Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 98
Filter
1.
China Medical Equipment ; (12): 2-8, 2024.
Article in Chinese | WPRIM | ID: wpr-1026435

ABSTRACT

At present,precise radiotherapy has been widely used through the development with many years,but the existing technique still is limited by the limitation of tolerance dose of normal tissues,which cannot achieve the optimal goal of treating tumor.Flash radiotherapy(Flash-RT)is one kind of radiotherapy technique that uses the beam with ultra-high dose rate(UHDR)to conduct irradiation,which can furthest treat tumors while significantly reduce radiation injury of normal tissues.But until now,the biological mechanism,key physical parameters and triggering mechanism of Flash-RT are still unclear,and its principle and clinical translational application are still in the stage of research.This review clarified the technological advance and clinical translational application of Flash-RT research through summarized the relevant research of Flash-RT.

2.
China Medical Equipment ; (12): 9-14,20, 2024.
Article in Chinese | WPRIM | ID: wpr-1026436

ABSTRACT

The Flash radiotherapy(Flash-RT),which is the key breakthrough in the basic field of radiotherapy technique,which is expected to cause a new major transformation in the field of radiotherapy.In this paper,we reviewed the latest research advances of the application and the mechanism exploration of Flash-RT in tumor treatment.Current studies have found that both the Flash-RT with electron beams and photon and the Flash-RT with proton can reduce injury of normal tissue than radiotherapy with conventional dose-rate,but the relevant mechanisms are not yet clearly understood,which includes but not limited to oxygen depletion,DNA damage,cellular senescence,apoptosis and immune response.The difference of Flash-RT injury between tumor tissue and normal tissue further reduces the limitations of radiotherapy,and reduces the adverse reaction and complication compared with conventional radiotherapy,which has wide application prospects.

3.
China Medical Equipment ; (12): 15-20, 2024.
Article in Chinese | WPRIM | ID: wpr-1026437

ABSTRACT

Radiotherapy is an important means to treat lung cancer,but it is easy to cause lung injury and reduce the quality of life of patients.Flash radiotherapy(FLASH-RT)has attracted attention due to its extremely short radiation duration and high dose rate,which can reduce toxicity of normal tissue while ensures treatment intensity of tumor.Whether Flash-RT can reduce radiation-induced lung injury has become an important research topic in recent years.Based on the literature analysis method,this review systematically assessed the effects and mechanisms of Flash-RT and radiotherapy with conventional dose rate on lung injury through searching relevant literatures at home and abroad,so as to provide scientific basis for the treatment of patients with lung cancer by reviewing the comparisons about the effects and mechanisms between Flash-RT and radiotherapy with conventional dose rate on lung injury.Compared with radiotherapy with conventional radiation rate,Flash-RT can significantly reduce lung injury and improve quality of life of patients.It is still demanded to explore the Flash-RT mechanism in future,so as to develop the Flash-RT instrument that is suitable for different tumors and to conduct larger-scale clinical researches.

4.
China Medical Equipment ; (12): 21-23,28, 2024.
Article in Chinese | WPRIM | ID: wpr-1026438

ABSTRACT

Objective:To study and design one kind of flash radiotherapy(Flash-RT)equipment with ultra-high dose rate,which can be used in the mechanism research of Flash-RT with ultra-high dose rate.Methods:Based on the technique roadmap of high-power petal accelerator,the Flash-RT equipment can realize the requirement of Flash-RT for ultra-high dose rate and multiple irradiation angles.The corresponding design and research work were carried out on the basis of the overall design of the equipment,the main components and characteristics,the dynamics design of beam,the construction of movable and preliminary experimental platform,etc.Result:The dose rate of the designed equipment can reach to 100 Gy/s at a distance of 0.8 meters from the target point,which is easy to realize the radiotherapy method with multi angles.Conclusion:The designed X-ray equipment based on the technique roadmap of high-power petal accelerator can realize the research for the mechanism of medical Flash-RT equipment with ultra-high dose rate.

5.
China Medical Equipment ; (12): 24-28, 2024.
Article in Chinese | WPRIM | ID: wpr-1026439

ABSTRACT

The protection effect of flash-radiotherapy(Flash-RT)with super-high dose on normal tissue has obtained wide attention in therapeutic radiology since it was found in 2014 year.The increasing research demand of Flash-RT with super-high dose-rate proposed new challenge for the existing radiotherapy equipment.Based on the demands of FLASH-RT research and clinical application,this review analyzed the proposed new requirement of Flash-RT for equipment,and introduce current scientific facilities with the experimental ability of X-ray FLASH-RT,as well as the situation of the specialized FLASH-RT equipment which were developing.The research of Flash-RT mechanism need the existing equipment with high-energy X-ray source develop toward high power,while the clinical application of Flash-RT demand these transient high-power devices should possess a series of radiotherapy techniques such as multi angle irradiation,conformal radiotherapy and others.Currently,China's X-ray FLASH-RT research is at the forefront of the world,which is expected to achieve the first breakthrough of high-end medical equipment in the X-ray Flash RT field.

