1.
International Eye Science ; (12): 106-110, 2024.
Article in Chinese | WPRIM | ID: wpr-1003516

ABSTRACT

AIM: To compare the short-term postoperative visual acuity, visual disturbance phenomena, and spectacle independence rate in patients who underwent monocular implantation with trifocal, multifocal, or extended range of vision intraocular lens(IOL).METHODS: A retrospective analysis was conducted on 67 cataract patients(67 eyes)who underwent phacoemulsification cataract extraction combined with IOL implantation from March 2019 to December 2022. A total of 35 cases(35 eyes)received Symfony extended range of vision IOL implantation, 21 cases(21 eyes)received AcrySof IQ ReSTOR +3D multifocal IOL, and 11 cases(11 eyes)received AcrySof IQ PanOptix trifocal IOL. The preoperative uncorrected distance visual acuity(UDVA), uncorrected intermediate visual acuity(UIVA), and uncorrected near visual acuity(UNVA)and 3 mo postoperatively were documented. Moreover, defocus curves, visual disturbance phenomena, and spectacle independence rates were recorded at 3 mo postoperatively.RESULTS: At 3 mo postoperatively, no statistically significant differences were observed in UDVA among the three groups(P>0.05). A comparison of UIVA showed superior results in the Symfony and PanOptix groups compared to the ReSTOR group(all P<0.01). The UNVA of both the ReSTOR and PanOptix groups outperformed the Symfony group(all P<0.01). The defocus curves indicated that in the intermediate vision range(-1.00 to -1.50 D), the Symfony group exhibited better performance than the ReSTOR group(P<0.05); while in the near vision range(-2.50 to -3.50 D), the ReSTOR group was superior to the Symfony group(P<0.05). The PanOptix group demonstrated superior visual acuity in the near vision range(-2.00 to -3.50 D)compared to the Symfony group(P<0.05)and was also superior in the intermediate vision range(-1.00 to -2.00 D)compared to the ReSTOR group(P<0.05). No significant differences were observed in the incidence of glare or halo and binocular interference phenomena among the three groups(P>0.05). The PanOptix and ReSTOR groups exhibited a higher spectacle independence rate compared to the Symfony group(P<0.0167).CONCLUSION: Compared to Symfony extended range of vision IOL and ReSTOR multifocal IOL, PanOptix trifocal IOL offers a balanced approach to distance, intermediate, and near visual acuity, without a high incidence of glare and halo, and with a higher spectacle independence rate. Caution is still advised when considering monocular implantation with presbyopia-correcting IOLs.

2.
International Eye Science ; (12): 93-96, 2024.
Article in Chinese | WPRIM | ID: wpr-1003513

ABSTRACT

With the wide application of phacoemulsification and intraocular lens implantation, many cataract patients have effectively recovered vision. Postoperative intraocular lens opacification is an important indicator for evaluating biocompatibility, as it affects the visual quality of patients. The manifestation and risk factors of opacification vary among different materials used for intraocular lenses. However, better visual quality after surgery is not determined by a single factor. The material of the intraocular lens and the patient's response to the intraocular lens are all factors that affect the postoperative visual quality. With the continuous advancement of technology, an increasing number of new materials are being applied in the field of intraocular lenses. Fully understanding the characteristics of intraocular lens materials, selecting suitable intraocular lens for patients and reducing complications caused by materials will be beneficial to patients. The characteristics of different intraocular lens materials and the risk factors of opacification after intraocular lens implantation were discussed in this paper.

3.
International Eye Science ; (12): 641-645, 2024.
Article in Chinese | WPRIM | ID: wpr-1012836

ABSTRACT

AIM: To evaluate the accuracy of the formulas, including Haigis, SRK/T, Holladay 1, and Holladay 2, in predicting the diopter of the intraocular lens implanted in high myopia cataract patients.METHODS: Prospective study. A total of 168 cases(168 eyes)of age-related cataract with an axial length(AL)≥26 mm who were treated in our hospital from August 2017 to November 2021 were selected. According to the preoperative AL measured by IOL Master 700, the patients were divided into five groups, including 37 cases(37 eyes)in group A with 26 mm≤AL<27 mm, 34 cases(34 eyes)in group B with 27 mm≤AL<28 mm, 42 cases(42 eyes)in group C with 28 mm≤AL<29 mm, 28 cases(28 eyes)in group D with 29 mm≤AL<30 mm, and 27 patients(27 eyes)in group E with AL ≥ 30 mm. Subjective refraction was performed at 3 mo postoperatively, and the mean numerical error(MNE)and mean absolute error(MAE)of each formula for predicting diopters were calculated.RESULTS: The MNE and MAE of the Haigis and Holladay 2 formulas were relatively less in each group, and MNE and MAE did not significantly increase with the growth of the axial length. However, the MAE and MNE of the SRK/T and Holladay 1 formulas significantly increased with the growth of the axial length, with the MNE and MAE of the Holladay 1 formula increasing more significantly in groups C, D, and E.CONCLUSION: For patients with age-related cataract, with an axial length of ≥26 mm, the accuracy of predicting the diopter of the intraocular lens using the Haigis and Holladay 2 formulas were higher.

