Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 857
Filter
1.
Rev. argent. coloproctología ; 35(1): 40-44, mar. 2024. ilus
Article in Spanish | LILACS | ID: biblio-1551683

ABSTRACT

En este reporte presentamos tres pacientes en quienes ocurrieron condiciones inflamatorias perianales tardías, luego de la administración de sustancias modeladoras no identificadas en los glúteos. El diagnóstico inicial y supuesto no fue correcto, ya que no se investigó durante la evaluación preliminar el antecedente de la administración de elementos modeladores. Recomendamos que los pacientes con patologías inflamatorias del ano, sobre todo aquellos cuyo curso es extraño, se les pregunte acerca de la administración de agentes modeladores en los glúteos. Esta práctica puede contribuir a la eficacia del diagnóstico de manifestaciones perianales caracterizadas por flogosis, que se presentan de forma inusual. (AU)


In this report we present three patients in which late perianal inflammatory conditions occurred after administration of unidentified modeling agents to the buttocks. The initial diagnosis was not correct because of the administration of modeling agents was not investigated during the initial eval-uation. We recommend inquiring patients with inflammatory pathologies of the anus, especially those whose course is unusual, about the adminis-tration of modeling agents to the buttocks. This approach can contribute to the efficiency of the diagnosis of perianal complaints characterized by inflammation, but rare in its appearance. (AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Anus Diseases/surgery , Anus Diseases/etiology , Biopolymers/adverse effects , Buttocks/surgery , Anus Diseases/diagnosis , Cosmetic Techniques , Foreign-Body Migration , Prosthesis Implantation/adverse effects
2.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery ; (12): 80-82, 2024.
Article in Chinese | WPRIM | ID: wpr-1011107

ABSTRACT

Objective:To explore the feasibility of using self-made visual throat forceps to remove hypopharyngeal foreign bodies. Methods:The throat forceps were combined with the endoscope and connected to a monitor via a data cable resulting in a visual throat forceps apparatus. This device was utilized to examine and treat the hypopharyngeal foreign bodies. Results:Among 53 patients, foreign bodies were detected in 51,with 48 cases involving hypopharyngeal foreign bodies. All were successfully extracted using the visual throat forceps. Three cases, diagnosed as esophageal foreign bodies by electronic gastroscopy, were treated using the same method. Conclusion:Visual throat forceps can be used to examine the hypopharynx and remove foreign bodies. It has the advantages of simple operation, rapid operation, and high success rate of foreign body removal from the hypopharynx. It is worthy of clinical application.


Subject(s)
Humans , Hypopharynx/surgery , Pharynx/surgery , Endoscopes , Surgical Instruments , Foreign Bodies/diagnosis
3.
Vet. zootec ; 31: 42-49, 2024.
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1552980

ABSTRACT

A Retículo Peritonite Traumática está diretamente ligada à ingestão de objetos metálicos perfuro cortantes, como pregos e pedaços de arame, que podem penetrar ou perfurar a parede do retículo. Embora a ocorrência de corpos estranhos de alumínio seja rara, outros elementos, como fios de pneus usados para fixar lonas em silagens e até cerdas de arame de escovas utilizadas em pequenos aeroportos, têm sido registrados como causas dessa afecção. A ingestão desses objetos pode resultar em lesões no retículo, desencadeando episódios de retículo peritonite traumática e suas sequelas, como pericardite traumática, inflamação do fígado, abscessos no baço e muito mais. Os sinais clínicos podem variar, mas incluem comportamento anormal, motilidade reduzida do rúmen, fezes mal digeridas, febre e sinais de dor. O diagnóstico baseia-se na avaliação dos sinais clínicos do animal, juntamente com exames complementares, como hemograma, bioquímico, ultrassom e radiografia. É importante considerar as alterações hematológicas, como leucocitose e hiperfibrinogenemia, como indicadores-chave desta afecção. O diagnóstico também envolve testes de dor ao corpo estranho. O tratamento pode ser conservativo ou cirúrgico. A abordagem conservativa envolve a administração de antibióticos, anti-inflamatórios e soluções intravenosas, além do tratamento de deficiências nutricionais subjacentes. A opção cirúrgica exige a remoção do corpo estranho do retículo, seguida de cuidados pós-operatórios.


