1.
Chinese Journal of Laboratory Medicine ; (12): 456-462, 2022.
Article in Chinese | WPRIM | ID: wpr-934396

ABSTRACT

Objective:To establish a candidate reference method for serum progesterone using isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) in our laboratory, validate the analytic performance of five clinical routine detection systems to explore the comparability of serum progesterone detection by different detection systems.Methods:A candidate reference method for serum progesterone using ID-LC/MS/MS method was established. The sample was pretreated by liquid-liquid extraction method, and the reversed phase liquid phase separation in positive ion mass spectrometry mode was used to detect progesterone in human serum, and the detection time of a single sample was controlled within 5 minutes by gradient elution. In order to improve the accuracy of the method, the bracketing calibration method (BCM) was used to establish the standard curve. The sensitivity, accuracy, precision and specificity of BCM and classical calibration curve method were evaluated according to CLSI C62-A, EP15-A2, EP6-A2 and EP9-A3, and the analytical performance and comparability of five clinical routine progesterone detection systems were evaluated,compared with ID-LC/MS/MS method, the bias at medical decision level 2 and 25 ng/ml was evaluated to see if they were <1/2TEa (12.5%).Results:The limit of detection (LOD) of ID-LC/MS/MS was 0.005 ng/ml. The recoveries of BCM method and classical calibration curve method are 97.95%-101.58% and 96.88%-110.70%, respectively. The measurement results of BCM method for certified reference materials are within its declared uncertainty range. The intra-and inter-assay coefficient of variation ( CV) of BCM method was less than 3.0%, which was better than that of classical calibration curve method ( CV: 2.48%-9.33%). The precision and linear range of the five clinical routine detection systems can meet the detection requirements. The measurement bias of detection system 1, 3 and 5 at 25 ng/ml of medical decision level was less than 1/2TEa, and the measurement bias at 2 ng/ml of medical decision level was more than 1/2TEa. The measurement bias of detection system 2 and 4 at two medical decision levels was less than 1/2TEa. Conclusion:The candidate reference method for serum progesterone ID-LC/MS/MS established in our laboratory meets the requirements of the reference method. BCM has better detection performance than classical calibration curve method. The precision and linearity of the five progesterone clinical detection systems are satisfactory. The five clinical detection systems could meet the clinical requirements at the medical determination level of 25 ng/ml, however, only two of the five clinical detection systems meet the clinical requirements at the medical determination level of 2 ng/ml.

2.
Chinese Journal of Laboratory Medicine ; (12): 736-742, 2021.
Article in Chinese | WPRIM | ID: wpr-912467

ABSTRACT

Objectives:To establish a candidate reference method of isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) for the determination of human plasma normetanephrine, and to evaluate the performance of the method. The method was used to quantify the samples of the external quality assessment program, and to initially evaluate the detection status of plasma normetanephrine.Methods:The isotope standard solution of normetanephrine was selected as the internal standard, the gravimetric method was used for sampling, and the standard curve method was used for quantification. Protein precipitation combined with weak cation solid phase extraction was used for pretreatment, and ultra-high liquid chromatography-coupled triple quadrupole mass spectrometry was used for LC/MS analysis. According to the relevant EP documents, the specificity, matrix effect, detection limit, quantification limit, precision, accuracy, and uncertainty of the method were estimated. This method is used to quantify the samples of the 2020 National Center for Clinical Laboratories external quality assessment program of normetanephrine. Taking the average value of this method as the target value, the optimal allowable total error standard of biological variation as the evaluation limit, the quality of the laboratory testing was evaluated.Results:The method had good specificity, and the interferences and matrix effects did not affect the detection results. The detection limit and quantification limit of plasma normetanephrine were 1.08 pg/g and 3.54 pg/g, respectively. The intra-batch coefficient of variation ( CV) and total CV were 0.43%-1.10% and 0.61%-1.42%, respectively. The relative recovery rates were 98.5%~101.9%. The relative expansion uncertainty of the four plasma samples were 3.10%, 2.34%, 2.16%, and 1.73%, respectively. The results of the external quality assessment program showed that the pass rates of the 202013 and 202014 samples were 80% and 85%, respectively. Conclusions:The study established a candidate reference method of ID-LC/MS/MS for the measurement of plasma normetanephrine. The method is accurate, precise and simple, and is expected to be used as a reference method for the determination of plasma normetanephrine, and can be applied to quantify the samples of the external quality assessment program.

