Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Type of study
Language
Year range
1.
Orthopedic Journal of China ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-543987

ABSTRACT

[Objective]To investigate the causes and treatment methods of postoperative complications of femoral fractures treated with interlocking intramedullary nails.[Method]A total of 243 cases of femoral fractures from Jan 1999 to Dec 2004 were treated with interlocking intramedullary nails.There were 14 cases having complications,delayed union in 1,nonunion in 3,nailing failure in 6(locking scerw loosen in 4,locking scerw folding in 1,locking scerw breakage in 2),nail breakage in 1,re-fracture in 1 and knee ankylosis in 1.Two cases with delayed union to convert the fixation from statictody namicin time;3 cases with nonunion were treated with bone grafting.Breakage nail and re-fractuer cases were treated with enlarging intramedullary tunels,exchanging nails and bone grafting.One of locking scerw loosen were treated with exchanging nails and bone grafting.Knee ankylosis were treated with quadriceps plasty.[Result]Through treatment,the delayed union and the nonunion were all healed and got recovery of knee function.[Conclusion]Though it has certain complications,the interlocking intramedullary nails used for femoral fractures have more advantages than other internal fixations.It needs to take valid measures to reach a satisfying result when complication appears.

2.
Orthopedic Journal of China ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-546323

ABSTRACT

[Objective]Ulnar fractures fixed by interlocking intramedullary nails or dynamic compression plates were tested to compare their biomechanical function,in order to provide the theoretical basis for clinical practice.[Method]In the experiment,12 pieces of fresh ulnars were used to produce middle-part transverse fracture models;which were fixed by interlocking intramedullary nails or six-hole 3.5 mm dynamic compression plates seperately.The diameter of intramedullary nail was 4mm,and the length was 200-230mm.The specimen was set on the MTS test machine.The rigidity and strength of ulnar fractures fixed by interlocking intramedullary nails were compared with those of ulnar fractures fixed by six-hole 3.5 mm dynamic compression plates in the anti-axial test,anti-bending test,anti-torsional test.[Result]In the anti-axial test,anti-bending test and anti-torsional test,the rigidity of ulnar fractures fixed by interlocking intramedullary nails was 450.00?38.42 N/mm,45.64?5.24 N?cm/Deg,11.42?1.21N?cm/Deg in sequence;while the rigidity fixed by dynamic compression plates was 405.40?29.26 N/mm,41.00?4.78 N.cm/Deg,10.05?1.32 N?cm/Deg accordingly.Burdened 1000N axial pressure,the displacement of interlocking intramedullay nail fixing specimen was 2.20?0.11 mm,and the compression plate fixing specimen was 2.48?0.15 mm.Given a 5 N?M bending burden,the maximum radial bending degree of interlocking intramedullay nailfixing specimen was 3.25?0.15 mm,which was 3.60?0.21 mm of compression plate fixing specimen.In the anti-torsional test,the interlocking intramedullay nail and compression plate fixing specimen could burden 2.40?0.13 N?M and 1.90?0.10 N?M respectively.The experimental data were analyzed by software SPSS.10,which came to a distinguished difference by t-test(P

SELECTION OF CITATIONS
SEARCH DETAIL