Traumatic Reticulum Peritonitis this directly linked to the ingestion of sharp metallic objects, such as nails and pieces of wire, which can penetrate or pierce the wall of the reticulum. Although the occurrence of aluminum foreign bodies is rare, other elements, such as tire wires used to attach tarpaulins to silage and even wire bristles from brushes used in small airports, have been recorded as causes of this condition. Ingestion of these objects can result in damage to the reticulum, triggering episodes of traumatic reticulum peritonitis and its sequelae, such as traumatic pericarditis, liver inflammation, spleen abscesses and more. Clinical signs may vary but include abnormal behavior, reduced rumen motility, poorly digested feces, fever and signs of pain. The diagnosis is based on the evaluation of the animal's clinical signs, together with complementary tests, such as blood count, biochemistry, ultrasound and radiography. It is important to consider hematological changes, such as leukocytosis and hyperfibrinogenemia, as key indicators of this condition. Diagnosis also involves foreign body pain testing. Treatment can be conservative or surgical. The conservative approach involves administering antibiotics, anti-inflammatories and intravenous solutions, in addition to treating underlying nutritional deficiencies. The surgical option requires removal of the foreign body from the reticulum, followed by post-operative care.


La peritonitis traumática del retículo esto directamente ligada a la ingestión de objetos metálicos punzantes, como clavos y trozos de alambre, que pueden penetrar o perforar la pared del retículo. Aunque la aparición de cuerpos extraños de aluminio es rara, se han registrado como causas de esta afección otros elementos, como los alambres de neumáticos utilizados para fijar las lonas al ensilaje e incluso las cerdas de alambre de los cepillos utilizados en los aeropuertos pequeños. La ingestión de estos objetos puede provocar daños en el retículo, desencadenando episodios de peritonitis traumática del retículo y sus secuelas, como pericarditis traumática, inflamación del hígado, abscesos del bazo y más. Los signos clínicos pueden variar, pero incluyen comportamiento anormal, motilidad ruminal reducida, heces mal digeridas, fiebre y signos de dolor. El diagnóstico se basa en la evaluación de los signos clínicos del animal, junto con pruebas complementarias, como hemograma, bioquímica, ecografía y radiografía. Es importante considerar los cambios hematológicos, como la leucocitosis y la hiperfibrinogenemia, como indicadores clave de esta afección. El diagnóstico también implica la prueba del dolor por cuerpo extraño. El tratamiento puede ser conservador o quirúrgico. El enfoque conservador implica la administración de antibióticos, antiinflamatorios y soluciones intravenosas, además de tratar las deficiencias nutricionales subyacentes. La opción quirúrgica requiere la extracción del cuerpo extraño del retículo, seguida de cuidados postoperatorios.


Subject(s)
Animals , Cattle , Peritonitis/veterinary , Foreign Bodies/veterinary , Gastrointestinal Motility
4.
Braz. dent. sci ; 27(1): 1-6, 2024. ilus
Article in English | LILACS, BBO | ID: biblio-1532548

ABSTRACT

Background: Odontogenic maxillary sinusitis caused by a foreign body presents diagnostic and therapeutic challenges due to its infrequent occurrence and unique characteristics compared to sinusitis originating from other sources. CaseReport:Illustrating such fact, this report presents the clinical case of a 37-year-old woman referred complaining of pain in the same region where she had extracted her upper right first molar five days before. The intraoral examination revealed the presence of an orifice in the region, suggesting oroantral communication. Imaging exams revealed opacification of the right maxillary sinus and the unexpected presence of a highly radiodense object. With the diagnosis of maxillary sinusitis due to a foreign body established, the surgical approach initially consisted of administering preoperative medication, preceded by access to the maxillary antrum using the Caldwell-Luc technique. The object was found and removed, consisting of a surgical drill. At follow-up there was complete absence of symptoms and complete closure of communication. Conclusion: Cases of odontogenic maxillary sinusitis caused by drill detachment after tooth extraction are fairly uncommon. A thorough clinical evaluation proved to be essential and the Caldwell-Luc access was effective, safe and with good postoperative results, even with the absence of standardized diagnostic and management methods(AU)


