Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
International Eye Science ; (12): 1161-1164, 2015.
Article in Chinese | WPRIM | ID: wpr-634260

ABSTRACT

AlM:To observe the clinical effect of 2. 2mm micro-incision phacoemulsification ( Phaco ) combined intraocular lens( lOL) implantation in the eyes with short axial length and compared with traditional 3. 0mm incision phacoemulsification operation for clinical work and research objective information.METHODS:ln this prospective clinical control study, 60 cases (60 eyes) with cataract performed 2. 2mm micro-incision phacoemulsification combined lOL implantation ( micro-incision group, implanted Akreos Ml60 lOL ) and 3. 0mm incision phacoemulsification operation ( small incision group, implanted Akreos Adapt lOL ) , whose axial length ranged 17. 68 ~ 21. 32mm, average 20. 35 ± 0. 61mm. Average axiall ength respectively of two groups:20.57±0.39mm and 20.21±0.52mm. Effect Phaco time ( EPT ) and average ultrasonic energy ( AVE ) were recorded. The best corrected visual acuity ( BCVA ) , intraocular pressure ( lOP ) , anterior chamber depth ( ACD) , corneal endothelial cell density and the operative complications were observed postoperatively. All cases were followed up at 1, 7, 30 and 90d after operation.RESULTS:EPT and AVE between two groups had no statistical significance(P>0. 05). At the 1, 7 and 30d after surgery, induced astigmatism ( SlA ) of micro-incision group was lower than that of small-incision group. SlA between two groups had statistically significant ( P 0. 05). At the 7d, the BCVA between two groups had statistical significance(P0. 05). At the 7, 30 and 90d, corneal endothelial cell density of micro-incision group was higher than that of small incision group. Corneal endothelial cell density between two groups had no statistical significance. The mean ACD was significant increased postoperatively than preoperatively and had no statistical significance ( P>0. 05 ) . The anterior chamber stabilized during the operation. There was not incision hot harmed during operation and postoperation.CONCLUSlON:Compared with 2. 2mm micro-incision and traditional 3. 0mm incision phacoemulsification, two groups have the same safety and 2. 2mm micro-incision phacoemulsification has small SlA, organization small harm and improved visual acuity in early stage.

2.
International Eye Science ; (12): 1266-1268, 2014.
Article in Chinese | WPRIM | ID: wpr-641974

ABSTRACT

AlM: To observe the clinical effect of micro-incision phacoemulsification combined with silicone oil removal from pars plana in eyes with silicone oil tamponade after vitrectomy. METHODS:Forty-three patients (43 eyes) with cataract and silicone oiltamponade after vitrectomy underwent micro-coaxial phacoemulsification combined with silicone oil removal from pars plana between February 2013 and November 2013. lntraocular lens was implanted at stage l in all cases. The best corrected visual acuity was observed at 3mo after operation, and the complications were recorded. RESULTS: The best corrected visual acuity in 39 cases (91%) was improved at 3mo after operation, and the best outcome was 0. 6. There were still 4 cases (9%) without improvement of visual acuity. There was no incidence of complications such as posterior capsular rupture, residual silicone oil, corneal endothelial decompensation, hyphema, vitreous hemorrhage, intraocular lens dislocation, secondary glaucoma and ora serrata mutilation after operation in all patients. CONCLUSlON: Micro - invision phacoemulsification combined with silicone oil removal from pars plana is an effective and safe method for eyes with cataract and silicone oil tamponade after vitrectomy.

SELECTION OF CITATIONS
SEARCH DETAIL