Chinese Journal of Analytical Chemistry ; (12): 1467-1474, 2017.
Article in Chinese | WPRIM | ID: wpr-658504

ABSTRACT

As a kind of fluorescent nanoprobe, BHHCT-Eu3+ @ SiO2 fluorescent nanoparticles were synthesized using microwave irradiation. Transmission electron microscopy characterization showed that the nanoparticles were in spherical shape with particle size of about 36 nm. The BHHCT-Eu3+@SiO2 exhibited good fluorescence property, with a maximal excitation wavelength of 343 nm and an maximal emission wavelength of 615 nm. The fluorescence lateral flow immunoassay ( LFIA ) was established for rapid and quantitative detection of kanamycin ( Kana) in milk after BHHCT-Eu3+@SiO2 fluorescent nanoparticles were conjugated with Kana antibody, with dextran as a linker. The limit of detection of Kana with the LFIA method was 0. 85 ng/mL with IC50 of 12. 76 ng/mL, and the detection range was from 3. 0 ng/m to 76 ng/mL. The recoveries of Kana in milk were between 93 . 7% and 97 . 4% with RSD of 3 . 1%-4 . 6%, and cross-reactivity of the fluorescence immunoassay strip for Kana determination was<1%. The detection results of kana in milk samples between the LFIA and traditional ELISA method showed good correlation.

2.
Chinese Journal of Analytical Chemistry ; (12): 1467-1474, 2017.
Article in Chinese | WPRIM | ID: wpr-661423

ABSTRACT

As a kind of fluorescent nanoprobe, BHHCT-Eu3+ @ SiO2 fluorescent nanoparticles were synthesized using microwave irradiation. Transmission electron microscopy characterization showed that the nanoparticles were in spherical shape with particle size of about 36 nm. The BHHCT-Eu3+@SiO2 exhibited good fluorescence property, with a maximal excitation wavelength of 343 nm and an maximal emission wavelength of 615 nm. The fluorescence lateral flow immunoassay ( LFIA ) was established for rapid and quantitative detection of kanamycin ( Kana) in milk after BHHCT-Eu3+@SiO2 fluorescent nanoparticles were conjugated with Kana antibody, with dextran as a linker. The limit of detection of Kana with the LFIA method was 0. 85 ng/mL with IC50 of 12. 76 ng/mL, and the detection range was from 3. 0 ng/m to 76 ng/mL. The recoveries of Kana in milk were between 93 . 7% and 97 . 4% with RSD of 3 . 1%-4 . 6%, and cross-reactivity of the fluorescence immunoassay strip for Kana determination was<1%. The detection results of kana in milk samples between the LFIA and traditional ELISA method showed good correlation.

3.
Journal of Modern Laboratory Medicine ; (4): 143-144,147, 2017.
Article in Chinese | WPRIM | ID: wpr-610894

ABSTRACT

Objective To evaluate the comparability of the test results of two immunoassay systems based on the electrochemical luminescence and the fluorescence lateral flow immunoassay for serum procalcitonin (PCT).Methods Roche cobas system was used as the reference system,and fluorescence lateral flow immunoassay system of Shanghai Upper biotech company was used as evaluated system.A total of 141 clinical samples during November,2015 were detected by the two systems to obtain the correlation coefficient and the Kappa values at the two cutoff values(0.5,2.0 ng/ml).Results The two systems showed high correlation (Y=1.008X-0.032,r=0.995,P<0.001) and low deviation (t=-0.230,P=0.819>0.05) without statistic significance between two methods.Kappa values were 0.944,0.943 respectively at the two cutoff values (0.5,2.0 ng/ml).Conclusion The test results showed no significant difference between the two immunoassay systems,suggesting a consistency between them for clinical detection of PCT.All the observed indicators reached the clinical diagnostic requirements and the method of quantitative detection of PCT by fluorescence lateral flow immunoassya can be applied for the quick detection of clinical human PCT.