4.
International Eye Science ; (12): 612-617, 2024.
Article in Chinese | WPRIM | ID: wpr-1012831

ABSTRACT

AIM:To compare the differences, correlations and consistency of IOL Master 700 or Lenstar LS900 in preoperative ocular biometry and the accuracy of intraocular lens(IOL)degree calculation of cataract patients with high myopia.METHODS: Retrospective study. A total of 136 cases(136 eyes)of high myopia and cataract patients who underwent phacoemulsification at the ophthalmology department of Army Medical Center of PLA from March 2021 to March 2023 were collected, with a mean age of 57.38±8.08 years. Patients were divided into 3 groups based on axial length(AL): 41 eyes in group A(26 mm≤ AL ≤28 mm), 43 eyes in group B(28 mm< AL ≤30 mm)and 52 eyes in group C(AL >30 mm). AL, mean keratometry(Km), anterior chamber depth(ACD), lens thickness(LT)and white-to-white(WTW)were preoperatively measured by two instruments, respectively. Barrett Universal II formula was used to calculate the IOL degrees of all patients, the appropriate reserved diopter was decided individually, and the prediction error(PE)and absolute error(AE)of the two instruments were compared.RESULTS:The AL and ACD of patients in the three groups measured by Lenstar LS900 were higher than the AL measurd by IOL Master 700(all P<0.05), with a difference of AL measured by the two devices: group C>group B>group A. However, there was no statistical significance in LT, Km, and WTW measured by the two instruments(all P>0.05). All biometric parameters measured by the two devices were positively correlated(all r>0.9, P<0.05), and consistent(95% LoA of all groups were narrow). There was no statistically significant difference in AE calculated by the two devices(P>0.05), but the IOL Master 700 calculated a smaller PE than Lenstar LS900(P<0.05), with lower percentage of hyperopic shift in IOL Master 700.CONCLUSION:In cataract patients with high myopia, AL measured by Lenstar LS900 is longer than that by IOL Master 700, and the differences of AL increase along with the growth of AL. Both devices have a good prediction for IOL calculation, but IOL Master 700 has less refractive error, lower percentage of hyperopic shift, and greater clinical advantages IOL Master 700.

5.
International Eye Science ; (12): 545-550, 2024.
Article in Chinese | WPRIM | ID: wpr-1012818

ABSTRACT

In recent years, the combined surgery of phacoemulsification, intraocular lens implantation, and goniosychialysis has gradually emerged as a primary and effective approach in treating primary angle-closure glaucoma with cataracts. However, with the continuous progress of medical technology, postoperative intraocular pressure control is no longer the sole pursuit. Patients increasingly aspire to achieve higher postoperative visual quality. In order to ensure that patients attain a better refractive status and higher visual quality postoperatively, it is essential to minimize the negative impact caused by primary angle-closure glaucoma. This involves personalized selection of different intraocular lenses or calculation formulas,etc. Evaluation metrics for visual quality encompass visual acuity, contrast sensitivity, higher-order aberrations, subjective perception, etc. Therefore, this paper provides a comprehensive review of postoperative refractive shift, higher-order aberrations, contrast sensitivity and their influencing factors, and the selection of intraocular lenses for patients undergoing combined surgery for primary angle-closure glaucoma with cataracts.

6.
International Eye Science ; (12): 491-494, 2024.
Article in Chinese | WPRIM | ID: wpr-1011407

ABSTRACT

AIM: To study the early outcomes of anterior segment parameters after implantation of an implantable collamer lens with a central hole(ICL V4c)in patients with high myopia.METHODS:A total of 82 cases(160 eyes)with high myopia, including 42 males(82 eyes)and 40 females(78 eyes), aged 26.0±4.6(21 to 37)years, who underwent ICL V4c implantation at our institution from February 2019 to September 2022 and were followed up for 1 a, were included. The general characteristics of the anterior segment of the eye were measured preoperatively: spherical equivalent, mean horizontal corneal curvature, white-to-white(WTW), and axial length(AL); intraocular pressure(IOP), endothelial cell density(ECD), central anterior chamber depth(CACD), anterior chamber volume(ACV)and anterior chamber angle(ACA)were measured preoperatively and at 1 d, 1 wk, 1, 3 and 6 mo postoperatively. Furthermore, the distance from the centre of the posterior surface of the ICL V4c optical zone to the anterior surface of the lens(vault)was measured at 1 d, 1 wk, 1, 6 mo, and 1 a after surgery.RESULTS: The mean preoperative spherical equivalent of the patients was -7.56±2.55 D, mean horizontal corneal curvature was 42.89±1.47 D, WTW was 11.64±0.37 mm, and AL was 26.64±0.93 mm. The baseline IOP was 15.97±2.13 mmHg, and the differences in IOP at each time point after ICL V4c implantation compared to preoperative were not statistically significant(F=0.875, P=0.504); ECD was 2 989.30±140.78 cells/mm2 at baseline, and ECD at 6 mo after ICL V4c implantation was not statistically significant compared with preoperative ECD(t=1.475, P=0.142); CACD was 3.19±0.21 mm at baseline, and ACV was 210.30±27.7 mm3, and CACD and ACV were significantly lower than preoperative at all postoperative time points(F=111.10, 288.38, all P<0.001). The baseline ACA was 35.44°±11.27°, and the ACA at each time point after ICL V4c implantation was significantly lower than preoperatively(F=21.23, P<0.001). The vault was 665.32±184.03 μm at 1 d postoperatively, and continued to be significantly reduced at 1 wk, 1, 6 mo, and 1 a postoperatively compared with 1 d(F=52.10, P<0.001). However, it remained stable at 6 mo and 1 a postoperatively, and the difference was not statistically significant compared with vault at 1 mo postoperatively(P>0.05).CONCLUSION: ICL V4c has certain safety and efficiency in 1 a postoperative follow-up, and the parameters of the anterior segment of the eye stabilized in the early period.