3.
Chinese Journal of Clinical Laboratory Science ; (12): 161-165, 2018.
Article in Chinese | WPRIM | ID: wpr-694819

ABSTRACT

Objective To develop an isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) method for determining the concentration of 5-methyltertrahydrofolate (5MT) in human serum.Methods After qualitative analysis of 5MT reference,its purity was identified by two methods with different principle,i.e.,mass balance and quantitative nuclear magnetic resonance.The definite value and uncertainty of 5MT concentrations in 6 serum samples containing same level of 5MT were assessed by ultra performance liquid chromatography-triple quadrupole tandem mass spectrometer equipped with electrospray ionization in monitoring mode of multiple reactions,in which 13C5-5MT was used as the internal standard.The precision,accuracy,limit of detection (LOD) and limit of quantification (LOQ) of the method were also evaluated.Results After qualitative analysis for confirming the principal component in the sample,the purity of 5MT reference was measured as 76.65% by mass balance and quantitative nuclear magnetic resonance method.The definite value of 5MT in the serum sample was 8.22 ng/mL,the extended uncertainty was 0.54 ng/mL,LOD was 0.05 ng/mL,LOQ was 0.50 ng/mL and the repeatability and inter-batch precision CV were within 5.0%.The accuracy of measured results was verified by using NIST SRM 1955 since all the values of 3 levels were within the range of certified value with the extended uncertainty.Conclusion A accurately quantitative determination for the concentration of 5 MT in human serum with high specificity and sensitivity was established by using ID-LC-MS/MS method.

4.
Chinese Journal of Clinical Laboratory Science ; (12): 690-695, 2017.
Article in Chinese | WPRIM | ID: wpr-666695

ABSTRACT

Objective To summarize and review the comparative results of the isotope dilution mass spectrometry in Cholesterol Reference Method Laboratory Network (CRMLN)project of the Centers for Disease Control and Prevention (CDC)of the United States in order to provide quality controls for determination of blood lipid.Methods The isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS)methods for determination of serum total cholesterol (TC)and triglycerides (TG)were developed to participate in the comparison of CRMLN.The survey was conducted every three months before 2016 and every half year from 2016.Four kinds of reference materials with two parallel tubes for each material and each tube in duplicate were determined in every survey.At least two certified reference materials used as quality control samples were analyzed simultaneously in each determination.Results In the 15 comparisons the CV of the TC determination method in our laboratory was 0.43% while the CV of all the participated laboratories in CRMLN was 0.42%.The bias from the overall mean value in our laboratory was 0.22% while the bias from the CDC target values was 0.58%.The CV of the TG determination method in 15 tests of our laboratory was 0.62% and the bias was-0.98% from the overall mean value and-0.80% from the target values of CDC.Among the 60 results for comparison,98% (59/60)of CV in the TC determination met with CDC requirement for precision (CV≤ 1%),and 70% of bias (42/60) of the results met with CDC requirement for accuracy (bias ≤ 1%).For the 60 results in comparison of TG determination,92% (55/60)of bias of the results met with the accuracy requirement of CDC (bias ≤2.55%).Conclusion In CRMLN comparison the results of TC and TG determined by ID-LC/MS/MS method were consistent with the values which were certified by CDC and determined by other network laboratories.The comparative surveys may play an important role in the standardization of lipid determination,and should be expected to provide experiences and technical supports in the comparative plan for reference measurement in our country.