Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Biochemical Pharmaceutics ; (6): 21-23, 2017.
Article in Chinese | WPRIM | ID: wpr-613953

ABSTRACT

Objective A high performance liquid chromatographic (HPLC) method was established for the determination of glycerol in propofol medium and long chain fat emulsion injection.MethodsThe chromatographic conditions were as follows: Kromasil 100-5-NH2 column(4.6×250mm,5μm) with the column temperature was 40℃,acetonitrile-water(8515)as mobile phase with flow rate of 1.0mL/min.Glycerol was detected by refractive index (RI) detector at 40℃.ResultsThe linear range of glycerol was 455.3916-2276.9580μg/mL(r=0.9999,n=7),the average recovery rate was 99.5%,RSD was 0.6%(n=9),the limit of detection(LOD) was 121ng and the limit of quantification(LOQ)was 364ng.ConclusionThe method was simple, rapid, strong specifity and accurate with good reproducibility, which is suitable for the content determination of glycerol in propofol medium and long chain fat emulsion injection.

2.
Chinese Journal of Biochemical Pharmaceutics ; (6): 191-193, 2016.
Article in Chinese | WPRIM | ID: wpr-496384

ABSTRACT

Objective A high performance liquid chromatographic (HPLC) method was established for the simultaneous determination of xylitol and L-xylulose in fermentation broth.Methods The chromatographic conditions were as follows:C18 column (250 mm ×4.6 mm) with the temperature 35℃, acetonitrile-water (85∶15,v/v)as mobile phase with the flow rate of 0.8 mL/min.Xylitol was detected by refractive index (RI) detector at 33℃and L-xylulose was determined by ultraviolet ( UV) detector at 210 nm at room temperature.Results This method showed good linearity over the range from 0.50~30.00 g/L with a correlation coefficient of 0.9995 for xylitol and 0.30~30.00 g/L with a correlation coefficient of 0.9986 for L-xylulose. Moreover, the limit of quantification (LOQ) for xylitol and L-xylulose were 0.58 and 0.40,respectively.The limit of determination (LOD) for xylitol and L-xylulose were 0.18 and 0.15,respectively.The relative standard deviations (RSDs) of intraday and interday for xylitol were less than 0.64%and 0.80%,respectively.The intraday and interday RSDs for L-xylulose were less than 0.31%and 0.59%.The recoveries of xylitol and L-xylulose in fermentation broth were between 99.00%-101.00%.Conclusion There was no interference from other constitutes in the fermentation broth by this method.The methods were suitable for the simultaneous determination of the substrate xylitol and the product L-xylulose in fermentation process.

3.
Chinese Journal of Forensic Medicine ; (6)1986.
Article in Chinese | WPRIM | ID: wpr-673180

ABSTRACT

The Content of LT B_4 in the edge of 36 SD rats were determined by HPLC. It was found that the content of LTB_4 in the anternortem wounds is markedly increased, and has certain linear relationship with time of injury within one hour. No increasing of LTB_4 could be found in the postmortem wounds. It indicates that it is very valuable to estimate time of injury by determining LT B_4 content in wound edge, The content of LTB_4 in wound edge can be determined rapidly and accurately with HPLC.

SELECTION OF CITATIONS
SEARCH DETAIL