted by 200 times could still be detected. Stability experiment proved that repeated freeze-thawing for 20 times had no significant effect on the activity of this kit and the test sample could be stored at - 20℃ for one year. The specificity test confirmed that 8 samples among the 10 commercial products were genuine, and 2 were counterfeit. CONCLUSION: The nucleic acid extraction and purity of the DNA detection kit can meet the requirement for identification of Panax ginseng C. A. Mey. The kit has good specificity, high sensitivity, and good stability, so it is suitable for the rapid detection of Panax ginseng C. A. Mey.

8.
Journal of Medical Biomechanics ; (6): E074-E082, 2015.
Article in Chinese | WPRIM | ID: wpr-804415

ABSTRACT

Objective To investigate the effect of 1,25-(OH)2-vitamin D3 (VD3) or mechanical strain alone and their combined treatment on proliferation and differentiation of pre-osteoblast MC3T3-E1 cells in vitro, as well as gene and protein expression of osteoprotegerin (OPG) and receptor activator of nuclear factor-кB ligand (RANKL) in those cells. Methods MC3T3-E1 cells were treated with 10 nmol/L VD3, intermitted mechanical strain or with a combination of these two factors. Cell proliferation was assessed with flow cytometry, and alkaline phosphatase (ALP) activity was measured using a fluorometric detection kit. The mRNA expression of ALP, runt-related transcriptional factor 2 (Runx2), OPG, and RANKL genes was determined by real-time PCR. The proteins expression of Runx2, OPG, and RANKL was determined by Western blotting. ResultsVD3 inhibited the proliferation of MC3T3-E1 cells, but the mechanical strain had no effect on cell proliferation. Mechanical strain, VD3, and the combined treatment enhanced the ALP activity of MC3T3-E1 cells as well as the protein expression of Runx2. The effect of combined treatment was less pronounced than the effect of VD3 or mechanical strain alone. Mechanical strain promoted the gene and protein expression of osteoprotegerin (OPG) and increased the ratio of OPG/RANKL. However, the combination of VD3 and mechanical strain led to a decrease in ratio of OPG/RANKL. Conclusions Mechanical strain might be effective in inducing osteogenic differentiation and increasing bone formation. A joint stimulation with VD3 and strain can decrease proliferation and osteogenic differentiation and increase RANKL expression, which might affect bone remodeling. This study supplies some new data, which might be important in theoretical and clinical research of osteoporosis (OP) and other related bone diseases.

9.
Chinese Journal of Immunology ; (12): 644-647, 2014.
Article in Chinese | WPRIM | ID: wpr-448439

ABSTRACT

Objective:To establish the detection method of double-antibody sandwich ELISA about CYFRA 21-1 in human ser-um.Methods:The paired antibody were screened among four strains mAbs of CYFRA 21-1, which was marked by sodium periodate method.The detecting method of double antibody sandwich ELISA was optimizted , and evaluated by specificity , stability and sensitivi-ty.Results:The results showed that a paired of antibody , which was 2F9 as the coated antibody and 6F11 as the labeled antibody, was selected from four mAbs .It was the optimum condition of double antibody sandwich ELISA that the coating antigen concentration of 2F9 was 0.50 μg/ml, while the labeled antibody of 6F11 was diluted 6 000 times.The linear range of standard curve was 0.7-25 ng/ml with r2 =0.990 8, while the limit of detection was 0.666 8 ng/ml, the recovery rate was 98.14%.The cross-reactions with the oth-er analogues in serum were less than 0.1%.The coefficient of variation in group (n=10) was 6.8%, whereas coefficient of variation among group(n=5) was 11.4%.The correlation compared with other foreign ELISA kit was 91.42%.Conclusion:In brief, we suc-cessfully established the method of double antibody sandwich ELISA detecting CYFRA 21-1 level in human serum , laying the foundation for the production of CYFRA21-1 ELISA kit.

10.
Chinese Pharmaceutical Journal ; (24): 501-504, 2014.
Article in Chinese | WPRIM | ID: wpr-859802

ABSTRACT

OBJECTIVE: To develop a kit for detection of DNA of Fritillaria cirrhosa D. Don and optimize its components as well as process protocols, in order to set up a simple, rapid molecular biology method for identification of Fritillaria cirrhosa D. Don. METHODS: All genomic DNA of Fritillaria cirrhosa D. Don was extracted by kit assay and pharmacopoeia method recorded in the expanded supplement of China Pharmacopoeia 2010, respectively; ultraviolet spectrophotometer was used to measure the quantity of extracted DNA; PCR amplification and restriction fragment length polymorphism analysis (RFLP) were carried out to identify the authentication of Fritillaria cirrhosa D. Don. RESULTS: The maximum value of genomic DNA extracted by pharmacopoeia method was (1.57±0.05) (OD260/OD280) and (1.73±0.10) by kit assay. The PCR amplification showed a single band over 300 bp, while the RFLP showed two distinct bands between 100 and 250 bp in agarose electrophoresis. CONCLUSION: The data demonstrated that the kit assay was better than the pharmacopoeia method, especially in the extraction quantity and DNA purity of Fritillaria cirrhosa D. Don nicleic acid; the PCR and RFLP results showed that the kit assay was consistent with pharmacopoeia method. The detection kit has good specificity, high sensitivity and good stability, so it is suitable for the rapid detection of Fritillaria cirrhosa D. Don.

11.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-588570

ABSTRACT

According to the needs of maintenances a detection kit for ECG cable is developed to detect the onoff condition of the wire, which can form a loop, and to indicate the result on a LED. The kit proves to be simple and practical and thus can significantly increase the maintenance efficiency of ECG cable.

SELECTION OF CITATIONS
SEARCH DETAIL