Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Chinese Medical Equipment Journal ; (6): 32-35, 2017.
Article in Chinese | WPRIM | ID: wpr-618968

ABSTRACT

Objective To discuss the practicability of application of fault tree analysis in innovation to electrical system of SL-IE radiotherapy simulator.Methods The structure and principle of the electrical system were analyzed,the fault tree for the electrical system was built,and the qualitative analysis and quantitative analysis to the fault tree were made.The electrical system was innovated with effective redundant method,and the qualitative analysis and quantitative analysis were made after innovation.Theoretical analysis and the actual validation were made for the fault tree of electrical system after innovation.Finally,several notes were provided for the innovation to the similar medical equipments.Results The fault tree analysis method was applied to innovating the electrical system,and theoretical analysis indicated that the failure probability to total system reduced obviously.Actually,the actual effect after innovation also validated the correctness of the theoretical analysis.Conclusion Application of fault tree analysis in innovation to electrical system of SL-IE radiotherapy simulator is practical.But,the selection to the innovation event,the change to maintainence after innovation and the event to innovate carefully should be paid attention to.

2.
Safety and Health at Work ; : 158-160, 2014.
Article in English | WPRIM | ID: wpr-209412

ABSTRACT

Investigation and analysis of accidents are critical elements of safety management. The over-riding purpose of an organization in carrying out an accident investigation is to prevent similar accidents, as well as seek a general improvement in the management of health and safety. Hundreds of workers have suffered injuries while installing, maintaining, or servicing machinery and equipment due to sudden re-energization of power lines. This study presents and analyzes two electrical accidents (1 fatal injury and 1 serious injury) that occurred because the power supply was reconnected inadvertently or by mistake.


Subject(s)
Electric Power Supplies , Greece , Safety Management
3.
Journal of Pharmaceutical Analysis ; (6): 159-163, 2007.
Article in Chinese | WPRIM | ID: wpr-621716

ABSTRACT

In this paper an expert system for remote fault diagnosis in the ship lift was developed by analysis of the fault tree and combination with VPN. The fault tree was constructed based on the operation condition of the ship lift. The diagnosis model was constructed by hierarchical classification of the fault tree structure, and the inference mechanism was given. Logical structure of the fault diagnosis in the ship lift was proposed. The implementation of the expert system for remote fault diagnosis in the ship lift was discussed, and the expert system developed was realized on the VPN virtual network. The system was applied to the Gaobaozhou ship lift project, and it ran successfully.

4.
Academic Journal of Xi&#39 ; an Jiaotong University;(4): 159-163, 2007.
Article in Chinese | WPRIM | ID: wpr-844854

ABSTRACT

In this paper an expert system for remote fault diagnosis in the ship lift was developed by analysis of the fault tree and combination with VPN. The fault tree was constructed based on the operation condition of the ship lift. The diagnosis model was constructed by hierarchical classification of the fault tree structure, and the inference mechanism was given. Logical structure of the fault diagnosis in the ship lift was proposed. The implementation of the expert system for remote fault diagnosis in the ship lift was discussed, and the expert system developed was realized on the VPN virtual network. The system was applied to the Gaobaozhou ship lift project, and it ran successfully.

SELECTION OF CITATIONS
SEARCH DETAIL