6.
Arch. endocrinol. metab. (Online) ; 67(3): 289-297, June 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1429747

ABSTRACT

ABSTRACT Objectives: To evaluate the alternate use of flash glucose monitoring (FGM) with self-monitoring blood glucose (SMBG), in patients with type 1 diabetes (T1D). Materials and methods: Two weeks of open FGM (P2), both preceded (P1) and followed by 2 weeks (P3) of SMBG with a blinded FGM system. Mean absolute relative difference (MARD) was calculated by (-FGMi − SMBGi-) / SMBGi, where it was a paired data sample. Results: In total, 34 patients were evaluated. Time in range (TIR) did not change between P1 and P2. In 12 patients (35.3%), TIR increased from 40% at P1 to 52% at P2 (p = 0.002) and in 22 (64.7%), TIR decreased or did not change. FGM use resulted in decreased % time spent in hypoglycemia (<70 mg/dL) (6.5% vs. 5.0%; p = 0.005), increased % time spent in hyperglycemia (>180 mg/dL) (44.5% to 51%; p = 0.046) with no significant change in % TIR. The proportion of patients who reached sensor-estimated glycated hemoglobin (eA1c) < 7% decreased from 23.5% at P1 to 12.9% at P2, p = 0.028. For the whole sample, the MARD between the two methods was 15.5% (95% CI 14.5-16.6%). For normal glucose range, hyperglycemic levels and hypoglycemic levels MARD were 16.0% (95% CI 15.0-17.0%), 13.3% (95% CI 11.5-15.2%) and 23.4% [95% CI 20.5-26.3%)], respectively. Conclusion: FGM after usual SMBG decreased the % time spent in hypoglycemia concomitant with an undesired increase in % time spent in hyperglycemia. Lower accuracy of FGM regarding hypoglycemia levels could result in overcorrection of hypoglycemia.

7.
Article in English | WPRIM | ID: wpr-971210

ABSTRACT

BACKGROUND@#Alcohol consumption is a prevalent behavior that is bi-directionally related to the risk of type 2 diabetes. However, the effect of daily alcohol consumption on glucose levels in real-world situations in the general population has not been well elucidated. This study aimed to clarify the relationship between alcohol consumption and all-day and time-specific glucose levels among non-diabetic individuals.@*METHODS@#We investigated 913 non-diabetic males and females, aged 40-69 years, during 2018-2020 from four communities across Japan. The daily alcohol consumption was assessed using a self-report questionnaire. All-day and time-specific average glucose levels were estimated from the interstitial glucose concentrations measured using the Flash glucose monitoring system for a median duration of 13 days. Furthermore, we investigated the association between all-day and time-specific average glucose levels and habitual daily alcohol consumption levels, using never drinkers as the reference, and performed multiple linear regression analyses after adjusting for age, community, and other diabetes risk factors for males and females separately.@*RESULTS@#All-day average glucose levels did not vary according to alcohol consumption categories in both males and females. However, for males, the average glucose levels between 5:00 and 11:00 h and between 11:00 and 17:00 h were higher in moderate and heavy drinkers than in never drinkers, with the difference values of 4.6 and 4.7 mg/dL for moderate drinkers, and 5.7 and 6.8 mg/dL for heavy drinkers. Conversely, the average glucose levels between 17:00 and 24:00 h were lower in male moderate and heavy drinkers and female current drinkers than in never drinkers; the difference values of mean glucose levels were -5.8 for moderate drinkers, and -6.1 mg/dL for heavy drinkers in males and -2.7 mg/dL for female current drinkers.@*CONCLUSIONS@#Alcohol consumption was associated with glucose levels in a time-dependent biphasic pattern.


Subject(s)
Humans , Male , Female , Diabetes Mellitus, Type 2 , Blood Glucose Self-Monitoring , Blood Glucose , Alcohol Drinking/epidemiology , Risk Factors , Alcoholic Intoxication
8.
Article in Chinese | WPRIM | ID: wpr-992077