7.
International Eye Science ; (12): 469-472, 2024.
Article in Chinese | WPRIM | ID: wpr-1011403

ABSTRACT

AIM: To observe the clinical efficacy of 8-0 polypropylene scleral-sutured fixed intraocular lens(IOL)suspension implantation with the double knots technique in aphakic eyes.METHODS: Retrospective case series study. The data of 30 aphakic cases(31 eyes, 22 males)that underwent IOL suspension in our hospital from January 2021 to November 2022 were collected. The suspension of IOL(AcrySof IQ or Tecnis ZCB00)was performed by 8-0 polypropylene scleral-sutured with the double knots technique. The visual acuity, intraocular pressure(IOP), IOL position and complications with at least 6 mo of follow-up were observed.RESULTS: The mean preoperative uncorrected visual acuity(UCVA, LogMAR)and best-corrected visual acuity(BCVA, LogMAR)were 2.53±0.78 and 0.35±0.26, respectively, which were 0.58±0.26 and 0.36±0.27 at 6 mo postoperatively, respectively. And the differences in UCVA were statistically significant(t=15.408, P<0.01), whereas the difference in BCVA was not(t=-1.677, P=0.104). There were no intraoperative complications, with IOL position all centered, but 3 eyes had IOL tilt, 2 eyes had intraocular hypertension, 5 eyes had corneal edema, and 1 eye had suture exposure postoperatively. There were no complications such as hyphema, vitreous hemorrhage, macular edema, corneal endothelial decompensation, hypotony, choroidal detachment, retinal detachment, fulminant superior choroidal hemorrhage, endophthalmitis, or others.CONCLUSION: The 8-0 polypropylene scleral-sutured fixed intraocular lens suspension implantation with the double knots technique can improve the postoperative visual acuity of aphakic patients, and fewer complications, which is an option for the treatment of aphakia, dislocation of the lens and ligament abnormalities.

8.
International Eye Science ; (12): 463-468, 2024.
Article in Chinese | WPRIM | ID: wpr-1011402

ABSTRACT

AIM: To evaluate the convenience and accuracy of a novel smartphone-assisted “any-point two-step method” for finding the target axial position in cataract phacoemulsification combined with intraocular lens(IOL)implantation.METHODS: Prospective observational study. A total of 62 cases(62 eyes)of patients with age-related cataracts who underwent cataract phacoemulsification combined with IOL implantation in our hospital from October 2021 to April 2022 were selected. They were randomly divided into two groups: 31 cases(31 eyes)in the control group were applied with the “traditional two-step method” using slit lamp to mark the target axial position of the IOL, and 31 cases(31 eyes)in the experimental group were applied with the smartphone-assisted “two-step method” to mark the target axial position of the IOL. The Callisto eye navigation system was used as a standard reference, and the deviation of the reference marking point(deviation-1), the deviation of the target axial marking point(deviation-total), and the deviation of the angle from the reference marking point to the target axial marking point(deviation-2)were calculated and recorded as the preoperative axial marking time.RESULTS:Both deviation-1 and deviation-total values were lower in the experimental group than those in the control group(1.06°±1.39° vs 2.48°±2.23°, 1.77°±1.54° vs 2.81°±1.58°, all P<0.01), but there was no significant difference in the deviation-2 values between the two groups(1.35°±1.40° vs 1.48°±1.79°, P>0.05). The preoperative axial marking took shorter time in the experimental group than in the control group(1.77±1.70 min vs 2.88±3.20 min, P<0.01).CONCLUSION: The smartphone-assisted “any-point two-step method” for finding the target axial position in cataract phacoemulsification combined with IOL implantation is simple, time-saving, and accurate compared with the “traditional two-step method”.

9.
International Eye Science ; (12): 436-440, 2024.
Article in Chinese | WPRIM | ID: wpr-1011397

ABSTRACT

AIM: To explore the effects of femtosecond laser-assisted cataract surgery combined with intraocular lens implantation(FLACS-IOL)on postoperative deviation rate of multifocal intraocular lens(MIOL)and visual quality in cataract patients.METHODS: In the prospective study, 95 patients with cataract(108 eyes)who underwent MIOL implantation in the hospital between January 2021 and December 2022 were enrolled. According to different surgical methods, they were divided into FLACS group(51 cases, 56 eyes)and Phaco group(44 cases, 52 eyes). The operation time, incision diameter of anterior capsule, effective phaco time(EPT), cumulative dissipated energy(CDE), uncorrected distance visual acuity(UCDVA), best corrected distance visual acuity(BCDVA), eccentricity distance of IOL and deviation rate at 3 mo after surgery, total high order aberration(HOA), Trefoil and coma under 3 mm pupil were compared between the two groups.RESULTS: The operation time in the FLACS group was significantly shorter than that in the Phaco group, EPT and CDE were significantly lower than those in the Phaco group(all P<0.05). There was no significant difference in incision diameter of anterior capsule between the two groups(P>0.05). At 1 wk, 3 mo after surgery, UCDVA in the FLACS group was better than that in the Phaco group(all P<0.05). There were significant difference in UCDVA at 1 wk, 3 mo after surgery or BCDVA at 3 mo after surgery between the two groups(P<0.05). At 3 mo after surgery, eccentricity distance of IOL in the FLACS group was shorter than that in the Phaco group, and deviation rate was significantly lower than that in the Phaco group(all P<0.05). Under pupil diameter of 3 mm, HOA, trefoil and coma of whole eyes were decreased in both groups at 3 mo after surgery(P<0.05). At 3 mo after surgery, there were significant differences in HOA and trefoil of whole eyes between the FLACS group and Phaco group(P<0.05), but there was no significant difference in coma at 3 mo after surgery(P>0.05).CONCLUSION: FLACS-IOL can effectively reduce deviation rate of IOL and obtain better visual quality in cataract patients.

