1.
Journal of Korean Medical Science ; : e154-2018.
Article in English | WPRIM | ID: wpr-714362

ABSTRACT

BACKGROUND: One of the key issues in electroencephalogram (EEG) monitoring is accurate signal acquisition with less cumbersome electrodes. In this study, the L2 phase electro-deposited nanoporous platinum (L2-ePt) electrode is introduced, which is a new type of electrode that utilizes a stable nanoporous platinum surface to reduce the skin-electrode impedance. METHODS: L2-ePt electrodes were fabricated using electro-deposition technique. Then, the effect of the nanoporous surface on the surface roughness and the electrode impedance were observed from the L2-ePt electrodes and the flat platinum (FlatPt) electrode. The skin-electrode impedances of the L2-ePt electrodes, a gold cup electrode, and the FlatPt electrode were evaluated when placed on the hairy occipital area of the head in ten subjects. For the validation of using the L2-ePt electrode, a correlational analysis of the alpha rhythms was performed in the same subjects for simultaneous EEG recordings using the L2-ePt and clinically-used EEG electrodes. RESULTS: The results indicated that the L2-ePt electrode with a roughness factor of 200 had the lowest mean impedance performance. Moreover, the proposed L2-ePt electrode showed a significantly lower mean skin-electrode impedance than the FlatPt electrode. Finally, the EEG signal quality recorded by the L2-ePt electrode (r = 0.94) was comparable to that of the clinically-used gold cup electrode. CONCLUSION: Based on these results, the proposed L2-ePt electrode is suitable for use in various high-quality EEG applications.


Subject(s)
Alpha Rhythm , Electric Impedance , Electrodes , Electroencephalography , Head , Platinum
2.
Journal of China Medical University ; (12): 533-537, 2015.
Article in Chinese | WPRIM | ID: wpr-468202

ABSTRACT

Objective To investigate the changes of electrode impedance,threshold(THR),maximum comfortable level(MCL),and dynamic range(DR),providing the basis for debugging after operation in congenital deaf children. Methods A respective study was carried out on 20 cases of congenital deaf children who were implanted with cochlear Med?EL SONATAti100. The measurements and changing ranges of electrode imped?ances,THR,MCL and dynamic range during the operation and at postoperative one month,three months,and six months were statistically analyzed. Results Electrode impedances were the lowest during the operation and the highest at one month after operation(P0.05). Conclusion The electrode impedances varied due to different electrode posi?tion. The vales of THR,MCL and DR were unrelated with electrode impedance. DR was gradually increasing,MCL reached steady state earlier than THR. It is important that THR should be debugged at three months after operation and MCL should be debugged at six months.

3.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-585192

ABSTRACT

In this paper, the structure, operational principle, clinical application of a novel pulse therapeutic apparatus are introduced. Controlled though a SCM, the apparatus can output biphasic constant current and special pulses for electrostimulation.With the electrode impedance measured automatically, the apparatus can be applied to the treatment and rehabilitation of several diseases of gynecology & Obstetrics.