Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Yonsei Medical Journal ; : 454-459, 2015.
Article in English | WPRIM | ID: wpr-141627

ABSTRACT

PURPOSE: The purpose of this study was to investigate the correlation between rotational axes of femur and tibia with the use of Linker. MATERIALS AND METHODS: This study was carried out from August 2009 to February 2010 on 54 patients (106 knees), who were diagnosed with simultaneous bilateral total knee arthroplasty. With the use of postoperative computed tomography scans, it was investigated how much the rotational angle of femoral and tibial components matched. RESULTS: The tibial component was internally rotated for the femoral component at an angle of 0.8degrees. The femoral component was externally rotated for the surgical transepicondylar axis (TEA) at an angle of 1.6 (range: from 4.8degrees of internal rotation to 7.9degrees of external rotation, SD=2.2degrees), and the tibial component was externally rotated for the surgical TEA at an average angle of 0.9 (range: from 5.1degrees of internal rotation to 8.3degrees of external rotation, SD=3.1degrees). CONCLUSION: The femoro-tibial synchronizer helped to improve the orientation and positioning of both femoral component and tibial component, and also increase the correlation of the rotational axes of the two components.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee/methods , Femur/diagnostic imaging , Knee , Knee Joint/diagnostic imaging , Knee Prosthesis , Reference Values , Rotation , Tibia/diagnostic imaging , Tomography, X-Ray Computed/methods
2.
Yonsei Medical Journal ; : 454-459, 2015.
Article in English | WPRIM | ID: wpr-141626

ABSTRACT

PURPOSE: The purpose of this study was to investigate the correlation between rotational axes of femur and tibia with the use of Linker. MATERIALS AND METHODS: This study was carried out from August 2009 to February 2010 on 54 patients (106 knees), who were diagnosed with simultaneous bilateral total knee arthroplasty. With the use of postoperative computed tomography scans, it was investigated how much the rotational angle of femoral and tibial components matched. RESULTS: The tibial component was internally rotated for the femoral component at an angle of 0.8degrees. The femoral component was externally rotated for the surgical transepicondylar axis (TEA) at an angle of 1.6 (range: from 4.8degrees of internal rotation to 7.9degrees of external rotation, SD=2.2degrees), and the tibial component was externally rotated for the surgical TEA at an average angle of 0.9 (range: from 5.1degrees of internal rotation to 8.3degrees of external rotation, SD=3.1degrees). CONCLUSION: The femoro-tibial synchronizer helped to improve the orientation and positioning of both femoral component and tibial component, and also increase the correlation of the rotational axes of the two components.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee/methods , Femur/diagnostic imaging , Knee , Knee Joint/diagnostic imaging , Knee Prosthesis , Reference Values , Rotation , Tibia/diagnostic imaging , Tomography, X-Ray Computed/methods
3.
Yonsei Medical Journal ; : 1505-1510, 2013.
Article in English | WPRIM | ID: wpr-100946

ABSTRACT

PURPOSE: We devised an intraoperatively identifiable mechanical axis (IIMA) as a reference of alignment in total knee arthroplasty (TKA). MATERIALS AND METHODS: Between February 2010 and January 2011, primary TKAs were consecutively performed on 672 patients (1007 knees) using an IIMA as a reference in the coronal plane. RESULTS: The alignment of the lower extremity improved from a mean of 11.4+/-6.7degrees (-10.3-34.4degrees) of varus preop. to 0.7+/-3.5degrees (-5.2-8.6degrees) immediately after surgery. Mean alignment of the femoral component in the coronal plane was 89.3+/-2.3degrees (83.4-97.2degrees) postop. and mean alignment of the tibial component was 90.4+/-2.2degrees (85.1-94.2degrees) postop. CONCLUSION: This study showed that IIMA could be of considerable value as a new guider of alignment that is easily accessible and highly effective during total knee arthroplasty.


Subject(s)
Humans , Arthroplasty, Replacement, Knee/methods , Femur/surgery , Tibia/surgery
SELECTION OF CITATIONS
SEARCH DETAIL