ABSTRACT

Objective:To investigate the effects of 40 Hz and 70 Hz frequency flash stimulation on the ability of learning memory and autonomous exploratory in young rats.Methods:Twenty-seven SPF grade male SD rats aged 19-21 days were divided into control group (Ctr group), 40 Hz group and 70 Hz group with 9 in each group according to the random number table.The rats in Ctr group were not given flash stimulation, while rats in the 40 Hz and 70 Hz group were received 40 Hz, 70 Hz flash stimulation (1.5 h/d for 39 days), respectively.The Morris water maze experiment was used to assess the learning and memory ability of rats, and the open field experiment was used to evaluate the ability of autonomous exploratory of rats.Nissl staining was used to assess the morphology of Nissl bodies in the hippocampus CA1 region of the rats.The local field potentials (LFPs) collected from the primary visual cortex (V1 area) region by electrophysiological experiments was used to verify the synchronization of flash evoked neural oscillations.SPSS 23.0 software was used for statistical analysis.The repeated measures ANOVA and one-way ANOVA were used to analyze normal distribution measurement data, and LSD and Tamhane tests were used for further pairwise comparison.The Kruskal-Wallis test was used for non-normal distribution measurement data.Results:(1) The flash stimulation of 40 Hz and 70 Hz both can effectively caused synchronization of neural oscillations in the primary visual cortex of healthy young rats.(2) The results of repeated measures ANOVA analysis showed that there was no interaction effect of grouping and time in the escape latency of young rats in the Morris water maze positioning navigation phase( F=1.326, P>0.05 ). The escape latency had time main effect ( F=40.025, P<0.05), but no grouping main effect ( F=2.039, P>0.05). With the increase of learning days, the escape latency of young rats in each group decreased significantly.There was no interaction effect of grouping and time in the total distance of young rats ( F=2.029, P>0.079). It had time main effect ( F=32.052, P<0.05), but not grouping main effect ( F=2.390, P>0.05) on total distance.With the increase of learning days, the total distance of young rats in each group significantly shortened.On the 6th day of the Morris water maze experiment, there was no statistically significant difference among groups in terms of time in the target quadrant and the number of crossing platforms ( F=2.511, 0.802, both P>0.05). The results of the open field experiment showed that the total distance traveled in the center of young rats in each group was statistically significant ( H=8.935, P<0.05), the total distance traveled in the center in the 70 Hz group (3.80 (2.25, 6.93) m)was significantly longer than that in the 40 Hz group (0.80 (0.72, 1.46) m), P<0.05). The percentage of time spent in the center was statistically significant in the three groups ( H=11.050, P<0.05). Young rats in the 70 Hz group spent significantly higher percentage of time in the center(3.20(2.43, 8.30)) than those in the 40 Hz group (0.95 (0.37, 1.06 ), P<0.05 ). (3) Nissl staining results showed that Nissl bodies in the hippocampal CA1 area of young rats in Ctr, 40 Hz and 70 Hz group were all arranged neatly and tightly, no edema was found in the surrounding stroma, and no obvious inflammatory cell infiltration was found. Conclusion:70 Hz frequency flash stimulation may promote the ability of learning memory and autonomous exploratory of young rats.

9.
Journal of Chinese Physician ; (12): 335-341, 2023.
Article in Chinese | WPRIM | ID: wpr-992304

ABSTRACT

Objective:To assess the effect of flash glucose monitoring (FGM) compared with self-monitoring of blood glucose (SMBG) on glycemic control, residual islet function, and patient-reported outcomes in children and adolescents with newly diagnosed type 1 diabetes within 1 year.Methods:133 children and adolescents with newly diagnosed T1DM in the T1D clinic of the Second Xiangya Hospital of Central South University from January 2016 to January 2020 were divided into two groups: FGM group ( n=82) and SMBG group ( n=51). The observation indexes included hemoglobin A1c (HbA 1c), fasting and postprandial blood glucose (FBG and 2 h BG), C-peptide (FCP and 2 h CP) during the one-year follow-up, Δ CP (2 h CP-FCP), patient-reported hypoglycemia and questionnaires regarding self-management of diabetes and quality of life. Results:At 6 months, HbA 1c in 2 groups was significantly decreased (all P<0.05); at 6 to 12 months, HbA 1c in FGM group tended to be stable ( P>0.05); at 12 months, HbA 1c in SMBG group was significantly increased compared with 6 months ( P=0.001). At 12 months, HbA 1c in SMBG group was higher than that in FGM group ( P=0.001). At 12 months, FBG in FGM group was equivalent to the baseline level ( P>0.05), while FBG in SMBG group was significantly higher than the baseline level ( P=0.006). 2 h BG only decreased at the 6th and 12th month in FGM group (all P<0.05). The FCP of SMBG group was significantly decreased at 12 months ( P<0.05), and the 2 h CP, Δ CP in the two groups decreased gradually (all P<0.05). FGM group had more hypoglycemic events at 6 and 12 months (all P<0.05). At 6 months, the score of Self-Management of T1D for Adolescents (SMOD-A) in FGM group was significantly improved ( P=0.001). During the follow-up period, the quality of life score of FGM group was stable ( P>0.05), while the quality of life score of SMBG group had a downward trend ( P=0.052). Conclusions:In newly diagnosed children and adolescents with T1DM, early application of FGM for blood glucose management will help to improve HbA 1c and reduce postprandial blood glucose. In addition, the self-management ability of children with FGM was improved after 6 months.

10.
Article in Chinese | WPRIM | ID: wpr-993065

ABSTRACT

The ultra-high dose rate (UHDR) radiation has less side effect while keep comparable tumor control effect with conventional dose rate (CONV) radiation, which was named Flash effect. Recently, the Flash effect has been reported in many animal experiments with various types of radiations, animal species and body parts. However, the underlying mechanism of Flash has still been unraveled, making difficulties for the clinical application. This review pointed out the differences between the Flash effect and the UHDR effect in vitro and proposed three key scientific questions of Flash effect based on three well-known hypotheses, i. e., oxygen depletion, peroxyl radical recombination and immune cell protection. Finally, the research progresses and challenges of Flash mechanism study are concluded in order to give a clue for further deep investigation.