Contexto: A sinusite maxilar odontogênica causada por corpo estranho apresenta desafios diagnósticos e terapêuticos devido à sua ocorrência infrequente e características únicas em comparação com sinusites originadas de outras fontes. Relato do Caso: Ilustrando tal fato, este relato apresenta o caso clínico de uma mulher de 37 anos de idade encaminhada com queixa de dor em mesma região que havia extraído o primeiro molar superior direito cinco dias antes. Ao exame intraoral verificou-se a presença de um orifício na região, sugerindo comunicação oroantral. Os exames de imagem revelaram opacificação do SM direito e a inesperada presença de um objeto altamente radiodenso. Com o diagnóstico de sinusite maxilar por corpo estranho estabelecido, a abordagem cirúrgica consistiu inicialmente na administração de medicação pré-operatória, precedida pelo acesso ao antro maxilar através da técnica de Caldwell-Luc. O objeto foi encontrado e removido, consistindo em uma broca cirúrgica. Ao acompanhamento houve ausência completa dos sintomas e total fechamento da comunicação. Conclusão: Casos de sinusite maxilar odontogênica causada por descolamento da broca após extração dentária são bastante incomuns. Uma avaliação clínica minuciosa mostrou-se primordial e o acesso de Caldwell-Luc eficaz, seguro e com bons resultados pós-operatórios, mesmo com as ausências de métodos de diagnóstico e manejo padronizados.(AU)


Subject(s)
Humans , Female , Adult , Surgery, Oral , Maxillary Sinusitis , Oroantral Fistula
5.
Article | IMSEAR | ID: sea-218889

ABSTRACT

Aim And Background-A foreign body in nose presents with unilateral purulent nasal discharge, nasal obstruction and nasal bleed.We present a case in which a button battery remained uncomplicated in the nasal cavity for a year. However, if it is found, it should be removed as early as possible. A 6-year-old female child presented with aCase Description – one-year history of foul-smelling, left-sided nasal discharge. During anterior rhinoscopy, a black, rigid mass was observed. A circular foreign object was found in the floor of the left nasal cavity during a CT (computed tomography) scan of the Nose and PNS (paranasal sinuses). General anesthesia was used during the diagnostic nasal endoscopy on the child. A foreign body was visualized and removed using a curved curette. The nasal mucosa was normal on follow-up, and there was no septal perforation. A detailed history, assessment and radiological examination plays aConclusion- key role in management of foreign bodies.We report that a button battery was left in the nose for a long time without causing any problems. There were no complications from an unnoticed button battery in theClinical Significance: nose for a year. However, if it is found, it should be removed.

6.
Indian J Ophthalmol ; 2023 May; 71(5): 2324
Article | IMSEAR | ID: sea-225078

ABSTRACT

Background: A patient with a retained intraocular metallic foreign body post?trauma was taken up for vitrectomy and intraocular foreign body removal. Unfortunately, the intraocular magnet was not available at the moment on the table! How a little bit of creativity and innovative thought helped us tide over this crisis is the content of this video. Purpose: To demonstrate magnetization of a metallic surgical instrument for temporary use in the event of unavailability of the intraocular magnet for intraocular foreign body removal. Synopsis: A ferromagnetic substance can be magnetized temporarily using an existing magnet. We obtained a general?purpose magnet and wrapped it in sterile plastic, using which we magnetized normal intraocular forceps and a Micro Vitreo Retinal (MVR) blade by giving about 20–30 strokes over the magnet in a single direction. This aligned the magnetic domains in the metal in a parallel fashion. These Do It Yourself (DIY)? magnetic instruments were then effectively utilized to remove the metallic intraocular foreign body. Highlights: The video showcases effectively harnessing the available resources and tiding over the dearth of a necessary instrument, with the right use of an innovative idea and some creativity!.

7.
Article | IMSEAR | ID: sea-222308

ABSTRACT

Otitis media (OM) is a common problem involving children. In the majority, the cause is related to dysfunction of the Eustachian tube due to bacterial or viral rhinitis and less commonly due to nasopharyngeal tumors. We present a case of recurrent OM which was evaluated and incidentally found a nasal foreign body for which the patient was asymptomatic. This nasal body was the cause of recurrent OM which is very unusual.

8.
Article | IMSEAR | ID: sea-222449

ABSTRACT

Accidental entry of any foreign body into the paranasal sinus could be due to known causes or unknown causes with the patient being either symptomatic or sometimes asymptomatic. Such asymptomatic conditions make it difficult to detect the foreign body for an indefinite period which on a longer duration may lead to various complications later. Routine radiographic examination during dental checkup reports to serve a good purpose in these kinds of cases by accidental detection of such foreign bodies in the maxillofacial region leading to early diagnosis and timely management. The present paper highlights the importance of routine radiographs in detecting a rare type of foreign body (nasal stud) in the maxillary sinus in the asymptomatic patient.