10.
International Eye Science ; (12): 432-435, 2024.
Article in Chinese | WPRIM | ID: wpr-1011396

ABSTRACT

AIM: To observe the efficacy of phacoemulsification combined with capsular tension ring and intraocular lens implantation in the treatment of high myopia with cataract.METHODS: Retrospective study. A total of 82 cases(82 eyes)of high myopia complicated with cataract who admitted to the cataract department of our hospital from December 2021 to April 2023 were selected as study objects, and they were divided into control group(n=39)and combination group(n=43)according to whether or not the capsular tension ring was used intraoperatively. Patients in the control group were treated with intraocular lens implantation alone, and those in the combination group were treated with phacoemulsification combined with capsular tension ring and intraocular lens implantation. The preoperative and postoperative best corrected visual acuity, central anterior chamber depth, trabecular ciliary process, visual quality and complications were compared.RESULTS: At 1 mo after surgery, the best corrected visual acuity(LogMAR)of both groups increased significantly(combination group: 0.64±0.28 vs 0.12±0.14; control group: 0.62±0.26 vs 0.23±0.25, both P<0.001). Central anterior chamber depth in both groups were higher than those before surgery(combination group: 2.57±0.56 vs 1.97±0.40 mm; control group: 2.22±0.45 vs 1.89±0.37 mm; both P<0.001), and the best corrected visual acuity and central anterior chamber depth of the combination group were significantly better than those of the control group(both P<0.05). The distance of trabecular ciliary process showed no statistical significance(combination group: 0.68±0.22 vs 0.74±0.20 mm; control group: 0.74±0.19 vs 0.78±0.17 mm, both P>0.05). The visual quality scores of the combination group were all higher than the control group at 1 mo after surgery [watching TV: 3.00±0.38 vs 2.22±0.46 points; reading books: 2.85±0.42 vs 2.21±0.44 points; night vision: 2.71±0.34 vs 2.37±0.41 points; fine operation: 2.82±0.38 vs 2.33±0.40 points, all P<0.001]. The incidence of complication in the combination group was significantly lower than that of the control group(33% vs 14%, P<0.05).CONCLUSION: Phacoemulsification combined with capsular tension ring and intraocular lens implantation can effectively promote the recovery of visual function, improve the structure of chamber angle, and reduce the incidence of complications in the treatment of patients with high myopia and cataract.

11.
International Eye Science ; (12): 403-410, 2024.
Article in Chinese | WPRIM | ID: wpr-1011391

ABSTRACT

Diseases of ocular fundus are the leading causes of severe vision impairment or even blindness in patients worldwide, and the medical treatments are seriously limited by the difficulty of therapeutic drugs entering the fundus due to the various physiological barriers. Nano-drug delivery systems, with their nanoscale size and large surface area, can be loaded with therapeutic drugs of different physicochemical properties and modified with various surface active substances, which can not only improve the solubility and penetration of the drugs, but also protect biologic drugs from degradation and improve the biological safety and bioavailability, as well as deliver therapeutic drugs to specific ocular targets. All of these make the therapeutic potential enormous. Currently, more and more studies have been carried out to take advantage of nanomaterials for the treatment of different fundus diseases, including neurodegenerative diseases, fundus neovascularization, endophthalmitis and fundus tumors. This review analyzes the challenges and barriers faced by different routes of drug administration in the treatment of fundus diseases, the physicochemical properties of common nano-drug delivery systems that have been studied in related fields, and further summarizes the progress, advantages, limitations, and future directions of the application of various nano-drug delivery systems for the treatment of ocular fundus diseases in recent years.

12.
International Eye Science ; (12): 356-361, 2024.
Article in Chinese | WPRIM | ID: wpr-1011382

ABSTRACT

AIM: To investigate the effect of residual astigmatism on visual quality after phacoemulsification combined with regional refractive intraocular lens(IOL)implantation in patients with age-related cataract, and to evaluate the astigmatism inclusivity of regional refractive IOL.METHODS: Retrospective cohort study. The clinical data of 62 cases(73 eyes)of age-related cataract patients who underwent phacoemulsification combined with regional refractive IOL(Lentis Comfort LS-313 MF15)implantation from July 2020 to March 2022 at the ophthalmology department of our hospital were collected. They were grouped according to residual astigmatism at 6 mo postoperatively, taking 35 cases(40 eyes)with residual astigmatism of 0.75 D to 1.50 D as the experimental group, and 27 cases(33 eyes)with residual astigmatism ≤0.75 D as the control group. Visual acuity, defocus curves, objective visual acuity [wavefront aberrations, Strehl ratio(SR), modulation transfer functions(MTF)], subjective visual acuity(national eye institute visual function questionnaire-25), patients' satisfaction, and spectacle independence were compared between the two groups at 6 mo postoperatively.RESULTS:There was a difference in the preoperative astigmatism and the number of postoperative 6 mo residual astigmatism between the two groups(P<0.01). At 6 mo postoperatively, there was no difference in uncorrected distance, intermediate, and near visual acuity, objective visual quality, subjective visual quality, satisfaction, and spectacle independence between the two groups(P>0.05). The defocus curves showed that there was no difference in visual acuity between the two groups at all points in the +2.00 to -4.00 D defocus range of the additional spherical equivalent(P>0.05).CONCLUSION:Lentis Comfort LS-313 MF15 IOL was able to accommodate regular astigmatism of 1.50 D.