11.
Article in Chinese | WPRIM | ID: wpr-994315

ABSTRACT

Objective:This study aimed to investigate the effect of lipohypertrophy induced by insulin injection on blood glucose fluctuation in patients with type 1 diabetes mellitus.Methods:A total of 80 patients with type 1 diabetes mellitus were recruited between June 2021 and December 2021 from the First Affiliated Hospital of Nanjing Medical University. And these patients all received insulin injection more than six months. Lipohypertrophy was assessed by ultrasound scanning, and blood glucose fluctuation was evaluated using the flash glucose monitoring system(FGM). Univariate analysis and multivariate linear regression were used to analyze the relationship of lipohypertrophy and and core indicators of blood glucose fluctuation.Results:Compared with patients without lipohypertrophy, patients with lipohypertrophy had higher mean amplitude of glycemic excursions(MAGE), coefficient of variation(CV), mean of daily differences(MODD), standard deviation(SD) of blood glucose, time above range(TAR), and high blood glucose index(HBGI; all P<0.05), while time in range(TIR) of glucose markedly become lower( P<0.01). Moreover, multivariate linear regression analysis showed that lipohypertrophy detected by ultrasound was an independent influencing factor of TIR( β=-9.423, P=0.032), MAGE( β=1.114, P=0.039), CV( β=4.304, P=0.041), MODD( β=0.717, P=0.046) after adjusting for age at diagnosis, duration of insulin injection, fasting C-peptide, and daily dose of insulin per unit weight. Conclusion:Lipohypertrophy increases glycemic variability and imposes negative impact on glycemic control rate in patients type 1 diabetes mellitus.

12.
Article in Chinese | WPRIM | ID: wpr-1025025

ABSTRACT

Objective To explore the animal model of syndrome used in the study of hot flash phenomenon in women.Methods Twenty-four female SD rats were divided randomly into three groups:Con group,Ovx group,and tamoxifen group(n = 8 rats per group).Hot flashes were induced by bilateral oophorectomy and intragastric tamoxifen 10 mg/(kg·d),respectively.Open-field activity,anal temperature,and body surface infrared thermograms were detected on model days 14 and 28.The rats were then killed on day 29 and their uteruses were removed,weighed,and sectioned.Blood estradiol and catecholamine levels were determined by enzyme-linked immunosorbent assay.Gene expression levels of adrenal sex hormone synthetases(Star,Cyp11a1,Cyp17a1,Cyp19a1,Por,Hsd3b2,Hsd17b1)and catecholamine synthetases(Th,Ddc,Dbh,Pnmt)in the adrenal medulla were detected by reverse transcription-polymerase chain reaction.Results Rat body weight was significantly higher in the Ovx group compared with Con group(P<0.01),while body weight increased slowly in the tamoxifen group.The maximum body surface temperature was significantly decreased on day 28 in the Ovx group(P<0.01),the difference between the maximum and minimum abdominal temperatures was significantly increased on day 14(P<0.05),the difference between the maximum and minimum temperatures on the back was significantly increased on day 28(P<0.01),and the open-field activity was decreased(P<0.01).Compared with the sham operation group,the maximum body surface temperature in the tamoxifen group was significantly decreased(P<0.01)but the open-field activity was increased(P<0.01).The uterine index was significantly decreased in both models(P<0.01).Estradiol levels were significantly decreased(P<0.01)and NE and epinephrine were also significantly decreased in the Ovx group compared with Con group(P<0.05),and β-EP was also significantly decreased in Ovx group(P<0.05).Adrenal Cyp11a1 gene expression was significantly increased(P<0.05)while Cyp17a1 and Hsd17b1 gene expression levels were significantly decreased(P<0.05)in bilateral ovariectomized rats compared with Con group.Compared with Con group,gene expression levels of Star and Por were significantly increased(P<0.01)while Cyp17a1 gene expression was significantly decreased(P<0.01)in the tamoxifen group,and Pnmt gene expression was significantly down-regulated in Ovx group(P<0.01).Conclusions Bilateral ovariectomized rats can be used for the study of perimenopausal hot flashes,which resemble kidney Yang and Yin deficiency in traditional Chinese medicine.

