OBJECTIVE@#Aims researches on the interaction between heart valves is limited in clinical. Meanwhile the data of in vitro testing are insufficient. In this study, the in vitro hydrodynamic performance of an aortic valve was studied by using a model of mitral regurgitation that could finely adjust the regurgitant volume.@*METHODS@#The regurgitation of mitral valve was gradually increased under the certain condition of heart rate, stroke volume, and mean aortic pressure and captured the hydrodynamic performance of the aortic valve.@*RESULTS@#The study on the hydrodynamic performance of mechanical aortic valve (25AJ-501) by using a model of mitral regurgitation found that the effective orifice area and mean pressure difference of the aortic valve are negatively correlated with the degree of mitral regurgitation.@*CONCLUSIONS@#The method based on a model of mitral regurgitation that could finely adjust the regurgitant volume established in this study can be used to study the effect of mitral valve regurgitation on the hydrodynamic performance of the aortic valve.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 707-710, 2018.
Article in Chinese | WPRIM | ID: wpr-742568

ABSTRACT

@#Objective    To analyze the incidence of valve prosthesis-patient mismatch (PPM) and ventricular remodeling of elderly patients after aortic valve replacement (AVR). Methods    We retrospectively analyzed the clinical data of 134 patient aged over 65 years who underwent AVR for the aortic stenosis or regurgitation at our hospital between January 2016 and December 2016. There were 73 males and 61 females aged 69.7±3.6 years ranging from 65-79 years. The clinical and ultrasound cardiography data were evaluated. PPM was defined as an effective orifice area index (EOAI) of ≤ 0.85 cm2/m2. The incidence of PPM and the left ventricular remodeling after surgical AVR in the patients with aortic stenosis and aortic regurgitation was analyzed, and the outcomes of aortic valve mechanical prosthesis and aortic valve bioprosthesis were compared. Results    The incidence of PPM was 32.5% in aortic stenosis and 13.0% in aortic regurgitation (P<0.05). One patient died in the early post-operation, and the incidence of severe PPM was 6.0%. Conclusion    The incidence of PPM after AVR in the patients with aortic regurgitation is less than that in the patients with aortic stenosis.

3.
Chongqing Medicine ; (36): 2510-2512, 2016.
Article in Chinese | WPRIM | ID: wpr-492878

ABSTRACT

Objective To discuss the quality of life in the postoperative patients with aortic valve replacement (AVR) and related influencing factors .Methods The changes of preoperative and postoperative survival quality in 102 cases of AVR surgery were assessed by using the SF‐36 scale ,and the Logistic regression was used to analyze the impact of age ,effective valve orifice area and prosthetic valve on the quality of life .Results Five patients died during follow‐up .The relative baseline survey after postopera‐tive 1 year showed that the quality of life of patients was significantly improved ,the Logistic regression analysis revealed that a lar‐ger effective orifice area(EOA) and biological valve replacement could have higher health scale scores ,and showed a positive corre‐lation .Conclusion The quality of life in the postoperative patients with AVR is affected by the valve type and EOA of prosthetic valve .

4.
Tianjin Medical Journal ; (12): 776-779, 2016.
Article in Chinese | WPRIM | ID: wpr-493755

ABSTRACT

Objective To evaluate the short term outcome after mitral valve replacement with the Perimount bovine pericardial valve. Methods Eighty-eight patients underwent mitral valve replacement with the bovine pericardial valve in hospital were included in this study. Postoperative general condition including mortality and cerebral hemorrhage was observed. The hemodynamic and New York heart disease association (NYHA) heart function classification were recorded by Doppler echocardiograms before operation, postoperative 1 week, 3 months and 1 year after mitral valve replacement. Values of the different time points of NYHA, left atrial diameter (LA), left ventricular end diastolic diameter (LVDD), left ventricular end systolic diameter (LVSD), left ventricular ejection fraction (LVEF) and pulmonary artery pressure (PAP) were compared. The hemodynamic parameters were also compared including the peak cross valve pressure (PG), mean cross valve pressure (MG), peak cross valve velocity (PV) and effective orifice area (EOA) 1 week, 3 months and 1 year after surgery. Results There were two cases (2.3%) dead in one year (one died of cerebral hemorrhage and another one died of thromboembolism). There was 1 perivalvular leakage (1.2%). There was no endocarditis or structural valve deterioration. NYHA cardiac function was improved at postoperative 3 months and 1 year (P < 0.05). The values of LA, LVDD and PAP were significantly decreased at postoperative 1 week, 3 months and 1 year compared with those before operation (P<0.05). Values of LVSD and LVEF were significantly decreased at postoperative 1 week compared with those before operation (P<0.05). The value of LVEF was significantly increased at postoperative 3 months and 1 year (P<0.05). Compared with postoperative 1 week, the values of LA and LVEF were significantly increased at postoperative 3 months and 1 year (P < 0.05). There were no significant differences in PG, MG, PV and EOA between postoperative 1 week, 3 months and 1 year. Conclusion With the excellent performance of cardiac function recovery, left ventricular restoration and hemodynamic, the Perimount bovine pericardial valve remains a reliable choice as a mitral tissue valve.

5.
Japanese Journal of Cardiovascular Surgery ; : 81-85, 2011.
Article in Japanese | WPRIM | ID: wpr-362067

ABSTRACT

This study compared the hemodynamic performance of the Carpentier-Edwards PERIMOUNT Magna bioprosthesis (Magna) with the Carpentier-Edwards PERIMOUNT bioprosthesis (CEP) for aortic valve stenosis (AS). Between January 2005 and May 2010, 164 patients underwent aortic valve replacement for AS with either the Magna (<i>n</i>=68) or the CEP (<i>n</i>=96) at our institute. Patients undergoing a concomitant mitral valve procedure were excluded from this study. The 21-mm Magna and CEP prostheses were the most frequently used during this period. Transthoracic echocardiography was postoperatively performed within 2 weeks. The peak velocity (PV) of the Magna was significantly lower than that of the CEP (2.59±0.36 vs. 2.75±0.47 m/s ; <i>p</i>=0.022). The mean pressure gradient (PG) was not significantly different. For the 19-mm prostheses, the mean PG and PV of the Magna were significantly lower than those of the CEP [16.4±4.5 vs. 19.7±6.4 mmHg ; <i>p</i>=0.034 (PG) and 2.70±0.36 vs. 3.03±0.49 m/s ; <i>p</i>=0.008 (PV)]. The effective orifice area (EOA) of the Magna was larger than that of the CEP [19 mm : 1.29±0.18 vs. 1.11±0.24 cm<sup>2</sup> (<i>p</i>=0.007) ; 21 mm : 1.46±0.23 vs. 1.42±0.18 cm<sup>2</sup> (<i>p</i>=0.370) ; and 23 mm : 1.70±0.34 vs. 1.52±0.25 cm<sup>2</sup> (<i>p</i>=0.134)]. In this study, the EOA of the Magna was approximately 80% of that described in the manufacture's description. Patient-prosthesis mismatch (PPM ; EOA index≤0.85 cm<sup>2</sup>/m<sup>2</sup>) was seen in 26.8% of patients with the Magna and in 47.2% of patients with the CEP (<i>p</i>=0.018). Severe PPM (EOA index≤0.65 cm<sup>2</sup>/m<sup>2</sup>) was not seen in any patients with the Magna. The EOA of the 19-mm Magna was significantly larger and the mean PG was lower than those of the 19-mm CEP. Compared with the CEP, the Magna significantly reduced the incidence of PPM, and had superior hemodynamic performance.