13.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520230

ABSTRACT

ABSTRACT Purpose: To evaluate the influence of atmospheric pressure changes on the behavior of intraocular pressure of healthy military individuals-students and instructors of the National Navy's Diving & Rescue School at the "ARC BOLÍVAR" naval base-during a simulated immersion in the hyperbaric chamber of the Naval Hospital of Cartagena. Methods: A descriptive exploratory study was performed. The intraocular pressure was measured at different atmospheric pressures during 60-min sessions in the hyperbaric chamber while breathing compressed air. The maximum simulated depth was 60 feet. Participants were students and instructors of the Naval Base's Diving and Rescue Department. Results: A total of 48 eyes from 24 divers were studied, of which 22 (91.7%) were male. The mean age of the participants was 30.6 (SD=5.5) years, ranging from 23 to 40. No participant had a history of glaucoma or ocular hypertension. The mean base intraocular pressure at sea level was 14 mmHg, which decreased to 13.1 mmHg (decreased by 1.2 mmHg) at 60 feet deep (p=0.0012). However, during the safety stop at 30 feet, the mean IOP kept decreasing until reaching 11.9 mmHg (p<0.001). By the end of the session, the mean intraocular pressure reached 13.1 mmHg, which is inferior and statistically significant when compared with the intraocular pressure base mean (p=0.012). Conclusions: In healthy individuals, the intraocular pressure decreases when reaching a depth of 60 feet (2.8 absolute atmosphere pressure) and it decreases even more during ascension at 30 feet. Measurements at both points were significantly different when compared with base intraocular pressure. The final intraocular pressure was lower than the baseline intraocular pressure, suggesting a residual and prolonged effect of the atmospheric pressure on intraocular pressure.


RESUMO Objetivo: Avaliar a influência das alterações da pressão atmosférica no comportamento da pressão intraocular de indivíduos militares saudáveis-alunos e instrutores da Escola de Mergulho e Resgate da Marinha Nacional na base naval "ARC BOLÍVAR"-durante uma imersão simulada na câmara hiperbárica do Hospital da Marinha de Cartagena. Métodos: Realizamos um estudo exploratório descritivo. A pressão intraocular foi medida em diferentes pressões atmosféricas durante sessões de 60 minutos na câmara hiperbárica respirando ar comprimido. A profundidade máxima simulada foi de 60 pés. Os participantes eram alunos e instrutores do Departamento de Mergulho e Resgate da Base Naval. Resultados: Quarenta e oito olhos de 24 mergulhadores foram estudados. Vinte e dois participantes (91,7%) eram do sexo masculino. A média de idade dos participantes foi de 30,6 (DP=5,5) anos, variando de 23 a 40. Nenhum participante tinha histórico de glaucoma ou hipertensão ocular. A média de base da pressão intraocular ao nível do mar foi de 14 mmHg, diminuindo para 13,1 mmHg (queda de 1,2 mmHg) a 60 pés de profundidade (p=0,0012). Entretanto, durante a parada de segurança a 30 pés, a pressão intraocular média continuou diminuindo até atingir 11,9 mmHg (p<0,001). Ao final da sessão, a pressão intraocular média atingiu 13,1 mmHg, valor inferior e estatisticamente significativo quando comparada à média de base da pressão intraocular (p=0,012). Conclusões: Em indivíduos saudáveis, a pressão intraocular diminui ao atingir uma profundidade de 60 pés (2,8 de pressão atmosférica absoluta) e diminui ainda mais durante a ascensão a 30 pés. As medidas em ambos os pontos foram significativamente diferentes quando comparadas à pressão intraocular de base. A pressão intraocular final foi menor do que a pressão intraocular de base, sugerindo um efeito residual e prolongado da pressão atmosférica sobre a pressão intraocular.

14.
Arq. bras. oftalmol ; 87(6): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520246

ABSTRACT

ABSTRACT Purpose: To evaluate using optical coherence tomography angiography the macular and optic nerve head blood flow in pediatric patients with epilepsy treated with levetiracetam for at least 12 months. Methods: This study included 33 pediatric patients with epilepsy and 30 sex- and age-matched healthy volunteer children were included in the study. Optical coherence tomography angiography was used to evaluate the optic nerve head and macular perfusion changes. The mean ocular perfusion pressures were also calculated. Patients who were using multiple antiepileptic drugs or had a prior history of using different drugs were excluded. Results: The choriocapillaris flow area was significantly lower in the Study Group than in the Control Group (p=0.006). However, the foveal avascular zone and vessel densities of the macula in the superficial capillary plexus, deep capillary plexus, and optic nerve head of the study group were not significantly different from those of the control group (p>0.05). Moreover, no significant difference in means of mean ocular perfusion pressure was found between the two groups (p=0.211). No obvious correlation was found between treatment duration and optical coherence tomography angiography parameters or mean ocular perfusion pressure. Conclusion: Choroidal perfusion was reduced in children taking levetiracetam compared with that in the control group, whereas retinal perfusion was not affected in this optical coherence tomography angiography study.


