1.
Chinese Medical Equipment Journal ; (6): 97-100, 2017.
Article in Chinese | WPRIM | ID: wpr-511344

ABSTRACT

Objective To compare the clinical values of impedance method,optical method and microscopy when used to detect platelet abnormal results.Methods Platelet re-examinations by optical method and microscopy were carried out in case of low confidence degree in platelet test with impedance method by XE-2100 automatic hematology analyzer,and then the results by the three methods were compared.Results Most of the low-confidence-degree results by impedance method could be corrected by re-examination by optical method,and the remained had to turn to microscopy due to unsatisfied requirements of the instrument.Conclusion Optical method has to be involved to correct the platelet abnormal results by XE2100 automatic hematology analyzer,and microscopy should be applied in case optical method doesn't work.The three methods gains advantages and disadvantages of themselves,and can be supplementaries for one another.

2.
International Journal of Laboratory Medicine ; (12): 3105-3106,3109, 2014.
Article in Chinese | WPRIM | ID: wpr-599967

ABSTRACT

Objective To compare the differences of platelet(PLT) count between the optical method (PLT‐O) and electrical impedance method (PLT‐I) ,using microscopic method (PLT‐M) as a standard method ,and to analyze the alarm information of in‐strument .Methods Both of PLT‐O and PLT‐M of 468 cases of patient specimens were detected by Sysmex XE‐2100 automatic hematocyte analyzer ,and which were compared with PLT‐M .The counts and morphology of red blood cells and platelets were de‐tected by microscopic method .The alarm information of red blood cells and platelets were recorded .Results In non‐hematopathy group ,there was no significant difference among PLT‐M ,PLT‐I and PLT‐O (P=0 .071) .In hematopathy group ,PLT‐I was signifi‐cantly different from both PLT‐M and PLT‐O (P0 .05) .There were 149 cases occurring platelets alarm and 127 cases occurring red blood cells alarm in hematopathy group , which was consistent with the results of microscopic method .Conclusion When the value of PLT is below the normal reference range ,counting error of PLT‐I is large and the value of PLT should be rechecked or corrected using PLT‐M and PLT‐O .Re‐exam‐ination should be performed when alarm information is displayed .

3.
International Journal of Laboratory Medicine ; (12): 1766-1767,1769, 2014.
Article in Chinese | WPRIM | ID: wpr-553600

ABSTRACT

Objective To know how large platelets influnece the platelet count difference of the optical and impedance methods so as to provide the support for the reasonable application of optical method and effectively increasing the accuracy of platelet count.Methods 132 blood routine specimens with normal RBC parameters were anaylzed by both electrical impedance and optical methods with the Sysmex-XE5000 fully automativ hematology analyzer.The data were divided into the large platelet group and the normal platelet group according to the platlet-large cell ratio(P-LCR)results.The RBC and platelet parameters were compared be-tween the two groups with the unpaired t-test and the platelet count results detected by the optical and electrical impedance methods were compared within group with the paired t-test.Results The extremely significant differences of platelet parameters existed be-tween the two groups.The P-LCR,MPV,PDW and IPF % of the large platelet group were significantly higher than those of the normal platelet group,but the RBC parameters had no obvious difference.The significant difference of the platelet count also existed between the electrical impedance and optical methods in the large platelet group(P <0.05 ),the platelet count results detected by the electrical impedance method was on the low side,but the normal platelet group had no significant difference.Conclusion P-LCR increase is related with the increase of immature platelet.The electrical impadence method conducts the differentiation according to the granular size,which is easy to exclude the large platelel with larger volume and leads to reduce the platelet count results.There-fore,when P-LCR is increased,the optical method should be adopted in conducting the platelet count for avoiding the false reduce caused by the electrical impedance method.

4.
International Journal of Laboratory Medicine ; (12): 2816-2817, 2014.
Article in Chinese | WPRIM | ID: wpr-459926

ABSTRACT

Objective To investigate the inaccurate causes of platelet(PLT)count and to propose the correcting measures.Meth-ods 180 specimens of abnormal PLT count were collected and divided into 4 groups:low PLT count group (PLT ≤20×109/L,72 cases),microcyte group(54 cases),large platelets group(33 cases)and platelet aggregation group(21 cases).The PLT count was simultaneously performed by using the three ways of the optical method (PLT-O),impedance method (PLT-I)and manual micros-copy method (PLT-M).The detection results were analyzed by the paired t test.Results The PLT count in the low PLT group, microcyte group and large platelets group had no statistical differences between PLT-O and PLT-M(P >0.05),and had statistical differences between the PLT-I and PLT-O(P <0.05).The PLT count of PLT-O in the platelet aggregation group was more close to actual value than that of PLT-I(P <0.05).Conclusion The PLT count by PLT-I has many influencing factors,which are mainly the microcytes interference leading to higher PLT count,missed detection of large PLT leading to lower PLT count,PLT aggrega-tion,etc.When the PLT count appears abnormal,the re-detection should be conducted according to the re-detection regulation, which can be corrected by adopting PLT-M or PLT-O,in necessity,the blood specimen could be re-collected for detection.