13.
Article in Chinese | WPRIM | ID: wpr-1027332

ABSTRACT

Objective:To explore the feasibility of synthetic diamond detector in use for Flash radiation dosimetry by designing a diamond dosimeter and conducting a series of dosimetric characteristic tests.Methods:A diamond detector system prototype with real-time current output was developed using a CIVIDEC? B1HV diamond sensor and designing a large dynamic range current measurement circuit based on the pre-integration method. The dose (dose-rate) response linearity was tested under irradiation from both electron beam and X ray ultra-high dose rate. Dose (dose-rate) calibration was performed against a medical accelerator to gain the charge-dose transfer coefficient.Results:Good linear correlation ( R2 = 0.99) between detector output charge and reference dose per pulse was shown under electron beam irradiation of 0.08-0.50 Gy/pulse. Good linearity ( R2 = 0.99) is also shown under irradiation from electron beam with ultra-high dose rate (400 Gy/s) and conventional dose rate (0.5 Gy/s). Strictly linear correlation ( R2 = 1) was shown between detector output integrated charge and reference dose under X ray irradiation at ultra-high average dose rate (75.5 Gy/s) and conventional average dose rate (0.5 Gy/s). The charge-dose and current-dose rate conversion factors for practical use were 0.751 7 μC/Gy and 0.753 5 μA·Gy·s -1, respectively. Conclusions:Considerable linearity of the diamond detector dose responses were shown under irradiation both from electron beam and X-ray beam, which could provide a relatively rapid and accurate dosimetry for Flash preclinical experiments. Furthermore, diamond detectors have great potential in the quality assurance for Flash radiotherapy.

14.
Rev. chil. endocrinol. diabetes ; 16(3): 80-86, 2023. ilus, tab
Article in Spanish | LILACS | ID: biblio-1451971

ABSTRACT

OBJETIVO: Evaluar el tiempo en rango de glucosa y su asociación con otras medidas del control glicémico establecidas por el consenso internacional del tiempo en rango en usuarios de vida real del sistema flash de monitorización de glucosa FreeStyle LibreTM en Chile. MÉTODOS: Se analizaron los datos provenientes de la base de datos Freestyle Libre™ entre diciembre de 2014 y enero de 2022. Las lecturas se dividieron en 10 grupos (deciles) del mismo tamaño (cada decil contenía aproximadamente 498 usuarios) en función del tiempo en rango. Para cada decil se calculó la media de determinaciones diarias, el promedio de glucosa, la HbA1c, la desviación estándar de glucosa, el coeficiente de variación de la glucosa, el tiempo en rango, el tiempo de glucosa (porcentaje) por encima de 250 mg/dL (TA250), el tiempo de glucosa (porcentaje) por encima de 180 mg/dL (TA180), el tiempo por debajo (porcentaje) de 70 mg/dL (TB70) y el tiempo por debajo (porcentaje) de 54 mg/dL (TB54). RESULTADOS: Desde diciembre de 2014 hasta enero de 2022 hubo 4984 lectores. El grupo con el mayor tiempo en rango mostró significativamente una menor glucosa promedio que el grupo con el tiempo en rango más bajo (decil 1: media 248,3 mg/dL, decil 10: media 113,2 mg/L, diferencia ­135,1 mg/dL, p<0.05). Asimismo, el mayor tiempo en rango se asoció con una menor desviación estándar (decil 1: media 93,7mg/dL, decil 10: media 26,7mg/L, diferencia: -67,0 mg/ dL, p<0,05), menor coeficiente de variación (decil 1: media 37,8%, decil 10: media 23,3%, diferencia: -14,5%, p<0,05), menor TA250 (decil 1: media 46,5%, decil 10: media 0,2%, diferencia: -46,3%, p<0.05), menor TA180 (decil 1: media 73,9%, decil 10: media 3,8%, diferencia: -70,1%, p<0.05), menor TB70 (decil 5: mediana 6,13%, decil 10: mediana 1,70%, diferencia: -4,43%, p<0.05) y menor TB54 (decil 5: mediana 1,79%, decil 10: mediana 0,12%, diferencia: -1,67%, p<0.05). El mayor tiempo en rango se asoció también significativamente con más determinaciones diarias (decil 1: media 11,4, decil 10: media 16,6, diferencia: 5,2, p<0,05). La frecuencia media de las determinaciones entre todos los lectores fue de 14,7 determinaciones diarias. CONCLUSIONES: En los pacientes con diabetes en Chile, el empleo del sistema flash de monitorización demuestra la asociación entre el mayor tiempo en rango, la reducción de la variabilidad de la glucosa y un menor riesgo de hiperglucemias e hipoglicemias y también con un mayor compromiso.