RESUMO Objetivo: Avaliar através de angiotomografia de coerência óptica o fluxo sanguíneo macular e da cabeça do nervo óptico em pacientes pediátricos com epilepsia tratados com levetiracetam por pelo menos 12 meses. Método: Trinta e três pacientes pediátricos com epilepsia e 30 crianças voluntárias saudáveis pareadas por sexo e idade foram incluídos no estudo. A angiotomografia de coerência óptica foi utilizada para avaliar as alterações da perfusão da cabeça do nervo óptico e da macular. As médias das pressões de perfusão ocular também foram calculadas. Pacientes em uso de múltiplas drogas antiepilépticas ou com história prévia de uso de diferentes drogas foram excluídos do estudo. Resultado: A área do fluxo coriocapilar foi significativamente menor no Grupo Estudo do que no Grupo Controle (p=0,006). Entretanto, a zona avascular foveal e as densidades vasculares no plexo capilar superficial e profundo da região macular e na cabeça do nervo óptico não foram significativamente diferentes daquelas de olhos saudáveis (p>0,05). Também não houve diferença significativa entre os dois grupos em relação às médias da pressão de perfusão ocular (p=0,211). Nenhuma correlação aparente foi encontrada entre a duração do tratamento e os parâmetros da angiotomografia de coerência óptica ou a média da pressão de perfusão ocular. Conclusão: Em crianças usando levetiracetam, a perfusão coroidal mostrou-se reduzida em comparação ao grupo controle, enquanto a perfusão retiniana não foi afetada neste estudo com angiotomografia de coerência óptica.

15.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527807

ABSTRACT

ABSTRACT Purpose: Only a few trials have compared the intraocular pressure-lowering effects of prostaglandin analogs to carbonic anhydrase inhibitor plus beta-blocker fixed-dose combination therapy in patients with pseudoexfoliative glaucoma. Furthermore, the influence of the glaucoma stage on the intraocular pressure-lowering effects of these drug types has not been studied. The purpose of this study was to compare the IOP-lowering efficacy of latanoprost, a prostaglandin analog versus dorzolamide/timolol fixed combination, a carbonic anhydrase inhibitor plus beta-blocker fixed-dose combination therapy, in patients with pseudoexfoliative glaucoma based on glaucoma stage. Methods: The data of 32 eyes (32 patients) diagnosed with uniocular pseudoexfoliative glaucoma and treated with topical latanoprost (Group 1) or dorzolamide/timolol fixed combination (Group 2) were retrospectively assessed. The groups were subdivided into early and moderate-advanced stages. Patients' demographics, baseline intraocular pressure, final intraocular pressure, and intraocular pressure difference (the difference between the baseline and final intraocular pressure) were determined from medical records and compared between groups and according to glaucoma stage. Results: The mean drug use duration was 17.7 ± 13.5 months. No significant differences in mean baseline intraocular pressure, mean final intraocular pressure and mean intraocular pressure difference between Groups 1 and 2. In Group 2, the mean intraocular pressure difference was significantly greater in patients with early versus moderate-advanced stage glaucoma (p=0.015). The difference, however, was not detected in Group 1. The mean intraocular pressure difference in early-stage glaucoma was significantly greater in Group 2 versus 1 (p=0.033). Conclusions: Latanoprost and dorzolamide/timolol fixed combination are effective treatments for newly diagnosed pseudoexfoliative glaucoma. In early-stage pseudoexfoliative glaucoma, greater intraocular pressure reduction was noted with dorzolamide/timolol fixed combination than with latanoprost; thus, dorzolamide/timolol fixed combination should be considered when a significant decrease in intraocular pressure is desired in early-stage glaucoma.


RESUMO Objetivo: Estudos limitados examinaram os efeitos de redução de pressão intraocular de análogos de prostaglandina versus inibidor de anidrase carbônica mais terapia de combinação de dose fixa beta-bloqueador em pacientes com glaucoma pseudoesfoliativo. Além disso, a influência do estágio de glaucoma nos efeitos de redução da pressão intraocular desses tipos de drogas não foi avaliada. Este estudo teve como objetivo comparar a eficácia de redução do IOP do latanoprosta, uma combinação fixa análoga de prostaglandina versus dorzolamida/timolol, um inibidor de anidrase carbônica mais terapia de combinação de dose fixa beta-bloqueador, em pacientes com glaucoma pseudoesfoliativo de acordo com o estágio de glaucoma. Métodos: Os dados de 32 olhos (32 pacientes) diagnosticados com glaucoma pseudoesfoliativo monocular e tratados com latanoprosta tópica (Grupo 1) ou combinação fixa de dorzolamida/timolol (Grupo 2) foram avaliados retrospectivamente. Os grupos foram subdivididos em estágios inicial e moderado-avançado. A demografia dos pacientes, a pressão intraocular da linha de base, a pressão intraocular final e a diferença de pressão intraocular (a diferença entre a pressão intraocular da linha de base e a pressão intraocular final) foram determinadas a partir dos prontuários médicos e comparadas entre os dois grupos e de acordo com o estágio de glaucoma. Resultados: A duração média do uso de drogas foi de 17,7 ± 13,5 meses. Nenhuma diferença significativa foi observada entre os grupos 1 e 2 para a média da pressão intraocularda linha de base, média da pressão intraocular final e média da diferença da pressão intraocular. No Grupo 2, a média da diferença da pressão intraocular foi significativamente maior em pacientes com glaucoma de estágio precoce versus moderado-avançado (p=0,015). No entanto, essa diferença não foi observada no Grupo 1. A média da diferença da pressão intraocular em glaucoma de estágio inicial foi significativamente maior no Grupo 2 versus 1 (p=0,033). Conclusões: Terapias com Latanoprosta e dorzolamida/timolol são tratamentos eficazes para glaucoma pseudoesfoliativo recém-diagnosticado. Observou-se em glaucoma pseudoesfoliativo de estágio inicial, uma maior redução da pressão intraocular com combinação fixa de dorzolamida/timolol do que com latanoprosta; assim, a combinação fixa de dorzolamida/timolol deve ser considerada quando uma diminuição significativa da pressão intraocular é almejada em glaucoma de estágio inicial.

