1.
Indian Heart J ; 2019 Jul; 71(4): 297-302
Article | IMSEAR | ID: sea-191694

ABSTRACT

Background We aimed to assess the decrease in contrast media volume (CMV) with ultra-low contrast delivery technique (ULCD) developed at our institution versus the usual automated contrast injector system (ACIS) contrast delivery in coronary procedures. Methods We analyzed the amount of contrast given in the consecutive 204 patients of the operators who use ULCD technique versus consecutive 200 patients of the other operators who use ACIS without ULCD technique for coronary angiograms and/or percutaneous coronary interventions (PCIs) from May 2017 to July 2018 at our center. We calculated the mean CMV between these groups. Results We observed a significant reduction in mean CMV with ULCD technique versus standard ACIS, respectively: angiogram 24.8 ± 15.8 mL (n = 194) vs 42.3 ± 25.1 mL (n = 200) (p < 0.0001); PCI 23.5 ± 19.7 mL (n = 52) vs 48.2 ± 30.8 mL (n = 16) (p < 0.0070); angiogram with ad hoc PCI 53.4 ± 32.1 mL (n = 23) vs 89.7 ± 35.6 mL (n = 16) (p < 0.0024); and overall angiogram and PCI 27.4 ± 20.5 mL (n = 204) vs 44.9 ± 28.0 mL (n = 181) (p < 0.0001). Conclusion Our study showed a highly significant reduction in CMV using ULCD technique compared to standard ACIS contrast delivery in coronary invasive procedures. Even in the standard ACIS arm, CMV was significantly lower than values reported in literature, possibly due to operators' bias toward contrast preservation.

2.
Korean Journal of Ophthalmology ; : 87-92, 2013.
Article in English | WPRIM | ID: wpr-143920

ABSTRACT

PURPOSE: To investigate effects of a new push-through insertion method for donor lenticules using an injector system on endothelial viability ex vivo and in a clinical case series of endothelial keratoplasty. METHODS: An ex vivo delivery model was used with porcine corneoscleral rims. We compared the endothelial viability in a new push-through insertion method using the Visian Implantable Collamer Lens (ICL) injector versus that of standard forceps-assisted insertion for lenticule delivery. Twenty porcine corneal lenticules were divided into four groups by insertion method and wound size. Vital dye staining was performed and devitalized areas were semi-quantitatively assessed by digital imaging. In the clinical case series, Descemet's stripping endothelial keratoplasty (DSEK) using the push-through method was performed in seven patients and endothelial outcome was determined six months postoperatively. RESULTS: Mean devitalized areas for the push-through method were significantly lower than for forceps-assisted insertion through 3.2 mm incision (23.99 +/- 2.17% vs. 50.48 +/- 5.07%, p = 0.009) in the ex vivo model. Average endothelial cell counts of donor tissues of patients who underwent DSEK were 26.4% lower six months postoperatively. CONCLUSIONS: Push-through delivery of donor lenticules using the Visian ICL injector system appears to be less harmful to endothelial cells than conventional forceps-assisted delivery.


Subject(s)
Animals , Corneal Endothelial Cell Loss/prevention & control , Descemet Stripping Endothelial Keratoplasty/methods , Lens Implantation, Intraocular/instrumentation , Lenses, Intraocular , Models, Animal , Postoperative Complications/prevention & control , Prosthesis Design , Swine
3.
Korean Journal of Ophthalmology ; : 87-92, 2013.
Article in English | WPRIM | ID: wpr-143913

ABSTRACT

PURPOSE: To investigate effects of a new push-through insertion method for donor lenticules using an injector system on endothelial viability ex vivo and in a clinical case series of endothelial keratoplasty. METHODS: An ex vivo delivery model was used with porcine corneoscleral rims. We compared the endothelial viability in a new push-through insertion method using the Visian Implantable Collamer Lens (ICL) injector versus that of standard forceps-assisted insertion for lenticule delivery. Twenty porcine corneal lenticules were divided into four groups by insertion method and wound size. Vital dye staining was performed and devitalized areas were semi-quantitatively assessed by digital imaging. In the clinical case series, Descemet's stripping endothelial keratoplasty (DSEK) using the push-through method was performed in seven patients and endothelial outcome was determined six months postoperatively. RESULTS: Mean devitalized areas for the push-through method were significantly lower than for forceps-assisted insertion through 3.2 mm incision (23.99 +/- 2.17% vs. 50.48 +/- 5.07%, p = 0.009) in the ex vivo model. Average endothelial cell counts of donor tissues of patients who underwent DSEK were 26.4% lower six months postoperatively. CONCLUSIONS: Push-through delivery of donor lenticules using the Visian ICL injector system appears to be less harmful to endothelial cells than conventional forceps-assisted delivery.


Subject(s)
Animals , Corneal Endothelial Cell Loss/prevention & control , Descemet Stripping Endothelial Keratoplasty/methods , Lens Implantation, Intraocular/instrumentation , Lenses, Intraocular , Models, Animal , Postoperative Complications/prevention & control , Prosthesis Design , Swine
4.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-584130

ABSTRACT

At present, a kind of equipment for medical imaging enhancement , high-pressure injector system, has been applied widely to such medical fields as Angiography, DSA, CT and MR. This paper introduces the technology progress, use and purchase of this product.