OBJECTIVE: To evaluate glucose time in range and its association with other metrics of glucose control established by the International Consensus on TIR amongst real-life patients using the Flash Glucose Monitoring system FreeStyle LibreTM in Chile. METHODS: Data from the Freestyle Libre™ database between December 2014 and January 2022 were analyzed. Readers were divided into 10 groups (deciles) of the same size (each decile had approximately 498 users) according to time in range. For each decile of time in range, the mean of daily scans, average glucose, estimated HbA1c, glucose standard deviation, glucose coefficient of variation, time in range, glucose time (percentage) above 250 mg/dL (TA250), and glucose time (percentage) above 180 mg/dL (TA180), and the median of glucose time (percentage) below 70 mg/dL (TB70) and glucose time (percentage) below 54 mg/dL (TB54), were calculated. RESULTS: From December 2014 to January 2022, there were 4984 readers. The group with the highest TIR showed significantly lower average glucose than the group with the lowest TIR (decile 1: mean 248.3 mg/dL, decile 10: mean 113.2 mg/L, difference: ­135.1 mg/dL, p<0.05). In addition, more time in range was associated with a lower glucose standard deviation (decile 1: mean 93.7 mg/dL, decile 10: mean 26.7 mg/L, difference: -67.0 mg/dL, p<0.05), lower glucose coefficient of variation (decile 1: mean 37.8%, decile 10: mean 23.3%, difference: -14.5%, p<0.05), lower TA250 (decile 1: mean 46.5%, decile 10: mean 0.2%, difference: -46.3%, p<0.05),lower TA180 (decile 1: mean 73.9%, decile 10: mean 3.8%, difference: -70.1%, p<0.05), lower TB70 (decile 5: median 6.13%, decile 10: median 1.70%, difference: -4.43%, p<0.05) and lower TB54 (decile 5: median 1.79%, decile 10: median 0.12%, difference: -1.67%, p<0.05). Greater TIR was also associated with significantly more daily scans (decile 1: mean 11.4, decile 10: mean 16.6, difference: 5.2, p<0.05). Mean scan frequency amongst all readers was 14.7 daily scans. CONCLUSIONS: In patients with diabetes from Chile, the use of the flash glucose monitoring system demonstrates the association between greater TIR, reduced glucose variability, and reduced risk of hyperglycemia and hypoglycemia, and also its association with greater engagement.


Subject(s)
Humans , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus , Glycemic Control/methods , Time Factors , Blood Glucose , Chile , Patient Compliance , Extracellular Fluid , Data Accuracy
15.
Indian J Ophthalmol ; 2022 Jan; 70(1): 201-209
Article | IMSEAR | ID: sea-224085

ABSTRACT

Purpose: There are no effective treatments currently available for optic nerve transection injuries. Stem cell therapy represents a feasible future treatment option. This study investigated the therapeutic potential of human umbilical cord–derived mesenchymal stem cell (hUC?MSC) transplantation in rats with optic nerve injury. Methods: Sprague–Dawley (SD) rats were divided into three groups: a no?treatment control group (n = 6), balanced salt solution (BSS) treatment group (n = 6), and hUC?MSCs treatment group (n = 6). Visual functions were assessed by flash visual evoked potential (fVEP) at baseline, Week 3, and Week 6 after optic nerve crush injury. Right eyes were enucleated after 6 weeks for histology. Results: The fVEP showed shortened latency delay and increased amplitude in the hUC?MSCs treated group compared with control and BSS groups. Higher cellular density was detected in the hUC?MSC treated group compared with the BSS and control groups. Co?localized expression of STEM 121 and anti?S100B antibody was observed in areas of higher nuclear density, both in the central and peripheral regions. Conclusion: Peribulbar transplantation of hUC?MSCs demonstrated cellular integration that can potentially preserve the optic nerve function with a significant shorter latency delay in fVEP and higher nuclear density on histology, and immunohistochemical studies observed cell migration particularly to the peripheral regions of the optic nerve.

16.
Article in English | WPRIM | ID: wpr-928990

ABSTRACT

OBJECTIVES@#Patients with classical type 1 diabetes mellitus (T1DM) require lifelong dependence on exogenous insulin therapy due to pancreatic beta-cell destruction and absolute insulin deficiency. T1DM accounts for about 90% of children with diabetes in China, with a rapid increase in incidence and a younger-age trend. Epidemiological studies have shown that the overall glycated haemoglobin (HbA1c) and compliance rate are low in Chinese children with T1DM. Optimal glucose control is the key for diabetes treatment, and maintaining blood glucose within the target range can prevent or delay chronic vascular complications in patients with T1DM. Therefore, this study aims to investigate the glycemic control of children with T1DM from Hunan and Henan Province with flash glucose monitoring system (FGMS), and to explore factors associated with glycemic variability.@*METHODS@#A total of 215 children with T1DM under 14 years old were enrolled continuously in 16 hospitals from August 2017 to August 2020. All subjects wore a FGMS device to collect glucose data. Correlation of HbA1c, duration of diabetes, or glucose scan rates with glycemic variability was analyzed. Glucose variability was compared according to the duration of diabetes, HbA1c, glucose scan rates and insulin schema.@*RESULTS@#HbA1c and duration of diabetes were positively correlated with mean blood glucose, standard deviation of glucose, mean amplitude of glucose excursions (MAGE), and coefficient of variation (CV) of glucose (all P<0.01). The glucose scan rates during FGMS wearing was significantly positively correlated with time in range (TIR) (P=0.001) and negatively correlated with MAGE and mean duration of hypoglycemia (all P<0.01). Children with duration ≤1 year had lower time below range (TBR) and MAGE when compared with those with duration >1 year (all P<0.05). TIR and TBR in patients with HbA1c ≤7.5% were higher (TIR: 65% vs 45%, TBR: 5% vs 4%, P<0.05), MAGE was lower (7.0 mmol/L vs 9.4 mmol/L, P<0.001) than those in HbA1c >7.5% group. Compared to the multiple daily insulin injections group, TIR was higher (60% vs 52%, P=0.006), MAGE was lower (P=0.006) in the continuous subcutaneous insulin infusion group. HbA1c was lower in the high scan rates (≥14 times/d) group (7.4% vs 8.0%, P=0.046), TIR was significantly higher (58% vs 47%, P<0.001), and MAGE was lower (P<0.001) than those in the low scan rate (<14 times/d) group.@*CONCLUSIONS@#The overall glycemic control of T1DM patients under 14 years old in Hunan and Henan Province is under a high risk of hypoglycemia and great glycemic variability. Shorter duration of diabetes, targeted HbA1c, higher glucose scan rates, and CSII are associated with less glycemic variability.