9.
Article | IMSEAR | ID: sea-218812

ABSTRACT

Epistaxis in children is one of the most common referral dealt by an ENT outpatient department . Here we report a case of a 2-year-old girl who presented with complaints of recurrent episodes of epistaxis and discharge from the right nasal cavity since 1 month duration. Endoscopic examination of the right side of nose revealed a button battery impacted between the inferior turbinate and the cartilaginous portion of nasal septum

10.
Rev. cuba. med. mil ; 52(1)mar. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1521981

ABSTRACT

Introducción: El hallazgo de un cuerpo extraño retenido, específicamente una hoja de cuchillo es infrecuente. En ocasiones, estos cuerpos extraños pasan inadvertidos y se diagnostican de forma diferida o retrasada. Objetivo: Describir el diagnóstico y tratamiento de un paciente con una hoja de cuchillo retenida en el hueco de la axila. Caso clínico: Varón de 25 años, agredido con un cuchillo, que sufrió una herida en la región posterior del hombro y fue suturado sin realizar ningún examen complementario. Dos semanas después acudió por molestias en el hombro lesionado, se indicó radiografía en la cual apareció una imagen radiopaca que correspondió con una hoja de cuchillo en proyección subescapular. Refería molestias del hombro e impotencia funcional. Se opera con anestesia general, se realiza incisión axilar, se identifica el objeto, en íntimo contacto con la vena axilar; la punta hacia el vértice axilar, cruzando bajo la vena axilar en su entrada al tórax. Se extrajo el cuerpo extraño bajo visión directa, sin complicaciones. El paciente evolucionó favorablemente. Conclusiones: Los cuerpos extraños retenidos, que pasan inadvertidos son raros, sin embargo, existen regiones como la axila en que por las características anatómicas del espacio se dificulta su diagnóstico. En este caso coincidió una combinación poco usual de fenómenos, la actitud defensiva del lesionado y la dirección de la herida, que propiciaron quedara la hoja en el hueco axilar.


Introduction: The finding of a retained foreign body, specifically a knife blade, is a rare event. Sometimes these foreign bodies go unnoticed and are diagnosed deferred or delayed. Objective: To describe the diagnosis and treatment of a patient with a knife blade retained on axillary hole. Clinical case: 25-year-old male, attacked with a knife, who suffered a wound in the posterior region of the shoulder and was sutured without performing any complementary examination. Two weeks later, he came due to discomfort from the injured shoulder. An X-ray of the shoulder was indicated, where a radiopaque image appeared that corresponds to the knife blade, in subscapular projection. He refers shoulder discomfort and functional impotence. It is operated under general anesthesia, axillary incision, the object is identified in intimate contact with the axillary vein, the tip towards the axillary vertex, crossing under the axillary vein at its entrance to the thorax, the foreign body is removed under direct vision and without complications. Evolved favorably. Conclusions: Retained foreign bodies that go unnoticed are rare. However, there are regions such as the armpit where, due to the anatomical characteristics of the space, their diagnosis is difficult. In this case, an unusual combination of phenomena coincided, the defensive attitude of the injured person and the direction of the lunge, which led to the blade remaining in the axillary hole.

11.
Article | IMSEAR | ID: sea-222284

ABSTRACT

Penile strangulation due to the metallic ring is an uncommon clinical entity that requires urgent attention to prevent irreversible nerve damage, and if neglected gangrene of the penis. Various methods have been described in the literature for removing constricting foreign bodies, but there is no consensus regarding an acceptable technique. We report the case of a 51-year-old man with a history of a metal ring used for sexual pleasure lodged over the shaft of his penis with an inability to remove the same.