16.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527816

ABSTRACT

ABSTRACT Purpose: To evaluate the effect of tobacco smoking on trabeculectomy outcomes. Methods: Charts of patients with glaucoma who underwent trabeculectomy performed by a single surgeon between 2007 and 2016 were retrospectively reviewed. Charts were screened for a documented history of smoking status before surgery. Demographic and clinical preoperative variables were recorded. Based on smoking history, subjects were divided into two groups: smokers and nonsmokers. Any bleb-related interventions (e.g., 5-flourouracil injections ± laser suture lysis) or bleb revision performed during the postoperative period were noted. Success was defined as an intraocular pressure >5 mmHg and <21 mm Hg without (complete success) or with (qualified success) the use of ocular hypotensive medications. Failure was identified as a violation of the criteria mentioned above. Results: A total of 98 eyes from 83 subjects were included. The mean age of the subjects was 70.7 ± 11.09 years, and 53% (44/83) were female. The most common diagnosis was primary open-angle glaucoma in 47 cases (47.9%). The smokers Group included 30 eyes from 30 subjects. When compared with nonsmokers, smokers had a significantly worse preoperative best-corrected visual acuity (p=0.038), greater central corneal thickness (p=0.047), and higher preoperative intraocular pressure (p=0.011). The success rate of trabeculectomy surgery at 1 year was 56.7% in the smokers Group compared with 79.4% in the Group nonsmokers (p=0.020). Smoking presented an odds ratio for failure of 2.95 (95% confidence interval, 1.6-7.84). Conclusion: Smokers demonstrated a significantly lower success rate 1 year after trabeculectomy compared with nonsmokers and a higher requirement for bleb-related interventions.


RESUMO Objetivo: Avaliar o efeito do tabagismo nos desfechos da trabeculectomia. Métodos: Uma revisão retrospectiva do gráfico de pacientes com glaucoma submetidos à trabeculectomia foi realizada por um único cirurgião entre 2007 e 2016. Os gráficos foram examinados para uma história documentada de condição de fumante antes da cirurgia. Variáveis pré-operatórias clínicas e demográficas e clínicas foram registradas. Os pacientes foram divididos em dois grupos de acordo com sua história de tabagismo em fumantes e não fumantes. Quaisquer Intervenções relacionadas à bolha, por exemplo, injeções de 5-fluorouracil + lise de sutura com laser, ou revisão da bolha realizada durante o período pós-operatório foram observadas. O sucesso foi definido como pressão intraocular > 5 mmHg e < 21 mm Hg sem (sucesso completo) ou com (sucesso qualificado) medicamentos hipotensores oculares. A falha foi identificada como violação dos critérios mencionados acima. Resultados: O estudo incluiu 98 olhos de 83 pacientes com idade média de 70,7 ± 11,09 anos, sendo 53% (44/83) dos pacientes do sexo feminino. O diagnóstico mais comum foi o glaucoma de ângulo aberto primário com 47 casos (47,9%). O Grupo de fumantes incluiu 30 olhos de 30 pacientes. Os fumantes, quando comparados aos não fumantes, apresentaram uma melhor acuidade visual pré-operatória significativamente pior (p=0,038), maior espessura central da córnea (p=0,047) e maior pressão intraocular pré-operatória (p=0,011). A taxa de sucesso de um ano para a cirurgia de trabeculectomia foi de 56,7% no Grupo de fumantes contra 79,4% no Grupo de não fumantes (p=0,020). O tabagismo apresentou razão de chances para falha de 2,95 95% de IC (1,6-7,84). Conclusão: Os fumantes demonstraram uma taxa de sucesso significativamente menor em um ano após a trabeculectomia em comparação com os não fumantes e uma maior necessidade de intervenções relacionadas à bolha.

17.
Arq. bras. oftalmol ; 87(2): e2021, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527833

ABSTRACT

ABSTRACT A 59-year-old man presented with a unilateral blurring of vision in his left eye. His left eye's visual acuity was hand movements level. He underwent phacoemulsification surgery, and an intrastromal posterior chamber intraocular lens was implanted. The intrastromal intraocular lens was extracted and a new intraocular lens was implanted. Usinge the Snellen chart, the final best-corrected visual acuity was 20/40. With this case report, we wish to emphasize that a single stepwise clear corneal incision merged with wound-assisted intraocular lens injections can result in intraocular lens misdirection into the corneal stroma. As a result, while performing a misdirected intraocular lens removal, we recommend that the wound be carefully constructed.