Subject(s)
Adolescent , Child , Humans , Blood Glucose , Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1/drug therapy , Glucose , Glycated Hemoglobin/analysis , Hypoglycemia/prevention & control , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use
17.
Neuroscience Bulletin ; (6): 166-180, 2022.
Article in English | WPRIM | ID: wpr-929081

ABSTRACT

Neuroscientists have emphasized visceral influences on consciousness and attention, but the potential neurophysiological pathways remain under exploration. Here, we found two neurophysiological pathways of heart-brain interaction based on the relationship between oxygen-transport by red blood cells (RBCs) and consciousness/attention. To this end, we collected a dataset based on the routine physical examination, the breaking continuous flash suppression (b-CFS) paradigm, and an attention network test (ANT) in 140 immigrants under the hypoxic Tibetan environment. We combined electroencephalography and multilevel mediation analysis to investigate the relationship between RBC properties and consciousness/attention. The results showed that RBC function, via two independent neurophysiological pathways, not only triggered interoceptive re-representations in the insula and awareness connected to orienting attention but also induced an immune response corresponding to consciousness and executive control. Importantly, consciousness played a fundamental role in executive function which might be associated with the level of perceived stress. These results indicated the important role of oxygen-transport in heart-brain interactions, in which the related stress response affected consciousness and executive control. The findings provide new insights into the neurophysiological schema of heart-brain interactions.


Subject(s)
Humans , Awareness , Brain , Consciousness , Oxygen , Visual Perception
18.
Article in Chinese | WPRIM | ID: wpr-936350

ABSTRACT

OBJECTIVE@#To investigate the therapeutic effect of Epothilone D on traumatic optic neuropathy (TON) in rats.@*METHODS@#Forty-two SD rats were randomized to receive intraperitoneal injection of 1.0 mg/kg Epothilone D or DMSO (control) every 3 days until day 28, and rat models of TON were established on the second day after the first administration. On days 3, 7, and 28, examination of flash visual evoked potentials (FVEP), immunofluorescence staining and Western blotting were performed to examine the visual pathway features, number of retinal ganglion cells (RGCs), GAP43 expression level in damaged axons, and changes of Tau and pTau-396/404 in the retina and optic nerve.@*RESULTS@#In Epothilone D treatment group, RGC loss rate was significantly decreased by 19.12% (P=0.032) on day 3 and by 22.67% (P=0.042) on day 28 as compared with the rats in the control group, but FVEP examination failed to show physiological improvement in the visual pathway on day 28 in terms of the relative latency of N2 wave (P=0.236) and relative amplitude attenuation of P2-N2 wave (P=0.441). The total Tau content in the retina of the treatment group was significantly increased compared with that in the control group on day 3 (P < 0.001), showing a consistent change with ptau-396/404 level. In the optic nerve axons, the total Tau level in the treatment group was significantly lower than that in the control group on day 7 (P=0.002), but the changes of the total Tau and pTau-396/404 level did not show an obvious correlation. Epothilone D induced persistent expression of GAP43 in the damaged axons, detectable even on day 28 of the experiment.@*CONCLUSION@#Epothilone D treatment can protect against TON in rats by promoting the survival of injured RGCs, enhancing Tau content in the surviving RGCs, reducing Tau accumulation in injured axons, and stimulating sustained regeneration of axons.


Subject(s)
Animals , Rats , Disease Models, Animal , Epothilones , Evoked Potentials, Visual , Nerve Regeneration/physiology , Optic Nerve Injuries/metabolism , Rats, Sprague-Dawley , Retinal Ganglion Cells/physiology
19.
Chinese Journal of Digestion ; (12): 158-162, 2022.
Article in Chinese | WPRIM | ID: wpr-934140