12.
Article | IMSEAR | ID: sea-220687

ABSTRACT

Background: Foreign body(FB) impaction accounts for 4% of emergency endoscopies in clinical practice. Flexible endoscopy(FE) is a recommended therapeutic option because it can be performed under local anesthesia, it is cost effective and is well tolerated. Rigid endoscopy (RG) under general anesthesia is another option and is advantageous in some circumstances. The aim of the study is to compare ef?cacy and safety of ?exible and rigid esophagoscopy in esophageal foreign body removal. It is a prospective study done in E.N.T department in KIMS Methods: MEDICAL COLLEGE, Amalapuram, which includes 50 patients with impacted foreign body esophagus. Parameters like type of foreign body, location of impacted foreign body are included. The study analyzies the type of procedure the patient have undergone, the intra operative and post operative complications. This prospective cohort study includes 50 patients Results: who have undergone surgical procedure for removal of impacted foreign body. Flexible esophagoscopy is performed in 30 patients and rigid esophagoscopy is performed in 20 patients . The most frequent complications are mucosal erosion, mucosal edema, and ulceration. Flexible esophagoscopy and rigid esophagoscopy are equally safe and effective for Conclusion: removal of impacted esophageal foreign body

13.
Indian J Ophthalmol ; 2023 Jan; 71(1): 300-302
Article | IMSEAR | ID: sea-224808

ABSTRACT

Facial foreign body (FB) is common after trauma, but iatrogenic orbital FB is a rare and unexpected complication of facial FB removal surgery. We present the case of a 43-year-old man with a glass FB in his nose. During the operation, this FB broke into two pieces, and the larger one pierced into the left orbit, close to the eyeball. A three-dimensional (3D) model was made that accurately recreated the shape and position of the FB in the orbit, according to which the FB was removed. 3D-printing technology is a great tool when dealing with complex facial FB.

14.
Chinese Journal of Applied Clinical Pediatrics ; (24): 504-509, 2023.
Article in Chinese | WPRIM | ID: wpr-990068

ABSTRACT

Objective:To explore the clinical application of magnetic foreign body extractor in metal foreign body of upper digestive tract children.Methods:The clinical data of 115 children with metallic foreign bodies in the upper digestive tract who were admitted to the Department of Pediatrics, the Second Affiliated Hospital of Air Force Medical University, from January 2017 to September 2022, were selected as subjects.All the metallic foreign bodies were removed by a self-made metallic foreign body extractor in the department.The clinical characteristics of the metallic foreign bodies in the upper digestive tract were comprehensively analyzed by using descriptive analysis methods, summarize the age, gender, metallic foreign body type, number of the metallic foreign bodies, incarcerated location, retention time, clinical symptoms and complications.Results:A total of 115 children with metallic foreign bodies in the upper digestive tract were included in the analysis, involving 51 males and 64 females, with a mean age of (3.63±2.28) years.The majority was children aged 0-3 years (68/115, 59.1%). Coins (86 cases, 74.8%) were the major foreign bodies in metal foreign body of upper digestive tract, followed by button batteries (11 cases, 9.6%), magnetic balls (8 cases, 7.0%), and others (10 cases, 8.6%). The main clinical symptoms were nausea, vomiting, abdominal pain, chest pain, and foreign body sensation, and button battery ingestion and magnetic balls were easy to produce complications.The primary retention sites of metallic foreign bodies were the gastric fundus (75 cases, 65.2%), followed by upper esophageal segment (38 cases, 33.0%) and lower esophageal segment(2 cases, 1.7%).Conclusions:In children′s metal foreign body of upper digestive tract, coins are the most common foreign bodies that are easily retained in the stomach fundus.Button batteries are prone to cause severe complications and should be removed timely.The self-made metallic foreign body extractor in our department can remove coins, batteries, magnetic balls, nails, chains, party emblems and other metallic foreign bodies.It can shorten the operation time, improve the removal efficiency, and featured by active search, strong adsorption, no mucosal damage and removal with the endoscope, which can be widely used in the clinical treatment of metallic foreign bodies.

15.
Philippine Journal of Ophthalmology ; : 82-86, 2023.
Article in English | WPRIM | ID: wpr-1003661

ABSTRACT

Objective@#To present a case of transorbital penetrating intracranial injury successfully managed using a stepwise multispecialty approach.@*Methods@#This is a case report.@*Results@#A 26-year-old male presented with a motorcycle side-mirror metal bar impaled into his right orbit. He had a Glasgow Coma Scale (GCS) score of 12. Computed tomography (CT) imaging revealed the metal bar’s trajectory from the right lateral canthus, traversing the superior orbital wall and frontal lobe, resulting in contusion, intracranial hemorrhages and multiple orbital and facial fractures. Despite the severity of the injury, the right globe was found to be intact during intraoperative exploration. The transorbital approach was employed for safe removal of the penetrating object, followed by repair of full-thickness eyelid laceration and transections of the lateral and medial canthi. Subsequently, the Neurosurgery service conducted a right pterional craniotomy, debridement, and duraplasty. Upon discharge, the visual acuity on the right eye was 20/50.@*Conclusion@#Transorbital penetrating intracranial injuries are rare and result in vision loss and life-threatening complications. A transorbital approach in removing a penetrating foreign body can be adopted when injury to cerebral tissues is imminent. Individualizing the management and employing a multispecialty approach can lead to favorable outcomes.