RESUMO Um homem de 59 anos apresentou embaçamento visual unilateral no olho esquerdo. Sua acuidade visual nesse olho era no nível de movimentos da mão. O paciente havia se submetido a uma cirurgia de facoemulsificação em que foi feita a implantação intraestromal de uma lente intraocular de câmara posterior. Foi feita a extração dessa lente intraestromal intraocular e uma nova lente intraocular foi implantada. A melhor acuidade visual corrigida final foi de 20/40 pela tabela de Snellen. Com este relato de caso, os autores desejam apontar que uma incisão de degrau único em córnea clara, quando combinada com a injeção de uma lente ocular através da incisão, pode levar a um direcionamento incorreto da lente intraocular para dentro do estroma corneano. Portanto, recomenda-se uma construção cuidadosa da incisão ao se remover uma lente intraocular direcionada incorretamente.

18.
Arq. bras. oftalmol ; 87(2): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533786

ABSTRACT

ABSTRACT Purpose: As superotemporal implantation of the Ahmed glaucoma valve is not always feasible in cases of refractory glaucoma, this study examined the characteristics and surgical outcomes of cases in which the valve was implanted in a nonsuperotemporal quadrant using a modified long scleral tunnel technique. Methods: This retrospective case-control study included 37 eyes with nonsuperotemporal quadrant--Ahmed glaucoma valve implantation in Group 1 and 69 eyes with superotemporal Ahmed glaucoma valve implantation in Group 2. The demographic characteristics of these groups, surgical outcomes, including complications, further surgical interventions, and surgical success rates were compared. Surgical success was defined as an intraocular pressure not exceeding 21 mmHg, accompanied by a minimum reduction of 20% in intraocular pressure from the baseline without any additional intraocular pressure-lowering procedures, and the absence of light perception loss or phthisis bulbi. Results: Group 1 had significantly higher numbers of eyes with secondary glaucoma and preoperative surgical procedures than Group 2 (p<0.05). Both groups had mean preoperative intraocular pressure values, and mean intraocular pressure values at the last visit of 34.2 and 27.9 months, 35.5 ± 1.5 and 35.8 ± 1.2 mmHg, and 14.5 ± 5 and 14.9 mmHg, respectively. Although both groups had 70.2% and 75.8% as their five-year cumulative probability of success, respectively, the rates of complications, revisional surgery, and additional surgical procedures did not differ significantly (p>0.05). Conclusion: The modified long scleral tunnel technique for Ahmed glaucoma valve implantation in nonsuperotemporal quadrants achieves intraocular pressure control and complication rates comparable to superotemporal implantation.

19.
Acta Medica Philippina ; : 1-6, 2024.
Article in English | WPRIM | ID: wpr-1006604

ABSTRACT

Objective@#Toric intraocular lens implantation has been used to correct corneal astigmatism during cataract surgery. The study aimed to compare the visual outcomes between manual vs markerless toric intraocular lens implantation in astigmatic correction.@*Methods@#The medical records of patients at American Eye Center who underwent phacoemulsification by multiple surgeons with insertion of monofocal or multifocal toric lenses via manual marking and markerless method from 2010-2019 were reviewed.@*Results@#A total of 70 patients were included in the study. Results showed no significant difference in the following characteristics between manual and markerless method at one month and two months post-cataract surgery: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near vision acuity (UNVA), corrected near vision acuity (CNVA), refraction spherical equivalent. The UDVA, CDVA, UNVA, CNVA and astigmatism had significantly lower median/mean-rank at one and two months postoperatively compared to preoperative values.@*Conclusion@#In conclusion, our findings indicated that both manual-based and markerless systems effectively facilitated accurate placement of the toric IOL on the desired axis. Notably, there was no significant difference observed between the two methods. Both systems are straightforward to execute. In low-resource settings like the Philippines, the manual marking method can be employed when markerless guidance equipment is unavailable.


Subject(s)
Phacoemulsification , Astigmatism , Philippines
20.
Indian J Ophthalmol ; 2023 Sep; 71(9): 3224-3228
Article | IMSEAR | ID: sea-225246

ABSTRACT

Purpose: To evaluate the accuracy of intraocular lens (IOL) power prediction of the formulas available on the American Society of Cataract and Refractive Surgery (ASCRS) post?refractive calculator in eyes with prior radial keratotomy (RK) for myopia. Methods: This retrospective study included 25 eyes of 18 patients whose status was post?RK for treatment of myopia, which had undergone cataract extraction with IOL implantation. Prediction error was calculated as the difference between implanted IOL power and predicted power by various formulae available on ASCRS post?refractive calculator. The formulas compared were Humphrey Atlas method, IOLMaster/Lenstar method, Barrett True?K no?history formula, ASCRS Average power, and ASCRS Maximum power on ASCRS post?refractive calculator. Results: Median absolute errors were the least for Barrett True?K and ASCRS Maximum power, that is, 0.56 (0.25, 1.04) and 0.56 (0.25, 1.06) D, respectively, and that of Atlas method was 1.60 (0.85, 2.28) D. Median arithmetic errors were positive for Atlas, Barrett True?K, ASCRS Average (0.86 [?0.17, 1.61], 0.14 [?0.22 to 0.54], and 0.23 [?0.054, 0.76] D, respectively) and negative for IOLMaster/Lenstar method and ASCRS Maximum power (?0.02 [?0.46 to 0.38] and ? 0.48 [?1.06 to ? 0.22] D, respectively). Multiple comparison analysis of Friedman抯 test revealed that Atlas formula was significantly different from IOLMaster/ Lenstar, Barrett True?K, and ASCRS Maximum power; ASCRS Maximum power was significantly different from all others (P < 0.00001). Conclusion: In post?RK eyes, Barrett True?K no?history formula and ASCRS Maximum power given by the ASCRS calculator were more accurate than other available formulas, with ASCRS Maximum leading to more myopic outcomes when compared to others