Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Chinese Journal of Medical Education Research ; (12): 284-288, 2023.
Article in Chinese | WPRIM | ID: wpr-991306

ABSTRACT

Objective:To explore the application effect of case-based learning (CBL) and lecture-based learning (LBL) in the teaching of image post-processing course in the standardized training system of medical imaging technology.Methods:A total of 34 trainees in the standardized training of imaging technology of Batch 2018 in West China Hospital of Sichuan University were divided into the experimental group and the control group according to their student numbers, with 17 students in each group. CBL teaching was carried out in the experimental group, and LBL teaching was carried out in the control group. According to the standardized training course design, after one year of image post-processing course teaching, the teaching effect was evaluated through closed-book examination, questionnaire survey and post-processing test. SPSS 20.0 was used for t-test and Mann-Whitney U test. Results:The scores of closed-book examinations (74.42±6.10) and post-processing test (73.47±6.03) in the experimental group were higher than those in the control group [(69.11±3.70) and (69.08±6.51)], and the difference was statistically significant ( P<0.05). The questionnaire survey showed that the students in the experimental group recognized CBL teaching in terms of learning interests stimulation, classroom atmosphere mobilization, clinical thinking cultivation, self-study ability training, and analysis of difficult and rare cases, etc. Conclusion:In the image post-processing course of standardized training of medical imaging technology, the rational application of CBL teaching mode is helpful to improve students' learning enthusiasm, self-learning ability, comprehensive analysis of clinical ability, practical ability, innovation consciousness and so on.

2.
Journal of Practical Radiology ; (12): 762-764, 2017.
Article in Chinese | WPRIM | ID: wpr-614021

ABSTRACT

Objective To investigate the value of post processing technique of MSCT in the diagnosis of bile duct stones.Methods 89 cases with high density bile stones were collected.All of the images were reconstructed by using surface reconstruction(CPR),multiplanar reconstruction(MPR),volume reconstruction(VR), to clearly show the location, size, number and shape of bile duct stones, and provide accurate image information for clinic.Results 396 cases of bile duct stones were detected in all of the 89 patients,after treatment,the reconstructed image of could accurately show the location,size,number and shape of stones.Conclusion Post-processing technique of MSCT can provide accurate image information for the diagnosis of the the biliary stone,and improve the effectiveness and safety of the operation.

3.
Journal of the Korean Society of Laryngology Phoniatrics and Logopedics ; : 89-95, 2017.
Article in Korean | WPRIM | ID: wpr-13304

ABSTRACT

BACKGROUND AND OBJECTIVES: High-speed videolaryngoscopy (HSV) is the only technique that captures the true intra-cycle vibratory behavior of the vocal folds by capturing full images of the vocal folds. However, it has problems of no immediate feedback during examination, considerable waiting time for digital kymography (DKG), recording duration limited to a few seconds, and extreme demands for storage space. Herein, we demonstrate a new post-processing method that converts HSV images to two-dimensional digital kymography (2D-DKG) images, which adopts the algorithm of 2D videokymography (2D VKG). MATERIALS AND METHODS: HSV system was used to capture images of vocal folds. HSV images were post-processed in Kay image-process software (KIPS), and conventional DKG images were retrieved. Custom-made post-processing system was used to convert HSV images to 2D-DKG images. The quantitative parameters of the post-processed 2D-DKG images was validated by comparing these parameters with those of the DKG images. RESULTS: Serial HSV images for all phases of vocal fold vibratory movement are included. The images were converted by the scanning method using U-medical image-process software. Similar to conventional DKG, post-processed 2D DKG image from the HSV image can provide quantitative information on vocal fold mucosa vibration, including the various vibratory phases. Differences in amplitude symmetry index, phase symmetry index, open quotient, and close quotient between 2D-DKG and DKG were analyzed. There were no statistical differences between the quantitative parameters of vocal fold vibratory movement in 2D-DKG and DKG. CONCLUSION: The post-processing method of converting HSV images to 2D DKG images could provide clinical information and storage economy.


Subject(s)
Kymography , Methods , Mucous Membrane , Vibration , Vocal Cords , Voice
4.
Journal of Practical Radiology ; (12): 533-536, 2010.
Article in Chinese | WPRIM | ID: wpr-402747

ABSTRACT

Objective To evaluate the diagnostic value of 64-slice VCT reconstruction techniques in the diseases of joints of foot and hand.Methods 50 patients with diseases of joints of foot and hand underwent MSCT scans,the data were reconstructed,including multiplanar reconstruction(MPR),maximum intensity projection(MIP),shaded surface display(SSD)and volume rendering(VR),the results were analysed.Results 33 patients with fractures,40 and 51 fractures were found by X-ray and MPR,VR,respectively.The joint surface involved in 7 fractures,which was best with VR and MPR to show the whole fractures.SSD was better to demonstrate the soft tissue and the vessels of the skin.3D bone reconstruction with MIP was better than plain film in showing the fractures in 4 patients with plaster external fixation.Conclusion 64-slice VCT reconstruction techniques are effective in diagnosis of the diseases of joints of foot and hand.

5.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-595843

ABSTRACT

Objective To evaluate the auxiliary diagnostic ability and applicability of the Lung Care software of dualsource CT in the study of solitary pulmonary nodule(SPN). Methods 40 cases with SPN proved by pathologically were examined by dual-source CT. R-MPR and VOI of Lung Care software three-dimension rebuilding image were obtained to analyze imaging features of SPN and compared with routine chest CT. 20 cases had regular visits during 12 months which were divided into three stages to measure the growing speed or doubling time. Results There were 28 cases of malignant nodules and 12 cases of benign nodules in 40 cases of SPN. The accuracy for malignancy of routine chest CT and LungCare software three-dimension rebuilding are 53.57% ,82.14% respectively. The accuracy for benign nodules is 41.67%,83.33% respectively. Both are significant difference (P

6.
Journal of Practical Radiology ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-540376

ABSTRACT

Objective To assess the value in detecting the tracheobronchial tree invasion by central lung cancer (CLC)using MSCT axial images and 4 kinds of images post-processed techniques.Methods 38 cases with CLC identified by fibrobrochoscopy or operation were scanned using MX8000 scanner with slice thickness of 3.2 mm, overlapping interval of 1.6 mm, pitch of 1.0. Multiplanar reformation(MPR), shaded surface display(SSD), volume rendering (VR) and virtual endoscopy(VE) were performed in all cases. Two radiologists assessed the invasion of tracheobronchial tree by CLC together.The imaging findings were compared with the data of surgery in 12 cases who were undergone operation.Results 38 cases of CLC, 0 grade to Ⅳ grade were assessed in 0,8,14,11 and 5 cases respectively by MSCT axial images, while in 0,10,11,12 and 5 cases by MSCT post-processing images. The concordance rate was 75% for MSCT axial images(n=9), and 100% for MSCT post-processing images(n=12) among 12 cases performed operation(? 2 test,? 2=6.0,P

SELECTION OF CITATIONS
SEARCH DETAIL