16.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 1016-1021, 2023.
Article in Chinese | WPRIM | ID: wpr-998994

ABSTRACT

ObjectiveTo investigate the clinical value of DR corneal suture ring localization and CT 3D reconstruction localization of orbital foreign bodies. MethodsRetrospective analysis was performed on patients (51 cases) suspected of ocular foreign bodies admitted to our hospital from January 2016 to December 2020 At the same time, DR corneal suture ring localization and CT three-dimensional reconstruction localization of orbital foreign bodies were performed, and the detection rate of foreign bodies by the two methods was calculated to analyze the location of ocular foreign bodies. ResultsThere were 38 cases of intraorbital foreign body identified by DR corneal suture ring localization method, and 46 cases of intraorbital foreign body identified by CT three-dimensional reconstruction localization method. The accuracy of CT three-dimensional reconstruction localization method was 90.20%, which was higher than that of DR corneal suture ring localization method 74.51% (P<0.05). Intraocular foreign bodies in 23 cases could be distinguished by DR corneal suture ring localization, and 25 cases by CT 3D reconstruction localization. The maximum diameter of intraocular foreign bodies that could be distinguished by CT 3D reconstruction localization was (2.65±0.14) mm. The diameter of intraspherical foreign body was (2.94±0.36) mm (P<0.05) lower than that which could be distinguished by DR corneal suture ring localization method. The results of DR corneal suture ring localization of orbital foreign body showed no difference compared with the results of CT 3D reconstruction localization (P>0.05). Forty cases of high density images inside and outside the eye could be clearly distinguished by CT 3D reconstruction. By using DR corneal suture ring localization method, 23 cases were confirmed to be intraocular high-density shadows, and 15 cases could not be confirmed to be intraocular high-density shadows (P < 0.05). ConclusionsFor the location of intraorbital foreign bodies, CT three-dimensional reconstruction can be used as a conventional method for locating ocular foreign bodies with high resolution and accuracy, and can detect fine metal particles inside the eyeball. Meanwhile, for a few small foreign bodies in the iris root, ciliary body and lateral suspension ligament, it is necessary to locate orbital foreign bodies with DR corneal suture ring.

17.
Malaysian Journal of Medicine and Health Sciences ; : 428-430, 2023.
Article in English | WPRIM | ID: wpr-998646

ABSTRACT

@#Foreign body aspiration is uncommon in adults who have no known risk factors such as mental retardation, poor dentition, or advanced age. Adults with foreign body aspiration are commonly misdiagnosed with bronchial asthma, however, does not respond to standard bronchodilator treatment. A thorough history-taking, focused physical examination and a high index of suspicion is crucial in making the correct diagnosis. This paper reports an interesting case of a 41- year-old woman with an undetected 10-year long foreign body aspiration which was misdiagnosed as bronchial asthma.

18.
Acta Anatomica Sinica ; (6): 244-248, 2023.
Article in Chinese | WPRIM | ID: wpr-1015231

ABSTRACT

Objective To design and validate a novel surgical guide for retrieval of foreign body in jaw. Methods Firstly, a surgical guide based on cone beam computed tomography and trephine technique was designed to remove broken dental instrument fragments. Its feasibility and accuracy were assessed by removing broken dental instrument in goat mandible, and then it was successfully applied in clinical cases. The linear and angular discrepancies between actual and planned columnar bone with imaginary fragment was analyzed. The euclidean distance was measured at the hex and apex of the columnar bone and the angle of axis deviation was also calculated. We obtained seven parameters (cdh, cda, hdh, hda, vdh, vda, and ad) to describe deviations. Results Mean central deviation at the hex and apex was (0.51 ± 0.14) mm and (0.62 ± 0.19) mm, respectively. Accompanying mean values were as follow: horizontal deviation at the hex was (0.48 ± 0.16) mm, horizontal deviation at the apex was (0.52 ± 0.22) mm, vertical deviation at the hex was (0.17 ± 0.09) mm, vertical deviation at the apex was (0.29 ± 0.13) mm, and angular deviation of (5.38 ± 3.43) degrees. In a clinical case, the guide successfully located and removed the fracture file. Conclusion This study reveals that this kind novel surgical guide could aid to locate and remove the foreign body in jaw.