ABSTRACT

Objective:To evaluate the effects of the cassette 14C-urea breath test kit, scintillation sampling bottle (solid-state scintillation method) and liquid scintillation 14C-urea breath test kit in the diagnosis of Helicobacter pylori ( H. pylori) infection. Methods:From January 7 to October 28, 2020, 239 patients were enrolled who visited Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine, the Second Affiliated Hospital of Zhejiang University School of Medicine and the First Affiliated Hospital of Nanchang University. All subjects first received 14C-urea breath test.Within >1 to <7 days after gas collection, mucosal tissues were taken under gastroscopy for gold standard test, including biopsy and rapid urease test (RUT). If both biopsy and RUT indicated H. pylori positive, the result of gold standard test was H. pylori positive, and if both were negative, the result of gold standard test was H. pylori negative. If the results of biopsy and RUT were inconsistent, they were not included in the subsequent analysis. Based on the results of gold standard test, the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of the cassette 14C-urea breath test kit, scintillation sampling bottle, and liquid scintillation 14C-urea breath test kit in the diagnosis of H. pylori infection were analyzed. The safety of the test was evaluated by whether there were any adverse events during the test. Descriptive methods were used for statistical analysis. Results:Among the 239 subjects, 12 cases did not complete the test, 227 subjects finally completed the test. The test completion rate was 95.0% (227/239). No.008 patient was only included in the analysis of cassette 14C-urea breath test kit and scintillation sampling bottle because of lacking the result of liquid scintillation breath test. The results of gold standard test showed that among 227 patients, 87 cases were H. pylori positive, 118 cases were H. pylori negative. The results of biopsy and RUT were inconsistent in 22 cases, so they were not included in the subsequent analysis. Excluding No.008 patient, the results of gold standard test showed that 86 cases were H. pylori positive and 118 cases were negative. Based on the results of gold standard test, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of cassette 14C-urea breath test kit, scintillation sampling bottle, and the liquid scintillation 14C-urea breath test kit in the diagnosis of H. pylori infection were 91.9%, 100.0%, 96.6%, 100.0% and 94.4%, respectively; 95.4%, 97.5%, 96.6%, 96.5% and 96.6%, respectively; and 96.5%, 99.2%, 98.0%, 98.8% and 97.5%, respectively. Only one adverse event (right upper abdominal pain after eating) occurred. Combined with the patients condition, the adverse event was determined as the onset of chronic cholecystitis and it might not be related to the test medication. Conclusions:Cassette 14C-urea breath test kit, scintillation sampling bottle, and liquid scintillation 14C-urea breath test kit have reliable performance, good safety, and high sensitivity, specificity and accuracy in the diagnosis of H. pylori infection, which are worthy of clinical application.

20.
Ciênc. rural (Online) ; 52(2): e20210068, 2022. tab, graf, ilus
Article in English | VETINDEX, LILACS | ID: biblio-1286060

ABSTRACT

This research valorized Pachira aquatica Aubl.'s fruit shells (PAS) through its energetic characterization and flash pyrolysis for biofuels or chemicals production. The characterization was performed through proximate and ultimate analysis, bulk density, higher heating value (HHV), hemicellulose, cellulose and lignin content, thermogravimetric analysis and absorption spectra in the infrared region obtained by Fourier-transform infrared spectroscopy technique (FTIR). The analytical flash pyrolysis was performed at 500°C in a Py-5200 HP-R coupled to a gas chromatograph (Py-GC/MS). The PAS biomass presents potential for thermochemical energy conversion processes due to its low moisture and ash content, 76.90% of volatile matter, bulk density of 252.6 kg/m3 and HHV of 16.24 MJ/kg. Flash pyrolysis products are mostly phenols or light organic acids derived from the decomposition of polysaccharides. Results confirmed the potential of PAS to produce bio-phenolics, such as 4-methoxyphenol which is an important active ingredient for skin depigmentation used in drugs and cosmetics, and as phenolic extract that can be used as a precursor to resins, applications that convert this forest waste into bio products for industry into a green circular economy.


Este trabalho teve como objetivo a valorização das cascas dos frutos da Pachira aquatica Aubl. (PAC) através da sua caracterização energética e pirólise flash para produção de biocombustíveis ou produtos químicos. A caracterização foi realizada através de análises imediata e final, densidade aparente, poder calorífico superior (PCS), conteúdos de hemicelulose, celulose e lignina, análise termogravimétrica e espectros de absorção na região do infravermelho obtidos pela técnica de espectroscopia no infravermelho com transformada de Fourier (FTIR). A pirólise flash analítica foi realizada a 500 °C em equipamento Py-5200 HP-R acoplado a um cromatógrafo à gás (Py-GC/MS). A biomassa das PAC apresenta potencial para processos de conversão termoquímica de energia devido ao seu baixo teor de umidade e cinzas, além de 76,90% de materiais voláteis, densidade aparente de 252,6 kg/m3 e PCS igual a 16,24 MJ / kg. Os produtos da pirólise rápida são principalmente fenóis ou ácidos orgânicos leves derivados da decomposição de polissacarídeos. Os resultados confirmam o potencial das PAC para produzir bio-fenólicos, como o 4-metoxifenol que é um importante ingrediente ativo para despigmentação da pele usado em medicamentos e cosméticos, e como extrato fenólico que pode ser usado como precursor de resinas. Estas aplicações convertem esses resíduos florestais em produtos biológicos para a indústria em uma economia circular verde.


Subject(s)
Pyrolysis , Biomass , Bombacaceae , Fruit/chemistry , Lignin , Polysaccharides , Biofuels
SELECTION OF CITATIONS
SEARCH DETAIL