19.
International Eye Science ; (12): 700-703, 2023.
Article in Chinese | WPRIM | ID: wpr-965804

ABSTRACT

AIM: To analyze the incidence and disease burden of foreign body in eyes in 1990 and 2019 of China.METHODS: Using the global burden of disease database in 2019, the incidence and disability adjusted life years(DALY)of foreign body in eyes in 1990 and 2019 of China were analyzed among the total population and different age groups of China.RESULTS: In 2019, the number of cases of foreign body in eyes in China was 11.2535 million, and the incidence was 79.12/10 000. The number and incidence of foreign body in eyes in 2019 decreased 12.87% and 27.49% respectively compared with those in 1990. In 2019, the DALY of foreign body in eyes in China was 181 200 person-years, and the DALY of foreign body in eyes in 2019 increased by 6.14% compared with 1990. In 2019, the age groups with the highest number of cases, incidence and DALY were all 20-54 years old, which were 8 012 600, 103.97/10 000 and 102 500 person-years, respectively. From 1990 to 2019, the incidence of foreign body in eyes in China showed a decreasing trend, average annual percentage change(AAPC)=-1.2%(95%CI: -1.8~-0.7, P&#x0026;#x003C;0.05), and DALY rate also showed a decreasing trend, AAPC=-0.6%(95%CI:-2.1~0, P&#x0026;#x003C;0.05). From 1990 to 2019, the incidence and DALY rate of foreign body in eyes in China and the World showed a downward trend. In 2019, the incidence and DALY rate of foreign body in eyes in China were significantly higher than those in the World and regions with different sociodemographic index(SDI).CONCLUSION: Although the incidence and DALY rates of foreign body in eyes in China have been decreasing in recent years, China has a large population base and the burden of foreign body in eyes is still large in the World. Active preventive measures should be taken to reduce the disease burden of foreign body in eyes.

20.
Journal of Zhejiang University. Science. B ; (12): 510-523, 2023.
Article in English | WPRIM | ID: wpr-982391

ABSTRACT

Foreign body reactions induced by macrophages often cause delay or failure of wound healing in the application of tissue engineering scaffolds. This study explores the application of nanosilver (NAg) to reduce foreign body reactions during scaffold transplantation. An NAg hybrid collagen-chitosan scaffold (NAg-CCS) was prepared using the freeze-drying method. The NAg-CCS was implanted on the back of rats to evaluate the effects on foreign body reactions. Skin tissue samples were collected for histological and immunological evaluation at variable intervals. Miniature pigs were used to assess the effects of NAg on skin wound healing. The wounds were photographed, and tissue samples were collected for molecular biological analysis at different time points post-transplantation. NAg-CCS has a porous structure and the results showed that it could release NAg constantly for two weeks. The NAg-CCS group rarely developed a foreign body reaction, while the blank-CCS group showed granulomas or necrosis in the subcutaneous grafting experiment. Both matrix metalloproteinase-1 (MMP-1) and tissue inhibitor of metalloproteinase-1 (TIMP-1) were reduced significantly in the NAg-CCS group. The NAg-CCS group had higher interleukin (IL)-10 and lower IL-6 than the blank CCS group. In the wound healing study, M1 macrophage activation and inflammatory-related proteins (inducible nitric oxide synthase (iNOS), IL-6, and interferon-‍γ (IFN-‍γ)) were inhibited by NAg. In contrast, M2 macrophage activation and proinflammatory proteins (arginase-1, major histocompatibility complex-II (MHC-II), and found in inflammatory zone-1 (FIZZ-1)) were promoted, and this was responsible for suppressing the foreign body responses and accelerating wound healing. In conclusion, dermal scaffolds containing NAg suppressed the foreign body reaction by regulating macrophages and the expression of inflammatory cytokines, thereby promoting wound healing.


Subject(s)
Animals , Rats , Swine , Interleukin-6 , Macrophage Activation , Tissue Inhibitor of Metalloproteinase-1 , Wound Healing , Foreign-Body Reaction , Foreign Bodies , Chitosan
SELECTION OF CITATIONS
SEARCH DETAIL